{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,20]],"date-time":"2026-10-20T04:37:00Z","timestamp":1792471020333,"version":"4.5.0"},"reference-count":17,"publisher":"American Speech Language Hearing Association","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Am J Speech Lang Pathol"],"published-print":{"date-parts":[[2019,2,21]]},"abstract":"<jats:sec>\n            <jats:title>Purpose<\/jats:title>\n            <jats:p>Pharyngeal high-resolution manometry is an emerging practice for diagnosis of swallowing disorders in the upper aerodigestive tract. Advancement of a catheter through the upper esophageal sphincter may introduce safety considerations. There are no published studies of catheter placement complications, side effects, or tolerability. This study examines patient-reported side effects and tolerability of pharyngeal high-resolution manometry.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Method<\/jats:title>\n            <jats:p>Data were collected prospectively from 133 adult patients who underwent pharyngeal high-resolution manometry for the 1st time. Patients rated tolerability specific to \u201cnose\u201d and \u201cthroat\u201d using a visual analog scale for 4 procedure time points: catheter passage, during the procedure, catheter removal, and after the procedure. Complications during catheter passage and removal were recorded. A telephone call was placed to the patient within 6 days to survey side effects experienced after the procedure.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>\n              The patient sample was composed of 91 males and 42 females with a mean age of 66 years (\n              <jats:italic>SD<\/jats:italic>\n              = 14.4). Tolerability scores for catheter passage showed no significant difference (\n              <jats:italic>p<\/jats:italic>\n              = .7288) in the nose versus throat. Tolerability for females was significantly less (\n              <jats:italic>p<\/jats:italic>\n              = .0144) than that for males. Participants with the shortest procedure duration showed greatest discomfort in the nose (\n              <jats:italic>p<\/jats:italic>\n              = .0592) and throat (\n              <jats:italic>p<\/jats:italic>\n              = .0286). Complications included gag response (14%), emesis (2%), and epistaxis (&lt; 1%). Side effects included sore throat (16%), nose discomfort (16%), coughing (11 %), nosebleed (4%), and nausea\/vomiting (4%).\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>High-resolution manometry appears to have high patient tolerability with low incidence of side effects. Rates of complications and side effects are similar to those reported for other transnasal procedures.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1044\/2018_ajslp-18-0039","type":"journal-article","created":{"date-parts":[[2018,12,5]],"date-time":"2018-12-05T02:00:49Z","timestamp":1543975249000},"page":"43-52","source":"Crossref","is-referenced-by-count":21,"title":["Safety and Tolerability of Pharyngeal High-Resolution Manometry"],"prefix":"10.1044","volume":"28","author":[{"given":"Molly A.","family":"Knigge","sequence":"first","affiliation":[{"name":"University of Wisconsin\u2013Madison"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stevie","family":"Marvin","sequence":"additional","affiliation":[{"name":"University of Wisconsin\u2013Madison"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Susan L.","family":"Thibeault","sequence":"additional","affiliation":[{"name":"Department of Surgery, University of Wisconsin\u2013Madison"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1310","reference":[{"key":"e_1_3_2_2_1","unstructured":"American Speech-Language-Hearing Association. (2003). National Outcomes Measurement System (NOMS): Adult speech-language pathology user's guide. Rockville MD: Author."},{"key":"e_1_3_2_3_1","doi-asserted-by":"publisher","DOI":"10.1007\/s004559910008"},{"key":"e_1_3_2_4_1","doi-asserted-by":"publisher","DOI":"10.1177\/000348940511400301"},{"key":"e_1_3_2_5_1","doi-asserted-by":"publisher","DOI":"10.1067\/mhn.2001.117873"},{"key":"e_1_3_2_6_1","doi-asserted-by":"publisher","DOI":"10.1097\/00005537-200301000-00004"},{"key":"e_1_3_2_7_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2982.2004.00539.x"},{"key":"e_1_3_2_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.physbeh.2016.08.005"},{"key":"e_1_3_2_9_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11894-012-0253-9"},{"key":"e_1_3_2_10_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00455-013-9494-5"},{"key":"e_1_3_2_11_1","doi-asserted-by":"publisher","DOI":"10.1044\/jslhr.4006.1352"},{"key":"e_1_3_2_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.surg.2010.07.010"},{"key":"e_1_3_2_13_1","doi-asserted-by":"publisher","DOI":"10.1159\/000446985"},{"key":"e_1_3_2_14_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00455-012-9405-1"},{"key":"e_1_3_2_15_1","doi-asserted-by":"publisher","DOI":"10.1177\/0003489415570935"},{"key":"e_1_3_2_16_1","doi-asserted-by":"publisher","DOI":"10.1067\/mhn.2003.52"},{"key":"e_1_3_2_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpain.2005.03.009"},{"key":"e_1_3_2_18_1","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.108.520775"}],"container-title":["American Journal of Speech-Language Pathology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/pubs.asha.org\/doi\/pdf\/10.1044\/2018_AJSLP-18-0039","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,9,6]],"date-time":"2022-09-06T22:11:50Z","timestamp":1662502310000},"score":1,"resource":{"primary":{"URL":"http:\/\/pubs.asha.org\/doi\/10.1044\/2018_AJSLP-18-0039"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,2,21]]},"references-count":17,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,2,21]]}},"alternative-id":["10.1044\/2018_AJSLP-18-0039"],"URL":"https:\/\/doi.org\/10.1044\/2018_ajslp-18-0039","relation":{},"ISSN":["1058-0360","1558-9110"],"issn-type":[{"value":"1058-0360","type":"print"},{"value":"1558-9110","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,2,21]]}}}