{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T23:36:15Z","timestamp":1791934575281,"version":"4.3.4"},"reference-count":23,"publisher":"American Speech Language Hearing Association","issue":"3S","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Am J Audiol"],"published-print":{"date-parts":[[2022,9,21]]},"abstract":"<jats:sec>\n            <jats:title>Objective:<\/jats:title>\n            <jats:p>The objective of this study was to determine whether changes to adult hearing aid provision during COVID-19 affected patient outcomes or service efficiency.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>A service evaluation compared three cohorts: patients who had hearing aid provision prior to the COVID-19 pandemic (the conventional pathway); patients who had hearing aid provision during the initial national lockdown (remote fittings); and patients who had hearing aid provision during the gradual reopening phase (a blended service with both face-to-face and remote service provision). Outcomes measured the effectiveness and efficiency of the service, using the Glasgow Hearing Aid Benefit\/Difference Profiles (GHABP\/DP) and number of follow-up appointments required. Results were assessed using descriptive statistics and error bars, separately for new and existing users.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Sample:<\/jats:title>\n            <jats:p>This study included 240 hearing aid users.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Remote fittings adversely impacted the effectiveness of provision for new hearing aid users with a reduction in all GHABP domains. While new users' benefit was equally as good for blended and conventional service provision, blended provision was less efficient and required more follow-up visits. For existing hearing aid users, no differences were seen in GHADP outcomes of different pathways and remote fittings increased service efficiency.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>Remote hearing aid fittings are less effective for new users than hearing aids fitted using standard face-to-face service provision or service provision using a blended model of remote and face-to-face care. Current pathways using a blended model of care are less efficient but equally effective for new hearing aid users compared with provision prior to COVID-19 and result in equivalent patient outcomes in terms of benefit.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Supplemental Material:<\/jats:title>\n            <jats:p>\n              <jats:ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" ext-link-type=\"uri\" xlink:href=\"https:\/\/doi.org\/10.23641\/asha.21067585\">https:\/\/doi.org\/10.23641\/asha.21067585<\/jats:ext-link>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.1044\/2022_aja-21-00195","type":"journal-article","created":{"date-parts":[[2022,9,14]],"date-time":"2022-09-14T22:12:16Z","timestamp":1663193536000},"page":"876-891","source":"Crossref","is-referenced-by-count":5,"title":["Did Changes to Adult Hearing Aid Pathways Due to COVID-19 Affect Patient Outcomes? A Service Evaluation"],"prefix":"10.1044","volume":"31","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4024-1381","authenticated-orcid":false,"given":"Zoe","family":"Duckworth","sequence":"first","affiliation":[{"name":"Manchester Centre for Audiology and Deafness, School of Healthcare Science, The University of Manchester, United Kingdom"},{"name":"University Hospitals Plymouth NHS Trust, United Kingdom"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1699-6864","authenticated-orcid":false,"given":"Adam","family":"Beckman","sequence":"additional","affiliation":[{"name":"University Hospitals Plymouth NHS Trust, United Kingdom"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5940-622X","authenticated-orcid":false,"given":"Antje","family":"Heinrich","sequence":"additional","affiliation":[{"name":"Manchester Centre for Audiology and Deafness, School of Healthcare Science, The University of Manchester, United Kingdom"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1310","reference":[{"key":"e_1_3_2_2_1","doi-asserted-by":"publisher","DOI":"10.1080\/14992020500057830"},{"key":"e_1_3_2_3_1","doi-asserted-by":"publisher","DOI":"10.3766\/jaaa.23.10.3"},{"key":"e_1_3_2_4_1","doi-asserted-by":"publisher","DOI":"10.1177\/2331216521999563"},{"key":"e_1_3_2_5_1","unstructured":"British Society of Audiology. (2016). Practice guidance common principles of rehabilitation for adults in audiology services. \nhttps:\/\/www.thebsa.org.uk\/wp-content\/uploads\/2016\/10\/OD104-52-Practice-Guidance-Common-Principles-of-Rehabilitation-for-Adults-in-Audiology-Services-2016.pdf"},{"key":"e_1_3_2_6_1","unstructured":"British