{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T22:03:12Z","timestamp":1791928992429,"version":"4.3.4"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T00:00:00Z","timestamp":1791849600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T00:00:00Z","timestamp":1791849600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100014419","name":"EIT Health","doi-asserted-by":"publisher","award":["240037"],"award-info":[{"award-number":["240037"]}],"id":[{"id":"10.13039\/100014419","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["npj Digit. Med."],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Medical AI requires governance preserving safety during continuous improvement. FDA Predetermined Change Control Plans (PCCP) and EU post-market surveillance address iterative updates but lack operational tooling. We present AEGIS, an internal governance and post-market-monitoring infrastructure designed to support the documentation of predetermined governance pathways for PCCP and Medical Devices Regulation alignment. AEGIS comprises dataset assimilation and retraining, model monitoring, and conditional decision-making modules. It utilizes a four-category taxonomy (APPROVE, CONDITIONAL APPROVAL, CLINICAL REVIEW, REJECT) and an independent ALARM\u00a0signal. Instantiating AEGIS for sepsis prediction (PhysioNet) and brain-tumor segmentation (BraTS) exercised all decision categories, successfully routing failures to the critical REJECT\u00a0+\u00a0ALARM state (no deployable model; released model at risk). On real cross-site data, drift detection ROC-AUC rose from 0.82 to 1.00, reliably triggering near 500-patient batches with zero false alarms. This proof-of-concept utilizes illustrative clinical models; drift scoring quantifies covariate shift only, leaving concept drift for future work.<\/jats:p>","DOI":"10.1038\/s41746-026-03290-1","type":"journal-article","created":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T21:42:57Z","timestamp":1791927777000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["AEGIS: an operational infrastructure for post-market governance of adaptive medical AI under US and EU regulatory frameworks"],"prefix":"10.1038","volume":"9","author":[{"given":"Fardin","family":"Afdideh","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mehdi","family":"Astaraki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fernando","family":"Seoane","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Farhad","family":"Abtahi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,10,13]]},"reference":[{"key":"3290_CR1","doi-asserted-by":"publisher","first-page":"328","DOI":"10.1038\/s41746-025-01717-9","volume":"8","author":"B Babic","year":"2025","unstructured":"Babic, B., Glenn Cohen, I., Stern, A. D., Li, Y. & Ouellet, M. A general framework for governing marketed AI\/ML medical devices. npj Digit. Med. 8, 328 (2025).","journal-title":"npj Digit. Med."},{"key":"3290_CR2","unstructured":"U.S. Food and Drug Administration. Artificial intelligence-enabled medical devices. https:\/\/www.fda.gov\/medical-devices\/software-medical-device-samd\/artificial-intelligence-enabled-medical-devices."},{"key":"3290_CR3","unstructured":"U.S. Food and Drug Administration. Proposed regulatory framework for modifications to artificial intelligence\/machine learning (AI\/ML)-based software as a medical device (SaMD)\u2014discussion paper and request for feedback. https:\/\/www.fda.gov\/media\/122535\/download."},{"key":"3290_CR4","unstructured":"U.S. Food and Drug Administration. Marketing submission recommendations for a predetermined change control plan for artificial intelligence-enabled device software functions. https:\/\/www.fda.gov\/regulatory-information\/search-fda-guidance-documents\/marketing-submission-recommendations-predetermined-change-control-plan-artificial-intelligence."},{"key":"3290_CR5","unstructured":"U.S. Food and Drug Administration. Premarket Notification 510(k). https:\/\/www.fda.gov\/medical-devices\/premarket-submissions-selecting-and-preparing-correct-submission\/premarket-notification-510k."},{"key":"3290_CR6","unstructured":"U.S. Food and Drug Administration. De Novo Classification Request. https:\/\/www.fda.gov\/medical-devices\/premarket-submissions-selecting-and-preparing-correct-submission\/de-novo-classification-request."},{"key":"3290_CR7","unstructured":"U.S. Food and Drug Administration. Premarket Approval (PMA). https:\/\/www.fda.gov\/medical-devices\/premarket-submissions-selecting-and-preparing-correct-submission\/premarket-approval-pma."