{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,6]],"date-time":"2025-11-06T11:41:22Z","timestamp":1762429282527,"version":"3.37.3"},"reference-count":42,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2017,5,12]],"date-time":"2017-05-12T00:00:00Z","timestamp":1494547200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2017,5,12]],"date-time":"2017-05-12T00:00:00Z","timestamp":1494547200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Graft failure is currently a major concern for medical practitioners in treating Peripheral Vascular Disease (PVD) and Coronary Artery Disease (CAD). It is now widely accepted that unfavourable haemodynamic conditions play an essential role in the formation and development of intimal hyperplasia, which is the main cause of graft failure. This paper uses Computational Fluid Dynamics (CFD) to conduct a parametric study to enhance the design and performance of a novel prosthetic graft, which utilises internal ridge(s) to induce spiral flow. This design is primarily based on the identification of the blood flow as spiral in the whole arterial system and is believed to improve the graft longevity and patency rates at distal graft anastomoses. Four different design parameters were assessed in this work and the trailing edge orientation of the ridge was identified as the most important parameter to induce physiological swirling flow, while the height of the ridge also significantly contributed to the enhanced performance of this type of graft. Building on these conclusions, an enhanced configuration of spiral graft is proposed and compared against conventional and spiral grafts to reaffirm its potential benefits.<\/jats:p>","DOI":"10.1038\/s41598-017-01930-x","type":"journal-article","created":{"date-parts":[[2017,5,8]],"date-time":"2017-05-08T11:47:31Z","timestamp":1494244051000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":40,"title":["Optimisation of a Novel Spiral-Inducing Bypass Graft Using Computational Fluid Dynamics"],"prefix":"10.1038","volume":"7","author":[{"given":"Andres","family":"Ruiz-Soler","sequence":"first","affiliation":[]},{"given":"Foad","family":"Kabinejadian","sequence":"additional","affiliation":[]},{"given":"Mark A.","family":"Slevin","sequence":"additional","affiliation":[]},{"given":"Paulo J.","family":"Bartolo","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4747-277X","authenticated-orcid":false,"given":"Amir","family":"Keshmiri","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2017,5,12]]},"reference":[{"key":"1930_CR1","doi-asserted-by":"publisher","first-page":"1093","DOI":"10.1016\/j.avsg.2012.02.001","volume":"26","author":"PA Stonebridge","year":"2012","unstructured":"Stonebridge, P. A., Vermassen, F., Dick, J., Belch, J. J. F. & Houston, G. Spiral laminar flow prosthetic bypass graft: medium-term results from a first-in-man structured registry study. Ann. Vasc. Surg. \n                           26, 1093\u20139, doi:10.1016\/j.avsg.2012.02.001 (2012).","journal-title":"Ann. Vasc. Surg."},{"key":"1930_CR2","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1007\/s10047-003-0232-x","volume":"6","author":"H Haruguchi","year":"2003","unstructured":"Haruguchi, H. & Teraoka, S. Intimal hyperplasia and hemodynamic factors in arterial bypass and arteriovenous grafts: a review. J. Artif. Organs \n                           6, 227\u201335, doi:10.1007\/s10047-003-0232-x (2003).","journal-title":"J. Artif. Organs"},{"key":"1930_CR3","doi-asserted-by":"publisher","first-page":"e57","DOI":"10.1016\/S0828-282X(09)70486-6","volume":"25","author":"P Parang","year":"2009","unstructured":"Parang, P. & Arora, R. Coronary vein graft disease: pathogenesis and prevention. Can. J. Cardiol. \n                           25, e57\u201362, doi:10.1016\/S0828-282X(09)70486-6 (2009).","journal-title":"Can. J. Cardiol."