{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T11:53:42Z","timestamp":1788263622605,"version":"build-2803163510"},"reference-count":130,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,3,2]],"date-time":"2023-03-02T00:00:00Z","timestamp":1677715200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,3,2]],"date-time":"2023-03-02T00:00:00Z","timestamp":1677715200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Commun Biol"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Sensitive and rapid point-of-care assays have been crucial in the global response to SARS-CoV-2. Loop-mediated isothermal amplification (LAMP) has emerged as an important diagnostic tool given its simplicity and minimal equipment requirements, although limitations exist regarding sensitivity and the methods used to detect reaction products. We describe the development of Vivid COVID-19 LAMP, which leverages a metallochromic detection system utilizing zinc ions and a zinc sensor, 5-Br-PAPS, to circumvent the limitations of classic detection systems dependent on pH indicators or magnesium chelators. We make important strides in improving RT-LAMP sensitivity by establishing principles for using LNA-modified LAMP primers, multiplexing, and conducting extensive optimizations of reaction parameters. To enable point-of-care testing, we introduce a rapid sample inactivation procedure without RNA extraction that is compatible with self-collected, non-invasive gargle samples. Our quadruplexed assay (targeting E, N, ORF1a, and RdRP) reliably detects 1 RNA copy\/\u00b5l of sample (=8 copies\/reaction) from extracted RNA and 2 RNA copies\/\u00b5l of sample (=16 copies\/reaction) directly from gargle samples, making it one of the most sensitive RT-LAMP tests and even comparable to RT-qPCR. Additionally, we demonstrate a self-contained, mobile version of our assay in a variety of high-throughput field testing scenarios on nearly 9,000 crude gargle samples. Vivid COVID-19 LAMP can be an important asset for the endemic phase of COVID-19 as well as preparing for future pandemics.<\/jats:p>","DOI":"10.1038\/s42003-023-04612-9","type":"journal-article","created":{"date-parts":[[2023,3,2]],"date-time":"2023-03-02T11:10:55Z","timestamp":1677755455000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Vivid COVID-19 LAMP is an ultrasensitive, quadruplexed test using LNA-modified primers and a zinc ion and 5-Br-PAPS colorimetric detection system"],"prefix":"10.1038","volume":"6","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4543-7954","authenticated-orcid":false,"given":"Adri\u00e1n","family":"Szobi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5223-3461","authenticated-orcid":false,"given":"Katar\u00edna","family":"Buranovsk\u00e1","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nina","family":"Vojta\u0161\u0161\u00e1kov\u00e1","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5654-3504","authenticated-orcid":false,"given":"Daniel","family":"Lov\u00ed\u0161ek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9062-6354","authenticated-orcid":false,"given":"Halil \u00d6nder","family":"\u00d6zba\u015fak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sandra","family":"Szeibeczederov\u00e1","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liudmyla","family":"Kapustian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4419-4786","authenticated-orcid":false,"given":"Zuzana","family":"Hud\u00e1\u010dov\u00e1","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4581-4254","authenticated-orcid":false,"given":"Viera","family":"Kov\u00e1\u010dov\u00e1","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Diana","family":"Drobn\u00e1","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Piotr","family":"Putaj","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7448-8868","authenticated-orcid":false,"given":"Stanislava","family":"B\u00edrov\u00e1","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ivana","family":"\u010cirkov\u00e1","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"\u010carneck\u00fd","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5237-9994","authenticated-orcid":false,"given":"Peter","family":"Kili\u00e1n","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6977-7921","authenticated-orcid":false,"given":"Peter","family":"Jurk\u00e1\u010dek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8725-9362","authenticated-orcid":false,"given":"Vikt\u00f3ria","family":"\u010cabanov\u00e1","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1086-3219","authenticated-orcid":false,"given":"Krist\u00edna","family":"Bor\u0161ov\u00e1","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7617-5067","authenticated-orcid":false,"given":"Monika","family":"Sl\u00e1vikov\u00e1","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Veronika","family":"Va\u0148ov\u00e1","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6931-1224","authenticated-orcid":false,"given":"Boris","family":"Klempa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8806-9958","authenticated-orcid":false,"given":"Pavol","family":"\u010cekan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7011-8050","authenticated-orcid":false,"given":"Evan D.","family":"Paul","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,3,2]]},"reference":[{"key":"4612_CR1","doi-asserted-by":"publisher","first-page":"104500","DOI":"10.1016\/j.jcv.2020.104500","volume":"129","author":"GC Mak","year":"2020","unstructured":"Mak, G. C. et al. Evaluation of rapid antigen test for detection of SARS-CoV-2 virus. J. Clin. Virol. 129, 104500 (2020).","journal-title":"J. Clin. Virol."},{"key":"4612_CR2","doi-asserted-by":"publisher","first-page":"e01438","DOI":"10.1128\/JCM.01438-20","volume":"58","author":"M Nagura-Ikeda","year":"2020","unstructured":"Nagura-Ikeda, M. et al. Clinical evaluation of self-collected saliva by quantitative reverse transcription-PCR (RT-qPCR), direct RT-qPCR, reverse transcription\u2013loop-mediated isothermal amplification, and a rapid antigen test to diagnose COVID-19. J. Clin. Microbiol. 58, e01438\u201320 (2020).","journal-title":"J. Clin. Microbiol."},{"key":"4612_CR3","doi-asserted-by":"publisher","first-page":"1420","DOI":"10.3390\/v12121420","volume":"12","author":"S Yamayoshi","year":"2020","unstructured":"Yamayoshi, S. et al. Comparison of rapid antigen tests for COVID-19. Viruses 12, 1420 (2020).","journal-title":"Viruses"},{"key":"4612_CR4","doi-asserted-by":"publisher","first-page":"104455","DOI":"10.1016\/j.jcv.2020.104455","volume":"129","author":"A Scohy","year":"2020","unstructured":"Scohy, A. et al. Low performance of rapid antigen detection test as frontline testing for COVID-19 diagnosis. J. Clin. Virol. 129, 104455 (2020).","journal-title":"J. Clin. Virol."