{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,30]],"date-time":"2025-09-30T00:08:26Z","timestamp":1759190906991},"reference-count":28,"publisher":"American Speech Language Hearing Association","issue":"3S","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Am J Audiol"],"published-print":{"date-parts":[[2017,10,12]]},"abstract":"<jats:sec><jats:title>Purpose<\/jats:title><jats:p>In spite of all the efforts to implement workplace hearing conservation programs, noise-induced hearing loss remains the leading cause of disability for North American workers. Nonetheless, an individual's susceptibility to noise-induced hearing loss can be estimated by monitoring changes in hearing status in relation to the level of ambient noise exposure.<\/jats:p><jats:p>The purpose of this study was to validate an approach that could improve workplace hearing conservation practices. The approach was developed using a portable and robust system designed for noisy environments and consisted of taking continuous measurements with high temporal resolution of the health status of the inner ear using otoacoustic emissions (OAEs).<\/jats:p><\/jats:sec><jats:sec><jats:title>Method<\/jats:title><jats:p>A pilot study was conducted in a laboratory, exposing human subjects to industrial noise recordings at realistic levels. In parallel, OAEs were measured periodically using the designed OAE system as well as with a commercially available OAE system, used as a reference.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Variations in OAE levels were analyzed and discussed along with the limitations of the reference and designed systems.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>This study demonstrates that the monitoring of an individual's OAEs could be useful in monitoring temporary changes in hearing status induced by exposure to ambient noise and could be considered as a new tool for effective hearing conservation programs in the workplace.<\/jats:p><\/jats:sec>","DOI":"10.1044\/2017_aja-17-0003","type":"journal-article","created":{"date-parts":[[2017,10,19]],"date-time":"2017-10-19T19:34:36Z","timestamp":1508441676000},"page":"352-368","source":"Crossref","is-referenced-by-count":8,"title":["Field Monitoring of Otoacoustic Emissions During Noise Exposure: Pilot Study in Controlled Environment"],"prefix":"10.1044","volume":"26","author":[{"given":"Vincent","family":"Nadon","sequence":"first","affiliation":[{"name":"\u00c9cole de Technologie Sup\u00e9rieure, Montr\u00e9al, Qu\u00e9bec, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Annelies","family":"Bockstael","sequence":"additional","affiliation":[{"name":"WAVES Research Group, Ghent University, Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dick","family":"Botteldooren","sequence":"additional","affiliation":[{"name":"WAVES Research Group, Ghent University, Belgium"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J\u00e9r\u00e9mie","family":"Voix","sequence":"additional","affiliation":[{"name":"\u00c9cole de Technologie Sup\u00e9rieure, Montr\u00e9al, Qu\u00e9bec, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1310","reference":[{"key":"e_1_3_2_2_1","doi-asserted-by":"publisher","DOI":"10.1080\/10803548.2009.11076795"},{"key":"e_1_3_2_3_1","unstructured":"Carnegie Mellon University. (1992). NOISEX-92 database. Retrieved from http:\/\/www.speech.cs.cmu.edu\/comp.speech\/Section1\/Data\/noisex.html"},{"key":"e_1_3_2_4_1","unstructured":"CRITIAS. (2016 December). Chaire de Recherche Industrielle en Technologies Intra-Auriculaire CRSNG-EERS (CRITIAS). Retrieved from http:\/\/s11403.p20.sites.pressdns.com\/the-technology\/arp\/"},{"key":"e_1_3_2_5_1","doi-asserted-by":"publisher","DOI":"10.1121\/1.3505123"},{"issue":"1","key":"e_1_3_2_6_1","first-page":"12","article-title":"Effects of noise and exercise on distortion product otoacoustic emissions","volume":"187","author":"Engdahl B.","year":"2004","journal-title":"Hearing Research"},{"key":"e_1_3_2_7_1","unstructured":"ISO. (2014). ISO 1999:2013 - Acoustics \u2013 Estimation