{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T14:24:40Z","timestamp":1790778280445,"version":"4.1.0"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2016,2,25]],"date-time":"2016-02-25T00:00:00Z","timestamp":1456358400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2016,2,25]],"date-time":"2016-02-25T00:00:00Z","timestamp":1456358400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Equipped with a third hand under their direct control, surgeons may be able to perform certain surgical interventions alone; this would reduce the need for a human assistant and related coordination difficulties. However, does human performance improve with three hands compared to two hands? To evaluate this possibility, we carried out a behavioural study on the performance of naive adults catching objects with three virtual hands controlled by their two hands and right foot. The subjects could successfully control the virtual hands in a few trials. With this control strategy, the workspace of the hands was inversely correlated with the task velocity. The comparison of performance between the three and two hands control revealed no significant difference of success in catching falling objects and in average effort during the tasks. Subjects preferred the three handed control strategy, found it easier, with less physical and mental burden. Although the coordination of the foot with the natural hands increased trial after trial, about two minutes of practice was not sufficient to develop a sense of ownership towards the third arm.<\/jats:p>","DOI":"10.1038\/srep21758","type":"journal-article","created":{"date-parts":[[2016,2,25]],"date-time":"2016-02-25T05:07:28Z","timestamp":1456376848000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":58,"title":["In a demanding task, three-handed manipulation is preferred to two-handed manipulation"],"prefix":"10.1038","volume":"6","author":[{"given":"Elahe","family":"Abdi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Etienne","family":"Burdet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohamed","family":"Bouri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sharifa","family":"Himidan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hannes","family":"Bleuler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2016,2,25]]},"reference":[{"key":"BFsrep21758_CR1","unstructured":"Dong-Soo Kwon, S.-Y. K. a. J. K. In Medical Robotics (ed Vanja Bozovic ) Ch. 15, 197\u2013218 (2008)."},{"key":"BFsrep21758_CR2","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1007\/s004640000228","volume":"14","author":"T Kimura","year":"2000","unstructured":"Kimura, T., Umehara, Y. & Matsumoto, S. Laparoscopic cholecystectomy performed by a single surgeon using a visual field tracking camera - Early experience. Surgical Endoscopy-Ultrasound and Interventional Techniques 14, 825\u2013829, doi: 10.1007\/s004640000228 (2000).","journal-title":"Surgical Endoscopy-Ultrasound and Interventional Techniques"},{"key":"BFsrep21758_CR3","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1016\/s1569-9056(07)60650-2","volume":"6","author":"A Rane","year":"2007","unstructured":"Rane, A., Kommu, S., Eddy, B., Rimington, P. & Anderson, C. Initial experience with the endoassist (R) camera holding robot in laparoscopic urological surgery. European Urology Supplements 6, 186\u2013186, doi: 10.1016\/s1569-9056(07)60650-2 (2007).","journal-title":"European Urology Supplements"},{"key":"BFsrep21758_CR4","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1109\/51.391775","volume":"14","author":"PA Finlay","year":"1995","unstructured":"Finlay, P. A. & Ornstein, M. H. Controlling the movement of a surgical laparoscope - endosista(tm) with 4 degrees of freedom, operates in concert with surgeons intuitive head motions. IEEE Engineering in Medicine and Biology Magazine 14, 289\u2013291, doi: 10.1109\/51.391775 (1995).","journal-title":"IEEE Engineering in Medicine and Biology Magazine"},{"key":"BFsrep21758_CR5","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1097\/00019509-200006000-00013","volume":"10","author":"Y Yavuz","year":"2000","unstructured":"Yavuz, Y., Ystgaard, B., Skogvoll, E. & Marvik, R. A comparative experimental study evaluating the performance of surgical robots aesop and endosista. Surgical laparoscopy, endoscopy & percutaneous techniques 10, 163\u2013167, doi: 10.1097\/00019509-200006000-00013 (2000).","journal-title":"Surgical