{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T05:05:48Z","timestamp":1780635948570,"version":"3.54.1"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,5,20]],"date-time":"2026-05-20T00:00:00Z","timestamp":1779235200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T00:00:00Z","timestamp":1780617600000},"content-version":"vor","delay-in-days":16,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/100000968","name":"American Heart Association","doi-asserted-by":"crossref","award":["postdoctoral fellowship"],"award-info":[{"award-number":["postdoctoral fellowship"]}],"id":[{"id":"10.13039\/100000968","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/100000968","name":"American Heart Association","doi-asserted-by":"crossref","award":["One Brave Idea Award"],"award-info":[{"award-number":["One Brave Idea Award"]}],"id":[{"id":"10.13039\/100000968","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/100000968","name":"American Heart Association","doi-asserted-by":"crossref","award":["AHA's Second Century Early Faculty Independence Award"],"award-info":[{"award-number":["AHA's Second Century Early Faculty Independence Award"]}],"id":[{"id":"10.13039\/100000968","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["npj Cardiovasc Health"],"DOI":"10.1038\/s44325-026-00134-5","type":"journal-article","created":{"date-parts":[[2026,5,20]],"date-time":"2026-05-20T11:37:26Z","timestamp":1779277046000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Optimizing single-lead ECG axis for AI-based detection of myocardial diseases"],"prefix":"10.1038","volume":"3","author":[{"given":"Masamitsu","family":"Nakayama","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryuichiro","family":"Yagi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kyohei","family":"Daigo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshinori","family":"Katsumata","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rahul C.","family":"Deo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Calum A.","family":"MacRae","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shinichi","family":"Goto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,5,20]]},"reference":[{"key":"134_CR1","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1016\/j.jacc.2024.05.003","volume":"84","author":"R Khera","year":"2024","unstructured":"Khera, R. et al. Transforming cardiovascular care with artificial intelligence: from discovery to practice JACC state-of-the-art review. J. Am. Coll. Cardiol. 84, 97\u2013114 (2024).","journal-title":"J. Am. Coll. Cardiol."},{"key":"134_CR2","doi-asserted-by":"publisher","first-page":"346","DOI":"10.1056\/NEJMra2301903","volume":"390","author":"ES Spatz","year":"2024","unstructured":"Spatz, E. S., Ginsburg, G. S., Rumsfeld, J. S. & Turakhia, M. P. Wearable digital health technologies for monitoring in cardiovascular medicine. N. Engl. J. Med. 390, 346\u2013356 (2024).","journal-title":"N. Engl. J. Med."},{"key":"134_CR3","doi-asserted-by":"publisher","first-page":"2381","DOI":"10.1016\/j.jacc.2018.03.003","volume":"71","author":"JM Bumgarner","year":"2018","unstructured":"Bumgarner, J. M. et al. Smartwatch algorithm for automated detection of atrial fibrillation. J. Am. Coll. Cardiol. 71, 2381\u20132388 (2018).","journal-title":"J. Am. Coll. Cardiol."},{"key":"134_CR4","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1001\/jamacardio.2018.0136","volume":"3","author":"GH Tison","year":"2018","unstructured":"Tison, G. H. et al. Passive Detection of Atrial Fibrillation Using a Commercially Available Smartwatch. JAMA Cardiol 3, 409 (2018).","journal-title":"JAMA Cardiol"},{"key":"134_CR5","doi-asserted-by":"publisher","first-page":"2497","DOI":"10.1038\/s41591-022-02053-1","volume":"28","author":"ZI Attia","year":"2022","unstructured":"Attia, Z. I. et al. Prospective evaluation of smartwatch-enabled detection of left ventricular dysfunction. Nat. Med. 28, 2497\u20132503 (2022).","journal-title":"Nat. Med."},{"key":"134_CR6","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1038\/s41746-023-00869-w","volume":"6","author":"A Khunte","year":"2023","unstructured":"Khunte, A. et al. Detection of left ventricular systolic dysfunction from single-lead electrocardiography adapted for portable and wearable devices. npj Digit. Med. 6, 124 (2023).","journal-title":"npj Digit. Med."