},{"key":"1930_CR4","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1615\/CritRevBiomedEng.v29.i1.10","volume":"29","author":"JP Archie","year":"2001","unstructured":"Archie, J. P. et al. Hemodynamic parameters and early intimal thickening in branching blood vessels. Critical Reviews in Biomedical Engineering \n                           29, 1\u201364, doi:10.1615\/CritRevBiomedEng.v29.i1 (2001).","journal-title":"Critical Reviews in Biomedical Engineering"},{"key":"1930_CR5","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1186\/1475-925X-12-129","volume":"12","author":"DN Ghista","year":"2013","unstructured":"Ghista, D. N. & Kabinejadian, F. Coronary artery bypass grafting hemodynamics and anastomosis design: a biomedical engineering review. Biomed. Eng. Online \n                           12, 129, doi:10.1186\/1475-925X-12-129 (2013).","journal-title":"Biomed. Eng. Online"},{"key":"1930_CR6","doi-asserted-by":"publisher","first-page":"21","DOI":"10.14797\/mdcj-7-1-21","volume":"7","author":"PA Stonebridge","year":"2011","unstructured":"Stonebridge, P. A. Three-dimensional blood flow dynamics: spiral\/helical laminar flow. Methodist Debakey Cardiovasc. J. \n                           7, 21\u20136, doi:10.14797\/mdcj-7-1-21 (2011).","journal-title":"Methodist Debakey Cardiovasc. J."},{"key":"1930_CR7","doi-asserted-by":"publisher","first-page":"1360","DOI":"10.1016\/0140-6736(91)92238-W","volume":"338","author":"PA Stonebridge","year":"1991","unstructured":"Stonebridge, P. A. & Brophy, C. M. Spiral laminar flow in arteries? Lancet \n                           338, 1360\u20131361, doi:10.1016\/0140-6736(91)92238-W (1991).","journal-title":"Lancet"},{"key":"1930_CR8","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1042\/cs0910017","volume":"91","author":"PA Stonebridge","year":"1996","unstructured":"Stonebridge, P. A., Hoskins, P. R., Allan, P. L. & Belch, J. F. F. Spiral laminar flow in vivo. Clin. Sci. \n                           91, 17\u201321, doi:10.1042\/cs0910017 (1996).","journal-title":"Clin. Sci."},{"key":"1930_CR9","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1098\/rsif.2005.0044","volume":"2","author":"CG Caro","year":"2005","unstructured":"Caro, C. G., Cheshire, N. J. & Watkins, N. Preliminary comparative study of small amplitude helical and conventional ePTFE arteriovenous shunts in pigs. J. R. Soc. Interface \n                           2, 261\u2013266, doi:10.1098\/rsif.2005.0044 (2005).","journal-title":"J. R. Soc. Interface"},{"key":"1930_CR10","doi-asserted-by":"publisher","first-page":"1093","DOI":"10.1016\/j.avsg.2012.02.001","volume":"26","author":"PA Stonebridge","year":"2012","unstructured":"Stonebridge, P. A., Vermassen, F., Dick, J., Belch, J. J. F. & Houston, G. Spiral laminar flow prosthetic bypass graft: medium-term results from a first-in-man structured registry study. Ann. Vasc. Surg. \n                           26, 1093\u20139, doi:10.1016\/j.avsg.2012.02.001 (2012).","journal-title":"Ann. Vasc. Surg."},{"key":"1930_CR11","doi-asserted-by":"crossref","unstructured":"Kabinejadian, F. et al. Numerical Assessment of Novel Helical\/Spiral Grafts with Improved Hemodynamics for Distal Graft Anastomoses. PLoS One (2016).","DOI":"10.1371\/journal.pone.0165892"},{"key":"1930_CR12","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1016\/j.procir.2015.11.005","volume":"49","author":"A Keshmiri","year":"2016","unstructured":"Keshmiri, A., Ruiz-Soler, A., McElroy, M. & Kabinejadian, F. Numerical Investigation on the Geometrical Effects of Novel Graft Designs for Peripheral Artery Bypass Surgery. Procedia CIRP \n                           49, 147\u2013152, doi:10.1371\/journal.pone.0165892 (2016).","journal-title":"Procedia CIRP"},{"key":"1930_CR13","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1115\/1.429630","volume":"122","author":"SJ Sherwin","year":"2000","unstructured":"Sherwin, S. J. et al. The Influence of Out-of-Plane Geometry on the Flow Within a Distal End-to-Side Anastomosis. J. Biomech. Eng. \n                           122, 86\u201395, doi:10.1115\/1.429630 (2000).","journal-title":"J. Biomech. Eng."},{"key":"1930_CR14","doi-asserted-by":"publisher","first-page":"1225","DOI":"10.1016\/S0021-9290(02)00072-6","volume":"35","author":"Y Papaharilaou","year":"2002","unstructured":"Papaharilaou, Y., Doorly, D. J. & Sherwin, S. J. The influence of out-of-plane geometry on pulsatile flow within a distal end-to-side anastomosis. J. Biomech. \n                           35, 1225\u20131239, doi:10.1016\/S0021-9290(02)00072-6 (2002).","journal-title":"J. Biomech."