{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,13]],"date-time":"2025-05-13T22:22:51Z","timestamp":1747174971960,"version":"3.40.5"},"reference-count":22,"publisher":"American Speech Language Hearing Association","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Am J Audiol"],"published-print":{"date-parts":[[2024,9,3]]},"abstract":"<jats:sec>\n            <jats:title>Objective:<\/jats:title>\n            <jats:p>Phone- and tablet-based hearing testing systems are now widely available. Here, we evaluated one such system from TympaHealth by comparing air conduction thresholds and resultant hearing aid targets and output, measured with the TympaHealth system with those measured using standard audiometry.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>The hearing thresholds of 35 adults were measured using standard audiometry and the TympaHealth system. Each set of thresholds was used to generate NAL-NL2 targets and program a hearing aid. The data from each system were compared.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Bland\u2013Altman analyses showed overall mean differences between thresholds measured with each system to be small, with 85% of TympaHealth thresholds being within \u00b15 dB of the standard audiometric thresholds, although TympaHealth thresholds were higher (poorer) than the standard audiometric thresholds. The hearing aid targets and gains generated from the standard audiometric thresholds were lower (less amplification) than those generated from the TympaHealth thresholds but again, mean differences at each frequency were small and likely imperceptible.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>These findings support the possibility that valid hearing testing can take place outside of a clinical booth using portable systems like that from TympaHealth, opening up the possibility of testing hearing and fitting hearing aids through pharmacies, opticians, and in care homes.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1044\/2024_aja-24-00002","type":"journal-article","created":{"date-parts":[[2024,6,7]],"date-time":"2024-06-07T17:02:26Z","timestamp":1717779746000},"page":"740-755","source":"Crossref","is-referenced-by-count":0,"title":["A Comparison of Hearing Thresholds, and the Resulting Prescribed Gain and Hearing Aid Outputs, Using Gold Standard Audiometry and the TympaHealth Hearing Assessment Tool"],"prefix":"10.1044","volume":"33","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9997-0845","authenticated-orcid":false,"given":"Gabrielle H.","family":"Saunders","sequence":"first","affiliation":[{"name":"Manchester Centre for Audiology and Deafness, University of Manchester, United Kingdom"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Adam","family":"Walker","sequence":"additional","affiliation":[{"name":"ASE Audiology, Manchester, United Kingdom"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Calvin","family":"Heal","sequence":"additional","affiliation":[{"name":"Centre for Biostatistics, University of Manchester, United Kingdom"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Krishan","family":"Ramdoo","sequence":"additional","affiliation":[{"name":"TympaHealth Technologies Ltd, London, United Kingdom"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1310","reference":[{"key":"e_1_3_2_2_1","doi-asserted-by":"publisher","DOI":"10.1177\/2331216521999563"},{"issue":"5","key":"e_1_3_2_3_1","first-page":"32","article-title":"Guidelines for the audiologic management of adult hearing loss","volume":"18","author":"American Academy of Audiology Task Force Committee","year":"2006","unstructured":"American Academy of Audiology Task Force Committee. (2006). Guidelines for the audiologic management of adult hearing loss. Audiology Today, 18(5), 32\u201336. https:\/\/www.audiology.org\/practice-guideline\/guidelines-for-the-audiologic-management-of-adult-hearing-impairment\/","journal-title":"Audiology Today"},{"key":"e_1_3_2_4_1","unstructured":"American Speech-Language-Hearing Association. (2005). Guidelines for manual pure-tone threshold audiometry [Guidelines]. https:\/\/www.asha.org\/policy\/gl2005-00014\/"},{"issue":"2","key":"e_1_3_2_5_1","first-page":"227","article-title":"Matching real-ear targets for adult hearing aid fittings: NAL-NL1 and DSL v5.0 prescriptive formulae","volume":"41","author":"Baker