laparoscopy, endoscopy & percutaneous techniques"},{"key":"BFsrep21758_CR6","doi-asserted-by":"publisher","first-page":"1131","DOI":"10.1007\/BF00705739","volume":"8","author":"SW Unger","year":"1994","unstructured":"Unger, S. W., Unger, H. M. & Bass, R. T. AESOP robotic arm. Surgical Endoscopy 8, 1131 (1994).","journal-title":"Surgical Endoscopy"},{"key":"BFsrep21758_CR7","doi-asserted-by":"publisher","first-page":"580","DOI":"10.1007\/s001040050861","volume":"71","author":"H Niebuhr","year":"2000","unstructured":"Niebuhr, H. & Born, O. Image Tracking System. A new technique for safe and cost-effective laparoscopic surgery. Chirurg 71, 580\u2013584, doi: 10.1007\/s001040050861 (2000).","journal-title":"Chirurg"},{"key":"BFsrep21758_CR8","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1016\/s1074-3804(05)60015-1","volume":"11","author":"R Polet","year":"2004","unstructured":"Polet, R. & Donnez, J. Gynecologic laparoscopic surgery with a palm-controlled laparoscope holder. Journal of the American Association of Gynecologic Laparoscopists 11, 73\u201378, doi: 10.1016\/s1074-3804(05)60015-1 (2004).","journal-title":"Journal of the American Association of Gynecologic Laparoscopists"},{"key":"BFsrep21758_CR9","doi-asserted-by":"publisher","first-page":"528","DOI":"10.1007\/s004649901029","volume":"13","author":"MO Schurr","year":"1999","unstructured":"Schurr, M. O. et al. Trocar and instrument positioning system TISKA - An assist device for endoscopic solo surgery. Surgical Endoscopy-Ultrasound and Interventional Techniques 13, 528\u2013531, doi: 10.1007\/s004649901029 (1999).","journal-title":"Surgical Endoscopy-Ultrasound and Interventional Techniques"},{"key":"BFsrep21758_CR10","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1097\/01.sle.0000129395.42501.5d","volume":"14","author":"JEN Jaspers","year":"2004","unstructured":"Jaspers, J. E. N., Breedveld, P., Herder, J. L. & Grimbergen, C. A. Camera and instrument holders and their clinical value in minimally invasive surgery. Surgical Laparoscopy Endoscopy & Percutaneous Techniques 14, 145\u2013152, doi: 10.1097\/01.sle.0000129395.42501.5d (2004).","journal-title":"Surgical Laparoscopy Endoscopy & Percutaneous Techniques"},{"key":"BFsrep21758_CR11","doi-asserted-by":"publisher","first-page":"325","DOI":"10.3109\/13645709809152876","volume":"7","author":"F Voorhorst","year":"1998","unstructured":"Voorhorst, F., Meijer, D., Overbeeke, C. & Smets, G. Depth perception in laparoscopy through perception-action coupling. Minimally Invasive Therapy & Allied Technologies 7, 325\u2013334, doi: 10.3109\/13645709809152876 (1998).","journal-title":"Minimally Invasive Therapy & Allied Technologies"},{"key":"BFsrep21758_CR12","doi-asserted-by":"publisher","first-page":"1415","DOI":"10.1007\/s004649900871","volume":"12","author":"ME Allaf","year":"1998","unstructured":"Allaf, M. E. et al. Laparoscopic visual field. Voice vs foot pedal interfaces for control of the AESOP robot. Surg Endosc 12, 1415\u20131418 (1998).","journal-title":"Surg Endosc"},{"key":"BFsrep21758_CR13","doi-asserted-by":"publisher","first-page":"756","DOI":"10.1038\/35784","volume":"391","author":"M Botvinick","year":"1998","unstructured":"Botvinick, M. & Cohen, J. Rubber hands \u2018feel\u2019 touch that eyes see. Nature 391, 756\u2013756, doi: 10.1038\/35784 (1998).","journal-title":"Nature"},{"key":"BFsrep21758_CR14","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1016\/j.actpsy.2014.07.012","volume":"152","author":"M Riemer","year":"2014","unstructured":"Riemer, M. et al. The rubber hand illusion depends on a congruent mapping between real and artificial fingers. Acta Psychologica 152, 34\u201341, doi: 10.1016\/j.actpsy.2014.07.012 (2014).","journal-title":"Acta Psychologica"},{"key":"BFsrep21758_CR15","doi-asserted-by":"publisher","first-page":"2143","DOI":"10.1037\/a0037777","volume":"40","author":"LE Miller","year":"2014","unstructured":"Miller, L. E., Longo, M. R. & Saygin, A. P. Tool Morphology Constrains the Effects of Tool Use on Body Representations. Journal of Experimental Psychology-Human Perception and Performance 40, 2143\u20132153, doi: 10.1037\/a0037777 (2014).","journal-title":"Journal of Experimental Psychology-Human Perception and Performance"},{"key":"BFsrep21758_CR16","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1016\/j.concog.2014.04.010","volume":"27","author":"M