{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T23:30:24Z","timestamp":1789774224829,"version":"4.0.1"},"reference-count":55,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2016,8,11]],"date-time":"2016-08-11T00:00:00Z","timestamp":1470873600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2016,8,11]],"date-time":"2016-08-11T00:00:00Z","timestamp":1470873600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Ultra-high resolution optical coherence tomography (UHR-OCT) can image the corneal epithelium and Bowman\u2019s layer and measurement the thicknesses. The purpose of this study was to validate the diagnostic power of vertical thickness profiles of the corneal epithelium and Bowman\u2019s layer imaged by UHR-OCT in the diagnosis of sub-clinical keratoconus (KC). Each eye of 37 KC patients, asymptomatic fellow eyes of 32 KC patients and each eye of 81 normal subjects were enrolled. Vertical thickness profiles of the corneal epithelium and Bowman\u2019s layer were measured by UHR-OCT. Diagnostic indices were calculated from vertical thickness profiles of each layer and output values of discriminant functions based on individual indices. Receiver operating characteristic curves were determined and the accuracy of the diagnostic indices were assessed as the area under the curves (AUC). Among all of the individual indices, the maximum ectasia index for epithelium had the highest ability to discriminate sub-clinical KC from normal corneas (AUC\u2009=\u20090.939). The discriminant function containing maximum ectasia indices of epithelium and Bowman\u2019s layer further increased the AUC value (AUC\u2009=\u20090.970) for sub-clinical KC diagnosis. UHR-OCT-derived thickness indices from the entire vertical thickness profiles of the corneal epithelium and Bowman\u2019s layer can provide valuable diagnostic references to detect sub-clinical KC.<\/jats:p>","DOI":"10.1038\/srep31550","type":"journal-article","created":{"date-parts":[[2016,8,11]],"date-time":"2016-08-11T09:51:34Z","timestamp":1470909094000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":35,"title":["Value of corneal epithelial and Bowman\u2019s layer vertical thickness profiles generated by UHR-OCT for sub-clinical keratoconus diagnosis"],"prefix":"10.1038","volume":"6","author":[{"given":"Zhe","family":"Xu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jun","family":"Jiang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chun","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shenghai","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mei","family":"Peng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Weibo","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lele","family":"Cui","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianhua","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fan","family":"Lu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Meixiao","family":"Shen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2016,8,11]]},"reference":[{"key":"BFsrep31550_CR1","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1016\/S0039-6257(97)00119-7","volume":"42","author":"YS Rabinowitz","year":"1998","unstructured":"Rabinowitz, Y. S. Keratoconus. Surv. Ophthalmol. 42, 297\u2013319 (1998).","journal-title":"Surv. Ophthalmol."