S.","year":"2017","unstructured":"Baker, S., & Jenstadt, L. (2017). Matching real-ear targets for adult hearing aid fittings: NAL-NL1 and DSL v5.0 prescriptive formulae. Canadian Journal of Speech-Language Pathology and Audiology, 41(2), 227\u2013235.","journal-title":"Canadian Journal of Speech-Language Pathology and Audiology"},{"key":"e_1_3_2_6_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40463-019-0385-0"},{"key":"e_1_3_2_7_1","article-title":"Recommended procedure","author":"British Society of Audiology","year":"2018","unstructured":"British Society of Audiology. (2018). Recommended procedure: Pure-tone air-conduction and bone conduction threshold audiometry with and without masking. https:\/\/www.thebsa.org.uk\/wp-content\/uploads\/2024\/01\/Recommended-Procedure-Pure-Tone-Audiometry-2018.pdf [PDF]","journal-title":"Pure-tone air-conduction and bone conduction threshold audiometry with and without masking"},{"key":"e_1_3_2_8_1","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0000000000001135"},{"key":"e_1_3_2_9_1","article-title":"Discrimination of gain increments in speech","volume":"23","author":"Caswell-Midwinter B.","year":"2019","unstructured":"Caswell-Midwinter, B., & Whitmer, W. M. (2019a). Discrimination of gain increments in speech. Trends in Hearing, 23. https:\/\/doi.org\/10.1177\/2331216519886684","journal-title":"Trends in Hearing"},{"key":"e_1_3_2_10_1","article-title":"Discrimination of gain increments in speech-shaped noises","volume":"23","author":"Caswell-Midwinter B.","year":"2019","unstructured":"Caswell-Midwinter, B., & Whitmer, W. M. (2019b). Discrimination of gain increments in speech-shaped noises. Trends in Hearing, 23. https:\/\/doi.org\/10.1177\/2331216518820220","journal-title":"Trends in Hearing"},{"key":"e_1_3_2_11_1","doi-asserted-by":"publisher","DOI":"10.2196\/28378"},{"key":"e_1_3_2_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjoto.2022.103552"},{"key":"e_1_3_2_13_1","article-title":"Good practice guidance for adult hearing aid fitting and services","volume":"36","author":"Gatehouse S.","year":"2001","unstructured":"Gatehouse, S., Stephens, S. D. G., Davis, A. C., & Bamford, J. M. (2001). Good practice guidance for adult hearing aid fitting and services. BAAS Newsletter, 36.","journal-title":"BAAS Newsletter"},{"key":"e_1_3_2_14_1","first-page":"1","article-title":"Manual for program outline for rehabilitation of aural casualties both military and civilian","volume":"48","author":"Hughson, W.","year":"1944","unstructured":"Hughson, W., & Westlake, H. (1944). Manual for program outline for rehabilitation of aural casualties both military and civilian. Transactions - American Academy of Ophthalmology and Otolaryngology, 48(Suppl.), 1\u201315.","journal-title":"Transactions - American Academy of Ophthalmology and Otolaryngology"},{"key":"e_1_3_2_15_1","doi-asserted-by":"publisher","DOI":"10.1111\/jgs.16985"},{"key":"e_1_3_2_16_1","doi-asserted-by":"publisher","DOI":"10.4081\/audiores.2011.e24"},{"key":"e_1_3_2_17_1","doi-asserted-by":"publisher","DOI":"10.3109\/14992027.2012.736692"},{"key":"e_1_3_2_18_1","doi-asserted-by":"publisher","DOI":"10.3766\/jaaa.17103"},{"key":"e_1_3_2_19_1","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0000000000000283"},{"key":"e_1_3_2_20_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.AUD.0000120361.87401.C8"},{"key":"e_1_3_2_21_1","doi-asserted-by":"publisher","DOI":"10.1177\/108471380500900403"},{"key":"e_1_3_2_22_1","doi-asserted-by":"publisher","DOI":"10.3109\/14992027.2014.920110"},{"key":"e_1_3_2_23_1","doi-asserted-by":"publisher","DOI":"10.1002\/lio2.928"}],"container-title":["American Journal of Audiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.asha.org\/doi\/pdf\/10.1044\/2024_AJA-24-00002","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,9,3]],"date-time":"2024-09-03T20:54:55Z","timestamp":1725396895000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.asha.org\/doi\/10.1044\/2024_AJA-24-00002"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,3]]},"references-count":22,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2024,9,3]]}},"alternative-id":["10.1044\/2024_AJA-24-00002"],"URL":"https:\/\/doi.org\/10.1044\/2024_aja-24-00002","relation":{},"ISSN":["1059-0889","1558-9137"],"issn-type":[{"type":"print","value":"1059-0889"},{"type":"electronic","value":"1558-9137"}],"subject":[],"published":{"date-parts":[[2024,9,3]]}}}