{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T22:44:29Z","timestamp":1785451469024,"version":"3.56.0"},"reference-count":44,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,3,9]],"date-time":"2026-03-09T00:00:00Z","timestamp":1773014400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,4,22]],"date-time":"2026-04-22T00:00:00Z","timestamp":1776816000000},"content-version":"vor","delay-in-days":44,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Commun Eng"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Two major challenges associated with robotic catheterization are, firstly, the provision of controllable degrees of freedom (DoFs) and, secondly, accessing feedback on the shape and pose of the catheter. Miniaturizable active steering can be achieved through magnetic actuation, and Magnetic Resonance Imaging (MRI) provides high definition, radiation-free 3D imaging that can be utilized for shape-sensing. Here, we propose a structurally adaptable Coaxial Sleeve Magnetic Actuator (CoSMA), with deformation energy provided by the background field of the MRI scanner. Our approach combines the magnetic actuation principle of the easy axis of alignment with the mechanical principles of concentric tube designs. This concept allows for a materially flexible (\n                    <jats:inline-formula>\n                      <jats:alternatives>\n                        <jats:tex-math>$$E={{\\mathcal{O}}}(1\\,{{\\rm{MPa}}})$$<\/jats:tex-math>\n                        <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                          <mml:mi>E<\/mml:mi>\n                          <mml:mo>=<\/mml:mo>\n                          <mml:mi>O<\/mml:mi>\n                          <mml:mrow>\n                            <mml:mo>(<\/mml:mo>\n                            <mml:mrow>\n                              <mml:mn>1<\/mml:mn>\n                              <mml:mspace\/>\n                              <mml:mi>MPa<\/mml:mi>\n                            <\/mml:mrow>\n                            <mml:mo>)<\/mml:mo>\n                          <\/mml:mrow>\n                        <\/mml:math>\n                      <\/jats:alternatives>\n                    <\/jats:inline-formula>\n                    ), and therefore risk reduced, multi-DoF catheter. We demonstrate the CoSMA, constructed of three coaxial components with respective outer diameters of 4 mm, 1.5 mm and 0.4 mm, in an aortic arch phantom navigation within the bore of a pre-clinical MRI scanner.\n                  <\/jats:p>","DOI":"10.1038\/s44172-026-00636-1","type":"journal-article","created":{"date-parts":[[2026,3,9]],"date-time":"2026-03-09T05:15:30Z","timestamp":1773033330000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["A concentric tube catheter for endoluminal interventions, steered and imaged via magnetic resonance imaging"],"prefix":"10.1038","volume":"5","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4927-071X","authenticated-orcid":false,"given":"Peter","family":"Lloyd","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nikita","family":"Murasovs","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0002-4143-7201","authenticated-orcid":false,"given":"Yael L.","family":"May","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alistair","family":"Bacchetti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1460-9920","authenticated-orcid":false,"given":"Benjamin","family":"Calm\u00e9","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joshua","family":"Davy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vittorio","family":"Francescon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9232-4966","authenticated-orcid":false,"given":"James H.","family":"Chandler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2165-7154","authenticated-orcid":false,"given":"Erica","family":"Dall\u2019Armellina","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jurgen