{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,3]],"date-time":"2026-03-03T15:59:04Z","timestamp":1772553544668,"version":"3.50.1"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2017,4,5]],"date-time":"2017-04-05T00:00:00Z","timestamp":1491350400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2017,4,5]],"date-time":"2017-04-05T00:00:00Z","timestamp":1491350400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>A sensor was tested <jats:italic>subdural<\/jats:italic> and <jats:italic>in vitro,<\/jats:italic> simulating a supine infant with a ventricular-peritoneal shunt and controlled occlusions. The variable MEMS capacitive device is able to detect and forecast blockages, similar to early detection procedures in cancer patients. For example, with gradual occlusion development over a year, the method forecasts a danger over one month ahead of blockage. The method also distinguishes between ventricular and peritoneal occlusions. Because the sensor provides quantitative data on the dynamics of the cerebrospinal fluid, it can help test new therapies and work toward understanding hydrocephalus as well as idiopathic normal pressure hydrocephalus. The sensor appears to be a substantial advance in treating brain injuries treated with shunts and has the potential to bring significant impact in a clinical setting.<\/jats:p>","DOI":"10.1038\/srep46039","type":"journal-article","created":{"date-parts":[[2017,4,5]],"date-time":"2017-04-05T10:08:14Z","timestamp":1491386894000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Evidence of an application of a variable MEMS capacitive sensor for detecting shunt occlusions"],"prefix":"10.1038","volume":"7","author":[{"given":"David J.","family":"Apigo","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philip L.","family":"Bartholomew","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas","family":"Russell","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alokik","family":"Kanwal","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Reginald C.","family":"Farrow","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gordon A.","family":"Thomas","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2017,4,5]]},"reference":[{"key":"BFsrep46039_CR1","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1016\/j.sna.2016.10.030","volume":"251","author":"DJ Apigo","year":"2016","unstructured":"Apigo, D. J. et al. An Angstrom-Sensitive, Differential MEMS Capacitor for Monitoring the Milliliter Dynamics of Fluids. Sensors and Actuators A: Physical 251, 234\u2013240 (2016).","journal-title":"Sensors and Actuators A: Physical"},{"key":"BFsrep46039_CR2","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1016\/j.sna.2015.08.023","volume":"234","author":"R Raj","year":"2015","unstructured":"Raj, R. et al. Demonstration that a New Flow Sensor Can Operate in the Clinical Range for Cerebrospinal Fluid Flow. Sensors and Actuators A: Physical 234, 223\u2013231 (2015).","journal-title":"Sensors and Actuators A: Physical"},{"key":"BFsrep46039_CR3","doi-asserted-by":"publisher","first-page":"E707","DOI":"10.1016\/j.wneu.2013.09.002","volume":"82","author":"JT Goodrich","year":"2014","unstructured":"Goodrich, J. T. 1500 Years of Hydrocephalus Treatment - How Little it Has Changed. World Neurosurgery 82, E707\u2013E708 (2014).","journal-title":"World Neurosurgery"},{"key":"BFsrep46039_CR4","doi-asserted-by":"publisher","first-page":"454","DOI":"10.1016\/j.ejpn.2013.04.001","volume":"17","author":"H Xu","year":"2013","unstructured":"Xu, H. et al. Programmable Shunt Valves for the Treatment of Hydrocephalus: a Systematic Review. European Journal of Pediatric Neurology 17, 454\u2013461 (2013).","journal-title":"European Journal of Pediatric Neurology"},{"key":"BFsrep46039_CR5","doi-asserted-by":"publisher","first-page":"729","DOI":"10.3171\/jns.1973.38.6.0729","volume":"38","author":"HD Portnoy","year":"1973","unstructured":"Portnoy, H. D., Schulte, R. R., Fox, J. L., Croissant, P. D. & Tripp, L. Anti-Siphon and Reversible Occlusion Valves for Shunting in Hydrocephalus and Preventing Post-Shunt Subdural Hematomas. Journal of Neurosurgery 38, 729\u2013738 (1973).","journal-title":"Journal of Neurosurgery"},{"key":"BFsrep46039_CR6","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1038\/ncpneuro0237","volume":"2","author":"GL