},{"key":"4612_CR5","doi-asserted-by":"publisher","first-page":"626","DOI":"10.1111\/jam.13647","volume":"124","author":"Y-P Wong","year":"2018","unstructured":"Wong, Y.-P., Othman, S., Lau, Y.-L., Radu, S. & Chee, H.-Y. Loop-mediated isothermal amplification (LAMP): a versatile technique for detection of micro-organisms. J. Appl. Microbiol. 124, 626\u2013643 (2018).","journal-title":"J. Appl. Microbiol."},{"key":"4612_CR6","doi-asserted-by":"publisher","DOI":"10.1186\/s12936-015-0573-y","volume":"14","author":"J Cook","year":"2015","unstructured":"Cook, J. et al. Loop-mediated isothermal amplification (LAMP) for point-of-care detection of asymptomatic low-density malaria parasite carriers in Zanzibar. Malar. J. 14, 43 (2015).","journal-title":"Malar. J."},{"key":"4612_CR7","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1016\/j.ijid.2021.04.018","volume":"107","author":"M Inaba","year":"2021","unstructured":"Inaba, M. et al. Diagnostic accuracy of LAMP versus PCR over the course of SARS-CoV-2 infection. Int. J. Infect. Dis. 107, 195\u2013200 (2021).","journal-title":"Int. J. Infect. Dis."},{"key":"4612_CR8","doi-asserted-by":"publisher","DOI":"10.1186\/s12879-020-05484-8","volume":"20","author":"MF \u00d6sterdahl","year":"2020","unstructured":"\u00d6sterdahl, M. F. et al. Detecting SARS-CoV-2 at point of care: preliminary data comparing loop-mediated isothermal amplification (LAMP) to polymerase chain reaction (PCR). BMC Infect. Dis. 20, 783 (2020).","journal-title":"BMC Infect. Dis."},{"key":"4612_CR9","doi-asserted-by":"publisher","first-page":"228","DOI":"10.7171\/jbt.21-3203-017","volume":"32","author":"KJM Moore","year":"2021","unstructured":"Moore, K. J. M. et al. Loop-mediated isothermal amplification detection of SARS-CoV-2 and myriad other applications. J. Biomol. Tech. 32, 228\u2013275 (2021).","journal-title":"J. Biomol. Tech."},{"key":"4612_CR10","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1080\/14737159.2021.1873769","volume":"21","author":"TJ Moehling","year":"2021","unstructured":"Moehling, T. J., Choi, G., Dugan, L. C., Salit, M. & Meagher, R. J. LAMP diagnostics at the point-of-care: emerging trends and perspectives for the developer community. Expert Rev. Mol. Diagn. 21, 43\u201361 (2021).","journal-title":"Expert Rev. Mol. Diagn."},{"key":"4612_CR11","doi-asserted-by":"publisher","first-page":"E63","DOI":"10.1093\/nar\/28.12.e63","volume":"28","author":"T Notomi","year":"2000","unstructured":"Notomi, T. et al. Loop-mediated isothermal amplification of DNA. Nucleic Acids Res. 28, E63 (2000).","journal-title":"Nucleic Acids Res."},{"key":"4612_CR12","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1006\/mcpr.2002.0415","volume":"16","author":"K Nagamine","year":"2002","unstructured":"Nagamine, K., Hase, T. & Notomi, T. Accelerated reaction by loop-mediated isothermal amplification using loop primers. Mol. Cell Probes 16, 223\u2013229 (2002).","journal-title":"Mol. Cell Probes"},{"key":"4612_CR13","doi-asserted-by":"publisher","DOI":"10.1186\/s13059-021-02387-y","volume":"22","author":"S Sherrill-Mix","year":"2021","unstructured":"Sherrill-Mix, S. et al. Detection of SARS-CoV-2 RNA using RT-LAMP and molecular beacons. Genome Biol. 22, 169 (2021).","journal-title":"Genome Biol."},{"key":"4612_CR14","doi-asserted-by":"publisher","first-page":"e00911","DOI":"10.1128\/mSphere.00911-20","volume":"6","author":"S Bhadra","year":"2021","unstructured":"Bhadra, S., Riedel, T. E., Lakhotia, S., Tran, N. D. & Ellington, A. D. High-surety isothermal amplification and detection of SARS-CoV-2. mSphere 6, e00911\u2013e00920 (2021).","journal-title":"mSphere"},{"key":"4612_CR15","doi-asserted-by":"publisher","first-page":"123644","DOI":"10.1016\/j.talanta.2022.123644","volume":"248","author":"J Talap","year":"2022","unstructured":"Talap, J., Shen, M., Yu, L., Zeng, S. & Cai, S. RT-LAMP assay combining multi-fluorescent probes for SARS-CoV-2 RNA detection and variant differentiation. Talanta 248, 123644 (2022).","journal-title":"Talanta"},{"key":"4612_CR16","doi-asserted-by":"publisher","first-page":"e01583","DOI":"10.1128\/spectrum.01583-21","volume":"10","author":"EC Kline","year":"2022","unstructured":"Kline, E. C. et al. Multiplex target-redundant RT-LAMP for robust detection of SARS-CoV-2 using fluorescent universal displacement probes. Microbiol. Spectr. 10, e01583\u201321 (2022).","journal-title":"Microbiol. Spectr."},{"key":"4612_CR17","doi-asserted-by":"publisher","first-page":"2932","DOI":"10.1039\/D1LC00266J","volume":"21","author":"RRG Soares","year":"2021","unstructured":"Soares, R. R. G. et al. Sample-to-answer COVID-19 nucleic acid testing using a low-cost centrifugal microfluidic platform with bead-based signal enhancement and smartphone read-out. Lab. Chip 21, 2932\u20132944 (2021).","journal-title":"Lab. Chip"},{"key":"4612_CR18","doi-asserted-by":"publisher","first-page":"2370","DOI":"10.1021\/acssensors.2c01023","volume":"7","author":"Z Tang","year":"2022","unstructured":"Tang, Z. et al. SLIDE: saliva-based SARS-CoV-2 self-testing with RT-LAMP in a mobile device. ACS Sens. 7, 2370\u20132378 (2022).","journal-title":"ACS Sens."},{"key":"4612_CR19","doi-asserted-by":"publisher","first-page":"e0234682","DOI":"10.1371\/journal.pone.0234682","volume":"15","author":"LE Lamb","year":"2020","unstructured":"Lamb, L. E., Bartolone, S. N., Ward, E. & Chancellor, M. B. Rapid detection of novel coronavirus\/Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) by reverse transcription-loop-mediated isothermal amplification. PLoS One 15, e0234682 (2020).","journal-title":"PLoS One"},{"key":"4612_CR20","doi-asserted-by":"publisher","first-page":"103736","DOI":"10.1016\/j.ebiom.2021.103736","volume":"75","author":"X Huang","year":"2022","unstructured":"Huang, X., Tang, G., Ismail, N. & Wang, X. Developing RT-LAMP assays for rapid diagnosis of SARS-CoV-2 in saliva. eBioMedicine 75, 103736 (2022).","journal-title":"eBioMedicine"},{"key":"4612_CR21","doi-asserted-by":"publisher","first-page":"975","DOI":"10.1093\/clinchem\/hvaa102","volume":"66","author":"L Yu","year":"2020","unstructured":"Yu, L. et al. Rapid detection of COVID-19 coronavirus using a reverse transcriptional loop-mediated isothermal amplification (RT-LAMP) diagnostic platform. Clin. Chem. 66, 975\u2013977 (2020).","journal-title":"Clin. Chem."},{"key":"4612_CR22","doi-asserted-by":"publisher","first-page":"eabc7075","DOI":"10.1126\/scitranslmed.abc7075","volume":"12","author":"VLD Thi","year":"2020","unstructured":"Thi, V. L. D. et al. A colorimetric RT-LAMP assay and LAMP-sequencing for detecting SARS-CoV-2 RNA in clinical samples. Sci. Transl. Med. 12, eabc7075 (2020).","journal-title":"Sci. Transl. Med."},{"key":"4612_CR23","doi-asserted-by":"publisher","first-page":"3141","DOI":"10.1038\/s41596-021-00546-w","volume":"16","author":"M Alafeef","year":"2021","unstructured":"Alafeef, M., Moitra, P., Dighe, K. & Pan, D. RNA-extraction-free nano-amplified colorimetric test for point-of-care clinical diagnosis of COVID-19. Nat. Protoc. 