{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,20]],"date-time":"2026-10-20T11:42:03Z","timestamp":1792496523690,"version":"4.5.0"},"reference-count":80,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T00:00:00Z","timestamp":1789603200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,10,20]],"date-time":"2026-10-20T00:00:00Z","timestamp":1792454400000},"content-version":"vor","delay-in-days":33,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Nat Commun"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Cuffless blood pressure monitoring is essential for continuous cardiovascular assessment. Current wearable approaches rely on pulse-echo ultrasound patches that track pulsating arterial diameters. However, multi-element designs and precise alignment complicate their applicability as a fully wearable solution. We overcome these challenges by using a highly miniaturized silicon-photonics acoustic detector and optoacoustic excitation to generate ultrasound waves inside the artery. The superior contrast in these optoacoustic signals and the detector\u2019s semi-isotropic sensitivity enable robust artery diameter monitoring with a single detection element, achieving high tolerance to translation and rotation. The detector\u2019s high sensitivity, achieved despite its small size, enables measuring optoacoustic signals from the radial artery with a high contrast at 100\u2009Hz, capturing the features of the blood pressure waveform. Here, we show that the device\u2019s agreement with a reference cuff-based blood pressure monitor highlights the potential of silicon-photonics optoacoustic sensing as a practical solution for continuous, cuffless monitoring in daily life.<\/jats:p>","DOI":"10.1038\/s41467-026-77580-3","type":"journal-article","created":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T17:04:42Z","timestamp":1789664682000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Silicon-photonics optoacoustic sensor for fully wearable blood pressure monitoring"],"prefix":"10.1038","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-2875-2761","authenticated-orcid":false,"given":"Gil","family":"Gelbert","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-8784-0675","authenticated-orcid":false,"given":"Ron","family":"Moisseev","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4503-6990","authenticated-orcid":false,"given":"Yoav","family":"Hazan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tamar","family":"Harary","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-2650-6153","authenticated-orcid":false,"given":"Daniel H.","family":"Lange","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8077-7773","authenticated-orcid":false,"given":"Amir","family":"Rosenthal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,9,17]]},"reference":[{"key":"77580_CR1","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1038\/s41746-023-00835-6","volume":"6","author":"L Zhao","year":"2023","unstructured":"Zhao, L. et al. Emerging sensing and modeling technologies for wearable and cuffless blood pressure monitoring. npj Digit. Med. 6, 93 (2023).","journal-title":"npj Digit. Med."},{"key":"77580_CR2","doi-asserted-by":"publisher","first-page":"1399","DOI":"10.1109\/TIM.2018.2800539","volume":"67","author":"PM Nabeel","year":"2018","unstructured":"Nabeel, P. M., Karthik, S., Joseph, J. & Sivaprakasam, M. Arterial blood pressure estimation from local pulse wave velocity using dual-element photoplethysmograph probe. IEEE Trans. Instrum. Meas. 67, 1399\u20131408 (2018).","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"77580_CR3","doi-asserted-by":"publisher","DOI":"10.1007\/s11082-020-02667-0","volume":"53","author":"S Yang","year":"2021","unstructured":"Yang, S., Zhang, Y., Cho, S.-Y., Correia, R. & Morgan, S. P. Non-invasive cuff-less blood pressure estimation using a hybrid deep learning model. Opt. Quantum Electron. 53, 93 (2021).","journal-title":"Opt. Quantum Electron."