{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,18]],"date-time":"2026-11-18T00:10:23Z","timestamp":1794960623869,"version":"4.9.1"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2026,3,10]],"date-time":"2026-03-10T00:00:00Z","timestamp":1773100800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,3,10]],"date-time":"2026-03-10T00:00:00Z","timestamp":1773100800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"https:\/\/transform.england.nhs.uk\/ai-lab\/ai-lab-programmes\/ai-health-and-care-award\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Nat Cancer"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Artificial intelligence (AI) tools can improve breast screening performance but different screening sites have varying needs. Here the GEMINI prospective evaluation of 10,889 women, within one UK region, used both live AI integration and simulations to model 17 different ways AI could be used in breast screening. All women received routine care. One AI tool was assessed. When the AI tool recommended recall but routine double reading did not, cases underwent additional human review, detecting 11 additional cancers. The primary AI workflow could improve cancer detection by 10.4% (1 per 1,000), maintain the recall rate (0.8% reduction) and reduce workload by up to 31%. Other workflow variations significantly improved all measured metrics (superiority in cancer detection rate, recall rate, positive predictive value (PPV), sensitivity and specificity) with up to 36% workload savings. Different AI integrations in breast screening could offer various clinical and operational gains, allowing for adaptation to local healthcare needs.<\/jats:p>","DOI":"10.1038\/s43018-026-01126-1","type":"journal-article","created":{"date-parts":[[2026,3,10]],"date-time":"2026-03-10T10:01:24Z","timestamp":1773136884000},"page":"484-493","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Prospective evaluation of artificial intelligence integration into breast cancer screening in multiple workflow settings: the GEMINI study"],"prefix":"10.1038","volume":"7","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9616-4231","authenticated-orcid":false,"given":"Clarisse Florence","family":"de Vries","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7867-5468","authenticated-orcid":false,"given":"Gerald","family":"Lip","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roger Todd","family":"Staff","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jaroslaw Artur","family":"Dymiter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benjamin","family":"Tse","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0016-2275","authenticated-orcid":false,"given":"Annie","family":"Ng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Georgia","family":"Fox","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0749-5117","authenticated-orcid":false,"given":"Cary","family":"Oberije","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1000-3649","authenticated-orcid":false,"given":"Lesley Ann","family":"Anderson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,3,10]]},"reference":[{"key":"1126_CR1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2023.111087","volume":"167","author":"T Van Nijnatten","year":"2023","unstructured":"Van Nijnatten, T., Payne, N. R., Hickman, S. E., Ashrafian, H. & Gilbert, F. J. Overview of trials on artificial intelligence algorithms in breast cancer screening\u2014A roadmap for international evaluation and implementation. Eur. J. Radiol. 167, 111087 (2023).","journal-title":"Eur. J. Radiol."},{"key":"1126_CR2","doi-asserted-by":"publisher","first-page":"e703","DOI":"10.1016\/S2589-7500(23)00153-X","volume":"5","author":"K Dembrower","year":"2023","unstructured":"Dembrower, K., Crippa, A., Col\u00f3n, E., Eklund, M. & Strand, F. Artificial intelligence for breast cancer detection in screening mammography in sweden: a prospective, population-based, paired-reader, non-inferiority study. Lancet Digit. Health 5, e703\u2013e711 (2023).","journal-title":"Lancet Digit. Health"},{"key":"1126_CR3","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.232479","volume":"311","author":"AD Lauritzen","year":"2024","unstructured":"Lauritzen, A. D. et al. Early indicators of the impact of using AI in mammography screening for breast cancer. Radiology 311, e232479 (2024).","journal-title":"Radiology"},{"key":"1126_CR4","doi-asserted-by":"publisher","first-page":"3044","DOI":"10.1038\/s41591-023-02625-9","volume":"29","author":"AY Ng","year":"2023","unstructured":"Ng, A. Y. et al. Prospective implementation of AI-assisted screen reading to improve early detection of breast cancer. Nat. Med. 29, 3044\u20133049 (2023).","journal-title":"Nat. Med."},{"key":"1126_CR5","unstructured":"Sheikh K. A. I. could spot breast cancer earlier. should you pay for it? The New York Times (9 April 2024)."},{"key":"1126_CR6","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.222639","volume":"307","author":"JH Yoon","year":"2023","unstructured":"Yoon, J. H. et al. Standalone AI for breast cancer detection at screening digital mammography and digital breast tomosynthesis: a systematic review and meta-analysis. Radiology 307, e222639 (2023).","journal-title":"Radiology"},{"key":"1126_CR7","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-024-51725-8","volume":"15","author":"HML Frazer","year":"2024","unstructured":"Frazer, H. M. L. et al. Comparison of AI-integrated pathways with human-AI interaction in population mammographic screening for breast cancer. Nat. Commun. 15, 7525 (2024).","journal-title":"Nat. Commun."},{"key":"1126_CR8","doi-asserted-by":"publisher","first-page":"936","DOI":"10.1016\/S1470-2045(23)00298-X","volume":"24","author":"K L\u00e5ng","year":"2023","unstructured":"L\u00e5ng, K. et al. Artificial intelligence-supported screen reading versus standard double reading in the mammography screening with artificial intelligence trial (MASAI): a clinical safety analysis of a randomised, controlled, non-inferiority, single-blinded, screening accuracy study. Lancet Oncol. 