16, 3141\u20133162 (2021).","journal-title":"Nat. Protoc."},{"key":"4612_CR24","doi-asserted-by":"publisher","first-page":"2107832","DOI":"10.1002\/smll.202107832","volume":"18","author":"H Ye","year":"2022","unstructured":"Ye, H. et al. Plasmonic LAMP: improving the detection specificity and sensitivity for SARS\u2010CoV\u20102 by plasmonic sensing of isothermally amplified nucleic acids. Small 18, 2107832 (2022).","journal-title":"Small"},{"key":"4612_CR25","doi-asserted-by":"publisher","first-page":"581239","DOI":"10.3389\/fcimb.2021.581239","volume":"11","author":"X Chen","year":"2021","unstructured":"Chen, X. et al. Rapid and visual detection of SARS-CoV-2 using multiplex reverse transcription loop-mediated isothermal amplification linked with gold nanoparticle-based lateral flow biosensor. Front. Cell. Infect. Microbiol. 11, 581239 (2021).","journal-title":"Front. Cell. Infect. Microbiol."},{"key":"4612_CR26","doi-asserted-by":"publisher","first-page":"112437","DOI":"10.1016\/j.bios.2020.112437","volume":"166","author":"X Zhu","year":"2020","unstructured":"Zhu, X. et al. Multiplex reverse transcription loop-mediated isothermal amplification combined with nanoparticle-based lateral flow biosensor for the diagnosis of COVID-19. Biosens. Bioelectron. 166, 112437 (2020).","journal-title":"Biosens. Bioelectron."},{"key":"4612_CR27","doi-asserted-by":"publisher","first-page":"e0238612","DOI":"10.1371\/journal.pone.0238612","volume":"15","author":"B Schermer","year":"2020","unstructured":"Schermer, B. et al. Rapid SARS-CoV-2 testing in primary material based on a novel multiplex RT-LAMP assay. PLoS One 15, e0238612 (2020).","journal-title":"PLoS One"},{"key":"4612_CR28","doi-asserted-by":"publisher","first-page":"870","DOI":"10.1038\/s41587-020-0513-4","volume":"38","author":"JP Broughton","year":"2020","unstructured":"Broughton, J. P. et al. CRISPR-Cas12-based detection of SARS-CoV-2. Nat. Biotechnol. 38, 870\u2013874 (2020).","journal-title":"Nat. Biotechnol."},{"key":"4612_CR29","doi-asserted-by":"publisher","first-page":"632646","DOI":"10.3389\/fcimb.2021.632646","volume":"11","author":"I Azmi","year":"2021","unstructured":"Azmi, I. et al. A saliva-based RNA extraction-free workflow integrated with Cas13a for SARS-CoV-2 detection. Front. Cell. Infect. Microbiol. 11, 632646 (2021).","journal-title":"Front. Cell. Infect. Microbiol."},{"key":"4612_CR30","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-021-21996-6","volume":"12","author":"KH Ooi","year":"2021","unstructured":"Ooi, K. H. et al. An engineered CRISPR-Cas12a variant and DNA-RNA hybrid guides enable robust and rapid COVID-19 testing. Nat. Commun. 12, 1739 (2021).","journal-title":"Nat. Commun."},{"key":"4612_CR31","doi-asserted-by":"publisher","first-page":"1492","DOI":"10.1056\/NEJMc2026172","volume":"383","author":"J Joung","year":"2020","unstructured":"Joung, J. et al. Detection of SARS-CoV-2 with SHERLOCK One-Pot Testing. N. Engl. J. Med 383, 1492\u20131494 (2020).","journal-title":"N. Engl. J. Med"},{"key":"4612_CR32","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-020-18615-1","volume":"11","author":"LT Nguyen","year":"2020","unstructured":"Nguyen, L. T., Smith, B. M. & Jain, P. K. Enhancement of trans-cleavage activity of Cas12a with engineered crRNA enables amplified nucleic acid detection. Nat. Commun. 11, 4906 (2020).","journal-title":"Nat. Commun."},{"key":"4612_CR33","doi-asserted-by":"publisher","first-page":"29518","DOI":"10.1073\/pnas.2010254117","volume":"117","author":"A Ramachandran","year":"2020","unstructured":"Ramachandran, A. et al. Electric field-driven microfluidics for rapid CRISPR-based diagnostics and its application to detection of SARS-CoV-2. Proc. Natl Acad. Sci. USA 117, 29518\u201329525 (2020).","journal-title":"Proc. Natl Acad. Sci. USA"},{"key":"4612_CR34","doi-asserted-by":"publisher","first-page":"112766","DOI":"10.1016\/j.bios.2020.112766","volume":"172","author":"R Wang","year":"2021","unstructured":"Wang, R. et al. opvCRISPR: one-pot visual RT-LAMP-CRISPR platform for SARS-cov-2 detection. Biosens. Bioelectron. 172, 112766 (2021).","journal-title":"Biosens. Bioelectron."},{"key":"4612_CR35","doi-asserted-by":"publisher","first-page":"120876","DOI":"10.1016\/j.biomaterials.2021.120876","volume":"274","author":"X Wu","year":"2021","unstructured":"Wu, X. et al. Digital CRISPR-based method for the rapid detection and absolute quantification of nucleic acids. Biomaterials 274, 120876 (2021).","journal-title":"Biomaterials"},{"key":"4612_CR36","doi-asserted-by":"publisher","first-page":"2668","DOI":"10.1111\/jam.15737","volume":"133","author":"CS Misra","year":"2022","unstructured":"Misra, C. S. et al. An improved, simple and field\u2010deployable CRISPR\u2010Cas12a assay for the detection of SARS\u2010CoV \u20102. J. Appl. Microbiol. 133, 2668\u20132677 (2022).","journal-title":"J. Appl. Microbiol."},{"key":"4612_CR37","doi-asserted-by":"publisher","first-page":"e03271","DOI":"10.1128\/JCM.03271-20","volume":"59","author":"L Peto","year":"2021","unstructured":"Peto, L. et al. Diagnosis of SARS-CoV-2 infection with LamPORE, a high-throughput platform combining loop-mediated isothermal amplification and nanopore sequencing. J. Clin. Microbiol 59, e03271\u201320 (2021).","journal-title":"J. Clin. Microbiol"},{"key":"4612_CR38","doi-asserted-by":"publisher","first-page":"877","DOI":"10.1038\/nprot.2008.57","volume":"3","author":"N Tomita","year":"2008","unstructured":"Tomita, N., Mori, Y., Kanda, H. & Notomi, T. Loop-mediated isothermal amplification (LAMP) of gene sequences and simple visual detection of products. Nat. Protoc. 3, 877\u2013882 (2008).","journal-title":"Nat. Protoc."},{"key":"4612_CR39","doi-asserted-by":"publisher","first-page":"773","DOI":"10.1016\/j.cmi.2020.04.001","volume":"26","author":"C Yan","year":"2020","unstructured":"Yan, C. et al. Rapid and visual detection of 2019 novel coronavirus (SARS-CoV-2) by a reverse transcription loop-mediated isothermal amplification assay. Clin. Microbiol. Infect. 26, 773\u2013779 (2020).","journal-title":"Clin. Microbiol. Infect."},{"key":"4612_CR40","doi-asserted-by":"publisher","first-page":"167","DOI":"10.2144\/000113072","volume":"46","author":"M Goto","year":"2009","unstructured":"Goto, M., Honda, E., Ogura, A., Nomoto, A. & Hanaki, K.-I. Colorimetric detection of loop-mediated isothermal amplification reaction by using hydroxy naphthol blue. BioTechniques 46, 167\u2013172 (2009).","journal-title":"BioTechniques"},{"key":"4612_CR41","doi-asserted-by":"publisher","first-page":"801309","DOI":"10.3389\/fmolb.2022.801309","volume":"9","author":"MJ Kellner","year":"2022","unstructured":"Kellner, M. J. et al. A rapid, highly sensitive and open-access SARS-CoV-2 detection assay for laboratory and home testing. Front. Mol. Biosci. 