{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,6]],"date-time":"2026-11-06T13:40:41Z","timestamp":1793972441872,"version":"4.8.0"},"reference-count":49,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,11,25]],"date-time":"2024-11-25T00:00:00Z","timestamp":1732492800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2024,11,25]],"date-time":"2024-11-25T00:00:00Z","timestamp":1732492800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/501100001691","name":"MEXT | Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["19H00672"],"award-info":[{"award-number":["19H00672"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Commun Eng"],"DOI":"10.1038\/s44172-024-00313-1","type":"journal-article","created":{"date-parts":[[2024,11,25]],"date-time":"2024-11-25T05:02:30Z","timestamp":1732510950000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":22,"title":["An energy-resolving photon-counting X-ray detector for computed tomography combining silicon-photomultiplier arrays and scintillation crystals"],"prefix":"10.1038","volume":"3","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4046-0071","authenticated-orcid":false,"given":"Kenji","family":"Shimazoe","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Donghwan","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Moh","family":"Hamdan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yosuke","family":"Kobayashi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kei","family":"Kamada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masao","family":"Yoshino","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yasuhiro","family":"Shoji","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kyohei","family":"Sakamoto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8213-5405","authenticated-orcid":false,"given":"Fabio","family":"Acerbi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alberto","family":"Gola","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,11,25]]},"reference":[{"key":"313_CR1","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1016\/j.ejmp.2020.10.030","volume":"79","author":"T Flohr","year":"2020","unstructured":"Flohr, T. et al. Photon-counting CT review. Phys. Med. 79, 126\u2013136 (2020).","journal-title":"Phys. Med."},{"key":"313_CR2","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1177\/08465371231172738","volume":"75","author":"S Jalal","year":"2024","unstructured":"Jalal, S. & Savvas, N. Advanced imaging technology: photon counting CT. Can. Assoc. Radiol. J. 75, 20\u201321 (2024).","journal-title":"Can. Assoc. Radiol. J."},{"key":"313_CR3","doi-asserted-by":"publisher","first-page":"5578","DOI":"10.1007\/s00330-023-09511-5","volume":"33","author":"A Rau","year":"2023","unstructured":"Rau, A. et al. Photon-counting computed tomography (PCCT) of the spine: impact on diagnostic confidence and radiation dose. Eur. Radiol. 33, 5578\u20135586 (2023).","journal-title":"Eur. Radiol."},{"key":"313_CR4","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1007\/s11694-008-9059-8","volume":"2","author":"RP Haff","year":"2008","unstructured":"Haff, R. P. & Natsuko, T. X-ray detection of defects and contaminants in the food industry. Sens. Instrum. Food Quality Saf. 2, 262\u2013276 (2008).","journal-title":"Sens. Instrum. Food Quality Saf."},{"key":"313_CR5","doi-asserted-by":"publisher","first-page":"031108","DOI":"10.1118\/1.4790692","volume":"40","author":"AM Alessio","year":"2013","unstructured":"Alessio, A. M. & MacDonald, L. R. Quantitative material characterization from multi\u2010energy photon counting CT. Med. Phys. 40, 031108 (2013).","journal-title":"Med. Phys."},{"key":"313_CR6","doi-asserted-by":"publisher","first-page":"1595","DOI":"10.1088\/0031-9155\/57\/6\/1595","volume":"57","author":"PM Shikhaliev","year":"2012","unstructured":"Shikhaliev, P. M. Photon counting spectral CT: improved material decomposition with K-edge-filtered X-rays. Phys. Med. Biol. 57, 1595 (2012).","journal-title":"Phys. Med. Biol."