Bertamini","year":"2014","unstructured":"Bertamini, M. & O\u2019Sullivan, N. The use of realistic and mechanical hands in the rubber hand illusion and the relationship to hemispheric differences. Consciousness and Cognition 27, 89\u201399, doi: 10.1016\/j.concog.2014.04.010 (2014).","journal-title":"Consciousness and Cognition"},{"key":"BFsrep21758_CR17","doi-asserted-by":"publisher","first-page":"978","DOI":"10.1016\/j.cognition.2007.12.004","volume":"107","author":"MR Longo","year":"2008","unstructured":"Longo, M. R., Schuur, F., Kammers, M. P. M., Tsakiris, M. & Haggard, P. What is embodiment? A psychometric approach. Cognition 107, 978\u2013998, doi: 10.1016\/j.cognition.2007.12.004 (2008).","journal-title":"Cognition"},{"key":"BFsrep21758_CR18","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1007\/s00221-009-2104-y","volume":"204","author":"R Newport","year":"2010","unstructured":"Newport, R., Pearce, R. & Preston, C. Fake hands in action: embodiment and control of supernumerary limbs. Experimental Brain Research 204, 385\u2013395, doi: 10.1007\/s00221-009-2104-y (2010).","journal-title":"Experimental Brain Research"},{"key":"BFsrep21758_CR19","doi-asserted-by":"publisher","first-page":"799","DOI":"10.1016\/j.concog.2012.02.008","volume":"21","author":"A Folegatti","year":"2012","unstructured":"Folegatti, A., Farne, A., Salemme, R. & de Vignemont, F. The Rubber Hand Illusion: Two\u2019s a company, but three\u2019s a crowd. Consciousness and Cognition 21, 799\u2013812, doi: 10.1016\/j.concog.2012.02.008 (2012).","journal-title":"Consciousness and Cognition"},{"key":"BFsrep21758_CR20","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1016\/j.neubiorev.2007.07.001","volume":"32","author":"MJ Giummarra","year":"2008","unstructured":"Giummarra, M. J., Gibson, S. J., Georgiou-Karistianis, N. & Bradshaw, J. L. Mechanisms underlying embodiment, disembodiment and loss of embodiment. Neuroscience and Biobehavioral Reviews 32, 143\u2013160, doi: 10.1016\/j.neubiorev.2007.07.001 (2008).","journal-title":"Neuroscience and Biobehavioral Reviews"},{"key":"BFsrep21758_CR21","doi-asserted-by":"publisher","first-page":"497","DOI":"10.1007\/s00221-013-3526-0","volume":"227","author":"A Senguel","year":"2013","unstructured":"Senguel, A. et al. Force feedback facilitates multisensory integration during robotic tool use. Experimental Brain Research 227, 497\u2013507, doi: 10.1007\/s00221-013-3526-0 (2013).","journal-title":"Experimental Brain Research"},{"key":"BFsrep21758_CR22","doi-asserted-by":"publisher","first-page":"109","DOI":"10.3389\/fnsys.2014.00109","volume":"8","author":"G Di Pino","year":"2014","unstructured":"Di Pino, G., Maravita, A., Zollo, L., Guglielmelli, E. & Di Lazzaro, V. Augmentation-related brain plasticity. Frontiers in systems neuroscience 8, 109\u2013109, doi: 10.3389\/fnsys.2014.00109 (2014).","journal-title":"Frontiers in systems neuroscience"},{"key":"BFsrep21758_CR23","doi-asserted-by":"publisher","first-page":"955","DOI":"10.1007\/s004640000106","volume":"14","author":"A Arezzo","year":"2000","unstructured":"Arezzo, A. et al. Experimental trial on solo surgery for minimally invasive therapy - Comparison of different systems in a phantom model. Surgical Endoscopy-Ultrasound and Interventional Techniques 14, 955\u2013959, doi: 10.1007\/s004640000106 (2000).","journal-title":"Surgical Endoscopy-Ultrasound and Interventional Techniques"},{"key":"BFsrep21758_CR24","doi-asserted-by":"crossref","unstructured":"Abdi, E. B. M., Himidan, S., Burdet, E., Bleuler, H. In New Trends in Medical and Service Robots Vol. 38 (ed H. Bleuler, Bouri, M., Mondada, F., Pisla, D., Rodi\u0107, A., Helmer, P.) 153\u2013164 (Springer, 2015).","DOI":"10.1007\/978-3-319-23832-6_13"},{"key":"BFsrep21758_CR25","doi-asserted-by":"crossref","unstructured":"Llorens-Bonilla, B., Asada, H. H. & Asme . Control and coordination of supernumerary robotic limbs based on human motion detection and task petri net model. Asme 2013 Dynamic Systems and Control Conference, 2, doi: 10.1115\/dscc2013-4083 (2013).","DOI":"10.1115\/DSCC2013-4083"},{"key":"BFsrep21758_CR26","doi-asserted-by":"crossref","unstructured":"Wu, F., Asada, H. & Asme . SUPERNUMERARY ROBOTIC FINGERS: AN ALTERNATIVE UPPER-LIMB PROSTHESIS. (2014).","DOI":"10.1115\/DSCC2014-6017"},{"key":"BFsrep21758_CR27","doi-asserted-by":"publisher","first-page":"2126","DOI":"10.1109\/tbme.2011.2179545","volume":"59","author":"S