},{"key":"BFsrep31550_CR2","doi-asserted-by":"publisher","first-page":"804","DOI":"10.1097\/00003226-200011000-00009","volume":"19","author":"K Zadnik","year":"2000","unstructured":"Zadnik, K. et al. Corneal scarring and vision in keratoconus: a baseline report from the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study. Cornea 19, 804\u2013812 (2000).","journal-title":"Cornea"},{"key":"BFsrep31550_CR3","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1016\/S0161-6420(02)01727-X","volume":"110","author":"JB Randleman","year":"2003","unstructured":"Randleman, J. B., Russell, B., Ward, M. A., Thompson, K. P. & Stulting, R. D. Risk factors and prognosis for corneal ectasia after LASIK. Ophthalmology 110, 267\u2013275 (2003).","journal-title":"Ophthalmology"},{"key":"BFsrep31550_CR4","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1016\/j.ophtha.2007.03.073","volume":"115","author":"JB Randleman","year":"2008","unstructured":"Randleman, J. B., Woodward, M., Lynn, M. J. & Stulting, R. D. Risk assessment for ectasia after corneal refractive surgery. Ophthalmology 115, 37\u201350 (2008).","journal-title":"Ophthalmology"},{"key":"BFsrep31550_CR5","doi-asserted-by":"publisher","first-page":"241","DOI":"10.3928\/1081597X-20100212-02","volume":"26","author":"PS Binder","year":"2010","unstructured":"Binder, P. S. & Trattler, W. B. Evaluation of a risk factor scoring system for corneal ectasia after LASIK in eyes with normal topography. J. Refract. Surg. 26, 241\u2013250 (2010).","journal-title":"J. Refract. Surg."},{"key":"BFsrep31550_CR6","doi-asserted-by":"publisher","first-page":"1948","DOI":"10.1167\/iovs.09-4177","volume":"51","author":"DP Pinero","year":"2010","unstructured":"Pinero, D. P., Alio, J. L., Barraquer, R. I., Michael, R. & Jimenez, R. Corneal biomechanics, refraction and corneal aberrometry in keratoconus: an integrated study. Invest Ophthalmol. Vis. Sci. 51, 1948\u20131955 (2010).","journal-title":"Invest Ophthalmol. Vis. Sci."},{"key":"BFsrep31550_CR7","doi-asserted-by":"publisher","first-page":"116010","DOI":"10.1117\/1.JBO.17.11.116010","volume":"17","author":"R Yadav","year":"2012","unstructured":"Yadav, R., Kottaiyan, R., Ahmad, K. & Yoon, G. Epithelium and Bowman\u2019s layer thickness and light scatter in keratoconic cornea evaluated using ultrahigh resolution optical coherence tomography. J. Biomed. Opt. 17, 116010 (2012).","journal-title":"J. Biomed. Opt."},{"key":"BFsrep31550_CR8","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1111\/j.1444-0938.2007.00195.x","volume":"91","author":"N Efron","year":"2008","unstructured":"Efron, N. & Hollingsworth, J. G. New perspectives on keratoconus as revealed by corneal confocal microscopy. Clin. Exp. Optom. 91, 34\u201355 (2008).","journal-title":"Clin. Exp. Optom."},{"key":"BFsrep31550_CR9","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1097\/PAT.0b013e3283511b42","volume":"44","author":"E Sykakis","year":"2012","unstructured":"Sykakis, E., Carley, F., Irion, L., Denton, J. & Hillarby, M. C. An in depth analysis of histopathological characteristics found in keratoconus. Pathology 44, 234\u2013239 (2012).","journal-title":"Pathology"},{"key":"BFsrep31550_CR10","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1097\/00003226-199705000-00016","volume":"16","author":"MC Kenney","year":"1997","unstructured":"Kenney, M. C., Nesburn, A. B., Burgeson, R. E., Butkowski, R. J. & Ljubimov, A. V. Abnormalities of the extracellular matrix in keratoconus corneas. Cornea 16, 345\u2013351 (1997).","journal-title":"Cornea"},{"key":"BFsrep31550_CR11","doi-asserted-by":"publisher","first-page":"473","DOI":"10.1006\/exer.2001.1157","volume":"74","author":"T Sherwin","year":"2002","unstructured":"Sherwin, T., Brookes, N. H., Loh, I. P., Poole, C. A. & Clover, G. M. Cellular incursion into Bowman\u2019s membrane in the peripheral cone of the keratoconic cornea. Exp. Eye Res. 74, 473\u2013482 (2002).","journal-title":"Exp. Eye Res."