},{"key":"77580_CR4","doi-asserted-by":"publisher","first-page":"692","DOI":"10.3390\/bioengineering9110692","volume":"9","author":"N Ibtehaz","year":"2022","unstructured":"Ibtehaz, N. et al. PPG2ABP: translating photoplethysmogram (PPG) signals to arterial blood pressure (ABP) waveforms. Bioengineering 9, 692 (2022).","journal-title":"Bioengineering"},{"key":"77580_CR5","doi-asserted-by":"publisher","first-page":"104040","DOI":"10.1016\/j.bspc.2022.104040","volume":"79","author":"S Sun","year":"2023","unstructured":"Sun, S. et al. Systolic blood pressure estimation using ECG and PPG in patients undergoing surgery. Biomed. Signal Process. Control 79, 104040 (2023).","journal-title":"Biomed. Signal Process. Control"},{"key":"77580_CR6","doi-asserted-by":"publisher","first-page":"85459","DOI":"10.1109\/ACCESS.2022.3195857","volume":"10","author":"C-T Yen","year":"2022","unstructured":"Yen, C.-T., Chang, S.-N. & Liao, C.-H. Estimation of beat-by-beat blood pressure and heart rate from ECG and PPG using a fine-tuned deep CNN model. IEEE Access 10, 85459\u201385469 (2022).","journal-title":"IEEE Access"},{"key":"77580_CR7","doi-asserted-by":"publisher","first-page":"864","DOI":"10.1038\/s41565-022-01145-w","volume":"17","author":"D Kireev","year":"2022","unstructured":"Kireev, D. et al. Continuous cuffless monitoring of arterial blood pressure via graphene bioimpedance tattoos. Nat. Nanotechnol. 17, 864\u2013870 (2022).","journal-title":"Nat. Nanotechnol."},{"key":"77580_CR8","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1007\/s11818-013-0617-x","volume":"17","author":"A Hennig","year":"2013","unstructured":"Hennig, A. & Patzak, A. Continuous blood pressure measurement using pulse transit time. Somnologie 17, 104\u2013110 (2013).","journal-title":"Somnologie"},{"key":"77580_CR9","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1109\/RBME.2019.2931587","volume":"13","author":"PM Nabeel","year":"2020","unstructured":"Nabeel, P. M., Kiran, V. R., Joseph, J., Abhidev, V. V. & Sivaprakasam, M. Local pulse wave velocity: theory, methods, advancements, and clinical applications. IEEE Rev. Biomed. Eng. 13, 74\u2013112 (2020).","journal-title":"IEEE Rev. Biomed. Eng."},{"key":"77580_CR10","doi-asserted-by":"publisher","unstructured":"Poojitha, U. P. et al. Blood Pressure Estimation using Arterial Diameter: Exploring Different Machine Learning Methods. in 2020 IEEE International Symposium on Medical Measurements and Applications (MeMeA) 1\u20136 https:\/\/doi.org\/10.1109\/MeMeA49120.2020.9137234 (IEEE, 2020).","DOI":"10.1109\/MeMeA49120.2020.9137234"},{"key":"77580_CR11","doi-asserted-by":"publisher","unstructured":"Min, S. et al. Wearable blood pressure sensors for cardiovascular monitoring and machine learning algorithms for blood pressure estimation. Nat. Rev. Cardiol. https:\/\/doi.org\/10.1038\/s41569-025-01127-0 (2025).","DOI":"10.1038\/s41569-025-01127-0"},{"key":"77580_CR12","doi-asserted-by":"publisher","first-page":"1653","DOI":"10.1088\/0967-3334\/32\/10\/012","volume":"32","author":"J Vappou","year":"2011","unstructured":"Vappou, J., Luo, J., Okajima, K., Di Tullio, M. & Konofagou, E. E. Non-invasive measurement of local pulse pressure by pulse wave-based ultrasound manometry (PWUM). Physiol. Meas. 32, 1653\u20131662 (2011).","journal-title":"Physiol. Meas."},{"key":"77580_CR13","doi-asserted-by":"publisher","first-page":"788","DOI":"10.1016\/j.ultrasmedbio.2011.01.020","volume":"37","author":"BWAMM Beulen","year":"2011","unstructured":"Beulen, B. W. A. M. M. et al. Toward noninvasive blood pressure assessment in arteries by using ultrasound. Ultrasound Med. Biol. 37, 788\u2013797 (2011).","journal-title":"Ultrasound Med. Biol."},{"key":"77580_CR14","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1016\/j.ultrasmedbio.2003.10.014","volume":"30","author":"JM Meinders","year":"2004","unstructured":"Meinders, J. M. & Hoeks, A. P. G. Simultaneous assessment of diameter and pressure waveforms in the carotid artery. Ultrasound Med. Biol. 30, 147\u2013154 (2004).","journal-title":"Ultrasound Med. Biol."