E.","family":"Schneider","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2280-5438","authenticated-orcid":false,"given":"Pietro","family":"Valdastri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,3,9]]},"reference":[{"key":"636_CR1","doi-asserted-by":"publisher","first-page":"467","DOI":"10.1038\/nature14543","volume":"521","author":"D Rus","year":"2015","unstructured":"Rus, D. & Tolley, M. T. Design, fabrication and control of soft robots. Nature 521, 467\u2013475 (2015).","journal-title":"Nature"},{"key":"636_CR2","doi-asserted-by":"publisher","first-page":"032003","DOI":"10.1088\/2516-1091\/ab9f41","volume":"2","author":"T da Veiga","year":"2020","unstructured":"da Veiga, T. et al. Challenges of continuum robots in clinical context: a review. Prog. Biomed. Eng. 2, 032003 (2020).","journal-title":"Prog. Biomed. Eng."},{"key":"636_CR3","doi-asserted-by":"publisher","first-page":"2300093","DOI":"10.1002\/aisy.202300093","volume":"6","author":"Z Wang","year":"2024","unstructured":"Wang, Z., Klingner, A., Magdanz, V., Misra, S. & Khalil, I. S. Soft bio-microrobots: toward biomedical applications. Adv. Intell. Syst. 6, 2300093 (2024).","journal-title":"Adv. Intell. Syst."},{"key":"636_CR4","doi-asserted-by":"publisher","first-page":"eaax7329","DOI":"10.1126\/scirobotics.aax7329","volume":"4","author":"Y Kim","year":"2019","unstructured":"Kim, Y., Parada, G. A., Liu, S. & Zhao, X. Ferromagnetic soft continuum robots. Sci. Robot. 4, eaax7329 (2019).","journal-title":"Sci. Robot."},{"key":"636_CR5","doi-asserted-by":"crossref","unstructured":"Gilbert, H. B., Rucker, D. C. & Webster III, R. J. Concentric tube robots: the state of the art and future directions. In Robotics Research: The 16th International Symposium ISRR, 253\u2013269 (Springer, 2016).","DOI":"10.1007\/978-3-319-28872-7_15"},{"key":"636_CR6","doi-asserted-by":"crossref","unstructured":"Su, H. et al. A mri-guided concentric tube continuum robot with piezoelectric actuation: a feasibility study. In 2012 IEEE International Conference on Robotics and Automation, 1939\u20131945 (IEEE, 2012).","DOI":"10.1109\/ICRA.2012.6224550"},{"key":"636_CR7","doi-asserted-by":"publisher","first-page":"1263","DOI":"10.1177\/0278364910367543","volume":"29","author":"DC Rucker","year":"2010","unstructured":"Rucker, D. C., Webster III, R. J., Chirikjian, G. S. & Cowan, N. J. Equilibrium conformations of concentric-tube continuum robots. Int. J. Robot. Res. 29, 1263\u20131280 (2010).","journal-title":"Int. J. Robot. Res."},{"key":"636_CR8","unstructured":"Rucker, D. C. & Gilbert, H. B. Methods for improving stability of concentric tube steerable devices using asymmetric flexural rigidity (2024). US Patent 11,964,387."},{"key":"636_CR9","doi-asserted-by":"publisher","first-page":"418","DOI":"10.1177\/02783649211071113","volume":"41","author":"Q Peyron","year":"2022","unstructured":"Peyron, Q. et al. Magnetic concentric tube robots: introduction and analysis. Int. J. Robot. Res. 41, 418\u2013440 (2022).","journal-title":"Int. J. Robot. Res."},{"key":"636_CR10","doi-asserted-by":"publisher","first-page":"6555","DOI":"10.1109\/LRA.2023.3307294","volume":"8","author":"M Richter","year":"2023","unstructured":"Richter, M., Venkiteswaran, V. K. & Misra, S. Concentric tube-inspired magnetic reconfiguration of variable stiffness catheters for needle guidance. IEEE Robot. Autom. Lett. 8, 6555\u20136562 (2023).","journal-title":"IEEE Robot. Autom. Lett."},{"key":"636_CR11","doi-asserted-by":"publisher","first-page":"0188","DOI":"10.34133\/cbsystems.0188","volume":"5","author":"Z Li","year":"2024","unstructured":"Li, Z. & Xu, Q. Multi-section magnetic soft robot with multirobot navigation system for vasculature intervention. Cyborg Bionic Syst. 5, 0188 (2024).","journal-title":"Cyborg Bionic Syst."