9, 801309 (2022).","journal-title":"Front. Mol. Biosci."},{"key":"4612_CR42","doi-asserted-by":"publisher","first-page":"13063","DOI":"10.1021\/acs.analchem.1c03016","volume":"93","author":"J Song","year":"2021","unstructured":"Song, J. et al. Single- and two-stage, closed-tube, point-of-care, molecular detection of SARS-CoV-2. Anal. Chem. 93, 13063\u201313071 (2021).","journal-title":"Anal. Chem."},{"key":"4612_CR43","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1016\/j.ab.2014.12.016","volume":"473","author":"S Miyamoto","year":"2015","unstructured":"Miyamoto, S., Sano, S., Takahashi, K. & Jikihara, T. Method for colorimetric detection of double-stranded nucleic acid using leuco triphenylmethane dyes. Anal. Biochem. 473, 28\u201333 (2015).","journal-title":"Anal. Biochem."},{"key":"4612_CR44","doi-asserted-by":"publisher","first-page":"729","DOI":"10.1016\/j.jmoldx.2020.03.006","volume":"22","author":"G-S Park","year":"2020","unstructured":"Park, G.-S. et al. Development of reverse transcription loop-mediated isothermal amplification assays targeting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). J. Mol. Diagn. 22, 729\u2013735 (2020).","journal-title":"J. Mol. Diagn."},{"key":"4612_CR45","doi-asserted-by":"publisher","first-page":"59","DOI":"10.2144\/000114253","volume":"58","author":"NA Tanner","year":"2015","unstructured":"Tanner, N. A., Zhang, Y. & Evans, T. C. Visual detection of isothermal nucleic acid amplification using pH-sensitive dyes. Biotechniques 58, 59\u201368 (2015).","journal-title":"Biotechniques"},{"key":"4612_CR46","doi-asserted-by":"publisher","first-page":"950","DOI":"10.1111\/1751-7915.13586","volume":"13","author":"WE Huang","year":"2020","unstructured":"Huang, W. E. et al. RT\u2010LAMP for rapid diagnosis of coronavirus SARS\u2010CoV\u20102. Microb. Biotechnol. 13, 950\u2013961 (2020).","journal-title":"Microb. Biotechnol."},{"key":"4612_CR47","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-022-06632-7","volume":"12","author":"G Papadakis","year":"2022","unstructured":"Papadakis, G. et al. Portable real-time colorimetric LAMP-device for rapid quantitative detection of nucleic acids in crude samples. Sci. Rep. 12, 3775 (2022).","journal-title":"Sci. Rep."},{"key":"4612_CR48","doi-asserted-by":"publisher","first-page":"104764","DOI":"10.1016\/j.jcv.2021.104764","volume":"136","author":"JJ Schellenberg","year":"2021","unstructured":"Schellenberg, J. J., Ormond, M. & Keynan, Y. Extraction-free RT-LAMP to detect SARS-CoV-2 is less sensitive but highly specific compared to standard RT-PCR in 101 samples. J. Clin. Virol. 136, 104764 (2021).","journal-title":"J. Clin. Virol."},{"key":"4612_CR49","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-95607-1","volume":"11","author":"B Lim","year":"2021","unstructured":"Lim, B. et al. Clinical validation of optimised RT-LAMP for the diagnosis of SARS-CoV-2 infection. Sci. Rep. 11, 16193 (2021).","journal-title":"Sci. Rep."},{"key":"4612_CR50","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1007\/s42242-020-00075-7","volume":"3","author":"Z Cui","year":"2020","unstructured":"Cui, Z. et al. Development of a rapid test kit for SARS-CoV-2: an example of product design. Bio Des. Manuf. 3, 83\u201386 (2020).","journal-title":"Bio Des. Manuf."},{"key":"4612_CR51","doi-asserted-by":"publisher","first-page":"998","DOI":"10.1080\/22221751.2020.1756698","volume":"9","author":"YH Baek","year":"2020","unstructured":"Baek, Y. H. et al. Development of a reverse transcription-loop-mediated isothermal amplification as a rapid early-detection method for novel SARS-CoV-2. Emerg. Microbes Infect. 9, 998\u20131007 (2020).","journal-title":"Emerg. Microbes Infect."},{"key":"4612_CR52","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-020-18130-3","volume":"11","author":"MA Crone","year":"2020","unstructured":"Crone, M. A. et al. A role for Biofoundries in rapid development and validation of automated SARS-CoV-2 clinical diagnostics. Nat. Commun. 11, 4464 (2020).","journal-title":"Nat. Commun."},{"key":"4612_CR53","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-81487-y","volume":"11","author":"S Wei","year":"2021","unstructured":"Wei, S. et al. Direct diagnostic testing of SARS-CoV-2 without the need for prior RNA extraction. Sci. Rep. 11, 2402 (2021).","journal-title":"Sci. Rep."},{"key":"4612_CR54","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-022-11144-5","volume":"12","author":"X Song","year":"2022","unstructured":"Song, X. et al. A lyophilized colorimetric RT-LAMP test kit for rapid, low-cost, at-home molecular testing of SARS-CoV-2 and other pathogens. Sci. Rep. 12, 7043 (2022).","journal-title":"Sci. Rep."},{"key":"4612_CR55","doi-asserted-by":"publisher","first-page":"24450","DOI":"10.1073\/pnas.2011221117","volume":"117","author":"BA Rabe","year":"2020","unstructured":"Rabe, B. A. & Cepko, C. SARS-CoV-2 detection using isothermal amplification and a rapid, inexpensive protocol for sample inactivation and purification. Proc. Natl Acad. Sci. USA 117, 24450\u201324458 (2020).","journal-title":"Proc. Natl Acad. Sci. USA"},{"key":"4612_CR56","doi-asserted-by":"publisher","first-page":"e0250202","DOI":"10.1371\/journal.pone.0250202","volume":"16","author":"C Uribe-Alvarez","year":"2021","unstructured":"Uribe-Alvarez, C., Lam, Q., Baldwin, D. A. & Chernoff, J. Low saliva pH can yield false positives results in simple RT-LAMP-based SARS-CoV-2 diagnostic tests. PLoS One 16, e0250202 (2021).","journal-title":"PLoS One"},{"key":"4612_CR57","doi-asserted-by":"publisher","first-page":"ofaa631","DOI":"10.1093\/ofid\/ofaa631","volume":"8","author":"MN Anahtar","year":"2021","unstructured":"Anahtar, M. N. et al. Clinical assessment and validation of a rapid and sensitive SARS-CoV-2 test using reverse transcription loop-mediated isothermal amplification without the need for RNA extraction. Open Forum Infect. Dis. 8, ofaa631 (2021).","journal-title":"Open Forum Infect. Dis."},{"key":"4612_CR58","doi-asserted-by":"publisher","first-page":"e65113","DOI":"10.7554\/eLife.65113","volume":"10","author":"Q Yang","year":"2021","unstructured":"Yang, Q. et al. Saliva TwoStep for rapid detection of asymptomatic SARS-CoV-2 carriers. eLife 10, e65113 (2021).","journal-title":"eLife"},{"key":"4612_CR59","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1111\/1751-7915.13737","volume":"14","author":"M Jan\u00edkov\u00e1","year":"2021","unstructured":"Jan\u00edkov\u00e1, M., Hodosy, J., Boor, P., Klempa, B. & Celec, P. Loop\u2010mediated isothermal amplification for the detection of SARS\u2010CoV\u20102 in saliva. Microb. Biotechnol. 14, 307\u2013316 (2021).","journal-title":"Microb. Biotechnol."