},{"key":"77580_CR15","doi-asserted-by":"publisher","first-page":"448","DOI":"10.1038\/s41587-023-01800-0","volume":"42","author":"M Lin","year":"2024","unstructured":"Lin, M. et al. A fully integrated wearable ultrasound system to monitor deep tissues in moving subjects. Nat. Biotechnol. 42, 448\u2013457 (2024).","journal-title":"Nat. Biotechnol."},{"key":"77580_CR16","doi-asserted-by":"publisher","first-page":"517","DOI":"10.1126\/science.abo2542","volume":"377","author":"C Wang","year":"2022","unstructured":"Wang, C. et al. Bioadhesive ultrasound for long-term continuous imaging of diverse organs. Science 377, 517\u2013523 (2022).","journal-title":"Science"},{"key":"77580_CR17","doi-asserted-by":"publisher","first-page":"810","DOI":"10.1038\/s41586-024-07381-5","volume":"629","author":"S Zhou","year":"2024","unstructured":"Zhou, S. et al. Transcranial volumetric imaging using a conformal ultrasound patch. Nature 629, 810\u2013818 (2024).","journal-title":"Nature"},{"key":"77580_CR18","doi-asserted-by":"publisher","first-page":"667","DOI":"10.1038\/s41586-022-05498-z","volume":"613","author":"H Hu","year":"2023","unstructured":"Hu, H. et al. A wearable cardiac ultrasound imager. Nature 613, 667\u2013675 (2023).","journal-title":"Nature"},{"key":"77580_CR19","doi-asserted-by":"publisher","first-page":"749","DOI":"10.1038\/s41551-021-00763-4","volume":"5","author":"C Wang","year":"2021","unstructured":"Wang, C. et al. Continuous monitoring of deep-tissue haemodynamics with stretchable ultrasonic phased arrays. Nat. Biomed. Eng. 5, 749\u2013758 (2021).","journal-title":"Nat. Biomed. Eng."},{"key":"77580_CR20","doi-asserted-by":"publisher","first-page":"687","DOI":"10.1038\/s41551-018-0287-x","volume":"2","author":"C Wang","year":"2018","unstructured":"Wang, C. et al. Monitoring of the central blood pressure waveform via a conformal ultrasonic device. Nat. Biomed. Eng. 2, 687\u2013695 (2018).","journal-title":"Nat. Biomed. Eng."},{"key":"77580_CR21","doi-asserted-by":"publisher","first-page":"865","DOI":"10.1038\/s41551-024-01279-3","volume":"9","author":"S Zhou","year":"2024","unstructured":"Zhou, S. et al. Clinical validation of a wearable ultrasound sensor of blood pressure. Nat. Biomed. Eng. 9, 865\u2013881 (2024).","journal-title":"Nat. Biomed. Eng."},{"key":"77580_CR22","doi-asserted-by":"publisher","first-page":"e2019339118","DOI":"10.1073\/pnas.2019339118","volume":"118","author":"JM Rothberg","year":"2021","unstructured":"Rothberg, J. M. et al. Ultrasound-on-chip platform for medical imaging, analysis, and collective intelligence. Proc. Natl. Acad. Sci. USA 118, e2019339118 (2021).","journal-title":"Proc. Natl. Acad. Sci. USA"},{"key":"77580_CR23","doi-asserted-by":"publisher","first-page":"4745","DOI":"10.1088\/0031-9155\/49\/20\/006","volume":"49","author":"RGM Kolkman","year":"2004","unstructured":"Kolkman, R. G. M. et al. Photoacoustic determination of blood vessel diameter. Phys. Med. Biol. 49, 4745\u20134756 (2004).","journal-title":"Phys. Med. Biol."},{"key":"77580_CR24","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1007\/s10103-006-0384-z","volume":"21","author":"RGM Kolkman","year":"2006","unstructured":"Kolkman, R. G. M., Steenbergen, W. & Van Leeuwen, T. G. In vivo photoacoustic imaging of blood vessels with a pulsed laser diode. Lasers Med Sci. 21, 134\u2013139 (2006).","journal-title":"Lasers Med Sci."},{"key":"77580_CR25","first-page":"907","volume":"9","author":"Z Or","year":"2022","unstructured":"Or, Z., Levi, A. R., Hazan, Y. & Rosenthal, A. Hand-held optoacoustic system for the localization of mid-depth. Blood Vessels Photonics 9, 907 (2022).","journal-title":"Blood Vessels Photonics"},{"key":"77580_CR26","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-022-35455-3","volume":"13","author":"X Gao","year":"2022","unstructured":"Gao, X. et al. A photoacoustic patch for three-dimensional imaging of hemoglobin and core temperature. Nat. Commun. 