Society of Audiology. (2018). Practice guidance: Guidance on the verification of hearing devices using probe microphone measurements. \nhttps:\/\/www.thebsa.org.uk\/resources\/guidance-on-the-verification-of-hearing-devices-using-probe-microphone-measurements\/"},{"key":"e_1_3_2_7_1","doi-asserted-by":"publisher","DOI":"10.1089\/tmj.2019.0109"},{"key":"e_1_3_2_8_1","doi-asserted-by":"publisher","DOI":"10.3109\/14992020309074629"},{"key":"e_1_3_2_9_1","unstructured":"Department of Health. (2021). The NHS Constitution for England. \nhttps:\/\/www.gov.uk\/government\/publications\/the-nhs-constitution-for-england\/the-nhs-constitution-for-england"},{"key":"e_1_3_2_10_1","volume-title":"A national survey of adult rehabilitation practice in UK audiology services","author":"Ferguson M.","year":"2015","unstructured":"Ferguson, M. , Coulson, N. , Handscomb, L. , Brassington, W. , & Downes, B. (2015). A national survey of adult rehabilitation practice in UK audiology services. NIHR Nottingham Hearing Biomedical Research Unit. http:\/\/www.thebsa.org.uk\/wp-content\/uploads\/2017\/03\/A-national-survey-of-adult-rehabilitation-practice-in-UK-audiology-services.pdf"},{"key":"e_1_3_2_11_1","doi-asserted-by":"publisher","DOI":"10.3109\/14992027.2014.900196"},{"key":"e_1_3_2_12_1","doi-asserted-by":"publisher","DOI":"10.1177\/2055207619845831"},{"key":"e_1_3_2_13_1","unstructured":"Joint Guidance from the UK's Professional Bodies. (2021). Audiology and otology guidance during COVID 19. \nhttps:\/\/www.baaudiology.org\/app\/uploads\/2021\/09\/JointAudiologyOtologyGuidance-Oct-21.pdf"},{"key":"e_1_3_2_14_1","doi-asserted-by":"publisher","DOI":"10.1038\/nmeth.2659"},{"key":"e_1_3_2_15_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.AUD.0000058114.20741.4D"},{"key":"e_1_3_2_16_1","doi-asserted-by":"publisher","DOI":"10.3109\/14992027.2015.1104736"},{"key":"e_1_3_2_17_1","unstructured":"National Institute for Health and Care Excellence. (2018). Hearing loss in adults: Assessment and management: NICE guideline [NG98]. \nhttps:\/\/www.nice.org.uk\/guidance\/ng98\/chapter\/Recommendations#follow-up-in-audiology-services"},{"key":"e_1_3_2_18_1","doi-asserted-by":"publisher","DOI":"10.5604\/01.3001.0014.1475"},{"key":"e_1_3_2_19_1","doi-asserted-by":"publisher","DOI":"10.3109\/14992027.2011.582165"},{"key":"e_1_3_2_20_1","doi-asserted-by":"publisher","DOI":"10.1080\/14992027.2020.1814432"},{"key":"e_1_3_2_21_1","first-page":"1","article-title":"Validation of teleaudiology hearing aid rehabilitation services for adults: A systematic review of outcome measurement tools","author":"Tao K.","year":"2021","unstructured":"Tao, K. , Brennan-Jones, C. G. , Jayakody, D. , Swanepoel, D. , Fava, G. , Bellekom, S. R. , & Eikelboom, R. H. (2021). Validation of teleaudiology hearing aid rehabilitation services for adults: A systematic review of outcome measurement tools. Disability and Rehabilitation, 1\u201318. https:\/\/doi.org\/10.1080\/09638288.2021.1900928","journal-title":"Disability and Rehabilitation"},{"key":"e_1_3_2_22_1","doi-asserted-by":"publisher","DOI":"10.1080\/14992027.2020.1805804"},{"key":"e_1_3_2_23_1","unstructured":"University Hospitals Plymouth NHS Trust. (2022). Friends and family test [Online]. https:\/\/www.plymouthhospitals.nhs.uk\/friends-and-family-test"},{"issue":"03","key":"e_1_3_2_24_1","first-page":"224","article-title":"The effect of stimulus audibility on the relationship between pure-tone average and speech recognition in noise ability","volume":"31","author":"Vermiglio A.","year":"2021","unstructured":"Vermiglio, A. , Soli, S. , Freed, D. , & Fang, X. (2021). The effect of stimulus audibility on the relationship between pure-tone average and speech recognition in noise ability. Journal of the American Academy of Audiology, 31(03), 224\u2013232. https:\/\/doi.org\/10.3766\/jaaa.19031","journal-title":"Journal of the American Academy of Audiology"}],"container-title":["American Journal of Audiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/pubs.asha.org\/doi\/pdf\/10.1044\/2022_AJA-21-00195","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,18]],"date-time":"2022-11-18T22:34:46Z","timestamp":1668810886000},"score":1,"resource":{"primary":{"URL":"http:\/\/pubs.asha.org\/doi\/10.1044\/2022_AJA-21-00195"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,21]]},"references-count":23,"journal-issue":{"issue":"3S","published-print":{"date-parts":[[2022,9,21]]}},"alternative-id":["10.1044\/2022_AJA-21-00195"],"URL":"https:\/\/doi.org\/10.1044\/2022_aja-21-00195","relation":{},"ISSN":["1059-0889","1558-9137"],"issn-type":[{"value":"1059-0889","type":"print"},{"value":"1558-9137","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,9,21]]}}}