},{"key":"636_CR12","doi-asserted-by":"publisher","first-page":"172023","DOI":"10.1016\/j.jmmm.2024.172023","volume":"597","author":"H Liu","year":"2024","unstructured":"Liu, H. et al. A concentric tube magnetic continuum robot with multiple stiffness levels and high flexibility for potential endovascular intervention. J. Magn. Magn. Mater. 597, 172023 (2024).","journal-title":"J. Magn. Magn. Mater."},{"key":"636_CR13","doi-asserted-by":"crossref","unstructured":"Pane, S., Zhang, M., Iacovacci, V., Zhang, L. & Menciassi, A. Contrast-enhanced ultrasound tracking of helical propellers with acoustic phase analysis and comparison with color doppler. APL Bioeng. 6, 036102 (2022).","DOI":"10.1063\/5.0097145"},{"key":"636_CR14","doi-asserted-by":"publisher","first-page":"910","DOI":"10.1109\/TMRB.2022.3204577","volume":"4","author":"TL Thomas","year":"2022","unstructured":"Thomas, T. L., Sikorski, J., Ananthasuresh, G., Venkiteswaran, V. K. & Misra, S. Design, sensing, and control of a magnetic compliant continuum manipulator. IEEE Trans. Med. Robot. Bionics 4, 910\u2013921 (2022).","journal-title":"IEEE Trans. Med. Robot. Bionics"},{"key":"636_CR15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s44182-024-00008-x","volume":"2","author":"F Fischer","year":"2024","unstructured":"Fischer, F., Gletter, C., Jeong, M. & Qiu, T. Magneto-oscillatory localization for small-scale robots. npj Robot. 2, 1 (2024).","journal-title":"npj Robot."},{"key":"636_CR16","doi-asserted-by":"publisher","first-page":"763","DOI":"10.1080\/17434440.2022.2141110","volume":"19","author":"BF Kilbride","year":"2022","unstructured":"Kilbride, B. F. et al. Mri-guided endovascular intervention: current methods and future potential. Expert Rev. Med. devices 19, 763\u2013778 (2022).","journal-title":"Expert Rev. Med. devices"},{"key":"636_CR17","doi-asserted-by":"publisher","first-page":"1900110","DOI":"10.1002\/aisy.201900110","volume":"2","author":"O Erin","year":"2020","unstructured":"Erin, O., Boyvat, M., Tiryaki, M. E., Phelan, M. & Sitti, M. Magnetic resonance imaging system\u2013driven medical robotics. Adv. Intell. Syst. 2, 1900110 (2020).","journal-title":"Adv. Intell. Syst."},{"key":"636_CR18","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1007\/s10334-010-0214-y","volume":"23","author":"K Zhang","year":"2010","unstructured":"Zhang, K. et al. Real-time mr navigation and localization of an intravascular catheter with ferromagnetic components. Magn. Reson. Mater. Phys. Biol. Med. 23, 153\u2013163 (2010).","journal-title":"Magn. Reson. Mater. Phys. Biol. Med."},{"key":"636_CR19","doi-asserted-by":"publisher","first-page":"4994","DOI":"10.1118\/1.3622599","volume":"38","author":"FP Gosselin","year":"2011","unstructured":"Gosselin, F. P., Lalande, V. & Martel, S. Characterization of the deflections of a catheter steered using a magnetic resonance imaging system. Med. Phys. 38, 4994\u20135002 (2011).","journal-title":"Med. Phys."},{"key":"636_CR20","doi-asserted-by":"crossref","unstructured":"Tiryaki, M. E., Do\u011fang\u00fcn, F., Dayan, C. B., Wrede, P. & Sitti, M. Mri-powered magnetic miniature capsule robot with hifu-controlled on-demand drug delivery. In Proc. IEEE International Conference on Robotics and Automation, 5420\u20135425 (IEEE, 2023).","DOI":"10.1109\/ICRA48891.2023.10161197"},{"key":"636_CR21","doi-asserted-by":"crossref","unstructured":"Bergeles, C., Vartholomeos, P., Qin, L. & Dupont, P. E. Closed-loop commutation control of an mri-powered robot actuator. In Proc. IEEE International Conference on Robotics and Automation, 698\u2013703 (IEEE, 2013).","DOI":"10.1109\/ICRA.2013.6630649"},{"key":"636_CR22","doi-asserted-by":"crossref","unstructured":"Murasovs, N. et al. Gradient pulling of a tethered robot via a magnetic resonance imaging system. Device 3, 100870 (2025).","DOI":"10.1016\/j.device.2025.100870"},{"key":"636_CR23","doi-asserted-by":"publisher","first-page":"eaax7342","DOI":"10.1126\/scirobotics.aax7342","volume":"4","author":"A Azizi","year":"2019","unstructured":"Azizi, A., Tremblay, C. C., Gagn\u00e9, K. & Martel, S. Using the fringe field of a clinical mri scanner enables robotic navigation of tethered instruments in deeper vascular regions. Sci. Robot. 