13, 7757 (2022).","journal-title":"Nat. Commun."},{"key":"77580_CR27","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-023-40181-5","volume":"14","author":"H Jin","year":"2023","unstructured":"Jin, H. et al. A flexible optoacoustic blood \u2018stethoscope\u2019 for noninvasive multiparametric cardiovascular monitoring. Nat. Commun. 14, 4692 (2023).","journal-title":"Nat. Commun."},{"key":"77580_CR28","doi-asserted-by":"publisher","unstructured":"Panchawagh, H. V., Agrawal, S., Soukup, B. H. & Djordjev, K. Compact Photoacoustic Imaging Module for Wearable Health Monitoring Devices. in 2025 IEEE International Ultrasonics Symposium (IUS) 1\u20134 https:\/\/doi.org\/10.1109\/IUS62464.2025.11201517 (IEEE, 2025).","DOI":"10.1109\/IUS62464.2025.11201517"},{"key":"77580_CR29","doi-asserted-by":"publisher","first-page":"2677","DOI":"10.1364\/OL.44.002677","volume":"44","author":"L Riob\u00f3","year":"2019","unstructured":"Riob\u00f3, L. et al. Noise reduction in resonator-based ultrasound sensors by using a CW laser and phase detection. Opt. Lett. 44, 2677 (2019).","journal-title":"Opt. Lett."},{"key":"77580_CR30","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-022-29179-7","volume":"13","author":"Y Hazan","year":"2022","unstructured":"Hazan, Y., Levi, A., Nagli, M. & Rosenthal, A. Silicon-photonics acoustic detector for optoacoustic micro-tomography. Nat. Commun. 13, 1488 (2022).","journal-title":"Nat. Commun."},{"key":"77580_CR31","doi-asserted-by":"publisher","first-page":"056605","DOI":"10.1103\/PhysRevE.67.056605","volume":"67","author":"M Xu","year":"2003","unstructured":"Xu, M. & Wang, L. V. Analytic explanation of spatial resolution related to bandwidth and detector aperture size in thermoacoustic or photoacoustic reconstruction. Phys. Rev. E 67, 056605 (2003).","journal-title":"Phys. Rev. E"},{"key":"77580_CR32","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1016\/0021-9290(80)90191-8","volume":"13","author":"K Hayashi","year":"1980","unstructured":"Hayashi, K., Handa, H., Nagasawa, S., Okumura, A. & Moritake, K. Stiffness and elastic behavior of human intracranial and extracranial arteries. J. Biomech. 13, 175\u2013184 (1980).","journal-title":"J. Biomech."},{"key":"77580_CR33","doi-asserted-by":"publisher","first-page":"1763","DOI":"10.1213\/ANE.0b013e3181bbd416","volume":"109","author":"M Brzezinski","year":"2009","unstructured":"Brzezinski, M., Luisetti, T. & London, M. J. Radial artery cannulation: a comprehensive review of recent anatomic and physiologic investigations. Anesth. Analg. 109, 1763\u20131781 (2009).","journal-title":"Anesth. Analg."},{"key":"77580_CR34","unstructured":"Nasr, A. Y. et al. The radial artery and its variations: anatomical study and clinical implications. Folia Morphol. 71, 252\u201362 (2012)."},{"key":"77580_CR35","doi-asserted-by":"publisher","first-page":"1274","DOI":"10.1136\/neurintsurg-2021-018534","volume":"14","author":"W Wahood","year":"2022","unstructured":"Wahood, W., Ghozy, S., Al-Abdulghani, A. & Kallmes, D. F. Radial artery diameter: a comprehensive systematic review of anatomy. J. NeuroIntervent Surg. 14, 1274\u20131278 (2022).","journal-title":"J. NeuroIntervent Surg."},{"key":"77580_CR36","doi-asserted-by":"publisher","first-page":"100527","DOI":"10.1016\/j.pacs.2023.100527","volume":"32","author":"M Nagli","year":"2023","unstructured":"Nagli, M. et al. Silicon photonic acoustic detector (SPADE) using a silicon nitride microring resonator. Photoacoustics 32, 100527 (2023).","journal-title":"Photoacoustics"},{"key":"77580_CR37","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1038\/nrcardio.2013.1","volume":"10","author":"G Parati","year":"2013","unstructured":"Parati, G., Ochoa, J. E., Lombardi, C. & Bilo, G. Assessment and management of blood-pressure variability. Nat. Rev. Cardiol. 10, 143\u2013155 (2013).","journal-title":"Nat. Rev. Cardiol."