},{"key":"4612_CR60","doi-asserted-by":"publisher","first-page":"914","DOI":"10.1016\/j.cell.2020.04.011","volume":"181","author":"D Kim","year":"2020","unstructured":"Kim, D. et al. The architecture of SARS-CoV-2 transcriptome. Cell 181, 914\u2013921.e10 (2020).","journal-title":"Cell"},{"key":"4612_CR61","doi-asserted-by":"publisher","DOI":"10.1186\/s12985-020-01395-x","volume":"17","author":"W Hou","year":"2020","unstructured":"Hou, W. Characterization of codon usage pattern in SARS-CoV-2. Virol. J. 17, 138 (2020).","journal-title":"Virol. J."},{"key":"4612_CR62","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1016\/S0890-8508(03)00062-8","volume":"17","author":"D Latorra","year":"2003","unstructured":"Latorra, D. & Arar, K. & Michael Hurley, J. Design considerations and effects of LNA in PCR primers. Mol. Cell. Probes 17, 253\u2013259 (2003).","journal-title":"Mol. Cell. Probes"},{"key":"4612_CR63","doi-asserted-by":"publisher","first-page":"481","DOI":"10.1042\/bj3540481","volume":"354","author":"U Christensen","year":"2001","unstructured":"Christensen, U., Jacobsen, N., RAJWANSHI, V., Wengel, J. & Koch, T. Stopped-flow kinetics of locked nucleic acid (LNA) - Oligonucleotide duplex formation: Studies of LNA-DNA and DNA-DNA interactions. Biochem. J. 354, 481\u2013484 (2001).","journal-title":"Biochem. J."},{"key":"4612_CR64","doi-asserted-by":"publisher","first-page":"178","DOI":"10.2144\/btn-2020-0078","volume":"69","author":"Y Zhang","year":"2020","unstructured":"Zhang, Y. et al. Enhancing colorimetric loop-mediated isothermal amplification speed and sensitivity with guanidine chloride. BioTechniques 69, 178\u2013185 (2020).","journal-title":"BioTechniques"},{"key":"4612_CR65","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1093\/clinchem\/hvaa267","volume":"67","author":"MA Lalli","year":"2021","unstructured":"Lalli, M. A. et al. Rapid and extraction-free detection of SARS-CoV-2 from saliva by colorimetric reverse-transcription loop-mediated isothermal amplification. Clin. Chem. 67, 415\u2013424 (2021).","journal-title":"Clin. Chem."},{"key":"4612_CR66","doi-asserted-by":"publisher","first-page":"eabj1281","DOI":"10.1126\/sciadv.abj1281","volume":"7","author":"N Panpradist","year":"2021","unstructured":"Panpradist, N. et al. Harmony COVID-19: a ready-to-use kit, low-cost detector, and smartphone app for point-of-care SARS-CoV-2 RNA detection. Sci. Adv. 7, eabj1281 (2021).","journal-title":"Sci. Adv."},{"key":"4612_CR67","doi-asserted-by":"publisher","first-page":"e0248042","DOI":"10.1371\/journal.pone.0248042","volume":"16","author":"WS Jang","year":"2021","unstructured":"Jang, W. S. et al. Development of a multiplex Loop-Mediated Isothermal Amplification (LAMP) assay for on-site diagnosis of SARS CoV-2. PLoS One 16, e0248042 (2021).","journal-title":"PLoS One"},{"key":"4612_CR68","doi-asserted-by":"publisher","first-page":"e0244882","DOI":"10.1371\/journal.pone.0244882","volume":"15","author":"DM Dudley","year":"2020","unstructured":"Dudley, D. M. et al. Optimizing direct RT-LAMP to detect transmissible SARS-CoV-2 from primary nasopharyngeal swab samples. PLoS One 15, e0244882 (2020).","journal-title":"PLoS One"},{"key":"4612_CR69","doi-asserted-by":"publisher","first-page":"465","DOI":"10.1038\/s41586-020-2196-x","volume":"581","author":"R W\u00f6lfel","year":"2020","unstructured":"W\u00f6lfel, R. et al. Virological assessment of hospitalized patients with COVID-2019. Nature 581, 465\u2013469 (2020).","journal-title":"Nature"},{"key":"4612_CR70","doi-asserted-by":"publisher","first-page":"102","DOI":"10.7171\/jbt.21-3203-005","volume":"32","author":"AD Yu","year":"2021","unstructured":"Yu, A. D. et al. Development of a saliva-optimized RT-LAMP assay for SARS-CoV-2. J. Biomol. Tech. 32, 102\u2013113 (2021).","journal-title":"J. Biomol. Tech."},{"key":"4612_CR71","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-84792-8","volume":"11","author":"S Wei","year":"2021","unstructured":"Wei, S. et al. Field-deployable, rapid diagnostic testing of saliva for SARS-CoV-2. Sci. Rep. 11, 5448 (2021).","journal-title":"Sci. Rep."},{"key":"4612_CR72","doi-asserted-by":"publisher","first-page":"1051","DOI":"10.1021\/ja01939a010","volume":"31","author":"RW Langley","year":"1909","unstructured":"Langley, R. W. On the gravimetric determination of zinc as pyrophosphate. J. Am. Chem. Soc. 31, 1051\u20131052 (1909).","journal-title":"J. Am. Chem. Soc."},{"key":"4612_CR73","doi-asserted-by":"crossref","unstructured":"Wang, J., Niu, Y., Zhang, C. & Chen, Y. A micro-plate colorimetric assay for rapid determination of trace zinc in animal feed, pet food and drinking water by ion masking and statistical partitioning correction. Food Chem. 245, 337\u2013345 (2017).","DOI":"10.1016\/j.foodchem.2017.10.054"},{"key":"4612_CR74","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1007\/s00414-020-02363-4","volume":"135","author":"A Kuffel","year":"2021","unstructured":"Kuffel, A., Gray, A. & Daeid, N. N. Impact of metal ions on PCR inhibition and RT-PCR efficiency. Int J. Leg. Med. 135, 63\u201372 (2021).","journal-title":"Int J. Leg. Med."},{"key":"4612_CR75","doi-asserted-by":"publisher","first-page":"3343","DOI":"10.1093\/nar\/23.16.3343","volume":"23","author":"E Chevet","year":"1995","unstructured":"Chevet, E., Lemaitre, G. & Katinka, M. Low concentration of tetramethylammonium chloride increase yield and specificity of PCR. Nucleic Acids Res. 23, 3343\u20133344 (1995).","journal-title":"Nucleic Acids Res."},{"key":"4612_CR76","doi-asserted-by":"publisher","unstructured":"Ladha, A., Joung, J., Abudayyeh, O., Gootenberg, J. & Zhang, F. A 5-min RNA preparation method for COVID-19 detection with RT-qPCR. medRxiv https:\/\/doi.org\/10.1101\/2020.05.07.20055947 (2020).","DOI":"10.1101\/2020.05.07.20055947"},{"key":"4612_CR77","doi-asserted-by":"publisher","first-page":"160","DOI":"10.1186\/s12985-020-01435-6","volume":"17","author":"L Mautner","year":"2020","unstructured":"Mautner, L. et al. Rapid point-of-care detection of SARS-CoV-2 using reverse transcription loop-mediated isothermal amplification (RT-LAMP). Virol. J. 17, 160 (2020).","journal-title":"Virol. J."},{"key":"4612_CR78","doi-asserted-by":"publisher","first-page":"104760","DOI":"10.1016\/j.jcv.2021.104760","volume":"136","author":"W Yamazaki","year":"2021","unstructured":"Yamazaki, W., Matsumura, Y., Thongchankaew-Seo, U., Yamazaki, Y. & Nagao, M. Development of a point-of-care test to detect SARS-CoV-2 from saliva which combines a simple RNA extraction method with colorimetric reverse transcription loop-mediated isothermal amplification detection. J. Clin. Virol. 136, 104760 (2021).","journal-title":"J. Clin. Virol."},{"key":"4612_CR79","doi-asserted-by":"publisher","first-page":"3747","DOI":"10.1039\/c4cc00540f","volume":"50","author":"K Hsieh","year":"2014","unstructured":"Hsieh, K., Mage, P. L., Csordas, A. T., Eisenstein, M. & Soh, H. T. Simultaneous elimination of carryover contamination and detection of DNA with uracil-DNA-glycosylase-supplemented loop-mediated isothermal amplification (UDG-LAMP). Chem. Commun. 