{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T09:20:20Z","timestamp":1788254420274,"version":"build-2803163510"},"reference-count":49,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T00:00:00Z","timestamp":1788220800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Commun Eng"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Intracortical brain-computer interfaces (iBCIs) hold promise for restoring motor, sensory, and cognitive functions, including applications in paralysis treatment and speech decoding. High-density microelectrode arrays (MEAs) provide fine spatial and temporal discrimination of neural activity, but the considerable upsurge in data generation poses challenges for wireless transmission from miniaturized implants due to constraints on power, bandwidth, heat dissipation, and device size. To address these constraints, we propose a two-stage wireless iBCI architecture comprising a transdural galvanic-coupled body channel communication (BCC) link from a free-floating MEA to an intracranial unit, followed by a transcutaneous link to an external unit. This study focuses on the transdural BCC telemetry system, which provides compact, wideband, and energy-efficient data transmission. Phantom tests, and ex vivo experiments using a human cadaveric head specimen validate the system, demonstrating wireless transmission up to 500 Mbps with 20% duty cycling and bit error rates below 10\u207b\u2075. The system incorporates the send-on-delta encoder (SODA), achieving up to 11.4\u00d7 data compression and reducing thermal load for meeting the safety guidelines. Safety is further examined using brain-on-a-chip models, which demonstrate that the system does not evoke unintended neural activity, supporting the platform\u2019s long-term viability for high-resolution iBCIs.<\/jats:p>","DOI":"10.1038\/s44172-026-00735-z","type":"journal-article","created":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T09:02:40Z","timestamp":1788253360000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["An Event based Body Coupled Transdural Telemetry for Intracortical Brain Computer Interfaces"],"prefix":"10.1038","volume":"5","author":[{"given":"Chengyao","family":"Shi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laura","family":"Nuttin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4979-2366","authenticated-orcid":false,"given":"Zhenyu","family":"Gao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7812-1916","authenticated-orcid":false,"given":"Yuming","family":"He","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0004-2070-6809","authenticated-orcid":false,"given":"Pietro","family":"Russo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0003-4721-3556","authenticated-orcid":false,"given":"Hua-Peng","family":"Liaw","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marios","family":"Gourdouparis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2373-2795","authenticated-orcid":false,"given":"Dennis","family":"Lambrechts","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7744-5054","authenticated-orcid":false,"given":"Guido","family":"Dolmans","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yao-Hong","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,1]]},"reference":[{"key":"735_CR1","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1038\/s41591-024-03341-8","volume":"31","author":"MS Willsey","year":"2025","unstructured":"Willsey, M. S. et al. A high-performance brain\u2013computer interface for finger decoding and quadcopter game control in an individual with paralysis. Nat. Med. 31, 96\u2013104 (2025).","journal-title":"Nat. Med."},{"key":"735_CR2","doi-asserted-by":"publisher","first-page":"1031","DOI":"10.1038\/s41586-023-06377-x","volume":"620","author":"FR Willett","year":"2023","unstructured":"Willett, F. R. et al. A high-performance speech neuroprosthesis. Nature 620, 1031\u20131036 (2023).","journal-title":"Nature"},{"key":"735_CR3","doi-asserted-by":"publisher","first-page":"232","DOI":"10.1038\/nature24636","volume":"551","author":"J Jun","year":"2017","unstructured":"Jun, J. et al. Fully integrated silicon probes for high-density recording of neural activity. Nature 551, 232\u2013236 (2017).","journal-title":"Nature"},{"key":"735_CR4","doi-asserted-by":"publisher","first-page":"eabf4588","DOI":"10.1126\/science.abf4588","volume":"372","author":"NA Steinmetz","year":"2021","unstructured":"Steinmetz, N. A. et al. Neuropixels 2.0: A miniaturized high-density probe for stable, long-term brain recordings. Science 372, eabf4588 (2021).","journal-title":"Science"},{"key":"735_CR5","doi-asserted-by":"crossref","unstructured":"Yoon, D.