},{"key":"1930_CR15","doi-asserted-by":"publisher","first-page":"710","DOI":"10.1007\/s10439-009-9636-y","volume":"37","author":"AN Cookson","year":"2009","unstructured":"Cookson, A. N., Doorly, D. J. & Sherwin, S. J. Mixing through stirring of steady flow in small amplitude helical tubes. Ann. Biomed. Eng. \n                           37, 710\u2013721, doi:10.1007\/s10439-009-9636-y (2009).","journal-title":"Ann. Biomed. Eng."},{"key":"1930_CR16","doi-asserted-by":"publisher","first-page":"192","DOI":"10.1097\/MAT.0b013e31819b34f2","volume":"55","author":"T Zheng","year":"2009","unstructured":"Zheng, T., Fan, Y., Xiong, Y., Jiang, W. & Deng, X. Hemodynamic performance study on small diameter helical grafts. ASAIO J. \n                           55, 192\u20139, doi:10.1097\/MAT.0b013e31819b34f2 (2009).","journal-title":"ASAIO J."},{"key":"1930_CR17","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1111\/j.1525-1594.2009.00797.x","volume":"34","author":"A Sun","year":"2010","unstructured":"Sun, A., Fan, Y. & Deng, X. Numerical Comparative Study on the Hemodynamic Performance of a New Helical Graft With Noncircular Cross Section and SwirlGraft. Artif. Organs \n                           34, 22\u201327, doi:10.1111\/aor.2010.34.issue-1 (2010).","journal-title":"Artif. Organs"},{"key":"1930_CR18","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1016\/j.medengphy.2010.09.005","volume":"33","author":"KE Lee","year":"2011","unstructured":"Lee, K. E., Lee, J. S. & Yoo, J. Y. A numerical study on steady flow in helically sinuous vascular prostheses. Med. Eng. Phys. \n                           33, 38\u201346, doi:10.1016\/j.medengphy.2010.09.005 (2011).","journal-title":"Med. Eng. Phys."},{"key":"1930_CR19","doi-asserted-by":"publisher","unstructured":"Liu, X., Sun, A., Fan, Y. & Deng, X. Physiological Significance of Helical Flow in the Arterial System and its Potential Clinical Applications. Ann. Biomed. Eng., doi:10.1007\/s10439-014-1097-2 (2014).","DOI":"10.1007\/s10439-014-1097-2"},{"key":"1930_CR20","doi-asserted-by":"publisher","first-page":"2295","DOI":"10.1016\/j.ultrasmedbio.2013.07.014","volume":"39","author":"E Kokkalis","year":"2013","unstructured":"Kokkalis, E. et al. Secondary flow in peripheral vascular prosthetic grafts using vector Doppler imaging. Ultrasound Med. Biol. \n                           39, 2295\u2013307, doi:10.1016\/j.ultrasmedbio.2013.07.014 (2013).","journal-title":"Ultrasound Med. Biol."},{"key":"1930_CR21","doi-asserted-by":"publisher","unstructured":"Do, H., Owida, A. A. A., Yang, W. & Morsi, Y. S. Numerical simulation of the haemodynamics in end-to-side anastomoses. Int JNum Meth Fluids 638\u2013650, doi:10.1002\/fld (2011).","DOI":"10.1002\/fld"},{"key":"1930_CR22","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1007\/s11517-014-1222-2","volume":"53","author":"F Kabinejadian","year":"2015","unstructured":"Kabinejadian, F. et al. Effects of a carotid covered stent with a novel membrane design on the blood flow regime and hemodynamic parameters distribution at the carotid artery bifurcation. Med. Biol. Eng. Comput. \n                           53, 165\u201377, doi:10.1007\/s11517-014-1222-2 (2015).","journal-title":"Med. Biol. Eng. Comput."},{"key":"1930_CR23","doi-asserted-by":"publisher","first-page":"593","DOI":"10.1142\/S0219519410003587","volume":"10","author":"F Kabinejadian","year":"2010","unstructured":"Kabinejadian, F., Chua, L. P., Ghista, D. N. & Tan, Y. S. CABG models flow simulation study on the effects of valve remnants in the venous graft. J. Mech. Med. Biol. \n                           10, 593\u2013609, doi:10.1142\/S0219519410003587 (2010).","journal-title":"J. Mech. Med. Biol."},{"key":"1930_CR24","unstructured":"Bird, R. B., Armstrong, R. C. & Hassanger, O. Dynamics of polymeric liquids, Fluid mechanics. Journal of Polymer Science Part C: Polymer Letters \n                           25 (1987)."},{"key":"1930_CR25","doi-asserted-by":"publisher","first-page":"860","DOI":"10.1016\/j.medengphy.2011.10.001","volume":"34","author":"F Kabinejadian","year":"2012","unstructured":"Kabinejadian, F. & Ghista, D. N. Compliant model of a coupled sequential coronary arterial bypass graft: Effects of vessel wall elasticity and non-Newtonian rheology on blood flow regime and hemodynamic parameters distribution. Med. Eng. Phys. \n                           34, 860\u2013872, doi:10.1016\/j.medengphy.2011.10.001 (2012).","journal-title":"Med. Eng. Phys."