{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T00:07:28Z","timestamp":1793318848134,"version":"4.5.0"},"reference-count":14,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2016,5,6]],"date-time":"2016-05-06T00:00:00Z","timestamp":1462492800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2016,5,6]],"date-time":"2016-05-06T00:00:00Z","timestamp":1462492800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Presbyopia, the loss of the eye\u2019s accommodation capability, affects all humans aged above 45\u201350 years old. The two main reasons for this to happen are a hardening of the crystalline lens and a reduction of the ciliary muscle functionality with age. While there seems to be at least some partial accommodating functionality of the ciliary muscle at early presbyopic ages, it is not yet clear whether the muscle is still active at more advanced ages. Previous techniques used to visualize the accommodation mechanism of the ciliary muscle are complicated to apply in the older subjects, as they typically require fixation stability during long measurement times and\/or to have an ultrasound probe directly in contact with the eye. Instead, we used our own developed method based on high-speed recording of lens wobbling to study the ciliary muscle activity in a small group of pseudophakic subjects (around 80 years old). There was a significant activity of the muscle, clearly able to contract under binocular stimulation of accommodation. This supports a purely lenticular-based theory of presbyopia and it might stimulate the search for new solutions to presbyopia by making use of the remaining contraction force still presented in the aging eye.<\/jats:p>","DOI":"10.1038\/srep25551","type":"journal-article","created":{"date-parts":[[2016,5,6]],"date-time":"2016-05-06T10:53:53Z","timestamp":1462532033000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":39,"title":["The accommodative ciliary muscle function is preserved in older humans"],"prefix":"10.1038","volume":"6","author":[{"given":"Juan","family":"Tabernero","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emmanuel","family":"Chirre","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lucia","family":"Hervella","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pedro","family":"Prieto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pablo","family":"Artal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2016,5,6]]},"reference":[{"key":"BFsrep25551_CR1","doi-asserted-by":"publisher","first-page":"1469","DOI":"10.1113\/jphysiol.1973.sp010111","volume":"228","author":"RF Fisher","year":"1973","unstructured":"Fisher, R. F. Presbyopia and the changes with age in the human crystalline lens. The J. Physiol. 228, 1469\u20137793 (1973).","journal-title":"The J. Physiol."},{"key":"BFsrep25551_CR2","doi-asserted-by":"publisher","first-page":"906","DOI":"10.1007\/s00417-002-0551-2","volume":"240","author":"O Stachs","year":"2002","unstructured":"Stachs, O. et al. Monitoring accommodative ciliary muscle function using three-dimensional ultrasound. Graefe\u2019s Archive for Clinical and Experimental Ophthalmology 240, 906\u2013912 (2002).","journal-title":"Graefe\u2019s Archive for Clinical and Experimental Ophthalmology"},{"key":"BFsrep25551_CR3","first-page":"1162","volume":"40","author":"SA Strenk","year":"1999","unstructured":"Strenk, S. A. et al. Age related changes in human ciliary muscle and lens: A magnetic resonance imaging study. Invest. Ophthalmol. Vis. Sci. 40, 1162\u20131169 (1999).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"BFsrep25551_CR4","doi-asserted-by":"publisher","first-page":"1792","DOI":"10.1016\/j.jcrs.2006.05.031","volume":"32","author":"SA Strenk","year":"2006","unstructured":"Strenk, S. A., Strenk, L. M. & Guo, S. Magnetic resonance imaging of aging, accommodating, phakic and pseudophakic ciliary muscle diameters. J. Cataract Refract. Surg. 32, 1792\u20131798 (2006).","journal-title":"J. Cataract Refract. Surg."},{"key":"BFsrep25551_CR5","doi-asserted-by":"publisher","first-page":"529","DOI":"10.1016\/0042-6989(94)00146-D","volume":"35","author":"H Deubel","year":"1995","unstructured":"Deubel, H. & Bridgeman, B. Fourth purkinje image signals reveal eye-lens deviations and retinal image distortions during saccades. Vision Res. 35, 529\u2013538 (1995).","journal-title":"Vision Res."