-Y. et al. A 1024-channel simultaneous recording neural SoC with stimulation and real-time spike detection. 2021 Symp. VLSI Circuits, 1\u20132 (2021).","DOI":"10.23919\/VLSICircuits52068.2021.9492480"},{"key":"735_CR6","doi-asserted-by":"publisher","first-page":"424","DOI":"10.1038\/s41551-023-01021-5","volume":"7","author":"K Shen","year":"2023","unstructured":"Shen, K. et al. Translational opportunities and challenges of invasive electrodes for neural interfaces. Nat. Biomed. Eng 7, 424\u2013442 (2023).","journal-title":"Nat. Biomed. Eng"},{"key":"735_CR7","doi-asserted-by":"crossref","unstructured":"Schantz, J. T. et al. Cranioplasty after trephination using a novel biodegradable burr hole cover: technical case report. Neurosurgery (2006).","DOI":"10.1227\/01.NEU.0000193533.54580.3F"},{"key":"735_CR8","unstructured":"Wolf, P. D. Thermal Considerations for the Design of an Implanted Cortical Brain\u2013Machine Interface (BMI) In: Reichert WM, editor. Indwelling Neural Implants: Strategies for Contending with the In Vivo Environment. Boca Raton (FL): CRC Press\/Taylor & Francis 3 (2008)."},{"key":"735_CR9","doi-asserted-by":"crossref","unstructured":"Sheppard, J. P., Raposo, D., Churchland, A. K. Dynamic weighting of multisensory stimuli shapes decision-making in rats and humans. J. Vis. (2013).","DOI":"10.1167\/13.6.4"},{"key":"735_CR10","doi-asserted-by":"publisher","first-page":"746","DOI":"10.1038\/264746a0","volume":"264","author":"H MCGURK","year":"1976","unstructured":"MCGURK, H. & MACDONALD, J. Hearing lips and seeing voices. Nature 264, 746\u2013748 (1976).","journal-title":"Nature"},{"key":"735_CR11","doi-asserted-by":"crossref","unstructured":"Chen, X. et al Chronic stability of a neuroprosthesis comprising multiple adjacent Utah arrays in monkeys. J. Neural Eng. (2023)","DOI":"10.1088\/1741-2552\/ace07e"},{"key":"735_CR12","doi-asserted-by":"crossref","unstructured":"Song, M. et al. A 1.66\u2009Gb\/s and 5.8 pJ\/b transcutaneous IR-UWB telemetry system with hybrid impulse modulation for intracortical brain\u2013computer interfaces. 2022 IEEE Int. Solid-State Circuits Conf. (ISSCC), 394\u2013396 (2022).","DOI":"10.1109\/ISSCC42614.2022.9731608"},{"key":"735_CR13","doi-asserted-by":"publisher","first-page":"8061","DOI":"10.1016\/j.biomaterials.2013.07.016","volume":"34","author":"L Karumbaiah","year":"2013","unstructured":"Karumbaiah, L. et al. Relationship between intracortical electrode design and chronic recording function. Biomaterials 34, 8061\u20138074 (2013).","journal-title":"Biomaterials"},{"key":"735_CR14","doi-asserted-by":"publisher","first-page":"3017","DOI":"10.1109\/JSSC.2019.2936303","volume":"54","author":"MM Ghanbari","year":"2019","unstructured":"Ghanbari, M. M. et al. A Sub-mm3 Ultrasonic Free-Floating Implant for Multi-Mote Neural Recording. IEEE J. Solid-State Circuits 54, 3017\u20133030 (2019).","journal-title":"IEEE J. Solid-State Circuits"},{"key":"735_CR15","doi-asserted-by":"publisher","first-page":"13837","DOI":"10.1109\/JSEN.2021.3068077","volume":"21","author":"P Yeon","year":"2021","unstructured":"Yeon, P. et al. Microfabrication, coil characterization, and hermetic packaging of millimeter-sized free-floating neural probes. IEEE Sens. J. 21, 13837\u201313848 (2021).","journal-title":"IEEE Sens. J."},{"key":"735_CR16","doi-asserted-by":"publisher","first-page":"1747","DOI":"10.1109\/TBCAS.2019.2940827","volume":"13","author":"M Li","year":"2019","unstructured":"Li, M. et al. Comparable investigation of characteristics for implant intra-body communication based on galvanic and capacitive coupling. IEEE Trans. Biomed. Circuits Syst. 13, 1747\u20131758 (2019).","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"735_CR17","first-page":"2793","volume":"52","author":"H Kassiri","year":"2017","unstructured":"Kassiri, H. et al. Rail-to-rail-input dual-radio 64-channel closed-loop neurostimulator. IEEE J. Solid-State Circuits 52, 2793\u20132810 (2017).","journal-title":"IEEE J. Solid-State Circuits"},{"key":"735_CR18","doi-asserted-by":"crossref","unstructured":"Wang, M. L. et al. Wireless data links for next-generation networked micro-implantables. 