},{"key":"77580_CR38","doi-asserted-by":"publisher","first-page":"256","DOI":"10.1109\/58.818769","volume":"47","author":"PC Beard","year":"2000","unstructured":"Beard, P. C., Hurrell, A. M. & Mills, T. N. Characterization of a polymer film optical fiber hydrophone for use in the range 1 to 20\u2009MHz: a comparison with PVDF needle and membrane hydrophones. IEEE Trans. Ultrason., Ferroelectr., Frequency Control 47, 256\u2013264 (2000).","journal-title":"IEEE Trans. Ultrason., Ferroelectr., Frequency Control"},{"key":"77580_CR39","first-page":"1037","volume":"14","author":"AM Heagerty","year":"2010","unstructured":"Heagerty, A. M., Heerkens, E. H. & Izzard, A. S. Small artery structure and function in hypertension. J. Cell Mol. Med 14, 1037\u20131043 (2010).","journal-title":"J. Cell Mol. Med"},{"key":"77580_CR40","doi-asserted-by":"publisher","first-page":"605","DOI":"10.1016\/S0008-6363(98)00067-4","volume":"38","author":"BP Imholz","year":"1998","unstructured":"Imholz, B. P., Wieling, W., van Montfrans, G. A. & Wesseling, K. H. Fifteen years experience with finger arterial pressure monitoring: assessment of the technology. Cardiovasc Res 38, 605\u2013616 (1998).","journal-title":"Cardiovasc Res"},{"key":"77580_CR41","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1007\/BF02886824","volume":"10","author":"V Novak","year":"1994","unstructured":"Novak, V., Novak, P. & Schondorf, R. Accuracy of beat-to-beat noninvasive measurement of finger arterial pressure using the finapres: a spectral analysis approach. J. Clin. Monit. Comput 10, 118\u2013126 (1994).","journal-title":"J. Clin. Monit. Comput"},{"key":"77580_CR42","doi-asserted-by":"crossref","unstructured":"Muntner, P. et al. Measurement of blood pressure in humans: a scientific statement from the American Heart Association. Hypertension 73, e35\u2013e66 (2019).","DOI":"10.1161\/HYP.0000000000000087"},{"key":"77580_CR43","doi-asserted-by":"crossref","unstructured":"Celine C., Arnaud L., Andreas K., & Olivier R. Novel short-pulse laser diode source for high-resolution 3D flash lidar. 10332, 103320B (2017).","DOI":"10.1117\/12.2269742"},{"key":"77580_CR44","doi-asserted-by":"publisher","first-page":"e01006","DOI":"10.1002\/lpor.202501006","volume":"19","author":"X Liu","year":"2025","unstructured":"Liu, X. et al. Handheld Embedded Laser-Diode Illumination Optoacoustic System for Real-Time 3D Angiography of Deep Tissues. Laser Photonics Rev. 19, e01006 (2025).","journal-title":"Laser Photonics Rev."},{"key":"77580_CR45","doi-asserted-by":"publisher","unstructured":"Konradl, J. et al. High-power compact VCSEL subsystem as game-changer for photoacoustic medical imaging and sensing. in Vertical-Cavity Surface-Emitting Lasers XXIX (eds Choquette, K. D. & Graham, L. A.) 22 https:\/\/doi.org\/10.1117\/12.3042742 (SPIE, 2025).","DOI":"10.1117\/12.3042742"},{"key":"77580_CR46","doi-asserted-by":"publisher","first-page":"11279","DOI":"10.1364\/OE.22.011279","volume":"22","author":"JA Cox","year":"2014","unstructured":"Cox, J. A., Lentine, A. L., Trotter, D. C. & Starbuck, A. L. Control of integrated micro-resonator wavelength via balanced homodyne locking. Opt. Express 22, 11279 (2014).","journal-title":"Opt. Express"},{"key":"77580_CR47","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-024-46319-3","volume":"15","author":"MH Idjadi","year":"2024","unstructured":"Idjadi, M. H., Kim, K. & Fontaine, N. K. Modulation-free laser stabilization technique using integrated cavity-coupled Mach-Zehnder interferometer. Nat. Commun. 15, 1922 (2024).","journal-title":"Nat. Commun."},{"key":"77580_CR48","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-017-01303-y","volume":"8","author":"MH Idjadi","year":"2017","unstructured":"Idjadi, M. H. & Aflatouni, F. Integrated Pound\u2212Drever\u2212Hall laser stabilization system in silicon. Nat. Commun. 8, 1209 (2017).","journal-title":"Nat. Commun."},{"key":"77580_CR49","doi-asserted-by":"crossref","unstructured":"Deng, H. et al. Single-chip silicon photonic engine for analog optical and microwave signals processing. Nat. Commun. 