},{"key":"134_CR7","doi-asserted-by":"publisher","first-page":"554","DOI":"10.1093\/ehjdh\/ztaf034","volume":"6","author":"A Aminorroaya","year":"2025","unstructured":"Aminorroaya, A. et al. Development and multinational validation of an ensemble deep learning algorithm for detecting and predicting structural heart disease using noisy single-lead electrocardiograms. Eur. Heart J. Digit. Health 6, 554\u2013566 (2025).","journal-title":"Eur. Heart J. Digit. Health"},{"key":"134_CR8","doi-asserted-by":"publisher","first-page":"286","DOI":"10.1016\/j.jelectrocard.2023.07.002","volume":"81","author":"KC Siontis","year":"2023","unstructured":"Siontis, K. C. et al. Saliency maps provide insights into artificial intelligence-based electrocardiography models for detecting hypertrophic cardiomyopathy. J. Electrocardiol. 81, 286\u2013291 (2023).","journal-title":"J. Electrocardiol."},{"key":"134_CR9","doi-asserted-by":"publisher","first-page":"101211","DOI":"10.1016\/j.ijcha.2023.101211","volume":"46","author":"N Hirota","year":"2023","unstructured":"Hirota, N. et al. Identification of patients with dilated phase of hypertrophic cardiomyopathy using a convolutional neural network applied to multiple, dual, and single lead electrocardiograms. IJC Heart Vasc. 46, 101211 (2023).","journal-title":"IJC Heart Vasc."},{"key":"134_CR10","doi-asserted-by":"publisher","first-page":"2768","DOI":"10.1016\/j.mayocp.2021.04.023","volume":"96","author":"M Grogan","year":"2021","unstructured":"Grogan, M. et al. Artificial intelligence-enhanced electrocardiogram for the early detection of cardiac amyloidosis. Mayo Clin. Proc. 96, 2768\u20132778 (2021).","journal-title":"Mayo Clin. Proc."},{"key":"134_CR11","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1016\/j.cvdhj.2023.03.001","volume":"4","author":"JS Haimovich","year":"2023","unstructured":"Haimovich, J. S. et al. Artificial intelligence-enabled classification of hypertrophic heart diseases using electrocardiograms. Cardiovasc. Digit. Health J. 4, 48\u201359 (2023).","journal-title":"Cardiovasc. Digit. Health J."},{"key":"134_CR12","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-81374-6","volume":"11","author":"Y-A Chiou","year":"2021","unstructured":"Chiou, Y.-A. et al. Electrocardiogram lead selection for intelligent screening of patients with systolic heart failure. Sci. Rep. 11, 1948 (2021).","journal-title":"Sci. Rep."},{"key":"134_CR13","doi-asserted-by":"publisher","first-page":"1069","DOI":"10.3390\/bioengineering11111069","volume":"11","author":"H Makimoto","year":"2024","unstructured":"Makimoto, H. et al. Identifying ventricular dysfunction indicators in electrocardiograms via artificial intelligence-driven analysis. Bioengineering 11, 1069 (2024).","journal-title":"Bioengineering"},{"key":"134_CR14","doi-asserted-by":"crossref","unstructured":"Nakayama, M., Yagi, R., Deo, R. C., Macrae, C. A. & Goto, S. Identifying optimal electrocardiogram lead combinations for artificial intelligence. Eur. Heart J. 46, ehaf784-4392 (2025).","DOI":"10.1093\/eurheartj\/ehaf784.4392"},{"key":"134_CR15","doi-asserted-by":"publisher","first-page":"562","DOI":"10.1161\/01.CIR.0000117293.30403.8F","volume":"109","author":"HJJ Wellens","year":"2004","unstructured":"Wellens, H. J. J. & Gorgels, A. P. The electrocardiogram 102 years after Einthoven. Circulation 109, 562\u2013564 (2004).","journal-title":"Circulation"},{"key":"134_CR16","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1093\/ehjdh\/ztac065","volume":"3","author":"R Yagi","year":"2022","unstructured":"Yagi, R., Goto, S., Katsumata, Y., MacRae, C. A. & Deo, R. C. Importance of external validation and subgroup analysis of artificial intelligence in the detection of low ejection fraction from electrocardiograms. Eur. Heart J. Digit. Health 3, 654\u2013657 (2022).","journal-title":"Eur. Heart J. Digit. Health"},{"key":"134_CR17","doi-asserted-by":"publisher","first-page":"755","DOI":"10.1161\/CIRCULATIONAHA.121.058696","volume":"146","author":"S Goto","year":"2022","unstructured":"Goto, S. et al. Multinational federated learning approach to train ECG and echocardiogram models for hypertrophic cardiomyopathy detection. Circulation 146, 755\u2013769 (2022).","journal-title":"Circulation"},{"key":"134_CR18","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-021-22877-8","volume":"12","author":"S Goto","year":"2021","unstructured":"Goto, S. et al. Artificial intelligence-enabled fully automated detection of cardiac amyloidosis using electrocardiograms and echocardiograms. Nat. Commun. 12, 2726 (2021).","journal-title":"Nat. Commun."