2018 IEEE Custom Integr. Circuits Conf. (CICC), 1\u20139 (2018).","DOI":"10.1109\/CICC.2018.8357096"},{"key":"735_CR19","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1109\/TBCAS.2018.2889802","volume":"13","author":"W Li","year":"2019","unstructured":"Li, W. et al. A 200-Mb\/s energy efficient transcranial transmitter using inductive coupling. IEEE Trans. Biomed. Circuits Syst. 13, 435\u2013443 (2019).","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"735_CR20","doi-asserted-by":"publisher","first-page":"1366","DOI":"10.1109\/TBCAS.2017.2775638","volume":"11","author":"P Yeon","year":"2017","unstructured":"Yeon, P. et al. Feasibility study on active back telemetry and power transmission through an inductive link for millimeter-sized biomedical implants. IEEE Trans. Biomed. Circuits Syst. 11, 1366\u20131376 (2017).","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"735_CR21","doi-asserted-by":"publisher","first-page":"216","DOI":"10.1109\/JERM.2019.2898347","volume":"3","author":"T-C Yu","year":"2019","unstructured":"Yu, T.-C. et al. Design of dual frequency mixed coupling coils of wireless power and data transfer to enhance lateral and angular misalignment tolerance. IEEE J. Electromagn. RF Microw. Med. Biol. 3, 216\u2013223 (2019).","journal-title":"IEEE J. Electromagn. RF Microw. Med. Biol."},{"key":"735_CR22","first-page":"441","volume":"14","author":"A De Marcellis","year":"2020","unstructured":"De Marcellis, A. et al. A 300 Mbps 37 pJ\/bit pulsed optical biotelemetry. IEEE Trans. Biomed. Circuits Syst. 14, 441\u2013451 (2020).","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"735_CR23","doi-asserted-by":"publisher","first-page":"1014","DOI":"10.1109\/TBCAS.2024.3373172","volume":"18","author":"C Shi","year":"2024","unstructured":"Shi, C. et al. A spatially diverse 2TX-3RX galvanic-coupled transdural telemetry for tether-less distributed brain\u2013computer interfaces. IEEE Trans. Biomed. Circuits Syst. 18, 1014\u20131023 (2024).","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"735_CR24","doi-asserted-by":"crossref","unstructured":"Akhoundi, A. et al. 15.2\u2009A 1024-channel 0.00029\u2009mm\u00b2\/ch 74 nW\/ch online spatial spike-sorting chip with event-driven spike detection and self-organizing map clustering. 2025 IEEE Int. Solid-State Circuits Conf. (ISSCC), 268\u2013270 (2025).","DOI":"10.1109\/ISSCC49661.2025.10904780"},{"key":"735_CR25","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1109\/TBCAS.2013.2255874","volume":"7","author":"M Yin","year":"2013","unstructured":"Yin, M. et al. A 100-channel hermetically sealed implantable device for chronic wireless neurosensing applications. IEEE Trans. Biomed. Circuits Syst. 7, 115\u2013128 (2013).","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"735_CR26","doi-asserted-by":"publisher","first-page":"604","DOI":"10.1038\/s41928-021-00631-8","volume":"4","author":"J Lee","year":"2021","unstructured":"Lee, J. et al. Neural recording and stimulation using wireless networks of microimplants. Nat Electron 4, 604\u2013614 (2021).","journal-title":"Nat Electron"},{"key":"735_CR27","doi-asserted-by":"publisher","first-page":"1100","DOI":"10.1109\/TBCAS.2024.3378973","volume":"18","author":"Y He","year":"2024","unstructured":"He, Y. et al. An event-based neural compressive telemetry with >11\u00d7 loss-less data reduction for high-bandwidth intracortical brain\u2013computer interfaces. IEEE Trans. Biomed. Circuits Syst. 18, 1100\u20131111 (2024).","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"735_CR28","doi-asserted-by":"crossref","unstructured":"ICNIRP. Guidelines for limiting exposure to electromagnetic fields (100\u2009kHz to 300\u2009GHz). Health Phys. 118, 000\u2013000 (2020).","DOI":"10.1097\/HP.0000000000001210"},{"key":"735_CR29","doi-asserted-by":"crossref","unstructured":"Gourdouparis, M. et al. 6.2 An ultrasound-powering TX with a global charge-redistribution adiabatic drive achieving 69% power reduction and 53\u00b0 maximum beam steering angle for implantable applications. 