},{"key":"BFsrep31550_CR12","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1016\/S0161-6420(80)35145-2","volume":"87","author":"HD Perry","year":"1980","unstructured":"Perry, H. D., Buxton, J. N. & Fine, B. S. Round and oval cones in keratoconus. Ophthalmology 87, 905\u2013909 (1980).","journal-title":"Ophthalmology"},{"key":"BFsrep31550_CR13","doi-asserted-by":"publisher","first-page":"885","DOI":"10.1016\/j.ajo.2013.05.043","volume":"156","author":"EB Ozgurhan","year":"2013","unstructured":"Ozgurhan, E. B. et al. Evaluation of corneal microstructure in keratoconus: a confocal microscopy study. Am. J. Ophthalmol. 156, 885\u2013893 (2013).","journal-title":"Am. J. Ophthalmol."},{"key":"BFsrep31550_CR14","doi-asserted-by":"publisher","first-page":"988","DOI":"10.1016\/j.ophtha.2013.11.034","volume":"121","author":"M Abou Shousha","year":"2014","unstructured":"Abou Shousha, M. et al. The use of Bowman\u2019s layer vertical topographic thickness map in the diagnosis of keratoconus. Ophthalmology 121, 988\u2013993 (2014).","journal-title":"Ophthalmology"},{"key":"BFsrep31550_CR15","doi-asserted-by":"publisher","first-page":"259","DOI":"10.3928\/1081597X-20100218-01","volume":"26","author":"DZ Reinstein","year":"2010","unstructured":"Reinstein, D. Z., Gobbe, M., Archer, T. J., Silverman, R. H. & Coleman, D. J. Epithelial, stromal and total corneal thickness in keratoconus: three-dimensional display with artemis very-high frequency digital ultrasound. J. Refract. Surg. 26, 259\u2013271 (2010).","journal-title":"J. Refract. Surg."},{"key":"BFsrep31550_CR16","doi-asserted-by":"publisher","first-page":"2425","DOI":"10.1016\/j.ophtha.2012.06.023","volume":"119","author":"Y Li","year":"2012","unstructured":"Li, Y., Tan, O., Brass, R., Weiss, J. L. & Huang, D. Corneal epithelial thickness mapping by Fourier-domain optical coherence tomography in normal and keratoconic eyes. Ophthalmology 119, 2425\u20132433 (2012).","journal-title":"Ophthalmology"},{"key":"BFsrep31550_CR17","doi-asserted-by":"publisher","first-page":"604","DOI":"10.3928\/1081597X-20090610-06","volume":"25","author":"DZ Reinstein","year":"2009","unstructured":"Reinstein, D. Z., Archer, T. J. & Gobbe, M. Corneal epithelial thickness profile in the diagnosis of keratoconus. J. Refract. Surg. 25, 604\u2013610 (2009).","journal-title":"J. Refract. Surg."},{"key":"BFsrep31550_CR18","doi-asserted-by":"publisher","first-page":"1178","DOI":"10.1126\/science.1957169","volume":"254","author":"D Huang","year":"1991","unstructured":"Huang, D. et al. Optical coherence tomography. Science 254, 1178\u20131181 (1991).","journal-title":"Science"},{"key":"BFsrep31550_CR19","doi-asserted-by":"publisher","first-page":"173","DOI":"10.3928\/1081597X-20130129-08","volume":"29","author":"KM Rocha","year":"2013","unstructured":"Rocha, K. M., Perez-Straziota, C. E., Stulting, R. D. & Randleman, J. B. SD-OCT analysis of regional epithelial thickness profiles in keratoconus, postoperative corneal ectasia and normal eyes. J. Refract. Surg. 29, 173\u2013179 (2013).","journal-title":"J. Refract. Surg."},{"key":"BFsrep31550_CR20","doi-asserted-by":"publisher","first-page":"486","DOI":"10.3928\/1081-597X-20060501-11","volume":"22","author":"S Haque","year":"2006","unstructured":"Haque, S., Simpson, T. & Jones, L. Corneal and epithelial thickness in keratoconus: a comparison of ultrasonic pachymetry, Orbscan II and optical coherence tomography. J. Refract. Surg. 22, 486\u2013493 (2006).","journal-title":"J. Refract. Surg."