4, eaax7342 (2019).","journal-title":"Sci. Robot."},{"key":"636_CR24","doi-asserted-by":"crossref","unstructured":"Tuna, E. E. et al. Analysis of dynamic response of an mri-guided magnetically-actuated steerable catheter system. In 2018 IEEE\/RSJ International Conference on Intelligent Robots and Systems (IROS), 1\u20139 (IEEE, 2018).","DOI":"10.1109\/IROS.2018.8594308"},{"key":"636_CR25","unstructured":"Phelan III, M. F.Interventional Lorentz Force-Based Actuation under Magnetic Resonance Imaging. Ph.D. thesis, (Carnegie Mellon University, 2022)."},{"key":"636_CR26","doi-asserted-by":"publisher","first-page":"11895","DOI":"10.1021\/acsami.7b01209","volume":"9","author":"MM Schmauch","year":"2017","unstructured":"Schmauch, M. M., Mishra, S. R., Evans, E. E., Velev, O. D. & Tracy, J. B. Chained iron microparticles for directionally controlled actuation of soft robots. ACS Appl. Mater. interfaces 9, 11895\u201311901 (2017).","journal-title":"ACS Appl. Mater. interfaces"},{"key":"636_CR27","doi-asserted-by":"crossref","unstructured":"Qiu, M. Y. et al. Quantification of the flexural rigidity of endovascular surgical devices using three-point bending tests. Res. Sq 3, 3736325 (2023).","DOI":"10.21203\/rs.3.rs-3736325\/v1"},{"key":"636_CR28","unstructured":"Manda, Y. R. & Baradhi, K. M.Cardiac Catheterization Risks and Complications (StatPearls Publishing, 2025)."},{"key":"636_CR29","first-page":"21","volume":"30","author":"M Sadler","year":"2023","unstructured":"Sadler, M. & Lawson, C. Cardiac catheterisation: avoiding common pitfalls with transradial vascular access. Br. J. Cardiol. 30, 21 (2023).","journal-title":"Br. J. Cardiol."},{"key":"636_CR30","doi-asserted-by":"publisher","first-page":"537","DOI":"10.4244\/EIJ-D-21-00145","volume":"17","author":"R Beyar","year":"2021","unstructured":"Beyar, R. et al. Robotics, imaging, and artificial intelligence in the catheterisation laboratory: cath lab robotics, imaging, and ai. EuroIntervention 17, 537 (2021).","journal-title":"EuroIntervention"},{"key":"636_CR31","doi-asserted-by":"publisher","DOI":"10.1007\/s11886-019-1218-5","volume":"21","author":"ZK Wegermann","year":"2019","unstructured":"Wegermann, Z. K., Swaminathan, R. V. & Rao, S. V. Cath lab robotics: paradigm change in interventional cardiology? Curr. Cardiol. Rep. 21, 119 (2019).","journal-title":"Curr. Cardiol. Rep."},{"key":"636_CR32","doi-asserted-by":"publisher","first-page":"972","DOI":"10.1002\/jmri.25708","volume":"46","author":"PM Jungmann","year":"2017","unstructured":"Jungmann, P. M., Agten, C. A., Pfirrmann, C. W. & Sutter, R. Advances in mri around metal. J. Magn. Reson. Imaging 46, 972\u2013991 (2017).","journal-title":"J. Magn. Reson. Imaging"},{"key":"636_CR33","doi-asserted-by":"publisher","first-page":"209","DOI":"10.1109\/TRO.2009.2035740","volume":"26","author":"PE Dupont","year":"2009","unstructured":"Dupont, P. E., Lock, J., Itkowitz, B. & Butler, E. Design and control of concentric-tube robots. IEEE Trans. Robot. 26, 209\u2013225 (2009).","journal-title":"IEEE Trans. Robot."},{"key":"636_CR34","doi-asserted-by":"crossref","unstructured":"Webster, R. J., Okamura, A. M. & Cowan, N. J. Toward active cannulas: Miniature snake-like surgical robots. In 2006 IEEE\/RSJ international conference on intelligent robots and systems, 2857\u20132863 (IEEE, 2006).","DOI":"10.1109\/IROS.2006.282073"},{"key":"636_CR35","doi-asserted-by":"publisher","first-page":"1247","DOI":"10.1109\/TRO.2007.910775","volume":"23","author":"JJ Abbott","year":"2007","unstructured":"Abbott, J. J., Ergeneman, O., Kummer, M. P., Hirt, A. M. & Nelson, B. J. Modeling magnetic torque and force for controlled manipulation of soft-magnetic bodies. IEEE Trans. Robot. 23, 1247\u20131252 (2007).","journal-title":"IEEE Trans. Robot."