},{"key":"3290_CR8","unstructured":"European Parliament and of the Council. Regulation (EU) 2024\/1689 of the European Parliament and of the Council of 13 June 2024 laying down harmonised rules on artificial intelligence and amending regulations (EC) no 300\/2008, (EU) no 167\/2013, (EU) no 168\/2013, (EU) 2018\/858, (EU) 2018\/1139 and (EU) 2019\/2144 and directives 2014\/90\/EU, (EU) 2016\/797 and (EU) 2020\/1828 (artificial intelligence act) (text with EEA relevance). http:\/\/data.europa.eu\/eli\/reg\/2024\/1689\/oj. Official Journal of the European Union."},{"key":"3290_CR9","unstructured":"European Commission, Directorate-General for Health and Food Safety. MDCG 2025-6 - FAQ on interplay between the medical devices regulation & in vitro diagnostic medical devices regulation and the artificial intelligence act (June 2025). https:\/\/health.ec.europa.eu\/latest-updates\/mdcg-2025-6-faq-interplay-between-medical-devices-regulation-vitro-diagnostic-medical-devices-2025-06-19_en."},{"key":"3290_CR10","unstructured":"U.S. Food and Drug Administration. Good machine learning practice for medical device development: Guiding principles. https:\/\/www.fda.gov\/medical-devices\/software-medical-device-samd\/good-machine-learning-practice-medical-device-development-guiding-principles."},{"key":"3290_CR11","volume":"12","author":"J Li","year":"2026","unstructured":"Li, J., Zhou, Z.-C., Wang, Z.-C. & Lv, H. Prioritizing human-AI collaboration in healthcare: the TRIAD framework for trustworthy governance, real-world, and integrated adaptive deployment. Mil. Med. Res. 12, 97 (2026).","journal-title":"Mil. Med. Res."},{"key":"3290_CR12","doi-asserted-by":"publisher","DOI":"10.1093\/gigascience\/giad108","volume":"12","author":"A Akshay","year":"2023","unstructured":"Akshay, A. et al. MLcps: machine learning cumulative performance score for classification problems. Gigascience 12, giad108. https:\/\/doi.org\/10.1093\/gigascience\/giad108 (2023).","journal-title":"Gigascience"},{"key":"3290_CR13","unstructured":"U.S. Food and Drug Administration. Predetermined change control plans for machine learning-enabled medical devices: Guiding principles. https:\/\/www.fda.gov\/medical-devices\/software-medical-device-samd\/predetermined-change-control-plans-machine-learning-enabled-medical-devices-guiding-principles."},{"key":"3290_CR14","doi-asserted-by":"publisher","first-page":"1631","DOI":"10.1093\/jamia\/ocac078","volume":"29","author":"AD Bedoya","year":"2022","unstructured":"Bedoya, A. D. et al. A framework for the oversight and local deployment of safe and high-quality prediction models. J. Am. Med. Inform. Assoc. 29, 1631\u20131636 (2022).","journal-title":"J. Am. Med. Inform. Assoc."},{"key":"3290_CR15","unstructured":"U.S. Food and Drug Administration. Blog: A lifecycle management approach toward delivering safe, effective AI-enabled health care. https:\/\/www.fda.gov\/medical-devices\/digital-health-center-excellence\/blog-lifecycle-management-approach-toward-delivering-safe-effective-ai-enabled-health-care."},{"key":"3290_CR16","doi-asserted-by":"crossref","unstructured":"Abtahi, F., Seoane, F., Pau, I. & Vega-Barbas, M. Data poisoning vulnerabilities across health care artificial intelligence architectures: analytical security framework and defense strategies. J. Med. Internet Res. 28, e87969 (2026). https:\/\/www.jmir.org\/2026\/1\/e87969.","DOI":"10.2196\/87969"},{"key":"3290_CR17","doi-asserted-by":"crossref","unstructured":"Abtahi, F., Astaraki, M. & Seoane, F. Leveraging imperfection with MEDLEY: a multi-model approach harnessing bias in medical AI. Front. Artif. Intell. 9, 1701665 https:\/\/www.frontiersin.org\/journals\/artificial-intelligence\/articles\/10.3389\/frai.2026.1701665\/full (2026).","DOI":"10.3389\/frai.2026.1701665"},{"key":"3290_CR18","doi-asserted-by":"crossref","unstructured":"Abdul Razak, M. S., Nirmala, C. R., Sreenivasa, B. R., Lahza, H. & Lahza, H. F. M. A survey on detecting healthcare concept drift in AI\/ML models from a finance perspective. Front. Artif. Intell. 5, 955314 (2023).","DOI":"10.3389\/frai.2022.955314"},{"key":"3290_CR19","unstructured":"European Parliament and of the Council. Regulation (EU) 2017\/745 of the European Parliament and of the Council of 5 April 2017 on medical devices, amending directive 2001\/83\/EC, regulation (EC) no 178\/2002 and regulation (EC) no 1223\/2009 and repealing Council Directives 90\/385\/EEC and 93\/42\/EEC (text with EEA relevance). http:\/\/data.europa.eu\/eli\/reg\/2017\/745\/oj. Off. J. Eur. Union."