},{"key":"BFsrep31550_CR21","doi-asserted-by":"publisher","first-page":"389","DOI":"10.1007\/s10384-014-0338-0","volume":"58","author":"N Maeda","year":"2014","unstructured":"Maeda, N. et al. Evaluation of corneal epithelial and stromal thickness in keratoconus using spectral-domain optical coherence tomography. Jpn. J. Ophthalmol. 58, 389\u2013395 (2014).","journal-title":"Jpn. J. Ophthalmol."},{"key":"BFsrep31550_CR22","doi-asserted-by":"publisher","first-page":"440","DOI":"10.1016\/j.ophtha.2003.06.020","volume":"111","author":"X Li","year":"2004","unstructured":"Li, X., Rabinowitz, Y. S., Rasheed, K. & Yang, H. Longitudinal study of the normal eyes in unilateral keratoconus patients. Ophthalmology 111, 440\u2013446 (2004).","journal-title":"Ophthalmology"},{"key":"BFsrep31550_CR23","doi-asserted-by":"publisher","first-page":"812","DOI":"10.1016\/j.jcrs.2014.06.043","volume":"41","author":"C Temstet","year":"2015","unstructured":"Temstet, C. et al. Corneal epithelial thickness mapping using Fourier-domain optical coherence tomography for detection of form fruste keratoconus. J. Cataract Refract. Surg. 41, 812\u2013820 (2015).","journal-title":"J. Cataract Refract. Surg."},{"key":"BFsrep31550_CR24","doi-asserted-by":"publisher","first-page":"80","DOI":"10.3928\/1081597X-20140120-02","volume":"30","author":"YS Rabinowitz","year":"2014","unstructured":"Rabinowitz, Y. S., Li, X., Canedo, A. L., Ambrosio, R. Jr. & Bykhovskaya, Y. Optical coherence tomography combined with videokeratography to differentiate mild keratoconus subtypes. J. Refract. Surg. 30, 80\u201387 (2014).","journal-title":"J. Refract. Surg."},{"key":"BFsrep31550_CR25","doi-asserted-by":"publisher","first-page":"3901","DOI":"10.1167\/iovs.09-4748","volume":"52","author":"A Tao","year":"2011","unstructured":"Tao, A. et al. Topographic thickness of Bowman\u2019s layer determined by ultra-high resolution spectral domain-optical coherence tomography. Invest Ophthalmol. Vis. Sci. 52, 3901\u20133907 (2011).","journal-title":"Invest Ophthalmol. Vis. Sci."},{"key":"BFsrep31550_CR26","doi-asserted-by":"publisher","first-page":"1384","DOI":"10.1167\/iovs.12-10979","volume":"54","author":"S Fukuda","year":"2013","unstructured":"Fukuda, S. et al. Keratoconus diagnosis using anterior segment polarization-sensitive optical coherence tomography. Invest Ophthalmol. Vis. Sci. 54, 1384\u20131391 (2013).","journal-title":"Invest Ophthalmol. Vis. Sci."},{"key":"BFsrep31550_CR27","doi-asserted-by":"publisher","first-page":"1948","DOI":"10.1167\/iovs.04-1253","volume":"46","author":"KM Meek","year":"2005","unstructured":"Meek, K. M. et al. Changes in collagen orientation and distribution in keratoconus corneas. Invest Ophthalmol. Vis. Sci. 46, 1948\u20131956 (2005).","journal-title":"Invest Ophthalmol. Vis. Sci."},{"key":"BFsrep31550_CR28","first-page":"121","volume":"38","author":"A Daxer","year":"1997","unstructured":"Daxer, A. & Fratzl, P. Collagen fibril orientation in the human corneal stroma and its implication in keratoconus. Invest Ophthalmol. Vis. Sci. 38, 121\u2013129 (1997).","journal-title":"Invest Ophthalmol. Vis. Sci."},{"key":"BFsrep31550_CR29","doi-asserted-by":"publisher","first-page":"709","DOI":"10.1016\/j.exer.2006.03.015","volume":"83","author":"WJ Dupps Jr.","year":"2006","unstructured":"Dupps, W. J. Jr. & Wilson, S. E. Biomechanics and wound healing in the cornea. Exp. Eye Res. 83, 709\u2013720 (2006).","journal-title":"Exp. Eye Res."