{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,28]],"date-time":"2026-02-28T14:16:58Z","timestamp":1772288218454,"version":"3.50.1"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2015,9,24]],"date-time":"2015-09-24T00:00:00Z","timestamp":1443052800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2015,9,24]],"date-time":"2015-09-24T00:00:00Z","timestamp":1443052800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Reliably interfacing a nerve with an electrode array is one of the approaches to restore motor and sensory functions after an injury to the peripheral nerve. Accomplishing this with current technologies is challenging as the electrode-neuron interface often degrades over time and surrounding myoelectric signals contaminate the neuro-signals in awake, moving animals. The purpose of this study was to evaluate the potential of microchannel electrode implants to monitor over time and in freely moving animals, neural activity from regenerating nerves. We designed and fabricated implants with silicone rubber and elastic thin-film metallization. Each implant carries an eight-by-twelve matrix of parallel microchannels (of 120\u2009\u00d7\u2009110\u2009\u03bcm<jats:sup>2<\/jats:sup> cross-section and 4\u2009mm length) and gold thin-film electrodes embedded in the floor of ten of the microchannels. After sterilization, the soft, multi-lumen electrode implant is sutured between the stumps of the sciatic nerve. Over a period of three months and in four rats, the microchannel electrodes recorded spike activity from the regenerating sciatic nerve. Histology indicates mini-nerves formed of axons and supporting cells regenerate robustly in the implants. Analysis of the recorded spikes and gait kinematics over the ten-week period suggests firing patterns collected with the microchannel electrode implant can be associated with different phases of gait.<\/jats:p>","DOI":"10.1038\/srep14363","type":"journal-article","created":{"date-parts":[[2015,9,24]],"date-time":"2015-09-24T08:41:39Z","timestamp":1443084099000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":68,"title":["Chronic multichannel neural recordings from soft regenerative microchannel electrodes during gait"],"prefix":"10.1038","volume":"5","author":[{"given":"Katherine M.","family":"Musick","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jacopo","family":"Rigosa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shreya","family":"Narasimhan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sophie","family":"Wurth","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marco","family":"Capogrosso","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniel J.","family":"Chew","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"James W.","family":"Fawcett","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Silvestro","family":"Micera","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"St\u00e9phanie P.","family":"Lacour","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2015,9,24]]},"reference":[{"key":"BFsrep14363_CR1","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1111\/j.1085-9489.2005.10303.x","volume":"10","author":"X Navarro","year":"2005","unstructured":"Navarro, X. et al. A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems. Journal of the peripheral nervous system: JPNS 10, 229\u2013258, 10.1111\/j.1085-9489.2005.10303.x (2005).","journal-title":"Journal of the peripheral nervous system: JPNS"},{"key":"BFsrep14363_CR2","doi-asserted-by":"crossref","unstructured":"Goroszeniuk, T. & Pang, D. Peripheral Neuromodulation: A Review. Curr Pain Headache R 18, 10.1007\/S11916-014-0412-9 (2014).","DOI":"10.1007\/s11916-014-0412-9"},{"key":"BFsrep14363_CR3","doi-asserted-by":"publisher","first-page":"045003","DOI":"10.1088\/1741-2560\/10\/4\/045003","volume":"10","author":"HA Wark","year":"2013","unstructured":"Wark, H. A. et al. A new high-density (25 electrodes\/mm2) penetrating microelectrode array for recording and stimulating sub-millimeter neuroanatomical structures. Journal of Neural Engineering 10, 045003 (2013).","journal-title":"Journal of Neural Engineering"},{"key":"BFsrep14363_CR4","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1109\/TBME.2003.820321","volume":"51","author":"A Branner","year":"2004","unstructured":"Branner, A., Stein, R. B., Fernandez, E., Aoyagi, Y. & Normann, R. A. Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve. IEEE Trans Biomed Eng 51, 146\u2013157, 10.1109\/TBME.2003.820321 (2004).","journal-title":"IEEE Trans Biomed Eng"},{"key":"BFsrep14363_CR5","doi-asserted-by":"publisher","first-page":"222ra219","DOI":"10.1126\/scitranslmed.3006820","volume":"6","author":"S Raspopovic","year":"2014","unstructured":"Raspopovic, S. et al. Restoring Natural Sensory Feedback in Real-Time Bidirectional Hand Prostheses. Science Translational Medicine 6, 222ra219 (2014).","journal-title":"Science Translational Medicine"},{"key":"BFsrep14363_CR6","doi-asserted-by":"publisher","first-page":"257ra138","DOI":"10.1126\/scitranslmed.3008669","volume":"6","author":"DW Tan","year":"2014","unstructured":"Tan, D. W. et al. A neural interface provides long-term stable natural touch perception. Sci Transl Med 6, 257ra138, 10.1126\/scitranslmed.3008669 (2014).","journal-title":"Sci Transl Med"},{"key":"BFsrep14363_CR7","doi-asserted-by":"publisher","first-page":"257re256","DOI":"10.1126\/scitranslmed.3008933","volume":"6","author":"M Ortiz-Catalan","year":"2014","unstructured":"Ortiz-Catalan, M., Hakansson, B. & Branemark, R. An osseointegrated human-machine gateway for long-term sensory feedback and motor control of artificial limbs. Sci Transl Med 6, 257re256, 10.1126\/scitranslmed.3008933 (2014).","journal-title":"Sci Transl Med"},{"key":"BFsrep14363_CR8","doi-asserted-by":"publisher","first-page":"399","DOI":"10.1038\/Nrd4351","volume":"13","author":"K Birmingham","year":"2014","unstructured":"Birmingham, K. et al. Bioelectronic medicines: a research roadmap. Nat Rev Drug Discov 13, 399\u2013400, 10.1038\/Nrd4351 (2014).","journal-title":"Nat Rev Drug Discov"},{"key":"BFsrep14363_CR9","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1016\/0165-0270(95)00143-3","volume":"65","author":"WM Grill","year":"1996","unstructured":"Grill, W. M. & Mortimer, J. T. Non-invasive measurement of the input-output properties of peripheral nerve stimulating electrodes. Journal of Neuroscience Methods 65, 43\u201350, 10.1016\/0165-0270(95)00143-3 (1996).","journal-title":"Journal of Neuroscience Methods"},{"key":"BFsrep14363_CR10","doi-asserted-by":"publisher","first-page":"036016","DOI":"10.1088\/1741-2560\/10\/3\/036016","volume":"10","author":"M Schuettler","year":"2013","unstructured":"Schuettler, M., Donaldson, N., Seetohul, V. & Taylor, J. Fibre-selective recording from the peripheral nerves of frogs using a multi-electrode cuff. Journal of Neural Engineering 10, 036016 (2013).","journal-title":"Journal of Neural Engineering"},{"key":"BFsrep14363_CR11","doi-asserted-by":"crossref","unstructured":"Ortiz-Catalan, M., Marin-Millan, J., Delbeke, J., Hakansson, B. & Branemark, R. Effect on signal-to-noise ratio of splitting the continuous contacts of cuff electrodes into smaller recording areas. J Neuroeng Rehabil 10, 10.1186\/1743-0003-10-22 (2013).","DOI":"10.1186\/1743-0003-10-22"},{"key":"BFsrep14363_CR12","doi-asserted-by":"publisher","first-page":"1461","DOI":"10.1109\/Tbme.2005.851482","volume":"52","author":"PB Yoo","year":"2005","unstructured":"Yoo, P. B. & Durand, D. A. Selective recording of the canine hypoglossal nerve using a multicontact flat interface nerve electrode. Ieee Transactions on Biomedical Engineering 52, 1461\u20131469, 10.1109\/Tbme.2005.851482 (2005).","journal-title":"Ieee Transactions on Biomedical Engineering"},{"key":"BFsrep14363_CR13","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1114\/1.1569263","volume":"31","author":"DJ Tyler","year":"2003","unstructured":"Tyler, D. J. & Durand, D. M. Chronic response of the rat sciatic nerve to the flat interface nerve electrode. Ann Biomed Eng 31, 633\u2013642, 10.1114\/1.1569263 (2003).","journal-title":"Ann Biomed Eng"},{"key":"BFsrep14363_CR14","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1109\/TNSRE.2004.831491","volume":"12","author":"SM Lawrence","year":"2004","unstructured":"Lawrence, S. M., Dhillon, G. S., Jensen, W., Yoshida, K. & Horch, K. W. Acute peripheral nerve recording characteristics of polymer-based longitudinal intrafascicular electrodes. IEEE Translation on Neural Systems and Rehabilitation Engineering 12, 345\u2013348 (2004).","journal-title":"IEEE