16, 5087 (2025).","DOI":"10.1038\/s41467-025-60100-0"},{"key":"77580_CR50","doi-asserted-by":"publisher","first-page":"4010","DOI":"10.1364\/OE.381224","volume":"28","author":"M Sinclair","year":"2020","unstructured":"Sinclair, M. et al. 1.4 million Q factor Si3 N4 micro-ring resonator at 780\u2009nm wavelength for chip-scale atomic systems. Opt. Express 28, 4010 (2020).","journal-title":"Opt. Express"},{"key":"77580_CR51","doi-asserted-by":"publisher","first-page":"28844","DOI":"10.1364\/OE.27.028844","volume":"27","author":"Y Hazan","year":"2019","unstructured":"Hazan, Y. & Rosenthal, A. Simultaneous multi-channel ultrasound detection via phase modulated pulse interferometry. Opt. Express 27, 28844 (2019).","journal-title":"Opt. Express"},{"key":"77580_CR52","doi-asserted-by":"publisher","first-page":"1039","DOI":"10.1364\/OL.43.001039","volume":"43","author":"Y Hazan","year":"2018","unstructured":"Hazan, Y. & Rosenthal, A. Passive-demodulation pulse interferometry for ultrasound detection with a high dynamic range. Opt. Lett. 43, 1039 (2018).","journal-title":"Opt. Lett."},{"key":"77580_CR53","doi-asserted-by":"publisher","first-page":"1521","DOI":"10.1007\/s10877-023-01047-9","volume":"37","author":"S-C Wang","year":"2023","unstructured":"Wang, S.-C. et al. Arterial blood pressure waveform in liver transplant surgery possesses variability of morphology reflecting recipients\u2019 acuity and predicting short term outcomes. J. Clin. Monit. Comput 37, 1521\u20131531 (2023).","journal-title":"J. Clin. Monit. Comput"},{"key":"77580_CR54","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1111\/jch.12574","volume":"17","author":"RR Townsend","year":"2015","unstructured":"Townsend, R. R. et al. Clinical use of pulse wave analysis: proceedings from a symposium sponsored by North American Artery. J. Clin. Hypertension 17, 503\u2013513 (2015).","journal-title":"J. Clin. Hypertension"},{"key":"77580_CR55","doi-asserted-by":"publisher","first-page":"2922","DOI":"10.3390\/app9142922","volume":"9","author":"S-H Liu","year":"2019","unstructured":"Liu, S.-H., Liu, L.-J., Pan, K.-L., Chen, W. & Tan, T.-H. Using the characteristics of pulse waveform to enhance the accuracy of blood pressure measurement by a multi-dimension regression model. Appl. Sci. 9, 2922 (2019).","journal-title":"Appl. Sci."},{"key":"77580_CR56","doi-asserted-by":"publisher","first-page":"151","DOI":"10.3390\/bios16030151","volume":"16","author":"L Xu","year":"2026","unstructured":"Xu, L. et al. Blood pressure estimation through pulse wave analysis using features extracted from carotid diameter distension waveforms. Biosensors 16, 151 (2026).","journal-title":"Biosensors"},{"key":"77580_CR57","doi-asserted-by":"publisher","unstructured":"Tang, J. et al. Calibration-free estimation algorithm for cuffless continuous blood pressure measurement based on ultrasonic devices. NSO 20240014 https:\/\/doi.org\/10.1360\/nso\/20240014 (2024).","DOI":"10.1360\/nso\/20240014"},{"key":"77580_CR58","doi-asserted-by":"publisher","first-page":"2392","DOI":"10.1109\/TBME.2018.2866332","volume":"65","author":"PM Nabeel","year":"2018","unstructured":"Nabeel, P. M., Jayaraj, J., Srinivasa, K., Mohanasankar, S. & Chenniappan, M. Bi-modal arterial compliance probe for calibration-free cuffless blood pressure estimation. IEEE Trans. Biomed. Eng. 65, 2392\u20132404 (2018).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"77580_CR59","doi-asserted-by":"publisher","DOI":"10.1038\/s41467-025-67118-4","volume":"17","author":"C Liang","year":"2025","unstructured":"Liang, C. et al. A conformal piezoelectric microsystem for demographic-adaptive and calibration-free cuffless blood pressure monitoring. Nat. Commun. 17, 439 (2025).","journal-title":"Nat. Commun."},{"key":"77580_CR60","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1109\/TBME.2016.2605451","volume":"64","author":"B Dong","year":"2017","unstructured":"Dong, B., Sun, C. & Zhang, H. F. Optical detection of ultrasound in photoacoustic imaging. IEEE Trans. Biomed. Eng. 64, 4\u201315 (2017).