},{"key":"1930_CR26","doi-asserted-by":"crossref","first-page":"1520","DOI":"10.1152\/jappl.1994.76.4.1520","volume":"76","author":"JEJ Moore","year":"1994","unstructured":"Moore, J. E. J., Maier, S. E., Ku, D. N. & Boesiger, P. Hemodynamics in the abdominal aorta: a comparison of in vitro and in vivo measurements. J Appl Physiol \n                           76, 1520\u20131527 (1994).","journal-title":"J Appl Physiol"},{"key":"1930_CR27","doi-asserted-by":"publisher","first-page":"845","DOI":"10.1016\/0021-9290(95)95273-8","volume":"28","author":"K Perktold","year":"1995","unstructured":"Perktold, K. & Rappitsch, G. Computer simulation of local blood flow and vessel mechanics in a compliant carotid artery bifurcation model. J. Biomech. \n                           28, 845\u2013856, doi:10.1016\/0021-9290(95)95273-8 (1995).","journal-title":"J. Biomech."},{"key":"1930_CR28","doi-asserted-by":"publisher","first-page":"242","DOI":"10.1093\/cvr\/cvt044","volume":"99","author":"V Peiffer","year":"2013","unstructured":"Peiffer, V., Sherwin, S. J. & Weinberg, P. D. Does low and oscillatory wall shear stress correlate spatially with early atherosclerosis? A systematic review. Cardiovascular Research \n                           99, 242\u2013250, doi:10.1093\/cvr\/cvt044 (2013).","journal-title":"Cardiovascular Research"},{"key":"1930_CR29","doi-asserted-by":"crossref","unstructured":"Olgac, U., Kurtcuoglu, V., Saur, S. C. & Poulikakos, D. Identification of atherosclerotic lesion-prone sites through patient-specific simulation of low-density lipoprotein accumulation. In Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics) 5242 LNCS, 774\u2013781 (2008).","DOI":"10.1007\/978-3-540-85990-1_93"},{"key":"1930_CR30","doi-asserted-by":"publisher","first-page":"3464","DOI":"10.1109\/TBME.2011.2164919","volume":"58","author":"P Siogkas","year":"2011","unstructured":"Siogkas, P. et al. Multiscale - Patient-specific artery and atherogenesis models. IEEE Trans. Biomed. Eng. \n                           58, 3464\u20133468, doi:10.1109\/TBME.2011.2164919 (2011).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"1930_CR31","doi-asserted-by":"publisher","first-page":"2092","DOI":"10.1161\/CIRCULATIONAHA.109.901678","volume":"121","author":"KC Koskinas","year":"2010","unstructured":"Koskinas, K. C. et al. Natural history of experimental coronary atherosclerosis and vascular remodeling in relation to endothelial shear stress: A serial, in vivo intravascular ultrasound study. Circulation \n                           121, 2092\u20132101, doi:10.1161\/CIRCULATIONAHA.109.901678 (2010).","journal-title":"Circulation"},{"key":"1930_CR32","doi-asserted-by":"publisher","first-page":"621","DOI":"10.1161\/CIRCULATIONAHA.110.970038","volume":"123","author":"YS Chatzizisis","year":"2011","unstructured":"Chatzizisis, Y. S. et al. Augmented expression and activity of extracellular matrix-degrading enzymes in regions of low endothelial shear stress colocalize with coronary atheromata with thin fibrous caps in pigs. Circulation \n                           123, 621\u2013630, doi:10.1161\/CIRCULATIONAHA.110.970038 (2011).","journal-title":"Circulation"},{"key":"1930_CR33","doi-asserted-by":"crossref","unstructured":"FRY, D. L. Certain Chemorheologic Considerations Regarding the Blood Vascular Interface with Particular Reference to Coronary Artery Disease. Circulation \n                           40, IV-38-IV-57 (1969).","DOI":"10.1161\/01.CIR.40.5S4.IV-38"},{"key":"1930_CR34","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1016\/0141-5425(90)90131-6","volume":"12","author":"K Perktold","year":"1990","unstructured":"Perktold, K. & Resch, M. Numerical flow studies in human carotid artery bifurcations: basic discussion of the geometric factor in atherogenesis. J. Biomed. Eng. \n                           12, 111\u2013123, doi:10.1016\/0141-5425(90)90131-6 (1990).","journal-title":"J. Biomed. Eng."