Gallia","year":"2006","unstructured":"Gallia, G. L., Rigamonti, D. & Williams, M. A. The Diagnosis and Treatment of Idiopathic Normal Pressure Hydrocephalus. Nature Clinical Practice Neurology 2, 375\u2013381 (2006).","journal-title":"Nature Clinical Practice Neurology"},{"key":"BFsrep46039_CR7","doi-asserted-by":"crossref","unstructured":"Aoki, Y. et al. Noninvasive Prediction of Shunt Operation Outcome in Idiopathic Normal Pressure Hydrocephalus. Scientific Reports 5 (2015).","DOI":"10.1038\/srep07775"},{"key":"BFsrep46039_CR8","doi-asserted-by":"publisher","first-page":"38","DOI":"10.4103\/2152-7806.109197","volume":"4","author":"B Lutz","year":"2013","unstructured":"Lutz, B., Venkataraman, P. & Browd, S. New and Improved Ways to Treat Hydrocephalus: Pursuit of a Smart Shunt. Surgical Neurology International 4, 38 (2013).","journal-title":"Surgical Neurology International"},{"key":"BFsrep46039_CR9","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1097\/00006123-199802000-00064","volume":"42","author":"MR Del Bigio","year":"1998","unstructured":"Del Bigio, M. R. Biological Reactions to Cerebrospinal Fluid Shunt Devices: A Review of the Cellular Pathology. Neurosurgery 42, 319\u2013325 (1998).","journal-title":"Neurosurgery"},{"key":"BFsrep46039_CR10","unstructured":"Kandel, E. R., Schwartz, J. H. & Jessell, T. M. Principles of Neural Science(McGraw-Hill, Health Professions Division, New York, NY, 2000)."},{"key":"BFsrep46039_CR11","doi-asserted-by":"publisher","first-page":"1573","DOI":"10.1007\/s00381-006-0194-4","volume":"22","author":"C Di Rocco","year":"2006","unstructured":"Di Rocco, C., Massimi, L. & Tamburrini, G. Shunts vs Endoscopic Third Ventriculostomy in Infants: Are There Different Types and\/or Rates of Complications? Childs Nerv Syst 22, 1573\u20131589 (2006).","journal-title":"Childs Nerv Syst"},{"key":"BFsrep46039_CR12","doi-asserted-by":"publisher","first-page":"643","DOI":"10.1136\/jnnp.64.5.643","volume":"64","author":"HL Brydon","year":"1998","unstructured":"Brydon, H. L. et al. Protein Adsorption to Hydrocephalus Shunt Catheters: CSF Protein Adsorption. Journal of Neurology, Neurosurgery and Psychiatry 64, 643\u2013647 (1998).","journal-title":"Journal of Neurology, Neurosurgery and Psychiatry"},{"key":"BFsrep46039_CR13","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1136\/bmj.2.5861.289","volume":"2","author":"JS Robertson","year":"1973","unstructured":"Robertson, J. S., Maraqa, M. & Jennett, B. Ventriculoperitoneal Shunting for Hydrocephalus. British Medical Journal 2, 289 (1973).","journal-title":"British Medical Journal"},{"key":"BFsrep46039_CR14","doi-asserted-by":"publisher","first-page":"525","DOI":"10.3171\/jns.1967.27.6.0525","volume":"27","author":"RH Ames","year":"1967","unstructured":"Ames, R. H. Ventriculo-Peritoneal Shunts in the Management of Hydrocephalus. Journal of Neurosurgery 27, 525 (1967).","journal-title":"Journal of Neurosurgery"},{"key":"BFsrep46039_CR15","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1016\/j.cpem.2008.03.001","volume":"9","author":"P Lee","year":"2008","unstructured":"Lee, P. & DiPatri Jr, A. J. Evaluation of Suspected Cerebrospinal Fluid Shunt Complications in Children. Clinical Pediatric Emergency Medicine 9, 76\u201382 (2008).","journal-title":"Clinical Pediatric Emergency Medicine"},{"key":"BFsrep46039_CR16","first-page":"5","volume":"11","author":"JJ Stone","year":"2013","unstructured":"Stone, J. J., Walker, C. T., Jacobson, M., Phillips, V. & Silberstein, H. J. Revision Rate of Pediatric Ventriculoperitoneal Shunts After 15 Years: Clinical Article. Journal of Neurosurgery: Pediatrics 11, 5 (2013).","journal-title":"Journal of Neurosurgery: Pediatrics"},{"key":"BFsrep46039_CR17","doi-asserted-by":"publisher","first-page":"31","DOI":"10.3171\/jns.2000.92.1.0031","volume":"92","author":"S Tuli","year":"2000","unstructured":"Tuli, S., Drake, J., Lawless, J., Wigg, M. & Lamberti-Pasculli, M. Risk Factors for Repeated Cerebrospinal Shunt Failures in Pediatric Patients with Hydrocephalus. Journal of Neurosurgery 92, 31\u201338 (2000).","journal-title":"Journal of Neurosurgery"},{"key":"BFsrep46039_CR18","first-page":"156","volume":"4","author":"TD Simon","year":"2009","unstructured":"Simon, T. D. et al. Infection Rates Following Initial Cerebrospinal Fluid Shunt Placement Across Pediatric Hospitals in the United States. Clinical Article. Journal Of Neurosurgery . Pediatrics 4, 156\u2013165 (2009).","journal-title":"Pediatrics"},{"key":"BFsrep46039_CR19","doi-asserted-by":"crossref","unstructured":"Arbour, R. Intracranial Hypertension Monitoring and Nursing Assessment. Critical Care Nurse 24 (2004).","DOI":"10.4037\/ccn2004.24.5.19"},{"key":"BFsrep46039_CR20","unstructured":"Irani, D. N. Cerebrospinal Fluid in Clinical Practice(Elsevier Health Sciences, Philadelphia, PA, 2009)."