},{"key":"134_CR19","doi-asserted-by":"publisher","first-page":"378","DOI":"10.1016\/S0002-8703(42)90821-4","volume":"24","author":"E Goldberger","year":"1942","unstructured":"Goldberger, E. The aVl, aVr, and aVf leads a simplification of standard lead electrocardiography. Am. Heart J. 24, 378\u2013396 (1942).","journal-title":"Am. Heart J."},{"key":"134_CR20","doi-asserted-by":"publisher","first-page":"574","DOI":"10.1001\/jamacardio.2025.0492","volume":"10","author":"LS Dhingra","year":"2025","unstructured":"Dhingra, L. S. et al. Artificial intelligence-enabled prediction of heart failure risk from single-lead electrocardiograms. JAMA Cardiol 10, 574\u2013584 (2025).","journal-title":"JAMA Cardiol"},{"key":"134_CR21","first-page":"381","volume":"11","author":"GB Moody","year":"1984","unstructured":"Moody, G. B., Muldrow, W. & Mark, R. G. A noise stress test for arrhythmia detectors. Comput. cardiol. 11, 381\u2013384 (1984).","journal-title":"Comput. cardiol."},{"key":"134_CR22","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1111\/j.1542-474X.2010.00359.x","volume":"15","author":"D Kireyev","year":"2010","unstructured":"Kireyev, D., Arkhipov, M. V., Zador, S. T., Paris, J. A. & Boden, W. E. Clinical utility of aVR\u2014the neglected electrocardiographic lead. Ann. Noninvasive Electrocardiol. 15, 175\u2013180 (2010).","journal-title":"Ann. Noninvasive Electrocardiol."},{"key":"134_CR23","doi-asserted-by":"publisher","first-page":"805","DOI":"10.1016\/j.amjcard.2013.04.058","volume":"112","author":"AO Badheka","year":"2013","unstructured":"Badheka, A. O. et al. ST-T wave abnormality in lead aVR and reclassification of cardiovascular risk (from the National Health and Nutrition Examination Survey-III). Am. J. Cardiol. 112, 805\u2013810 (2013).","journal-title":"Am. J. Cardiol."},{"key":"134_CR24","doi-asserted-by":"publisher","DOI":"10.1111\/anec.12719","volume":"25","author":"FA Ekizler","year":"2020","unstructured":"Ekizler, F. A. et al. Importance of lead aVR on predicting adverse cardiac events in patients with noncompaction cardiomyopathy. Ann. Noninvasive Electrocardiol. 25, e12719 (2020).","journal-title":"Ann. Noninvasive Electrocardiol."},{"key":"134_CR25","doi-asserted-by":"publisher","unstructured":"Nakayama, M. et al. Convolutional neural network models leverage morphological rather than temporal features to detect myocardial diseases from 12-lead electrocardiograms. Circ. Arrhythmia Electrophysiol. e014369. https:\/\/doi.org\/10.1161\/circep.125.014369 (2025).","DOI":"10.1161\/circep.125.014369"},{"key":"134_CR26","doi-asserted-by":"publisher","first-page":"1327179","DOI":"10.3389\/fcvm.2024.1327179","volume":"11","author":"A Saglietto","year":"2024","unstructured":"Saglietto, A. et al. Convolutional neural network (CNN)-enabled electrocardiogram (ECG) analysis: a comparison between standard twelve-lead and single-lead setups. Front. Cardiovasc. Med. 11, 1327179 (2024).","journal-title":"Front. Cardiovasc. Med."},{"key":"134_CR27","doi-asserted-by":"publisher","first-page":"1217","DOI":"10.3390\/s22031217","volume":"22","author":"N Sprenger","year":"2022","unstructured":"Sprenger, N. et al. Feasibility and reliability of smartwatch to obtain precordial lead electrocardiogram recordings. Sensors 22, 1217 (2022).","journal-title":"Sensors"},{"key":"134_CR28","doi-asserted-by":"publisher","first-page":"373","DOI":"10.1093\/ehjdh\/ztac030","volume":"3","author":"ZI Attia","year":"2022","unstructured":"Attia, Z. I. et al. Automated detection of low ejection fraction from a one-lead electrocardiogram: application of an AI algorithm to an electrocardiogram-enabled Digital Stethoscope. Eur. Heart J. Digit. Health 3, 373\u2013379 (2022).","journal-title":"Eur. Heart J. Digit. Health"},{"key":"134_CR29","doi-asserted-by":"publisher","first-page":"e117","DOI":"10.1016\/S2589-7500(21)00256-9","volume":"4","author":"P Bachtiger","year":"2022","unstructured":"Bachtiger, P. et al. Point-of-care screening for heart failure with reduced ejection fraction using artificial intelligence during ECG-enabled stethoscope examination in London, UK: a prospective, observational, multicentre study. Lancet. Digit. Health 4, e117\u2013e125 (2022).","journal-title":"Lancet. Digit. Health"},{"key":"134_CR30","first-page":"24","volume":"30","author":"K Hirai","year":"2024","unstructured":"Hirai, K. et al. Initial trial of three-lead wearable electrocardiogram monitoring in a full marathon. J. Cardiol. Cases 30, 24\u201328 (2024).","journal-title":"J. Cardiol. Cases"},{"key":"134_CR31","doi-asserted-by":"publisher","first-page":"1318","DOI":"10.3390\/s24041318","volume":"24","author":"ES