Translation on Neural Systems and Rehabilitation Engineering"},{"key":"BFsrep14363_CR15","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1016\/j.bios.2010.05.010","volume":"26","author":"T Boretius","year":"2010","unstructured":"Boretius, T. et al. A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve. Biosensors & bioelectronics 26, 62\u201369, 10.1016\/j.bios.2010.05.010 (2010).","journal-title":"Biosensors & bioelectronics"},{"key":"BFsrep14363_CR16","doi-asserted-by":"publisher","first-page":"305","DOI":"10.1109\/10.284958","volume":"41","author":"T Akin","year":"1994","unstructured":"Akin, T., Najafi, K., Smoke, R. H. & Bradley, R. M. A Micromachined Silicon Sieve Electrode for Nerve Regeneration Applications. Ieee Transactions on Biomedical Engineering 41, 305\u2013313, 10.1109\/10.284958 (1994).","journal-title":"Ieee Transactions on Biomedical Engineering"},{"key":"BFsrep14363_CR17","doi-asserted-by":"publisher","first-page":"240","DOI":"10.1016\/S0924-4247(97)01494-5","volume":"60","author":"T Stieglitz","year":"1997","unstructured":"Stieglitz, T., Beutel, H. & Meyer, J.-U. A flexible, light-weighted, multichannel sieve electrode with integrated cables for interfacing regenerating peripheral nerves. Sensors and Actuators A 60, 240\u2013243 (1997).","journal-title":"Sensors and Actuators A"},{"key":"BFsrep14363_CR18","doi-asserted-by":"publisher","first-page":"2333","DOI":"10.1016\/S0142-9612(00)00420-8","volume":"22","author":"PM Klinge","year":"2001","unstructured":"Klinge, P. M. et al. Immunohistochemical characterization of axonal sprouting and reactive tissue changes after long-term implantation of a polyimide sieve electrode to the transected adult rat sciatic nerve. Biomaterials 22, 2333\u20132343, 10.1016\/S0142-9612(00)00420-8 (2001).","journal-title":"Biomaterials"},{"key":"BFsrep14363_CR19","doi-asserted-by":"publisher","first-page":"016010","DOI":"10.1088\/1741-2560\/9\/1\/016010","volume":"9","author":"JJ FitzGerald","year":"2012","unstructured":"FitzGerald, J. J. et al. A regenerative microchannel neural interface for recording from and stimulating peripheral axons in vivo. Journal of Neural Engineering 9, 016010, 10.1088\/1741-2560\/9\/1\/016010 (2012).","journal-title":"Journal of Neural Engineering"},{"key":"BFsrep14363_CR20","doi-asserted-by":"crossref","unstructured":"Chew, D. J. et al. A Microchannel Neuroprosthesis for Bladder Control After Spinal Cord Injury in Rat. Science Translational Medicine 5, doi: ARTN 210ra15, 10.1126\/scitranslmed.3007186 (2013).","DOI":"10.1126\/scitranslmed.3007186"},{"key":"BFsrep14363_CR21","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1016\/J.Biomaterials.2014.11.035","volume":"41","author":"A Srinivasan","year":"2015","unstructured":"Srinivasan, A. et al. Microchannel-based regenerative scaffold for chronic peripheral nerve interfacing in amputees. Biomaterials 41, 151\u2013165, 10.1016\/J.Biomaterials.2014.11.035 (2015).","journal-title":"Biomaterials"},{"key":"BFsrep14363_CR22","doi-asserted-by":"publisher","first-page":"1136","DOI":"10.1109\/TBME.2007.909533","volume":"55","author":"J FitzGerald","year":"2008","unstructured":"FitzGerald, J., Lacour, S. P., McMahon, S. & Fawcett, J. Microchannels as axonal amplifiers. IEEE Transactions on Biomedical Engineering 55, 1136\u20131146 (2008).","journal-title":"IEEE Transactions on Biomedical Engineering"},{"key":"BFsrep14363_CR23","doi-asserted-by":"crossref","unstructured":"Gore, R. K., Choi, Y. S., Bellamkonda, R. & English, A. Functional recordings from awake, behaving rodents through a microchannel based regenerative neural interface. Journal of Neural Engineering 12, doi:Artn 016017, 10.1088\/1741-2560\/12\/1\/016017 (2015).","DOI":"10.1088\/1741-2560\/12\/1\/016017"},{"key":"BFsrep14363_CR24","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1126\/science.1260318","volume":"347","author":"IR Minev","year":"2015","unstructured":"Minev, I. R. et al. Biomaterials. Electronic dura mater for long-term multimodal neural interfaces. Science 347, 159\u2013163, 10.1126\/science.1260318 (2015).","journal-title":"Science"},{"key":"BFsrep14363_CR25","doi-asserted-by":"publisher","first-page":"777","DOI":"10.1016\/S0142-9612(02)00415-5","volume":"24","author":"X Cui","year":"2003","unstructured":"Cui, X., Wiler, J., Dzaman, M., Altschuler, R. A. & Martin, D. C. In