},{"key":"313_CR7","doi-asserted-by":"publisher","first-page":"1249","DOI":"10.1109\/TMI.2013.2250991","volume":"32","author":"CO Schirra","year":"2013","unstructured":"Schirra, C. O. et al. Statistical reconstruction of material decomposed data in spectral CT. IEEE Trans. Med. Imaging 32, 1249\u20131257 (2013).","journal-title":"IEEE Trans. Med. Imaging"},{"key":"313_CR8","doi-asserted-by":"publisher","first-page":"155003","DOI":"10.1088\/1361-6560\/ac7d34","volume":"67","author":"R Nadkarni","year":"2022","unstructured":"Nadkarni, R. et al. Material decomposition from photon-counting CT using a convolutional neural network and energy-integrating CT training labels. Phys. Med. Biol. 67, 155003 (2022).","journal-title":"Phys. Med. Biol."},{"key":"313_CR9","doi-asserted-by":"publisher","first-page":"785","DOI":"10.1097\/RLI.0000000000000789","volume":"56","author":"J-P Grunz","year":"2021","unstructured":"Grunz, J.-P. et al. Image quality assessment for clinical cadmium telluride-based photon-counting computed tomography detector in cadaveric wrist imaging. Investig. Radiol. 56, 785\u2013790 (2021).","journal-title":"Investig. Radiol."},{"key":"313_CR10","doi-asserted-by":"publisher","first-page":"5120","DOI":"10.1002\/mp.12301","volume":"44","author":"R Symons","year":"2017","unstructured":"Symons, R. et al. Photon\u2010counting CT for simultaneous imaging of multiple contrast agents in the abdomen: an in vivo study. Med. Phys. 44, 5120\u20135127 (2017).","journal-title":"Med. Phys."},{"key":"313_CR11","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1148\/radiol.212579","volume":"303","author":"K Rajendran","year":"2022","unstructured":"Rajendran, K. et al. First clinical photon-counting detector CT system: technical evaluation. Radiology 303, 130\u2013138 (2022).","journal-title":"Radiology"},{"key":"313_CR12","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.222432","volume":"309","author":"PC Douek","year":"2023","unstructured":"Douek, P. C. et al. Clinical applications of photon-counting CT: a review of pioneer studies and a glimpse into the future. Radiology 309, e222432 (2023).","journal-title":"Radiology"},{"key":"313_CR13","doi-asserted-by":"publisher","first-page":"614","DOI":"10.1109\/TNS.2011.2122267","volume":"58","author":"C Xu","year":"2011","unstructured":"Xu, C., Danielsson, M. & Bornefalk, H. Evaluation of energy loss and charge sharing in cadmium telluride detectors for photon-counting computed tomography. IEEE Trans. Nucl. Sci. 58, 614\u2013625 (2011).","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"313_CR14","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1109\/23.940067","volume":"48","author":"T Takahashi","year":"2001","unstructured":"Takahashi, T. et al. High-resolution CdTe detector and applications to imaging devices. IEEE Trans. Nucl. Sci. 48, 287\u2013291 (2001).","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"313_CR15","doi-asserted-by":"publisher","first-page":"783","DOI":"10.1002\/pssb.200304296","volume":"241","author":"C Szeles","year":"2004","unstructured":"Szeles, C. CdZnTe and CdTe materials for X\u2010ray and gamma ray radiation detector applications. Phys. Status Solidi 241, 783\u2013790 (2004).","journal-title":"Phys. Status Solidi"},{"key":"313_CR16","doi-asserted-by":"crossref","unstructured":"Ullberg, C. et al. Measurements of a dual-energy fast photon counting CdTe detector with integrated charge sharing correction. In Medical Imaging 2013: Physics of Medical Imaging. 169\u2013176 (SPIE, 2013).","DOI":"10.1117\/12.2007892"},{"key":"313_CR17","doi-asserted-by":"publisher","first-page":"218","DOI":"10.1016\/j.nima.2014.08.036","volume":"767","author":"MC Veale","year":"2014","unstructured":"Veale, M. C. et al. Measurements of charge sharing in small pixel CdTe detectors. Nucl. Instrum. Meth. Phys. Res. A 767, 218\u2013226 (2014).","journal-title":"Nucl. Instrum. Meth. Phys. Res. A"},{"key":"313_CR18","doi-asserted-by":"publisher","first-page":"C01001","DOI":"10.1088\/1748-0221\/13\/01\/C01001","volume":"13","author":"E Trojanova","year":"2018","unstructured":"Trojanova, E. et al. Evaluation of Timepix3 based CdTe photon counting detector for fully spectroscopic small animal SPECT imaging. JINST 13, C01001 (2018).","journal-title":"JINST"},{"key":"313_CR19","doi-asserted-by":"publisher","first-page":"106409","DOI":"10.1016\/j.radmeas.2020.106409","volume":"137","author":"J Dudak","year":"2020","unstructured":"Dudak, J. High-resolution X-ray imaging applications of hybrid-pixel photon counting detectors Timepix. Radiat. Meas. 137, 106409 (2020).","journal-title":"Radiat. Meas."