50, 3747\u20133749 (2014).","journal-title":"Chem. Commun."},{"key":"4612_CR80","doi-asserted-by":"publisher","unstructured":"Ranoa, D. R. E. et al. Saliva-based molecular testing for SARS-CoV-2 that bypasses RNA Extraction. bioRxiv https:\/\/doi.org\/10.1101\/2020.06.18.159434 (2020).","DOI":"10.1101\/2020.06.18.159434"},{"key":"4612_CR81","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-022-08263-4","volume":"12","author":"RE Dewhurst","year":"2022","unstructured":"Dewhurst, R. E. et al. Validation of a rapid, saliva-based, and ultra-sensitive SARS-CoV-2 screening system for pandemic-scale infection surveillance. Sci. Rep. 12, 5936 (2022).","journal-title":"Sci. Rep."},{"key":"4612_CR82","doi-asserted-by":"publisher","first-page":"1995","DOI":"10.1111\/1751-7915.14031","volume":"15","author":"M Radv\u00e1nszka","year":"2022","unstructured":"Radv\u00e1nszka, M. et al. Sequential development of several RT\u2010qPCR tests using LNA nucleotides and dual probe technology to differentiate SARS\u2010CoV\u20102 from influenza A and B. Microb. Biotechnol. 15, 1995\u20132021, https:\/\/doi.org\/10.1111\/1751-7915.14031 (2022).","journal-title":"Microb. Biotechnol."},{"key":"4612_CR83","doi-asserted-by":"publisher","first-page":"189","DOI":"10.2144\/000114275","volume":"58","author":"J Fischbach","year":"2015","unstructured":"Fischbach, J., Xander, N. C., Frohme, M. & Gl\u00f6kler, J. F. Shining a light on LAMP assays\u2013a comparison of LAMP visualization methods including the novel use of berberine. Biotechniques 58, 189\u2013194 (2015).","journal-title":"Biotechniques"},{"key":"4612_CR84","doi-asserted-by":"publisher","first-page":"182","DOI":"10.3390\/biology9080182","volume":"9","author":"R Augustine","year":"2020","unstructured":"Augustine, R. et al. Loop-mediated isothermal amplification (LAMP): a rapid, sensitive, specific, and cost-effective point-of-care test for coronaviruses in the context of COVID-19 Pandemic. Biology 9, 182 (2020).","journal-title":"Biology"},{"key":"4612_CR85","doi-asserted-by":"publisher","first-page":"101101","DOI":"10.1016\/j.eclinm.2021.101101","volume":"40","author":"MM Baba","year":"2021","unstructured":"Baba, M. M. et al. Diagnostic performance of a colorimetric RT -LAMP for the identification of SARS-CoV-2: A multicenter prospective clinical evaluation in sub-Saharan Africa. EClinicalMedicine 40, 101101 (2021).","journal-title":"EClinicalMedicine"},{"key":"4612_CR86","doi-asserted-by":"publisher","first-page":"e704","DOI":"10.1016\/S2666-5247(21)00214-7","volume":"2","author":"WY Au","year":"2021","unstructured":"Au, W. Y. & Cheung, P. P. H. Diagnostic performances of common nucleic acid tests for SARS-CoV-2 in hospitals and clinics: a systematic review and meta-analysis. Lancet Microbe 2, e704\u2013e714 (2021).","journal-title":"Lancet Microbe"},{"key":"4612_CR87","doi-asserted-by":"publisher","first-page":"5388","DOI":"10.1021\/bi035976d","volume":"43","author":"PM McTigue","year":"2004","unstructured":"McTigue, P. M., Peterson, R. J. & Kahn, J. D. Sequence-dependent thermodynamic parameters for locked nucleic acid (LNA)\u2212DNA duplex formation. Biochemistry 43, 5388\u20135405 (2004).","journal-title":"Biochemistry"},{"key":"4612_CR88","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1089\/1545457041526317","volume":"14","author":"JS Jepsen","year":"2004","unstructured":"Jepsen, J. S., S\u00f8rensen, M. D. & Wengel, J. Locked nucleic acid: a potent nucleic acid analog in therapeutics and biotechnology. Oligonucleotides 14, 130\u2013146 (2004).","journal-title":"Oligonucleotides"},{"key":"4612_CR89","doi-asserted-by":"publisher","first-page":"e142","DOI":"10.1093\/nar\/gkl756","volume":"34","author":"JD Levin","year":"2006","unstructured":"Levin, J. D., Fiala, D., Samala, M. F., Kahn, J. D. & Peterson, R. J. Position-dependent effects of locked nucleic acid (LNA) on DNA sequencing and PCR primers. Nucleic Acids Res 34, e142 (2006).","journal-title":"Nucleic Acids Res"},{"key":"4612_CR90","doi-asserted-by":"publisher","first-page":"301","DOI":"10.1016\/j.ygeno.2007.10.016","volume":"91","author":"KN Ballantyne","year":"2008","unstructured":"Ballantyne, K. N., van Oorschot, Ra. H. & Mitchell, R. J. Locked nucleic acids in PCR primers increase sensitivity and performance. Genomics 91, 301\u2013305 (2008).","journal-title":"Genomics"},{"key":"4612_CR91","doi-asserted-by":"publisher","first-page":"e0117852","DOI":"10.1371\/journal.pone.0117852","volume":"10","author":"KE Ocwieja","year":"2015","unstructured":"Ocwieja, K. E. et al. A reverse transcription loop-mediated isothermal amplification assay optimized to detect multiple HIV subtypes. PLoS One 10, e0117852 (2015).","journal-title":"PLoS One"},{"key":"4612_CR92","doi-asserted-by":"publisher","first-page":"e0151654","DOI":"10.1371\/journal.pone.0151654","volume":"11","author":"M Itonaga","year":"2016","unstructured":"Itonaga, M. et al. Novel methodology for rapid detection of KRAS mutation using PNA-LNA mediated loop-mediated isothermal amplification. PLoS One 11, e0151654 (2016).","journal-title":"PLoS One"},{"key":"4612_CR93","doi-asserted-by":"publisher","first-page":"1556","DOI":"10.1038\/s41587-021-00966-9","volume":"39","author":"KU Ludwig","year":"2021","unstructured":"Ludwig, K. U. et al. LAMP-Seq enables sensitive, multiplexed COVID-19 diagnostics using molecular barcoding. Nat. Biotechnol. 39, 1556\u20131562 (2021).","journal-title":"Nat. Biotechnol."},{"key":"4612_CR94","doi-asserted-by":"publisher","unstructured":"Yang, Q. et al. Saliva TwoStep for rapid detection of asymptomatic SARS-CoV-2 carriers. medRxiv https:\/\/doi.org\/10.1101\/2020.07.16.20150250 (2021).","DOI":"10.1101\/2020.07.16.20150250"},{"key":"4612_CR95","doi-asserted-by":"publisher","unstructured":"Flynn, M. J. et al. A simple direct RT-LAMP SARS-CoV-2 saliva diagnostic. medRxiv https:\/\/doi.org\/10.1101\/2020.11.19.20234948 (2021).","DOI":"10.1101\/2020.11.19.20234948"},{"key":"4612_CR96","doi-asserted-by":"publisher","first-page":"3102","DOI":"10.1021\/acsnano.5b07338","volume":"10","author":"J Rodriguez-Manzano","year":"2016","unstructured":"Rodriguez-Manzano, J. et al. Reading out single-molecule digital RNA and DNA isothermal amplification in nanoliter volumes with unmodified camera phones. ACS Nano 10, 3102\u20133113 (2016).","journal-title":"ACS Nano"},{"key":"4612_CR97","doi-asserted-by":"publisher","first-page":"444","DOI":"10.1126\/science.aas8836","volume":"360","author":"C Myhrvold","year":"2018","unstructured":"Myhrvold, C. et al. Field-deployable viral diagnostics using CRISPR-Cas13. Science 360, 444\u2013448 (2018).","journal-title":"Science"},{"key":"4612_CR98","doi-asserted-by":"publisher","first-page":"999","DOI":"10.1038\/s42003-022-03973-x","volume":"5","author":"Y Zhang","year":"2022","unstructured":"Zhang, Y., Hunt, E. A., Tamanaha, E., Corr\u00eaa, I. R. & Tanner, N. A. Improved visual detection of DNA amplification using pyridylazophenol metal sensing dyes. Commun. Biol. 5, 999 (2022).","journal-title":"Commun. Biol."