},{"key":"636_CR36","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1177\/0278364916683443","volume":"36","author":"J Edelmann","year":"2017","unstructured":"Edelmann, J., Petruska, A. J. & Nelson, B. J. Magnetic control of continuum devices. Int. J. Robot. Res. 36, 68\u201385 (2017).","journal-title":"Int. J. Robot. Res."},{"key":"636_CR37","doi-asserted-by":"publisher","first-page":"907","DOI":"10.1109\/TMECH.2022.3213934","volume":"28","author":"D Lin","year":"2022","unstructured":"Lin, D. et al. Position and orientation control of multisection magnetic soft microcatheters. IEEE\/ASME Trans. Mechatron. 28, 907\u2013918 (2022).","journal-title":"IEEE\/ASME Trans. Mechatron."},{"key":"636_CR38","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1038\/s44172-023-00098-9","volume":"2","author":"G Pittiglio","year":"2023","unstructured":"Pittiglio, G. et al. Personalized magnetic tentacles for targeted photothermal cancer therapy in peripheral lungs. Commun. Eng. 2, 50 (2023).","journal-title":"Commun. Eng."},{"key":"636_CR39","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1146\/annurev-control-081219-082713","volume":"3","author":"JJ Abbott","year":"2020","unstructured":"Abbott, J. J., Diller, E. & Petruska, A. J. Magnetic methods in robotics. Annu. Rev. Control Robot. Autonom. Syst. 3, 57\u201390 (2020).","journal-title":"Annu. Rev. Control Robot. Autonom. Syst."},{"key":"636_CR40","doi-asserted-by":"publisher","first-page":"1309","DOI":"10.1039\/C5NR07410J","volume":"8","author":"SR Mishra","year":"2016","unstructured":"Mishra, S. R., Dickey, M. D., Velev, O. D. & Tracy, J. B. Selective and directional actuation of elastomer films using chained magnetic nanoparticles. Nanoscale 8, 1309\u20131313 (2016).","journal-title":"Nanoscale"},{"key":"636_CR41","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1109\/TRO.2008.2006868","volume":"25","author":"RJ Webster","year":"2008","unstructured":"Webster, R. J., Romano, J. M. & Cowan, N. J. Mechanics of precurved-tube continuum robots. IEEE Trans. Robot. 25, 67\u201378 (2008).","journal-title":"IEEE Trans. Robot."},{"key":"636_CR42","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1109\/TRO.2014.2378431","volume":"31","author":"C Bergeles","year":"2015","unstructured":"Bergeles, C. et al. Concentric tube robot design and optimization based on task and anatomical constraints. IEEE Trans. Robot. 31, 67\u201384 (2015).","journal-title":"IEEE Trans. Robot."},{"key":"636_CR43","unstructured":"Bozorth, R. M.Technical and Pure Iron, 48\u201366 (IEEE, 1978)."},{"key":"636_CR44","doi-asserted-by":"crossref","unstructured":"Lloyd, P., Pittiglio, G., Chandler, J. H. & Valdastri, P. Optimal design of soft continuum magnetic robots under follow-the-leader shape forming actuation. In 2020 International Symposium on Medical Robotics (ISMR), 111\u2013117 (IEEE, 2020).","DOI":"10.1109\/ISMR48331.2020.9312943"}],"container-title":["Communications Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s44172-026-00636-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s44172-026-00636-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s44172-026-00636-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,21]],"date-time":"2026-04-21T22:40:24Z","timestamp":1776811224000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s44172-026-00636-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,9]]},"references-count":44,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["636"],"URL":"https:\/\/doi.org\/10.1038\/s44172-026-00636-1","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-7629088\/v1","asserted-by":"object"}]},"ISSN":["2731-3395"],"issn-type":[{"value":"2731-3395","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,9]]},"assertion":[{"value":"21 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 February 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 March 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"74"}}