},{"key":"313_CR20","doi-asserted-by":"publisher","first-page":"3766","DOI":"10.1109\/TMI.2020.3004648","volume":"39","author":"S Procz","year":"2020","unstructured":"Procz, S. et al. Investigation of CdTe, GaAs, Se and Si as sensor materials for mammography. IEEE Trans. Med. Imaging. 39, 3766\u20133778 (2020).","journal-title":"IEEE Trans. Med. Imaging."},{"key":"313_CR21","doi-asserted-by":"publisher","first-page":"P01004","DOI":"10.1088\/1748-0221\/17\/01\/P01004","volume":"17","author":"N Clements","year":"2022","unstructured":"Clements, N., Richtsmeier, D., Hart, A. & Bazalova-Carter, M. Multi-contrast CT imaging using a high energy resolution CdTe detector and a CZT photon-counting detector. JINST 17, P01004 (2022).","journal-title":"JINST"},{"key":"313_CR22","doi-asserted-by":"publisher","first-page":"P11015","DOI":"10.1088\/1748-0221\/16\/11\/P11015","volume":"16","author":"J Nguyen","year":"2021","unstructured":"Nguyen, J., Rodesch, P. A., Richtsmeier, D., Iniewski, K. & Bazalova-Carter, M. Optimization of a CZT photon counting detector for contaminant detection. JINST 16, P11015 (2021).","journal-title":"JINST"},{"key":"313_CR23","doi-asserted-by":"publisher","first-page":"15","DOI":"10.3390\/instruments3010015","volume":"3","author":"F Acerbi","year":"2019","unstructured":"Acerbi, F. et al. Silicon photomultipliers: technology optimizations for ultraviolet, visible and near-infrared range. Instruments 3, 15 (2019).","journal-title":"Instruments"},{"key":"313_CR24","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1016\/S0168-9002(03)00749-6","volume":"504","author":"P Buzhan","year":"2003","unstructured":"Buzhan, P. et al. Silicon photomultiplier and its possible applications. Nucl. Instrum. Meth. Phys. Res. A 504, 48\u201352 (2003).","journal-title":"Nucl. Instrum. Meth. Phys. Res. A"},{"key":"313_CR25","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1109\/JSEN.2015.2483565","volume":"16","author":"D Bronzi","year":"2015","unstructured":"Bronzi, D. et al. SPAD figures of merit for photon-counting, photon-timing, and imaging applications: a review. IEEE Sens. J. 16, 3\u201312 (2015).","journal-title":"IEEE Sens. J."},{"key":"313_CR26","doi-asserted-by":"publisher","first-page":"17TR01","DOI":"10.1088\/1361-6560\/ab7b2d","volume":"65","author":"S Gundacker","year":"2020","unstructured":"Gundacker, S. & Heering, A. The silicon photomultiplier: fundamentals and applications of a modern solid-state photon detector. Phys. Med. Biol. 65, 17TR01 (2020).","journal-title":"Phys. Med. Biol."},{"key":"313_CR27","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1016\/j.nima.2018.11.118","volume":"926","author":"F Acerbi","year":"2019","unstructured":"Acerbi, F. & Gundacker, S. Understanding and simulating SiPMs. Nucl. Instrum. Meth. Phys. Res. A 926, 16\u201335 (2019).","journal-title":"Nucl. Instrum. Meth. Phys. Res. A"},{"key":"313_CR28","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1016\/j.nima.2018.11.018","volume":"936","author":"T Maruhashi","year":"2019","unstructured":"Maruhashi, T. et al. Evaluation of a novel photon-counting CT system using a 16-channel MPPC array for multicolor 3-D imaging. Nucl. Instrum. Meth. Phys. Res. A 936, 5\u20139 (2019).","journal-title":"Nucl. Instrum. Meth. Phys. Res. A"},{"key":"313_CR29","doi-asserted-by":"publisher","DOI":"10.1016\/j.nima.2020.164610","volume":"984","author":"H Kiji","year":"2020","unstructured":"Kiji, H. et al. 64-channel photon-counting computed tomography using a new MPPC-CT system. Nucl. Instrum. Meth. Phys. Res. A 984, 164610 (2020).","journal-title":"Nucl. Instrum. Meth. Phys. Res. A"},{"key":"313_CR30","doi-asserted-by":"publisher","first-page":"368","DOI":"10.1016\/j.nima.2017.12.061","volume":"912","author":"A Koyama","year":"2018","unstructured":"Koyama, A. et al. Fabrication and characterization of a 500-\u03bcm-pitch 64-channel silicon photomultiplier prototype.