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"77580_CR61","doi-asserted-by":"publisher","first-page":"1499","DOI":"10.1109\/LPT.2012.2207099","volume":"24","author":"A Rosenthal","year":"2012","unstructured":"Rosenthal, A., Kellnberger, S., Sergiadis, G. & Ntziachristos, V. Wideband fiber-interferometer stabilization with variable phase. IEEE Photon. Technol. Lett. 24, 1499\u20131501 (2012).","journal-title":"IEEE Photon. Technol. Lett."},{"key":"77580_CR62","doi-asserted-by":"publisher","first-page":"1419","DOI":"10.1109\/JLT.2024.3485074","volume":"43","author":"RT Erdogan","year":"2025","unstructured":"Erdogan, R. T., Filonenko, G. A., Picken, S. J., Steeneken, P. G. & Westerveld, W. J. Optimizing cladding elasticity to enhance sensitivity in silicon photonic ultrasound sensors. J. Lightwave Technol. 43, 1419\u20131428 (2025).","journal-title":"J. Lightwave Technol."},{"key":"77580_CR63","doi-asserted-by":"publisher","first-page":"2401975","DOI":"10.1002\/adom.202401975","volume":"13","author":"CA Zimmermann","year":"2025","unstructured":"Zimmermann, C. A., Amouzou, K. N. & Ung, B. Recent advances in PDMS optical waveguides: properties, fabrication, and applications. Adv. Optical Mater. 13, 2401975 (2025).","journal-title":"Adv. Optical Mater."},{"key":"77580_CR64","doi-asserted-by":"publisher","first-page":"625","DOI":"10.1364\/OL.30.000625","volume":"30","author":"K Maslov","year":"2005","unstructured":"Maslov, K., Stoica, G. & Wang, L. V. In vivo dark-field reflection-mode photoacoustic microscopy. Opt. Lett. 30, 625\u2013627 (2005).","journal-title":"Opt. Lett."},{"key":"77580_CR65","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1007\/BF03215148","volume":"5","author":"O Loebich","year":"1972","unstructured":"Loebich, O. et al. The optical properties of gold: a review of their technical utilisation. Gold. Bull. 5, 2\u201310 (1972).","journal-title":"Gold. Bull."},{"key":"77580_CR66","doi-asserted-by":"publisher","first-page":"698","DOI":"10.1016\/S0008-6363(97)00003-5","volume":"33","author":"P Gizdulich","year":"1997","unstructured":"Gizdulich, P., Prentza, A. & Wesseling, K. H. Models of brachial to finger pulse wave distortion and pressure decrement. Cardiovasc Res 33, 698\u2013705 (1997).","journal-title":"Cardiovasc Res"},{"key":"77580_CR67","doi-asserted-by":"publisher","first-page":"1870","DOI":"10.1161\/01.CIR.94.8.1870","volume":"94","author":"WJ Bos","year":"1996","unstructured":"Bos, W. J., van Goudoever, J., van Montfrans, G. A., van den Meiracker, A. H. & Wesseling, K. H. Reconstruction of brachial artery pressure from noninvasive finger pressure measurements. Circulation 94, 1870\u20131875 (1996).","journal-title":"Circulation"},{"key":"77580_CR68","doi-asserted-by":"crossref","unstructured":"Guelen, I. et al. Validation of brachial artery pressure reconstruction from finger arterial pressure. J. Hypertens. 26, 1321\u20137 (2008).","DOI":"10.1097\/HJH.0b013e3282fe1d28"},{"key":"77580_CR69","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1016\/0895-7061(94)00000-2","volume":"8","author":"GA Rongen","year":"1995","unstructured":"Rongen, G. A. et al. Comparison of intrabrachial and finger blood pressure in healthy elderly volunteers. Am. J. Hypertens. 8, 237\u2013248 (1995).","journal-title":"Am. J. Hypertens."},{"key":"77580_CR70","doi-asserted-by":"publisher","first-page":"219","DOI":"10.1111\/j.1475-097X.1995.tb00513.x","volume":"15","author":"A Lindqvist","year":"1995","unstructured":"Lindqvist, A. Beat-to-beat agreement of non-invasive finger artery and invasive radial artery blood pressure in hypertensive patients taking cardiovascular medication. Clin. Physiol. 15, 219\u2013229 (1995).","journal-title":"Clin. Physiol."