},{"key":"4612_CR99","doi-asserted-by":"publisher","first-page":"296","DOI":"10.1080\/10610270802438853","volume":"21","author":"Z Dai","year":"2009","unstructured":"Dai, Z., Khosla, N. & Canary, J. W. Visible colour displacement sensing system for manganese(II). Supramol. Chem. 21, 296\u2013300 (2009).","journal-title":"Supramol. Chem."},{"key":"4612_CR100","doi-asserted-by":"publisher","first-page":"125","DOI":"10.3934\/biophy.2018.2.125","volume":"5","author":"A Kumar Vashishtha","year":"2018","unstructured":"Kumar Vashishtha, A. & H. Konigsberg, W. The effect of different divalent cations on the kinetics and fidelity of Bacillus stearothermophilus DNA polymerase. AIMS Biophys. 5, 125\u2013143 (2018).","journal-title":"AIMS Biophys."},{"key":"4612_CR101","doi-asserted-by":"publisher","first-page":"5810","DOI":"10.1021\/bi00342a019","volume":"24","author":"RA Beckman","year":"1985","unstructured":"Beckman, R. A., Mildvan, A. S. & Loeb, L. A. On the fidelity of DNA replication: manganese mutagenesis in vitro. Biochemistry 24, 5810\u20135817 (1985).","journal-title":"Biochemistry"},{"key":"4612_CR102","doi-asserted-by":"publisher","first-page":"4076","DOI":"10.1073\/pnas.86.11.4076","volume":"86","author":"S Tabor","year":"1989","unstructured":"Tabor, S. & Richardson, C. C. Effect of manganese ions on the incorporation of dideoxynucleotides by bacteriophage T7 DNA polymerase and Escherichia coli DNA polymerase I. Proc. Natl Acad. Sci. USA 86, 4076\u20134080 (1989).","journal-title":"Proc. Natl Acad. Sci. USA"},{"key":"4612_CR103","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1016\/j.jinf.2020.10.039","volume":"82","author":"VL Fowler","year":"2021","unstructured":"Fowler, V. L. et al. A highly effective reverse-transcription loop-mediated isothermal amplification (RT-LAMP) assay for the rapid detection of SARS-CoV-2 infection. J. Infect. 82, 117\u2013125 (2021).","journal-title":"J. Infect."},{"key":"4612_CR104","doi-asserted-by":"publisher","first-page":"114048","DOI":"10.1016\/j.jviromet.2020.114048","volume":"289","author":"ELA Howson","year":"2021","unstructured":"Howson, E. L. A. et al. Preliminary optimisation of a simplified sample preparation method to permit direct detection of SARS-CoV-2 within saliva samples using reverse-transcription loop-mediated isothermal amplification (RT-LAMP). J. Virol. Methods 289, 114048 (2021).","journal-title":"J. Virol. Methods"},{"key":"4612_CR105","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-020-79237-7","volume":"10","author":"P Subsoontorn","year":"2020","unstructured":"Subsoontorn, P., Lohitnavy, M. & Kongkaew, C. The diagnostic accuracy of isothermal nucleic acid point-of-care tests for human coronaviruses: A systematic review and meta-analysis. Sci. Rep. 10, 22349 (2020).","journal-title":"Sci. Rep."},{"key":"4612_CR106","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-020-80314-0","volume":"11","author":"Y Dong","year":"2021","unstructured":"Dong, Y. et al. Comparative evaluation of 19 reverse transcription loop-mediated isothermal amplification assays for detection of SARS-CoV-2. Sci. Rep. 11, 2936 (2021).","journal-title":"Sci. Rep."},{"key":"4612_CR107","doi-asserted-by":"publisher","first-page":"1021","DOI":"10.1038\/s41587-020-0655-4","volume":"38","author":"MJ MacKay","year":"2020","unstructured":"MacKay, M. J. et al. The COVID-19 XPRIZE and the need for scalable, fast, and widespread testing. Nat. Biotechnol. 38, 1021\u20131024 (2020).","journal-title":"Nat. Biotechnol."},{"key":"4612_CR108","doi-asserted-by":"publisher","first-page":"2001483","DOI":"10.2807\/1560-7917.ES.2020.25.32.2001483","volume":"25","author":"A Singanayagam","year":"2020","unstructured":"Singanayagam, A. et al. Duration of infectiousness and correlation with RT-PCR cycle threshold values in cases of COVID-19, England, January to May 2020. Eur. Surveill. 25, 2001483 (2020).","journal-title":"Eur. Surveill."},{"key":"4612_CR109","doi-asserted-by":"publisher","first-page":"1059","DOI":"10.1007\/s10096-020-03913-9","volume":"39","author":"B La Scola","year":"2020","unstructured":"La Scola, B. et al. Viral RNA load as determined by cell culture as a management tool for discharge of SARS-CoV-2 patients from infectious disease wards. Eur. J. Clin. Microbiol Infect. Dis. 39, 1059\u20131061 (2020).","journal-title":"Eur. J. Clin. Microbiol Infect. Dis."},{"key":"4612_CR110","doi-asserted-by":"publisher","unstructured":"Basile, K. et al. Cell-based culture of SARS-CoV-2 informs infectivity and safe de-isolation assessments during COVID-19. Clin. Infect. Dis. https:\/\/doi.org\/10.1093\/cid\/ciaa1579 (2020).","DOI":"10.1093\/cid\/ciaa1579"},{"key":"4612_CR111","doi-asserted-by":"publisher","first-page":"2663","DOI":"10.1093\/cid\/ciaa638","volume":"71","author":"J Bullard","year":"2020","unstructured":"Bullard, J. et al. Predicting infectious severe acute respiratory syndrome coronavirus 2 from diagnostic samples. Clin. Infect. Dis. 71, 2663\u20132666 (2020).","journal-title":"Clin. Infect. Dis."},{"key":"4612_CR112","doi-asserted-by":"publisher","first-page":"640","DOI":"10.1038\/s41564-022-01105-z","volume":"7","author":"R Ke","year":"2022","unstructured":"Ke, R. et al. Daily longitudinal sampling of SARS-CoV-2 infection reveals substantial heterogeneity in infectiousness. Nat. Microbiol 7, 640\u2013652 (2022).","journal-title":"Nat. Microbiol"},{"key":"4612_CR113","doi-asserted-by":"publisher","unstructured":"Bokelmann, L. et al. Rapid, reliable, and cheap point-of-care bulk testing for SARS-CoV-2 by combining hybridization capture with improved colorimetric LAMP (Cap-iLAMP). https:\/\/protocolexchange.researchsquare.com\/article\/pex-1344\/v1 (2021) https:\/\/doi.org\/10.21203\/rs.3.pex-1344\/v1.","DOI":"10.21203\/rs.3.pex-1344\/v1"},{"key":"4612_CR114","doi-asserted-by":"publisher","first-page":"22727","DOI":"10.1073\/pnas.2014739117","volume":"117","author":"A Ganguli","year":"2020","unstructured":"Ganguli, A. et al. Rapid isothermal amplification and portable detection system for SARS-CoV-2. Proc. Natl Acad. Sci. USA 117, 22727\u201322735 (2020).","journal-title":"Proc. Natl Acad. Sci. USA"},{"key":"4612_CR115","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.ijid.2022.07.042","volume":"123","author":"G Doria","year":"2022","unstructured":"Doria, G. et al. An isothermal lab-on-phone test for easy molecular diagnosis of SARS-CoV-2 near patients and in less than 1\u2009h. Int. J. Infect. Dis. 123, 1\u20138 (2022).","journal-title":"Int. J. Infect. Dis."