2024 IEEE Int. Solid-State Circuits Conf. (ISSCC), 102\u2013104 (2024).","DOI":"10.1109\/ISSCC49657.2024.10454411"},{"key":"735_CR30","doi-asserted-by":"crossref","unstructured":"Gourdouparis M. et al. An ultrasound-powering TX with standing-wave peak tracking employing adiabatic power sensing achieving 82% power-tracking accuracy and <90\u2009ms settling time for brain implants, accepted to be published in IEEE Int. Solid-State Circuits Conf. (ISSCC) 2026.","DOI":"10.1109\/ISSCC49663.2026.11409335"},{"key":"735_CR31","doi-asserted-by":"publisher","first-page":"1252","DOI":"10.1038\/s41551-023-01029-x","volume":"7","author":"W Ouyang","year":"2023","unstructured":"Ouyang, W. et al. A wireless and battery-less implant for multimodal closed-loop neuromodulation in small animals. Nat. Biomed. Eng 7, 1252\u20131269 (2023).","journal-title":"Nat. Biomed. Eng"},{"key":"735_CR32","doi-asserted-by":"publisher","first-page":"e25411","DOI":"10.1371\/journal.pone.0025411","volume":"6","author":"E Delivopoulos","year":"2011","unstructured":"Delivopoulos, E. & Murray, A. F. Controlled adhesion and growth of long-term glial and neuronal cultures on Parylene-C. PLoS ONE 6, e25411 (2011).","journal-title":"PLoS ONE"},{"key":"735_CR33","doi-asserted-by":"publisher","first-page":"e0218850","DOI":"10.1371\/journal.pone.0218850","volume":"14","author":"BJ Raos","year":"2019","unstructured":"Raos, B. J., Simpson, M. C., Doyle, C. S., Graham, E. S. & Unsworth, C. P. Evaluation of parylene derivatives for use as biomaterials for human astrocyte cell patterning. PLoS ONE 14, e0218850 (2019).","journal-title":"PLoS ONE"},{"key":"735_CR34","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1109\/TBME.2008.2002155","volume":"56","author":"J-M Hsu","year":"2009","unstructured":"Hsu, J.-M., Rieth, L., Normann, R. A., Tathireddy, P. & Solzbacher, F. Encapsulation of an integrated neural interface device with Parylene C. IEEE Trans. Biomed. Eng. 56, 23\u201329 (2009).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"735_CR35","doi-asserted-by":"publisher","first-page":"2946","DOI":"10.1109\/JSSC.2007.908693","volume":"42","author":"M Ortmanns","year":"2007","unstructured":"Ortmanns, M., Rocke, A., Gehrke, M. & Tiedtke, H.-J. A 232-channel epiretinal stimulator ASIC. IEEE J. Solid-State Circuits 42, 2946\u20132959 (2007).","journal-title":"IEEE J. Solid-State Circuits"},{"key":"735_CR36","doi-asserted-by":"crossref","unstructured":"Lee, K. H., Duffy, P. S. & Bieber, A. J. (eds) Deep Brain Stimulation: Indications and Applications, 1st edn (Jenny Stanford Publishing, 2016).","DOI":"10.1201\/9781315364759"},{"key":"735_CR37","doi-asserted-by":"publisher","first-page":"2203","DOI":"10.1109\/JSSC.2013.2266862","volume":"48","author":"H-M Lee","year":"2013","unstructured":"Lee, H.-M., Park, H. & Ghovanloo, M. A power-efficient wireless system with adaptive supply control for deep brain stimulation. IEEE J. Solid-State Circuits 48, 2203\u20132216 (2013).","journal-title":"IEEE J. Solid-State Circuits"},{"key":"735_CR38","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1109\/JSSC.2011.2164667","volume":"47","author":"E Noorsal","year":"2012","unstructured":"Noorsal, E. et al. A neural stimulator frontend with high-voltage compliance and programmable pulse shape for epiretinal implants. IEEE J. Solid-State Circuits 47, 244\u2013256 (2012).","journal-title":"IEEE J. Solid-State Circuits"},{"key":"735_CR39","doi-asserted-by":"crossref","unstructured":"Ortmanns, M., Unger, N., Rocke, A., Gehrke, M. & Tietdke, H. J. A 0.1\u2009mm\u00b2, digitally programmable nerve stimulation pad cell with high-voltage capability for a retinal implant. 2006 IEEE Int. Solid-State Circuits Conf. Dig. Tech. Papers, 89\u201398 (2006).","DOI":"10.1109\/ISSCC.2006.1696037"},{"key":"735_CR40","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1109\/TBCAS.2014.2363736","volume":"10","author":"MN van Dongen","year":"2016","unstructured":"van Dongen, M. N. & Serdijn, W. A. A power-efficient multichannel neural stimulator using high-frequency pulsed excitation from an unfiltered dynamic supply. IEEE Trans. Biomed. Circuits Syst. 10, 61\u201371 (2016).","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"735_CR41","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1109\/TBCAS.2010.2040277","volume":"4","author":"K Sooksood","year":"2010","unstructured":"Sooksood, K., Stieglitz, T. & Ortmanns, M. An active approach for charge balancing in functional electrical stimulation. IEEE Trans. Biomed. Circuits Syst. 4, 162\u2013170 (2010).","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"735_CR42","doi-asserted-by":"publisher","first-page":"136449","DOI":"10.1109\/ACCESS.2020.3012028","volume":"8","author":"J-Y Son","year":"2020","unstructured":"Son, J.