Balasubramanian","year":"2012","unstructured":"Balasubramanian, S., Melendez-Calderon, A. & Burdet, E. A Robust and Sensitive Metric for Quantifying Movement Smoothness. IEEE Transactions on Biomedical Engineering 59, 2126\u20132136, doi: 10.1109\/tbme.2011.2179545 (2012).","journal-title":"IEEE Transactions on Biomedical Engineering"},{"key":"BFsrep21758_CR28","doi-asserted-by":"crossref","unstructured":"Moeller, J. A word on standardization in longitudinal studies: don\u2019t. Frontiers in Psychology 6, doi: 10.3389\/fpsyg.2015.01389 (2015).","DOI":"10.3389\/fpsyg.2015.01389"},{"key":"BFsrep21758_CR29","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1007\/s11548-015-1213-2","volume":"10","author":"E Abdi","year":"2015","unstructured":"Abdi, E., Bouri, M., Himidan, S., Burdet, E. & Bleuler, H. Third arm for surgeon: two hands versus three hands CARS 2015\u2014Computer Assisted Radiology and Surgery Proceedings of the 29th International Congress and Exhibition Barcelona, Spain, June 24\u201327, 2015. International Journal of Computer Assisted Radiology and Surgery 10, 170\u2013171, doi: 10.1007\/s11548-015-1213-2 (2015).","journal-title":"International Journal of Computer Assisted Radiology and Surgery"},{"key":"BFsrep21758_CR30","doi-asserted-by":"publisher","first-page":"367","DOI":"10.1007\/s00221-006-0471-1","volume":"174","author":"RLJ Meesen","year":"2006","unstructured":"Meesen, R. L. J., Wenderoth, N., Temprado, J. J., Summers, J. J. & Swinnen, S. P. The coalition of constraints during coordination of the ipsilateral and heterolateral limbs. Experimental Brain Research 174, 367\u2013375, doi: 10.1007\/s00221-006-0471-1 (2006).","journal-title":"Experimental Brain Research"},{"key":"BFsrep21758_CR31","doi-asserted-by":"publisher","first-page":"e00108","DOI":"10.1002\/phy2.108","volume":"1","author":"K Nakagawa","year":"2013","unstructured":"Nakagawa, K., Muraoka, T. & Kanosue, K. Factors that determine directional constraint in ipsilateral hand-foot coordinated movements. Physiological reports 1, e00108\u2013e00108, doi: 10.1002\/phy2.108 (2013).","journal-title":"Physiological reports"},{"key":"BFsrep21758_CR32","doi-asserted-by":"crossref","unstructured":"Nakagawa, K., Muraoka, T. & Kanosue, K. Potential explanation of limb combination performance differences for two-limb coordination tasks. Physiological reports 3, doi: 10.14814\/phy2.12301 (2015).","DOI":"10.14814\/phy2.12301"},{"key":"BFsrep21758_CR33","doi-asserted-by":"publisher","first-page":"2607","DOI":"10.1007\/s00221-015-4333-6","volume":"233","author":"TL McIsaac","year":"2015","unstructured":"McIsaac, T. L. & Benjapalakorn, B. Allocation of attention and dual-task effects on upper and lower limb task performance in healthy young adults. Experimental Brain Research 233, 2607\u20132617, doi: 10.1007\/s00221-015-4333-6 (2015).","journal-title":"Experimental Brain Research"},{"key":"BFsrep21758_CR34","doi-asserted-by":"crossref","unstructured":"Simeone, A. L., Velloso, E., Alexander, J. & Gellersen, H. Feet Movement in Desktop 3D Interaction. 2014 Ieee Symposium on 3d User Interfaces (3dui), 71\u201374 (2014).","DOI":"10.1109\/3DUI.2014.6798845"},{"key":"BFsrep21758_CR35","doi-asserted-by":"crossref","unstructured":"Abdi, E., Burdet, E., Bouri, M. & Bleuler, H. Control of a Supernumerary Robotic Hand by Foot: An Experimental Study in Virtual Reality. Plos One 10, doi: 10.1371\/journal.pone.0134501 (2015).","DOI":"10.1371\/journal.pone.0134501"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/srep21758.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/srep21758","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/srep21758.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,4]],"date-time":"2023-01-04T22:39:41Z","timestamp":1672871981000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/srep21758"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,2,25]]},"references-count":35,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2016,2,26]]}},"alternative-id":["BFsrep21758"],"URL":"https:\/\/doi.org\/10.1038\/srep21758","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,2,25]]},"assertion":[{"value":"24 August 2015","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 January 2016","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 February 2016","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing financial interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"21758"}}