},{"key":"BFsrep46039_CR21","doi-asserted-by":"publisher","first-page":"720","DOI":"10.1097\/00005053-193506000-00059","volume":"81","author":"HH Merritt","year":"1935","unstructured":"Merritt, H. H. & Fremont-Smith, F. The Cerebrospinal Fluid. The Journal of Nervous and Mental Disease 81, 720 (1935).","journal-title":"The Journal of Nervous and Mental Disease"},{"key":"BFsrep46039_CR22","doi-asserted-by":"publisher","first-page":"440","DOI":"10.1001\/archneurpsyc.1925.02200160007002","volume":"14","author":"JB Ayer","year":"1925","unstructured":"Ayer, J. B. Cerebrospinal Fluid Pressure From the Clinical Point of View. Archives of Neurology and Psychiatry 14, 440 (1925).","journal-title":"Archives of Neurology and Psychiatry"},{"key":"BFsrep46039_CR23","doi-asserted-by":"publisher","first-page":"6027","DOI":"10.1109\/JSEN.2015.2451655","volume":"15","author":"TM Clark","year":"2015","unstructured":"Clark, T. M., Malpas, S. C., McCormick, D., Budgett, D. M. & Heppner, P. Implantable Multi-Modal Sensor to Improve Outcomes in Hydrocephalus Management. IEEE Sensors Journal 15, 6027\u20136035 (2015).","journal-title":"IEEE Sensors Journal"},{"key":"BFsrep46039_CR24","unstructured":"Oosterbroek, R., Lammerink, T., Berenschot, J., Berg, v.d.A. & Elwenspoek, M. In Internatoinal Conference on Solid-State Sensors and Actuators, Transducers \u201897 (1997)."},{"key":"BFsrep46039_CR25","unstructured":"Granger, R. A. Fluid Mechanics(Dover Publications, Inc., New York, NY, 1995)."},{"key":"BFsrep46039_CR26","doi-asserted-by":"crossref","unstructured":"Chen, L. Y. et al. Continuous Wireless Pressure Monitoring and Mapping with Ultra-Small Passive Sensors for Health Monitoring and Critical Care. Nature Communications 5 (2014).","DOI":"10.1038\/ncomms6028"},{"key":"BFsrep46039_CR27","unstructured":"Purcell, E. M. Electricity and Magnetism(McGraw-Hill, New York, NY, 1985)."},{"key":"BFsrep46039_CR28","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1017\/S0022112005005707","volume":"539","author":"A Smillie","year":"2005","unstructured":"Smillie, A., Sobey, I. & Molnar, Z. A Hydroelastic Model of Hydrocephalus. Journal of Fluid Mechanics 539, 417\u2013443 (2005).","journal-title":"Journal of Fluid Mechanics"},{"key":"BFsrep46039_CR29","unstructured":"Drake, J. M. & Sainte-Rose, C. The Shunt Book(Wiley-Blackwell Science, Hoboken, NJ, 1995)."},{"key":"BFsrep46039_CR30","doi-asserted-by":"publisher","first-page":"650","DOI":"10.3171\/jns.1982.56.5.0650","volume":"56","author":"RK Narayan","year":"1982","unstructured":"Narayan, R. K. et al. Intracranial Pressure: to Monitor or Not to Monitor? A Review of Our Experience with Severe Head Injury. Journal of Neurosurgery 56, 650\u2013659 (1982).","journal-title":"Journal of Neurosurgery"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/srep46039.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/srep46039","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/www.nature.com\/doifinder\/10.1038\/srep46039","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"https:\/\/www.nature.com\/articles\/srep46039.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,23]],"date-time":"2022-12-23T23:31:20Z","timestamp":1671838280000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/srep46039"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,4,5]]},"references-count":30,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2017,8,24]]}},"alternative-id":["BFsrep46039"],"URL":"https:\/\/doi.org\/10.1038\/srep46039","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,4,5]]},"assertion":[{"value":"3 November 2016","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 March 2017","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 April 2017","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing financial interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"46039"}}