},{"key":"BFsrep25551_CR6","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1167\/10.4.14","volume":"10","author":"L He","year":"2010","unstructured":"He, L., Donnelly III, W. J., Stevenson, S. B. & Glasser, A. Saccadic lens instability increases with accommodative stimulus in presbyopes. J. Vis. 10, 1\u201316 (2010).","journal-title":"J. Vis."},{"key":"BFsrep25551_CR7","doi-asserted-by":"publisher","first-page":"527","DOI":"10.1364\/AO.24.000527","volume":"24","author":"HD Crane","year":"1985","unstructured":"Crane, H. D. & Steele, C. M. Generation-V dual-Purkinje-image eye tracker. Appl. Optics 24, 527\u2013537 (1985).","journal-title":"Appl. Optics"},{"key":"BFsrep25551_CR8","doi-asserted-by":"publisher","first-page":"e95764","DOI":"10.1371\/journal.pone.0095764","volume":"9","author":"J Tabernero","year":"2014","unstructured":"Tabernero, J. & Artal, P. Lens Oscillations in the Human Eye. Implications for Post-Saccadic Suppression of Vision. PLOS One 9, e95764, 10.1371\/journal.pone.0095764 (2014).","journal-title":"PLOS One"},{"key":"BFsrep25551_CR9","doi-asserted-by":"publisher","first-page":"10945","DOI":"10.1364\/OE.14.010945","volume":"14","author":"J Tabernero","year":"2006","unstructured":"Tabernero, J., Benito, A., Nourrit, V. & Artal, P. Instrument for measuring the misalignments of ocular surfaces. Opt. Express 14, 10945\u201310956 (2006).","journal-title":"Opt. Express"},{"key":"BFsrep25551_CR10","doi-asserted-by":"publisher","first-page":"1809","DOI":"10.1167\/iovs.10-6447","volume":"52","author":"AL Sheppard","year":"2011","unstructured":"Sheppard, A. L. & Davies, L. N. The Effect of Ageing on in vivo Human Ciliary Muscle Morphology and Contractility. Invest. Ophthalmol. Vis. Sci. 52, 1809\u20131806 (2011).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"BFsrep25551_CR11","doi-asserted-by":"publisher","first-page":"1095","DOI":"10.1167\/iovs.12-10619","volume":"54","author":"K Richdale","year":"2013","unstructured":"Richdale, K. et al. Quantification of Age-Related and per Diopter Accommodative Changes of the Lens and Ciliary Muscle in the Emmetropic Human Eye. Invest. Ophthalmol. Vis. Sci. 54, 1095\u20131105 (2013).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"BFsrep25551_CR12","doi-asserted-by":"publisher","first-page":"4773","DOI":"10.1364\/OL.39.004773","volume":"39","author":"E Chirre","year":"2014","unstructured":"Chirre, E., Prieto, P. M. & Artal, P. Binocular open-view instrument to measure aberrations and pupillary dynamics. Opt. Lett. 39, 4773\u20134775 (2014).","journal-title":"Opt. Lett."},{"key":"BFsrep25551_CR13","doi-asserted-by":"publisher","first-page":"4200","DOI":"10.1364\/BOE.6.004200","volume":"6","author":"E Chirre","year":"2015","unstructured":"Chirre, E., Prieto, P. M. & Artal, P. Dynamics of the near response under natural viewing conditions with an open-view sensor. Biomed. Opt. Express 6, 4200\u20134211 (2015).","journal-title":"Biomed. Opt. Express"},{"key":"BFsrep25551_CR14","doi-asserted-by":"publisher","first-page":"1684","DOI":"10.1364\/JOSAA.14.001684","volume":"14","author":"H Liou","year":"1997","unstructured":"Liou, H. & Brennan, N. A. Anatomically accurate, finite model eye for optical modeling. J. Opt. Soc. Am. A 14, 1684\u20131695 (1997).","journal-title":"J. Opt. Soc. Am. A"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/srep25551","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/srep25551.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/srep25551.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,4]],"date-time":"2023-01-04T14:32:51Z","timestamp":1672842771000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/srep25551"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,5,6]]},"references-count":14,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2016,7,6]]}},"alternative-id":["BFsrep25551"],"URL":"https:\/\/doi.org\/10.1038\/srep25551","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,5,6]]},"assertion":[{"value":"21 January 2016","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 April 2016","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 May 2016","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing financial interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"25551"}}