},{"key":"77580_CR71","doi-asserted-by":"publisher","first-page":"110976","DOI":"10.1016\/j.jclinane.2022.110976","volume":"83","author":"E Kho","year":"2022","unstructured":"Kho, E. et al. Clinical agreement of a novel algorithm to estimate radial artery blood pressure from the non-invasive finger blood pressure. J. Clin. Anesthesia 83, 110976 (2022).","journal-title":"J. Clin. Anesthesia"},{"key":"77580_CR72","doi-asserted-by":"publisher","unstructured":"Westerhof, N., Stergiopulos, N., Noble, M. I. M. & Westerhof, B. E. Snapshots of Hemodynamics: An Aid for Clinical Research and Graduate Education. https:\/\/doi.org\/10.1007\/978-3-319-91932-4 (Springer International Publishing, Cham, 2019).","DOI":"10.1007\/978-3-319-91932-4"},{"key":"77580_CR73","doi-asserted-by":"publisher","first-page":"1036","DOI":"10.1161\/HYPERTENSIONAHA.119.12674","volume":"73","author":"MK Armstrong","year":"2019","unstructured":"Armstrong, M. K. et al. Brachial and radial systolic blood pressure are not the same: evidence to support the Popeye phenomenon. Hypertension 73, 1036\u20131041 (2019).","journal-title":"Hypertension"},{"key":"77580_CR74","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1161\/HYPERTENSIONAHA.109.134379","volume":"54","author":"AP Avolio","year":"2009","unstructured":"Avolio, A. P. et al. Role of pulse pressure amplification in arterial hypertension: experts\u2019 opinion and review of the data. Hypertension 54, 375\u2013383 (2009).","journal-title":"Hypertension"},{"key":"77580_CR75","unstructured":"Penaz, J. Photoelectric measurement of blood pressure, volume and flow in the finger. in 104 (Dresden, 1973)."},{"key":"77580_CR76","doi-asserted-by":"publisher","unstructured":"S. V. Menon & C. S. Seelamantula. Robust Savitzky-Golay filters. in 2014 19th International Conference on Digital Signal Processing 688\u2013693 https:\/\/doi.org\/10.1109\/ICDSP.2014.6900752 (2014).","DOI":"10.1109\/ICDSP.2014.6900752"},{"key":"77580_CR77","doi-asserted-by":"publisher","unstructured":"Alnuaimy, A. N. H. et al. BM3D Denoising Algorithms for Medical Image. in 2024 35th Conference of Open Innovations Association (FRUCT) 135\u2013141 https:\/\/doi.org\/10.23919\/FRUCT61870.2024.10516419 (IEEE, 2024).","DOI":"10.23919\/FRUCT61870.2024.10516419"},{"key":"77580_CR78","doi-asserted-by":"publisher","unstructured":"IEEE Standard for Wearable, Cuffless Blood Pressure Measuring Devices - Amendment 1. https:\/\/doi.org\/10.1109\/IEEESTD.2019.8859685.","DOI":"10.1109\/IEEESTD.2019.8859685"},{"key":"77580_CR79","doi-asserted-by":"publisher","unstructured":"IEEE Standard for Wearable Cuffless Blood Pressure Measuring Devices. https:\/\/doi.org\/10.1109\/IEEESTD.2014.6882122.","DOI":"10.1109\/IEEESTD.2014.6882122"},{"key":"77580_CR80","doi-asserted-by":"publisher","unstructured":"Gelbert, G. SPADE-BP-DATA v2. Zenodo https:\/\/doi.org\/10.5281\/zenodo.20841180 (2026).","DOI":"10.5281\/zenodo.20841180"}],"container-title":["Nature Communications"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41467-026-77580-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41467-026-77580-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41467-026-77580-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,20]],"date-time":"2026-10-20T11:04:12Z","timestamp":1792494252000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41467-026-77580-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,17]]},"references-count":80,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["77580"],"URL":"https:\/\/doi.org\/10.1038\/s41467-026-77580-3","relation":{},"ISSN":["2041-1723"],"issn-type":[{"value":"2041-1723","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,17]]},"assertion":[{"value":"7 December 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 August 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 September 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Daniel H. Lange was previously the founder of ChroniSense Medical LTD. The remaining authors declare no competing interests.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Ethics"}}],"article-number":"10931"}}