\u201d. Nucl. Instrum. Meth. Phys. Res. A 912, 368\u2013371 (2018).","journal-title":"Nucl. Instrum. Meth. Phys. Res. A"},{"key":"313_CR31","doi-asserted-by":"publisher","first-page":"6324","DOI":"10.1002\/mp.14886","volume":"48","author":"SJ van der Sar","year":"2021","unstructured":"van der Sar, S. J., Brunner, S. E. & Schaart, D. R. Silicon photomultiplier\u2010based scintillation detectors for photon\u2010counting CT: A feasibility study. Med. Phys. 48, 6324\u20136338 (2021).","journal-title":"Med. Phys."},{"key":"313_CR32","doi-asserted-by":"publisher","first-page":"1404","DOI":"10.1109\/TNS.2023.3271694","volume":"70","author":"N Tuccori","year":"2023","unstructured":"Tuccori, N. & Peeters, S. J. Photon-counting computed tomography and scintillator-based detectors: a simulation analysis with scintillating and reflecting materials currently on the market. IEEE Trans. Nucl. Sci. 70, 1404\u20131412 (2023).","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"313_CR33","doi-asserted-by":"publisher","first-page":"2085","DOI":"10.1016\/j.jcrysgro.2007.12.041","volume":"310","author":"WM Higgins","year":"2008","unstructured":"Higgins, W. M. et al. Crystal growth of large diameter LaBr3:Ce and CeBr3. J. Cryst. Growth 310, 2085\u20132089 (2008).","journal-title":"J. Cryst. Growth"},{"key":"313_CR34","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1016\/j.nima.2007.01.161","volume":"574","author":"F Quarati","year":"2007","unstructured":"Quarati, F. et al. X-ray and gamma-ray response of a 2 \u2033\u00d7 2 \u2033LaBr3:Ce scintillation detector. Nucl. Instrum. Meth. Phys. Res. A 574, 115\u2013120 (2007).","journal-title":"Nucl. Instrum. Meth. Phys. Res. A"},{"key":"313_CR35","doi-asserted-by":"publisher","DOI":"10.1016\/j.nima.2020.164900","volume":"988","author":"M Kaburagi","year":"2021","unstructured":"Kaburagi, M. et al. Gamma-ray spectroscopy with a CeBr3 scintillator under intense \u03b3-ray fields for nuclear decommissioning. Nucl. Instrum. Meth. Phys. Res. A 988, 164900 (2021).","journal-title":"Nucl. Instrum. Meth. Phys. Res. A"},{"key":"313_CR36","doi-asserted-by":"publisher","first-page":"988","DOI":"10.1109\/TNS.2020.2975296","volume":"67","author":"Y Otaka","year":"2020","unstructured":"Otaka, Y. et al. Performance evaluation of liquinert-processed CeBr3 crystals coupled with a multipixel photon counter. IEEE Trans. Nucl. Sci. 67, 988\u2013993 (2020).","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"313_CR37","doi-asserted-by":"publisher","first-page":"085013","DOI":"10.1088\/1361-6560\/ab78bf","volume":"65","author":"J Rossignol","year":"2020","unstructured":"Rossignol, J. et al. Time-of-flight computed tomography-proof of principle. Phys. Med. Biol. 65, 085013 (2020).","journal-title":"Phys. Med. Biol."},{"key":"313_CR38","doi-asserted-by":"publisher","first-page":"055027","DOI":"10.1088\/1361-6560\/ad1f85","volume":"69","author":"J Rossignol","year":"2024","unstructured":"Rossignol, J. et al. Time-of-flight scatter rejection in x-ray radiography. Phys. Med. Biol. 69, 055027 (2024).","journal-title":"Phys. Med. Biol."},{"key":"313_CR39","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/JQE.2018.2802542","volume":"54","author":"F Acerbi","year":"2018","unstructured":"Acerbi, F. et al. High-density silicon photomultipliers: performance and linearity evaluation for high efficiency and dynamic-range applications. IEEE J. Quantum Electron. 54, 1\u20137 (2018).","journal-title":"IEEE J. Quantum Electron."},{"key":"313_CR40","doi-asserted-by":"publisher","DOI":"10.1016\/j.nima.2023.168042","volume":"1049","author":"L Parellada-Monreal","year":"2023","unstructured":"Parellada-Monreal, L. et al. 3D integration technologies for custom SiPM: from BSI to TSV interconnections. Nucl. Instrum. Meth. Phys. Res. A 1049, 168042 (2023).","journal-title":"Nucl. Instrum. Meth. Phys. Res. A"},{"key":"313_CR41","doi-asserted-by":"publisher","first-page":"C02028","DOI":"10.1088\/1748-0221\/12\/02\/C02028","volume":"12","author":"M Yoshino","year":"2017","unstructured":"Yoshino, M. et al. Development and performance evaluation of time-over-threshold based digital PET (TODPET2) scanner using SiPM\/Ce: GAGG-arrays for non-invasive measurement of blood RI concentrations. J. Instrum. 