},{"key":"BFsrep31550_CR30","doi-asserted-by":"publisher","first-page":"1580","DOI":"10.1167\/iovs.13-12578","volume":"55","author":"RH Silverman","year":"2014","unstructured":"Silverman, R. H. et al. Epithelial remodeling as basis for machine-based identification of keratoconus. Invest Ophthalmol. Vis. Sci. 55, 1580\u20131587 (2014).","journal-title":"Invest Ophthalmol. Vis. Sci."},{"key":"BFsrep31550_CR31","doi-asserted-by":"publisher","first-page":"1327","DOI":"10.1016\/S0886-3350(99)00195-9","volume":"25","author":"YS Rabinowitz","year":"1999","unstructured":"Rabinowitz, Y. S. & Rasheed, K. KISA% index: a quantitative videokeratography algorithm embodying minimal topographic criteria for diagnosing keratoconus. J. Cataract Refract. Surg. 25, 1327\u20131335 (1999).","journal-title":"J. Cataract Refract. Surg."},{"key":"BFsrep31550_CR32","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1016\/j.ajo.2006.11.062","volume":"143","author":"J Buhren","year":"2007","unstructured":"Buhren, J., Kuhne, C. & Kohnen, T. Defining subclinical keratoconus using corneal first-surface higher-order aberrations. Am. J. Ophthalmol. 143, 381\u2013389 (2007).","journal-title":"Am. J. Ophthalmol."},{"key":"BFsrep31550_CR33","first-page":"5","volume":"35","author":"MW Belin","year":"2007","unstructured":"Belin, M. W. & Khachikian, S. S. Corneal diagnosis and evaluation with the OCULUS Pentacam. Highlights of Ophthalmology 35, 5\u20138 (2007).","journal-title":"Highlights of Ophthalmology"},{"key":"BFsrep31550_CR34","doi-asserted-by":"publisher","first-page":"1851","DOI":"10.1016\/j.jcrs.2006.06.025","volume":"32","author":"R Ambrosio Jr.","year":"2006","unstructured":"Ambrosio, R. Jr., Alonso, R. S., Luz, A. & Coca Velarde, L. G. Corneal-thickness spatial profile and corneal-volume distribution: tomographic indices to detect keratoconus. J. Cataract Refract. Surg. 32, 1851\u20131859 (2006).","journal-title":"J. Cataract Refract. Surg."},{"key":"BFsrep31550_CR35","doi-asserted-by":"crossref","first-page":"24","DOI":"10.3928\/1081-597X-20030101-05","volume":"19","author":"R Ambrosio Jr.","year":"2003","unstructured":"Ambrosio, R. Jr., Klyce, S. D. & Wilson, S. E. Corneal topographic and pachymetric screening of keratorefractive patients. J. Refract. Surg. 19, 24\u201329 (2003).","journal-title":"J. Refract. Surg."},{"key":"BFsrep31550_CR36","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1097\/ICO.0000000000000408","volume":"34","author":"JA Gomes","year":"2015","unstructured":"Gomes, J. A. et al. Global consensus on keratoconus and ectatic diseases. Cornea 34, 359\u2013369 (2015).","journal-title":"Cornea"},{"key":"BFsrep31550_CR37","doi-asserted-by":"publisher","first-page":"3424","DOI":"10.1167\/iovs.09-4960","volume":"51","author":"J Buhren","year":"2010","unstructured":"Buhren, J., Kook, D., Yoon, G. & Kohnen, T. Detection of subclinical keratoconus by using corneal anterior and posterior surface aberrations and thickness spatial profiles. Invest Ophthalmol. Vis. Sci. 51, 3424\u20133432 (2010).","journal-title":"Invest Ophthalmol. Vis. Sci."},{"key":"BFsrep31550_CR38","doi-asserted-by":"publisher","first-page":"1534","DOI":"10.1016\/j.ophtha.2008.02.020","volume":"115","author":"U De Sanctis","year":"2008","unstructured":"De Sanctis, U. et al. Sensitivity and specificity of posterior corneal elevation measured by Pentacam in discriminating keratoconus\/subclinical keratoconus. Ophthalmology 115, 1534\u20131539 (2008).","journal-title":"Ophthalmology"},{"key":"BFsrep31550_CR39","doi-asserted-by":"publisher","first-page":"2290","DOI":"10.1016\/j.jcrs.2004.05.021","volume":"30","author":"PS Tsai","year":"2004","unstructured":"Tsai, P. S., Dowidar, A., Naseri, A. & McLeod, S. D. Predicting time to refractive stability after discontinuation of rigid contact lens wear before refractive surgery. J. Cataract Refract. Surg. 30, 2290\u20132294 (2004).","journal-title":"J. Cataract Refract. Surg."