-Y. & Cha, H.-K. An implantable neural stimulator IC with anodic current pulse modulation based active charge balancing. IEEE Access 8, 136449\u2013136458 (2020).","journal-title":"IEEE Access"},{"key":"735_CR43","doi-asserted-by":"crossref","unstructured":"Ranjandish, R. & Schmid, A. An active charge balancing method based on anodic current variation monitoring. 2017 IEEE Biomed. Circuits Syst. Conf. (BioCAS), 1\u20134 (2017).","DOI":"10.1109\/BIOCAS.2017.8325209"},{"key":"735_CR44","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1109\/TBCAS.2015.2409797","volume":"10","author":"KN Hageman","year":"2016","unstructured":"Hageman, K. N. et al. A CMOS neural interface for a multichannel vestibular prosthesis. IEEE Trans. Biomed. Circuits Syst. 10, 269\u2013279 (2016).","journal-title":"IEEE Trans. Biomed. Circuits Syst."},{"key":"735_CR45","doi-asserted-by":"crossref","unstructured":"Cogan, S. F., Ludwig, K. A., Welle, C. G., & Takmakov, P. Tissue damage thresholds during therapeutic electrical stimulation. Journal of neural engineering, (2016)","DOI":"10.1088\/1741-2560\/13\/2\/021001"},{"key":"735_CR46","doi-asserted-by":"crossref","unstructured":"H. K. O. Berge and P. Hafliger, \u201cHigh-Speed Serial AER on FPGA,\u201d 2007 IEEE International Symposium on Circuits and Systems (ISCAS).","DOI":"10.1109\/ISCAS.2007.378041"},{"key":"735_CR47","doi-asserted-by":"publisher","unstructured":"Steinmetz, Nicholas A.; Carandini, Matteo; Harris, Kenneth (2024). Recording with a Neuropixels probe. University College London. Dataset. https:\/\/doi.org\/10.5522\/04\/25232962.v1","DOI":"10.5522\/04\/25232962.v1"},{"key":"735_CR48","doi-asserted-by":"publisher","first-page":"513","DOI":"10.1016\/j.brs.2021.03.008","volume":"14","author":"C Neudorfer","year":"2021","unstructured":"Neudorfer, C. et al. Kilohertz-frequency stimulation of the nervous system: a review of underlying mechanisms. Brain Stimul. 14, 513\u2013530 (2021).","journal-title":"Brain Stimul."},{"key":"735_CR49","unstructured":"Lonza Bioscience. https:\/\/bioscience.lonza.com\/"}],"container-title":["Communications Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s44172-026-00735-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s44172-026-00735-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s44172-026-00735-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T09:02:45Z","timestamp":1788253365000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s44172-026-00735-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,1]]},"references-count":49,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["735"],"URL":"https:\/\/doi.org\/10.1038\/s44172-026-00735-z","relation":{},"ISSN":["2731-3395"],"issn-type":[{"value":"2731-3395","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,1]]},"assertion":[{"value":"2 December 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 July 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 September 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"All procedures performed in studies involving human anatomical specimens were ethically regulated by the institutional and\/or national research committee, Medisch Ethische Toetsings Commissie (METC). All the human anatomical specimens used for our experiments were donated for scientific research and medical training at the Anatomy Department of the Erasmus Medical Center as part of a national body donation program approved by Dutch law and regulations. Donor made him or herself available to science is registered in the nation donor concil.","order":1,"name":"Ethics","label":"Compliance with ethical standards","group":{"name":"EthicsHeading","label":"Ethics"}},{"value":"The authors declare not competing interests.","order":2,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Ethics"}}],"article-number":"140"}}