12, C02028 (2017).","journal-title":"J. Instrum."},{"key":"313_CR42","doi-asserted-by":"publisher","first-page":"1942","DOI":"10.1016\/j.optmat.2014.04.001","volume":"36","author":"K Kamada","year":"2014","unstructured":"Kamada, K. et al. Cz grown 2-in. size Ce:Gd3(Al,Ga)5O12 single crystal; relationship between Al, Ga site occupancy and scintillation properties. Opt. Mater. 36, 1942\u20131945 (2014).","journal-title":"Opt. Mater."},{"key":"313_CR43","doi-asserted-by":"publisher","DOI":"10.1016\/j.nima.2020.164464","volume":"979","author":"J Iwanowska-Hanke","year":"2020","unstructured":"Iwanowska-Hanke, J. et al. Cerium-doped gadolinium fine aluminum gallate in scintillation spectrometry. Nucl. Instrum. Meth. Phys. Res. A 979, 164464 (2020).","journal-title":"Nucl. Instrum. Meth. Phys. Res. A"},{"key":"313_CR44","doi-asserted-by":"publisher","DOI":"10.1016\/j.nima.2018.10.177","volume":"954","author":"K Shimazoe","year":"2020","unstructured":"Shimazoe, K. et al. Development of simultaneous PET and Compton imaging using GAGG-SiPM based pixel detectors. Nucl. Instrum. Meth. Phys. Res. A 954, 161499 (2020).","journal-title":"Nucl. Instrum. Meth. Phys. Res. A"},{"key":"313_CR45","doi-asserted-by":"publisher","first-page":"1801","DOI":"10.1109\/TNS.2021.3084144","volume":"68","author":"S Sato","year":"2021","unstructured":"Sato, S., Uenomachi, M. & Shimazoe, K. Development of multichannel high time resolution data acquisition system for TOT-ASIC. IEEE Trans. Nucl. Sci. 68, 1801\u20131806 (2021).","journal-title":"IEEE Trans. Nucl. Sci."},{"key":"313_CR46","doi-asserted-by":"crossref","unstructured":"Roque, R. C., et al. Spatial resolution properties of krypton-based mixtures using a 100 thick gas electron multiplier. J. Instrum. 13, P10010 (2018).","DOI":"10.1088\/1748-0221\/13\/10\/P10010"},{"key":"313_CR47","doi-asserted-by":"crossref","unstructured":"Zhang, S., Wang, F., Wu, X., Gao, K. MTF measurement by slanted-edge method based on improved zernike moments. Sensors 23, 509 (2023).","DOI":"10.3390\/s23010509"},{"key":"313_CR48","doi-asserted-by":"publisher","first-page":"169372","DOI":"10.1016\/j.nima.2024.169372","volume":"1064","author":"M Hamdan","year":"2024","unstructured":"Hamdan, M. et al. The fabrication and characterization of direct conversion flat panel X-ray imager with TlBr film. Nucl. Instrum. Methods Phys. Res. A. 1064, 169372 (2024).","journal-title":"Nucl. Instrum. Methods Phys. Res. A."},{"key":"313_CR49","doi-asserted-by":"crossref","unstructured":"Scharenberg, L. et al. X-ray imaging with gaseous detectors using the VMM3a and the SRS. Nucl. Instrum. Methods Phys. Res. A, 1011, 165576 (2021).","DOI":"10.1016\/j.nima.2021.165576"}],"container-title":["Communications Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s44172-024-00313-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s44172-024-00313-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s44172-024-00313-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,25]],"date-time":"2024-11-25T06:01:43Z","timestamp":1732514503000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s44172-024-00313-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11,25]]},"references-count":49,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["313"],"URL":"https:\/\/doi.org\/10.1038\/s44172-024-00313-1","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-4182321\/v1","asserted-by":"object"}]},"ISSN":["2731-3395"],"issn-type":[{"value":"2731-3395","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,11,25]]},"assertion":[{"value":"17 April 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 October 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 November 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"167"}}