},{"key":"BFsrep31550_CR40","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1016\/j.clae.2008.02.001","volume":"31","author":"H Hashemi","year":"2008","unstructured":"Hashemi, H., Firoozabadi, M. R., Mehravaran, S. & Gorouhi, F. Corneal stability after discontinued soft contact lens wear. Cont. Lens Anterior. Eye 31, 122\u2013125 (2008).","journal-title":"Cont. Lens Anterior. Eye"},{"key":"BFsrep31550_CR41","unstructured":"Copeland, R. A., Afshari, N. A. & Dohlman, C. H. Copeland and Afshari\u2019s principles and practice of cornea.(Jaypee Brothers Medical Publishers, 2013)."},{"key":"BFsrep31550_CR42","first-page":"2537","volume":"39","author":"K Zadnik","year":"1998","unstructured":"Zadnik, K. et al. Baseline findings in the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study. Invest Ophthalmol. Vis. Sci. 39, 2537\u20132546 (1998).","journal-title":"Invest Ophthalmol. Vis. Sci."},{"key":"BFsrep31550_CR43","doi-asserted-by":"publisher","first-page":"845","DOI":"10.1136\/bjo.2008.147371","volume":"93","author":"SD Klyce","year":"2009","unstructured":"Klyce, S. D. Chasing the suspect: keratoconus. Br. J. Ophthalmol. 93, 845\u2013847 (2009).","journal-title":"Br. J. Ophthalmol."},{"key":"BFsrep31550_CR44","doi-asserted-by":"publisher","first-page":"S15","DOI":"10.3928\/15428877-20110627-02","volume":"42","author":"J Wang","year":"2011","unstructured":"Wang, J. et al. Ultra-high resolution optical coherence tomography for imaging the anterior segment of the eye. Ophthalmic Surg. Lasers Imaging 42 Suppl, S15\u2013S27 (2011).","journal-title":"Ophthalmic Surg. Lasers Imaging"},{"key":"BFsrep31550_CR45","doi-asserted-by":"publisher","first-page":"691","DOI":"10.1167\/iovs.12-10263","volume":"54","author":"Y Lian","year":"2013","unstructured":"Lian, Y. et al. Vertical and horizontal thickness profiles of the corneal epithelium and Bowman\u2019s layer after orthokeratology. Invest Ophthalmol. Vis. Sci. 54, 691\u2013696 (2013).","journal-title":"Invest Ophthalmol. Vis. Sci."},{"key":"BFsrep31550_CR46","doi-asserted-by":"publisher","first-page":"1036","DOI":"10.1097\/ICO.0b013e31823f8d56","volume":"31","author":"C Du","year":"2012","unstructured":"Du, C., Wang, J., Cui, L., Shen, M. & Yuan, Y. Vertical and horizontal corneal epithelial thickness profiles determined by ultrahigh resolution optical coherence tomography. Cornea 31, 1036\u20131043 (2012).","journal-title":"Cornea"},{"key":"BFsrep31550_CR47","doi-asserted-by":"publisher","first-page":"1524","DOI":"10.1364\/BOE.2.001524","volume":"2","author":"F Larocca","year":"2011","unstructured":"Larocca, F. et al. Robust automatic segmentation of corneal layer boundaries in SDOCT images using graph theory and dynamic programming. Biomed. Opt. Express 2, 1524\u20131538 (2011).","journal-title":"Biomed. Opt. Express"},{"key":"BFsrep31550_CR48","doi-asserted-by":"publisher","first-page":"21293","DOI":"10.1364\/OE.18.021293","volume":"18","author":"Q Yang","year":"2010","unstructured":"Yang, Q. et al. Automated layer segmentation of macular OCT images using dual-scale gradient information. Opt. Express 18, 21293\u201321307 (2010).","journal-title":"Opt. Express"},{"key":"BFsrep31550_CR49","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1097\/ICL.0000000000000017","volume":"40","author":"M