of noise-induced hearing loss. Retrieved from http:\/\/www.iso.org\/iso\/catalogue_detail.htm?csnumber=45103"},{"key":"e_1_3_2_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/0378-5955(86)90087-0"},{"key":"e_1_3_2_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinph.2009.11.003"},{"key":"e_1_3_2_10_1","doi-asserted-by":"publisher","DOI":"10.3109\/14992020903300431"},{"key":"e_1_3_2_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0378-5955(97)00105-6"},{"key":"e_1_3_2_12_1","doi-asserted-by":"publisher","DOI":"10.1121\/1.401308"},{"key":"e_1_3_2_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.apacoust.2014.09.001"},{"key":"e_1_3_2_14_1","doi-asserted-by":"publisher","DOI":"10.3813\/AAA.919058"},{"key":"e_1_3_2_15_1","first-page":"1955","volume-title":"Assessment of otoacoustic emission probe fit at the work floor","author":"Nadon V.","year":"2015"},{"key":"e_1_3_2_16_1","volume-title":"Signal processing techniques for continuous monitoring of distortion product otoacoustic emissions in noisy industrial environments","author":"Nadon V.","year":"2014"},{"key":"e_1_3_2_17_1","volume-title":"Google Patents","author":"Nadon V.","year":"2015"},{"key":"e_1_3_2_18_1","unstructured":"Neely S. T. & Liu Z. (1994). EMAV: Otoacoustic emission averager (Technical Memo No. 17) . Boys Town National Research Hospital Omaha NE. Retrieved from http:\/\/audres.org\/"},{"key":"e_1_3_2_19_1","unstructured":"NIOSH. (2016 July). National Institute for Occupational Safety and Health: Noise and hearing loss prevention. Retrieved from https:\/\/www.cdc.gov\/niosh\/topics\/noise\/"},{"issue":"12","key":"e_1_3_2_20_1","first-page":"75","article-title":"Otoacoustic emissions in industrial hearing loss assessment","volume":"3","author":"Sliwinska-Kowalska M.","year":"2001","journal-title":"Noise and Health"},{"issue":"7","key":"e_1_3_2_21_1","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1055\/s-0042-1745621","article-title":"Effects of speech babble on transient evoked otoacoustic emissions in normal-hearing adults","volume":"12","author":"Smith S.","year":"2001","journal-title":"Journal of the American Academy of Audiology"},{"key":"e_1_3_2_22_1","unstructured":"Sonomax. (2016 December). SonoFit. Retrieved from http:\/\/sonomax.com\/assets\/files\/pdf\/Sonomax-SonoFitSystem-Sheet.pdf"},{"key":"e_1_3_2_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.heares.2007.12.004"},{"key":"e_1_3_2_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/0378-5955(94)90067-1"},{"key":"e_1_3_2_25_1","doi-asserted-by":"publisher","DOI":"10.3109\/14992027.2014.913210"},{"key":"e_1_3_2_26_1","doi-asserted-by":"publisher","DOI":"10.3109\/00206099909073001"},{"key":"e_1_3_2_27_1","doi-asserted-by":"publisher","DOI":"10.1121\/1.3125769"},{"issue":"3","key":"e_1_3_2_28_1","first-page":"1126","article-title":"Evaluation of distortion product otoacoustic emissions (DPOAEs) among workers at an industrial company exposed to different industrial noise levels in 2014","volume":"7","author":"Zare S.","year":"2015","journal-title":"Electronic Physician"},{"key":"e_1_3_2_29_1","unstructured":"Zoom. (2016 December). Zoom H5. Retrieved from https:\/\/www.zoom.co.jp\/products\/handy-recorder\/h5-handy-recorder"}],"container-title":["American Journal of Audiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/pubs.asha.org\/doi\/pdf\/10.1044\/2017_AJA-17-0003","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,8,4]],"date-time":"2022-08-04T22:16:57Z","timestamp":1659651417000},"score":1,"resource":{"primary":{"URL":"http:\/\/pubs.asha.org\/doi\/10.1044\/2017_AJA-17-0003"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,10,12]]},"references-count":28,"journal-issue":{"issue":"3S","published-print":{"date-parts":[[2017,10,12]]}},"alternative-id":["10.1044\/2017_AJA-17-0003"],"URL":"https:\/\/doi.org\/10.1044\/2017_aja-17-0003","relation":{},"ISSN":["1059-0889","1558-9137"],"issn-type":[{"value":"1059-0889","type":"print"},{"value":"1558-9137","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,10,12]]}}}