},{"key":"3290_CR20","doi-asserted-by":"publisher","first-page":"437","DOI":"10.1175\/1520-0477(1996)077<0437:TNYRP>2.0.CO;2","volume":"77","author":"E Kalnay","year":"1996","unstructured":"Kalnay, E. et al. The NCEP\/NCAR 40-year reanalysis project. Bull. Am. Meteorol. Soc. 77, 437\u2013472 (1996).","journal-title":"Bull. Am. Meteorol. Soc."},{"key":"3290_CR21","unstructured":"International Organization for Standardization. ISO 14971:2019\u2014medical devices\u2014application of risk management to medical devices. https:\/\/www.iso.org\/standard\/72704.html."},{"key":"3290_CR22","doi-asserted-by":"publisher","first-page":"210","DOI":"10.1097\/CCM.0000000000004145","volume":"48","author":"MA Reyna","year":"2020","unstructured":"Reyna, M. A. et al. Early prediction of sepsis from clinical data: the PhysioNet\/computing in cardiology challenge 2019. Crit. Care Med. 48, 210 (2020).","journal-title":"Crit. Care Med."},{"key":"3290_CR23","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1023\/A:1010933404324","volume":"45","author":"L Breiman","year":"2001","unstructured":"Breiman, L. Random Forests. Mach. Learn. 45, 5\u201332, https:\/\/doi.org\/10.1023\/A:1010933404324 (2001).","journal-title":"Mach. Learn."},{"key":"3290_CR24","doi-asserted-by":"publisher","first-page":"2005","DOI":"10.1111\/jocn.17061","volume":"33","author":"WL Chua","year":"2024","unstructured":"Chua, W. L., Rusli, K. D. B. & Aitken, L. M. Early warning scores for sepsis identification and prediction of in-hospital mortality in adults with sepsis: a systematic review and meta-analysis. J. Clin. Nurs. 33, 2005\u20132018, https:\/\/doi.org\/10.1111\/jocn.17061 (2024).","journal-title":"J. Clin. Nurs."},{"key":"3290_CR25","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1038\/s41746-025-01587-1","volume":"8","author":"Z Wang","year":"2025","unstructured":"Wang, Z. et al. A methodological systematic review of validation and performance of sepsis real-time prediction models. npj Digit. Med. 8, 190 (2025).","journal-title":"npj Digit. Med."},{"key":"3290_CR26","doi-asserted-by":"publisher","unstructured":"Lundberg, S. M. & Lee, S.-I. A unified approach to interpreting model predictions. In: Proc. 31st International Conference on Neural Information Processing Systems 4768\u20134777 https:\/\/doi.org\/10.5555\/3295222.3295230 (2017).","DOI":"10.5555\/3295222.3295230"},{"key":"3290_CR27","doi-asserted-by":"publisher","first-page":"20220878","DOI":"10.1259\/bjr.20220878","volume":"96","author":"B Sahiner","year":"2023","unstructured":"Sahiner, B., Chen, W., Samala, R. K. & Petrick, N. Data drift in medical machine learning: implications and potential remedies. Br. J. Radiol. 96, 20220878, https:\/\/doi.org\/10.1259\/bjr.20220878 (2023).","journal-title":"Br. J. Radiol."},{"key":"3290_CR28","doi-asserted-by":"publisher","first-page":"1993","DOI":"10.1109\/TMI.2014.2377694","volume":"34","author":"BH Menze","year":"2015","unstructured":"Menze, B. H. et al. The Multimodal Brain Tumor Image Segmentation Benchmark (BRATS). IEEE Trans. Med. Imaging 34, 1993\u20132024 (2015).","journal-title":"IEEE Trans. Med. Imaging"},{"key":"3290_CR29","unstructured":"Bakas, S. et al. Identifying the best machine learning algorithms for brain tumor segmentation, progression assessment, and overall survival prediction in the BRATS challenge. http:\/\/arxiv.org\/abs\/1811.02629 (2018)."},{"key":"3290_CR30","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1038\/s41592-020-01008-z","volume":"18","author":"F Isensee","year":"2021","unstructured":"Isensee, F., Jaeger, P. F., Kohl, S. A. A., Petersen, J. & Maier-Hein, K. H. nnU-net: a self-configuring method for deep learning-based biomedical image segmentation. Nat. Methods 18, 203\u2013211 (2021).","journal-title":"Nat. Methods"}],"container-title":["npj Digital Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41746-026-03290-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41746-026-03290-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41746-026-03290-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T21:44:05Z","timestamp":1791927845000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41746-026-03290-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,13]]},"references-count":30,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["3290"],"URL":"https:\/\/doi.org\/10.1038\/s41746-026-03290-1","relation":{},"ISSN":["2398-6352"],"issn-type":[{"value":"2398-6352","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,13]]},"assertion":[{"value":"23 March 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 September 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 October 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"789"}}