},{"key":"1930_CR35","doi-asserted-by":"publisher","first-page":"507","DOI":"10.1016\/0141-5425(91)90100-L","volume":"13","author":"K Perktold","year":"1991","unstructured":"Perktold, K., Peter, R. O., Resch, M. & Langs, G. Pulsatile non-Newtonian blood flow in three-dimensional carotid bifurcation models: a numerical study of flow phenomena under different bifurcation angles. J. Biomed. Eng. \n                           13, 507\u2013515, doi:10.1016\/0141-5425(91)90100-L (1991).","journal-title":"J. Biomed. Eng."},{"key":"1930_CR36","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1152\/physrev.00047.2009","volume":"91","author":"J-J Chiu","year":"2011","unstructured":"Chiu, J.-J. & Chien, S. Effects of disturbed flow on vascular endothelium: pathophysiological basis and clinical perspectives. Physiol. Rev. \n                           91, 327\u2013387, doi:10.1152\/physrev.00047.2009 (2011).","journal-title":"Physiol. Rev."},{"key":"1930_CR37","first-page":"E54","volume":"11","author":"C Bechara","year":"2014","unstructured":"Bechara, C. Comparing Short and Midterm Infrainguinal Bypass Patency Rates Between Two ePTFE Prosthetic Grafts: Spiral Laminar Flow and Propaten. Vasc. Dis. Manag. \n                           11, E54\u2013E58 (2014).","journal-title":"Vasc. Dis. Manag."},{"key":"1930_CR38","doi-asserted-by":"publisher","first-page":"1708","DOI":"10.1098\/rsif.2011.0116","volume":"8","author":"PE Vincent","year":"2011","unstructured":"Vincent, P. E., Plata, A. M., Hunt, A. A. E., Weinberg, P. D. & Sherwin, S. J. Blood flow in the rabbit aortic arch and descending thoracic aorta. J. R. Soc. Interface \n                           8, 1708\u201319, doi:10.1098\/rsif.2011.0116 (2011).","journal-title":"J. R. Soc. Interface"},{"key":"1930_CR39","doi-asserted-by":"publisher","first-page":"1085","DOI":"10.1002\/jmri.20900","volume":"25","author":"A Frydrychowicz","year":"2007","unstructured":"Frydrychowicz, A. et al. Visualization of iliac and proximal femoral artery hemodynamics using time-resolved 3D phase contrast MRI at 3T. J. Magn. Reson. Imaging \n                           25, 1085\u20131092, doi:10.1002\/jmri.v25:5 (2007).","journal-title":"J. Magn. Reson. Imaging"},{"key":"1930_CR40","doi-asserted-by":"crossref","unstructured":"McElroy, M. & Keshmiri, A. Impact of Using Conventional Inlet\/Outlet Boundary Conditions on Haemodynamic Metrics in a Subject-Specific Rabbit Aorta. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 0954411917699237 (2017).","DOI":"10.1177\/0954411917699237"},{"key":"1930_CR41","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1098\/rspa.1996.0011","volume":"452","author":"CG Caro","year":"1996","unstructured":"Caro, C. G. et al. Non-Planar Curvature and Branching of Arteries and Non-Planar-Type Flow. Proc. R. Soc. A Math. Phys. Eng. Sci \n                           452, 185\u2013197, doi:10.1098\/rspa.1996.0011 (1996).","journal-title":"Proc. R. Soc. A Math. Phys. Eng. Sci"},{"key":"1930_CR42","doi-asserted-by":"publisher","first-page":"1060","DOI":"10.1016\/S0741-5214(03)00706-7","volume":"38","author":"WM Klein","year":"2003","unstructured":"Klein, W. M., Bartels, L. W., Bax, L., van der Graaf, Y. & Mali, W. P. Magnetic resonance imaging measurement of blood volume flow in peripheral arteries in healthy subjects. J. Vasc. Surg. \n                           38, 1060\u20131066, doi:10.1016\/S0741-5214(03)00706-7 (2003).","journal-title":"J. Vasc. Surg."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-017-01930-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-017-01930-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-017-01930-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,23]],"date-time":"2022-12-23T04:15:39Z","timestamp":1671768939000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-017-01930-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,5,12]]},"references-count":42,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2017,12]]}},"alternative-id":["1930"],"URL":"https:\/\/doi.org\/10.1038\/s41598-017-01930-x","relation":{},"ISSN":["2045-2322"],"issn-type":[{"type":"electronic","value":"2045-2322"}],"subject":[],"published":{"date-parts":[[2017,5,12]]},"assertion":[{"value":"1 December 2016","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 April 2017","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 May 2017","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare that they have no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}}],"article-number":"1865"}}