24, 936\u2013944 (2023).","journal-title":"Lancet Oncol."},{"key":"1126_CR9","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1177\/09691413211001405","volume":"28","author":"CF de Vries","year":"2021","unstructured":"de Vries, C. F., Morrissey, B. E., Duggan, D., Staff, R. T. & Lip, G. Screening participants\u2019 attitudes to the introduction of artificial intelligence in breast screening. J. Med. Screen. 28, 221\u2013222 (2021).","journal-title":"J. Med. Screen."},{"key":"1126_CR10","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1186\/s13244-022-01322-4","volume":"13","author":"CF de Vries","year":"2022","unstructured":"de Vries, C. F., Morrissey, B. E., Duggan, D., Staff, R. T. & Lip, G. AI in breast screening mammography: breast screening readers\u2019 perspectives. Insights Imaging 13, 186 (2022).","journal-title":"Insights Imaging"},{"key":"1126_CR11","doi-asserted-by":"publisher","DOI":"10.1148\/ryai.220146","volume":"5","author":"CF de Vries","year":"2023","unstructured":"de Vries, C. F. et al. Impact of different mammography systems on artificial intelligence performance in breast cancer screening. Radiol. Artif. Intell. 5, e220146 (2023).","journal-title":"Radiol. Artif. Intell."},{"key":"1126_CR12","doi-asserted-by":"publisher","first-page":"033502","DOI":"10.1117\/1.JMI.8.3.033502","volume":"8","author":"J Boita","year":"2021","unstructured":"Boita, J., Mackenzie, A., Van Engen, R. E., Broeders, M. & Sechopoulos, I. Validation of a mammographic image quality modification algorithm using 3D-printed breast phantoms. J. Med. Imaging 8, 033502 (2021).","journal-title":"J. Med. Imaging"},{"key":"1126_CR13","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1093\/bjr\/tqad024","volume":"97","author":"CF de Vries","year":"2024","unstructured":"de Vries, C. F. et al. Service and clinical impacts of reader bias in breast cancer screening: a retrospective study. Br. J. Radiol. 97, 120\u2013125 (2024).","journal-title":"Br. J. Radiol."},{"key":"1126_CR14","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2024.111535","volume":"177","author":"GJW Partridge","year":"2024","unstructured":"Partridge, G. J. W. et al. How long does it take to read a mammogram? Investigating the reading time of digital breast tomosynthesis and digital mammography. Eur. J. Radiol. 177, 111535 (2024).","journal-title":"Eur. J. Radiol."},{"key":"1126_CR15","unstructured":"The Royal College of Radiologists (RCR). Clinical Radiology Workforce Census 2023 www.rcr.ac.uk\/media\/5befglss\/rcr-census-clinical-radiology-workforce-census-2023.pdf (RCR, 2023)."},{"key":"1126_CR16","doi-asserted-by":"publisher","DOI":"10.1186\/s12885-023-10890-7","volume":"23","author":"N Sharma","year":"2023","unstructured":"Sharma, N. et al. Multi-vendor evaluation of artificial intelligence as an independent reader for double reading in breast cancer screening on 275,900 mammograms. BMC Cancer. 23, 460 (2023).","journal-title":"BMC Cancer."},{"key":"1126_CR17","unstructured":"NHS England. Breast Screening: Reporting, Classification and Monitoring of Interval Cancers and Cancers Following Previous Assessment GOV.UK Web Site. www.gov.uk\/government\/publications\/breast-screening-interval-cancers\/breast-screening-reporting-classification-and-monitoring-of-interval-cancers-and-cancers-following-previous-assessment (NHS England, 2022)."},{"key":"1126_CR18","doi-asserted-by":"publisher","first-page":"3283","DOI":"10.1038\/s41591-025-03953-8","volume":"31","author":"V Sounderajah","year":"2025","unstructured":"Sounderajah, V. et al. The STARD-AI reporting guideline for diagnostic accuracy studies using artificial intelligence. Nat. Med. 31, 3283\u20133289 (2025).","journal-title":"Nat. Med."},{"key":"1126_CR19","unstructured":"R Core Team R: A Language and Environment for Statistical Computing (R Core Team, 2022)."},{"key":"1126_CR20","unstructured":"Canty A. & Ripley B. Boot: Bootstrap R (S-plus) functions. R package version 1.3-18. CRAN https:\/\/cran.r-project.org\/web\/packages\/boot\/boot.pdf (2024)."},{"key":"1126_CR21","doi-asserted-by":"crossref","unstructured":"Davison A. C. & Hinkley D. V. Bootstrap Methods and Their Application (Cambridge Univ. Press, 1997).","DOI":"10.1017\/CBO9780511802843"},{"key":"1126_CR22","doi-asserted-by":"publisher","unstructured":"de Vries C. F. CFdeVries\/gemini-paper: Runnable GEMINI paper R code. Zenodo https:\/\/doi.org\/10.5281\/zenodo.15574461 (2025).","DOI":"10.5281\/zenodo.15574461"}],"container-title":["Nature Cancer"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s43018-026-01126-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s43018-026-01126-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s43018-026-01126-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,30]],"date-time":"2026-03-30T08:55:31Z","timestamp":1774860931000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s43018-026-01126-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,10]]},"references-count":22,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2026,3]]}},"alternative-id":["1126"],"URL":"https:\/\/doi.org\/10.1038\/s43018-026-01126-1","relation":{},"ISSN":["2662-1347"],"issn-type":[{"value":"2662-1347","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,10]]},"assertion":[{"value":"1 October 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 January 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 March 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"A.N., C.O. and G.F. were employees of Kheiron Medical Technologies Ltd. and held stock options as part of the standard compensation package. C.F.d.V., G.L., R.T.S., J.A.D., B.T. and L.A.A. declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}