Shen","year":"2014","unstructured":"Shen, M. et al. Agreement of corneal epithelial profiles produced by automated segmentation of SD-OCT images having different optical resolutions. Eye Contact Lens 40, 99\u2013105 (2014).","journal-title":"Eye Contact Lens"},{"key":"BFsrep31550_CR50","doi-asserted-by":"publisher","first-page":"8923","DOI":"10.1364\/OE.18.008923","volume":"18","author":"M Zhao","year":"2010","unstructured":"Zhao, M., Kuo, A. N. & Izatt, J. A. 3D refraction correction and extraction of clinical parameters from spectral domain optical coherence tomography of the cornea. Opt. Express 18, 8923\u20138936 (2010).","journal-title":"Opt. Express"},{"key":"BFsrep31550_CR51","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1111\/j.1475-1313.1987.tb01011.x","volume":"7","author":"RA Clement","year":"1987","unstructured":"Clement, R. A., Dunne, M. C. & Barnes, D. A. A method for raytracing through schematic eyes with off-axis components. Ophthalmic Physiol Opt. 7, 149\u2013152 (1987).","journal-title":"Ophthalmic Physiol Opt."},{"key":"BFsrep31550_CR52","doi-asserted-by":"publisher","first-page":"397","DOI":"10.1364\/OE.10.000397","volume":"10","author":"V Westphal","year":"2002","unstructured":"Westphal, V., Rollins, A., Radhakrishnan, S. & Izatt, J. Correction of geometric and refractive image distortions in optical coherence tomography applying Fermat\u2019s principle. Opt. Express 10, 397\u2013404 (2002).","journal-title":"Opt. Express"},{"key":"BFsrep31550_CR53","doi-asserted-by":"publisher","first-page":"1277","DOI":"10.1088\/0031-9155\/49\/7\/015","volume":"49","author":"A Podoleanu","year":"2004","unstructured":"Podoleanu, A., Charalambous, I., Plesea, L., Dogariu, A. & Rosen, R. Correction of distortions in optical coherence tomography imaging of the eye. Phys. Med. Biol. 49, 1277\u20131294 (2004).","journal-title":"Phys. Med. Biol."},{"key":"BFsrep31550_CR54","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1364\/OL.29.000083","volume":"29","author":"RC Lin","year":"2004","unstructured":"Lin, R. C., Shure, M. A., Rollins, A. M., Izatt, J. A. & Huang, D. Group index of the human cornea at 1.3-microm wavelength obtained in vitro by optical coherence domain reflectometry. Opt. Lett. 29, 83\u201385 (2004).","journal-title":"Opt. Lett."},{"key":"BFsrep31550_CR55","doi-asserted-by":"publisher","first-page":"188","DOI":"10.1136\/bmj.309.6948.188","volume":"309","author":"DG Altman","year":"1994","unstructured":"Altman, D. G. & Bland, J. M. Diagnostic tests 3: receiver operating characteristic plots. BMJ 309, 188 (1994).","journal-title":"BMJ"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/srep31550","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/srep31550.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/srep31550.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,4]],"date-time":"2023-01-04T20:22:03Z","timestamp":1672863723000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/srep31550"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,8,11]]},"references-count":55,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2016,11,14]]}},"alternative-id":["BFsrep31550"],"URL":"https:\/\/doi.org\/10.1038\/srep31550","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,8,11]]},"assertion":[{"value":"5 February 2016","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 July 2016","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 August 2016","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing financial interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"31550"}}