},{"key":"4612_CR116","doi-asserted-by":"publisher","first-page":"e0243712","DOI":"10.1371\/journal.pone.0243712","volume":"16","author":"P Garneret","year":"2021","unstructured":"Garneret, P. et al. Performing point-of-care molecular testing for SARS-CoV-2 with RNA extraction and isothermal amplification. PLoS ONE 16, e0243712 (2021).","journal-title":"PLoS ONE"},{"key":"4612_CR117","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-021-21361-7","volume":"12","author":"D Butler","year":"2021","unstructured":"Butler, D. et al. Shotgun transcriptome, spatial omics, and isothermal profiling of SARS-CoV-2 infection reveals unique host responses, viral diversification, and drug interactions. Nat. Commun. 12, 1660 (2021).","journal-title":"Nat. Commun."},{"key":"4612_CR118","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-020-80352-8","volume":"11","author":"A Alekseenko","year":"2021","unstructured":"Alekseenko, A. et al. Direct detection of SARS-CoV-2 using non-commercial RT-LAMP reagents on heat-inactivated samples. Sci. Rep. 11, 1820 (2021).","journal-title":"Sci. Rep."},{"key":"4612_CR119","doi-asserted-by":"publisher","first-page":"e387","DOI":"10.1002\/cpz1.387","volume":"2","author":"S Bhadra","year":"2022","unstructured":"Bhadra, S. et al. Preparation and use of cellular reagents: a low\u2010resource molecular biology reagent platform. Curr. Protoc. 2, e387 (2022).","journal-title":"Curr. Protoc."},{"key":"4612_CR120","doi-asserted-by":"publisher","first-page":"e0252507","DOI":"10.1371\/journal.pone.0252507","volume":"16","author":"S Bhadra","year":"2021","unstructured":"Bhadra, S. et al. Producing molecular biology reagents without purification. PLoS One 16, e0252507 (2021).","journal-title":"PLoS One"},{"key":"4612_CR121","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1016\/j.jviromet.2018.02.012","volume":"255","author":"KA Curtis","year":"2018","unstructured":"Curtis, K. A. et al. A multiplexed RT-LAMP assay for detection of group M HIV-1 in plasma or whole blood. J. Virol. Methods 255, 91\u201397 (2018).","journal-title":"J. Virol. Methods"},{"key":"4612_CR122","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-99661-7","volume":"11","author":"K Bor\u0161ov\u00e1","year":"2021","unstructured":"Bor\u0161ov\u00e1, K. et al. Surveillance of SARS-CoV-2 lineage B.1.1.7 in Slovakia using a novel, multiplexed RT-qPCR assay. Sci. Rep. 11, 20494 (2021).","journal-title":"Sci. Rep."},{"key":"4612_CR123","doi-asserted-by":"publisher","first-page":"556","DOI":"10.1007\/s11262-021-01866-5","volume":"57","author":"B Brejov\u00e1","year":"2021","unstructured":"Brejov\u00e1, B. et al. A SARS-CoV-2 mutant from B.1.258 lineage with \u2206H69\/\u2206V70 deletion in the Spike protein circulating in Central Europe in the fall 2020. Virus Genes 57, 556\u2013560 (2021).","journal-title":"Virus Genes"},{"key":"4612_CR124","doi-asserted-by":"publisher","first-page":"2490","DOI":"10.1093\/bioinformatics\/bty121","volume":"34","author":"T Nakamura","year":"2018","unstructured":"Nakamura, T., Yamada, K. D., Tomii, K. & Katoh, K. Parallelization of MAFFT for large-scale multiple sequence alignments. Bioinformatics 34, 2490\u20132492 (2018).","journal-title":"Bioinformatics"},{"key":"4612_CR125","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1093\/molbev\/msp259","volume":"27","author":"M Gouy","year":"2010","unstructured":"Gouy, M., Guindon, S. & Gascuel, O. SeaView Version 4: a multiplatform graphical user interface for sequence alignment and phylogenetic tree building. Mol. Biol. Evol. 27, 221\u2013224 (2010).","journal-title":"Mol. Biol. Evol."},{"key":"4612_CR126","doi-asserted-by":"publisher","unstructured":"Mahony, N. O. et al. Deep learning vs. traditional computer vision. https:\/\/doi.org\/10.48550\/ARXIV.1910.13796 (2019).","DOI":"10.48550\/ARXIV.1910.13796"},{"key":"4612_CR127","doi-asserted-by":"publisher","unstructured":"Chang, F. et al. FacePoseNet: making a case for landmark-free face alignment. https:\/\/doi.org\/10.48550\/ARXIV.1708.07517 (2017).","DOI":"10.48550\/ARXIV.1708.07517"},{"key":"4612_CR128","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1007\/s11263-018-1097-z","volume":"127","author":"Y Wu","year":"2019","unstructured":"Wu, Y. & Ji, Q. Facial landmark detection: a literature survey. Int J. Comput. Vis. 127, 115\u2013142 (2019).","journal-title":"Int J. Comput. Vis."},{"key":"4612_CR129","doi-asserted-by":"publisher","unstructured":"Sekachev, B. et al. opencv\/cvat: v1.1.0. (Zenodo, 2020). https:\/\/doi.org\/10.5281\/ZENODO.4009388.","DOI":"10.5281\/ZENODO.4009388"},{"key":"4612_CR130","doi-asserted-by":"publisher","unstructured":"Sandler, M., Howard, A., Zhu, M., Zhmoginov, A. & Chen, L.-C. MobileNetV2: inverted residuals and linear bottlenecks. https:\/\/doi.org\/10.48550\/ARXIV.1801.04381 (2018).","DOI":"10.48550\/ARXIV.1801.04381"}],"container-title":["Communications Biology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s42003-023-04612-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s42003-023-04612-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s42003-023-04612-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,2]],"date-time":"2023-03-02T12:07:47Z","timestamp":1677758867000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s42003-023-04612-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3,2]]},"references-count":130,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["4612"],"URL":"https:\/\/doi.org\/10.1038\/s42003-023-04612-9","relation":{},"ISSN":["2399-3642"],"issn-type":[{"value":"2399-3642","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,3,2]]},"assertion":[{"value":"20 January 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 February 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 March 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"A.S., K.Bur., N.V., D.L., H.\u00d6.\u00d6., S.S., L.K., V.K., D.D., P.P., S.B., I.\u010c., M.\u010c., P.K., P.\u010c., and E.D.P. are employees of MultiplexDX, a biotechnology company that developed and commercialized the Vivid COVID-19 LAMP Direct G diagnostic kit (, MultiplexDX, s.r.o., Bratislava, Slovakia), which is based on the research presented in the manuscript. P.\u010c., E.D.P., A.S., N.V., and K.Bur. are inventors and MultiplexDX, s.r.o is the assignee on patent applications that were filed in relation to the technology and research outlined in the manuscript. B.K. is a Head of the Department of Virus Ecology, Institute of Virology, Biomedical Research Center of the Slovak Academy of Sciences (BMC SAS). BMC SAS has entered into a collaboration with MultiplexDX, s.r.o. for the development and validation of the RT-LAMP test for routine detection of SARS-CoV-2 that is described in this study. All other authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"233"}}