Dahiya","year":"2024","unstructured":"Dahiya, E. S., Kalra, A. M., Lowe, A. & Anand, G. Wearable technology for monitoring electrocardiograms (ECGs) in adults: a scoping review. Sensors 24, 1318 (2024).","journal-title":"Sensors"},{"key":"134_CR32","doi-asserted-by":"publisher","first-page":"e2415576","DOI":"10.1001\/jamanetworkopen.2024.15576","volume":"7","author":"JZ Metcalfe","year":"2024","unstructured":"Metcalfe, J. Z. et al. Validation of a handheld 6-lead device for QT interval monitoring in resource-limited settings. JAMA Netw. Open 7, e2415576 (2024).","journal-title":"JAMA Netw. Open"},{"key":"134_CR33","doi-asserted-by":"publisher","first-page":"101573","DOI":"10.1016\/j.ijcha.2024.101573","volume":"56","author":"J Choi","year":"2025","unstructured":"Choi, J. et al. Smartwatch ECG and artificial intelligence in detecting acute coronary syndrome compared to traditional 12-lead ECG. IJC Heart Vasc. 56, 101573 (2025).","journal-title":"IJC Heart Vasc."},{"key":"134_CR34","doi-asserted-by":"publisher","first-page":"e0210103","DOI":"10.1371\/journal.pone.0210103","volume":"14","author":"S Goto","year":"2019","unstructured":"Goto, S. et al. Artificial intelligence to predict needs for urgent revascularization from 12-leads electrocardiography in emergency patients. PLoS ONE 14, e0210103 (2019).","journal-title":"PLoS ONE"},{"key":"134_CR35","doi-asserted-by":"publisher","first-page":"100582","DOI":"10.1016\/j.jacadv.2023.100582","volume":"2","author":"KC Siontis","year":"2023","unstructured":"Siontis, K. C. et al. Patient-level artificial intelligence-enhanced electrocardiography in hypertrophic cardiomyopathy longitudinal treatment and clinical biomarker correlations. JACC Adv. 2, 100582 (2023).","journal-title":"JACC Adv."},{"key":"134_CR36","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1038\/s41746-021-00550-0","volume":"5","author":"C Lin","year":"2022","unstructured":"Lin, C. et al. Point-of-care artificial intelligence-enabled ECG for dyskalemia: a retrospective cohort analysis for accuracy and outcome prediction. npj Digit. Med. 5, 8 (2022).","journal-title":"npj Digit. Med."},{"key":"134_CR37","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-023-29989-9","volume":"13","author":"GR Chaudhari","year":"2023","unstructured":"Chaudhari, G. R. et al. Deep learning augmented ECG analysis to identify biomarker-defined myocardial injury. Sci. Rep. 13, 3364 (2023).","journal-title":"Sci. Rep."},{"key":"134_CR38","doi-asserted-by":"publisher","first-page":"102","DOI":"10.31662\/jmaj.2024-0195","volume":"8","author":"M Nakayama","year":"2025","unstructured":"Nakayama, M., Yagi, R. & Goto, S. Deep learning applications in 12-lead electrocardiogram and echocardiogram. JMA J. 8, 102\u2013112 (2025).","journal-title":"JMA J."},{"key":"134_CR39","doi-asserted-by":"publisher","unstructured":"Kagiyama, N. et al. PRIME 2.0: an update to the proposed requirements for cardiovascular imaging-related machine learning evaluation checklist. JACC Cardiovasc. Imaging https:\/\/doi.org\/10.1016\/j.jcmg.2025.08.004 (2025).","DOI":"10.1016\/j.jcmg.2025.08.004"}],"container-title":["npj Cardiovascular Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s44325-026-00134-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s44325-026-00134-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s44325-026-00134-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T04:43:48Z","timestamp":1780634628000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s44325-026-00134-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,20]]},"references-count":39,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["134"],"URL":"https:\/\/doi.org\/10.1038\/s44325-026-00134-5","relation":{},"ISSN":["2948-2836"],"issn-type":[{"value":"2948-2836","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,20]]},"assertion":[{"value":"9 December 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 May 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 May 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"R.Y. is supported by a postdoctoral fellowship from the American Heart Association (AHA). S.G. is partially supported by AHA\u2019s Second Century Early Faculty Independence Award. R.C.D. is a co-founder of Atman Health. C.A.M. is supported by the One Brave Idea Award (AHA, Verily, and AstraZeneca, with additional support from Quest Diagnostics) and is a co-founder of Atman Health and Tanaist. M.N., K.D., and Y.K. declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"34"}}