vivo studies of polypyrrole\/peptide coated neural probes. Biomaterials 24, 777\u2013787 (2003).","journal-title":"Biomaterials"},{"key":"BFsrep14363_CR26","doi-asserted-by":"publisher","first-page":"026028","DOI":"10.1088\/1741-2560\/9\/2\/026028","volume":"9","author":"A Prasad","year":"2012","unstructured":"Prasad, A. & Sanchez, J. C. Quantifying long-term microelectrode array functionality using chronic in vivo impedance testing. J Neural Eng 9, 026028, 10.1088\/1741-2560\/9\/2\/026028 (2012).","journal-title":"J Neural Eng"},{"key":"BFsrep14363_CR27","doi-asserted-by":"publisher","first-page":"026016","DOI":"10.1088\/1741-2560\/11\/2\/026016","volume":"11","author":"X Xie,","year":"2014","unstructured":"Xie, X. et al. Long-term reliability of Al2O3 and Parylene C bilayer encapsulated Utah electrode array based neural interfaces for chronic implantation. Journal of Neural Engineering 11, 026016 (2014).","journal-title":"Journal of Neural Engineering"},{"key":"BFsrep14363_CR28","doi-asserted-by":"publisher","first-page":"267","DOI":"10.3109\/17453679209154780","volume":"63","author":"MK Kwan","year":"1992","unstructured":"Kwan, M. K., Wall, E. J., Massie, J. & Garfin, S. R. Strain, Stress and Stretch of Peripheral-Nerve - Rabbit Experiments Invitro and Invivo. Acta Orthop Scand 63, 267\u2013272, 10.3109\/17453679209154780 (1992).","journal-title":"Acta Orthop Scand"},{"key":"BFsrep14363_CR29","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1016\/S0022-4804(03)00255-5","volume":"114","author":"GH Borschel","year":"2003","unstructured":"Borschel, G. H., Kia, K. F., Kuzon, W. M. & Dennis, R. G. Mechanical properties of acellular peripheral nerve. J Surg Res 114, 133\u2013139, 10.1016\/S0022-4804(03)00255-5 (2003).","journal-title":"J Surg Res"},{"key":"BFsrep14363_CR30","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1016\/j.jneumeth.2008.04.025","volume":"172","author":"L Citi","year":"2008","unstructured":"Citi, L. et al. On the use of wavelet denoising and spike sorting techniques to process electroneurographic signals recorded using intraneural electrodes. J Neurosci Methods 172, 294\u2013302, 10.1016\/j.jneumeth.2008.04.025 (2008).","journal-title":"J Neurosci Methods"},{"key":"BFsrep14363_CR31","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1186\/1743-0003-9-23","volume":"9","author":"B Caulfield","year":"2012","unstructured":"Caulfield, B., Conway, T. A. & Micera, S. European study of research and development in mobility technology for persons with disabilities. J Neuroeng Rehabil 9, 23, 10.1186\/1743-0003-9-23 (2012).","journal-title":"J Neuroeng Rehabil"},{"key":"BFsrep14363_CR32","doi-asserted-by":"crossref","unstructured":"Musick, K. M., Chew, D. J., Fawcett, J. W. & Lacour, S. P. PDMS Microchannel Regenerative Peripheral Nerve Interface. I Ieee Embs C Neur E 649\u2013652 (2013).","DOI":"10.1109\/NER.2013.6696018"},{"key":"BFsrep14363_CR33","doi-asserted-by":"publisher","first-page":"204103","DOI":"10.1063\/1.2201874","volume":"88","author":"SP Lacour","year":"2006","unstructured":"Lacour, S. P., Chan, D., Wagner, S., Li, T. & Suo, Z. Mechanisms of reversible stretchability of thin metal films on elastomeric substrates. Applied Physics Letters 88, 204103 (2006).","journal-title":"Applied Physics Letters"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/srep14363","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/srep14363.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/srep14363.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,6]],"date-time":"2023-01-06T00:11:36Z","timestamp":1672963896000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/srep14363"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,9,24]]},"references-count":33,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2015,11,26]]}},"alternative-id":["BFsrep14363"],"URL":"https:\/\/doi.org\/10.1038\/srep14363","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,9,24]]},"assertion":[{"value":"8 July 2015","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 August 2015","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 September 2015","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing financial interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"14363"}}