{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T04:00:13Z","timestamp":1792555213906,"version":"4.5.0"},"reference-count":23,"publisher":"American Speech Language Hearing Association","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Am J Audiol"],"published-print":{"date-parts":[[2024,12,2]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>Cochlear implant (CI) recipients who listen with a hearing aid (HA) in the contralateral ear, known as bimodal listeners, demonstrate individual variability in speech recognition in noise. This variability may be due in part to differences in the processing delays of the CI and HA devices. This study investigated the influence of matching the processing delays of CI and HA devices on masked speech recognition for bimodal listeners.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Method:<\/jats:title>\n            <jats:p>Twelve postlingually deafened adult CI recipients completed a task of masked speech recognition in two listening conditions: (a) independent default CI and HA processing delays (mismatched) and (b) with their HA-specific delay applied to the CI processing delay (matched). Speech recognition was evaluated with AzBio sentences presented in a 10-talker masker at a 0 dB SNR. The target was presented from the front loudspeaker at 0\u00b0 azimuth, and the masker was co-located with the target, presented 90\u00b0 toward the CI ear, or presented 90\u00b0 toward the HA ear.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>There was a significant main effect for target-to-masker configuration, with better performance when the masker was spatially separated from the target. Better masked speech recognition was observed in the matched condition as compared to the mismatched condition.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>Bimodal listeners may experience better masked speech recognition when the processing delay of the CI is individualized to match the processing delay of the contralateral HA.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Supplemental Material:<\/jats:title>\n            <jats:p>\n              <jats:ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" ext-link-type=\"uri\" xlink:href=\"https:\/\/doi.org\/10.23641\/asha.27616845\">https:\/\/doi.org\/10.23641\/asha.27616845<\/jats:ext-link>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.1044\/2024_aja-24-00026","type":"journal-article","created":{"date-parts":[[2024,11,18]],"date-time":"2024-11-18T14:58:27Z","timestamp":1731941907000},"page":"1350-1355","source":"Crossref","is-referenced-by-count":7,"title":["Influence of Matching the Processing Delays of Cochlear Implant and Hearing Aid Devices for Bimodal Listeners on Speech Recognition in Noise"],"prefix":"10.1044","volume":"33","author":[{"ORCID":"https:\/\/orcid.org\/0009-0004-7055-994X","authenticated-orcid":false,"given":"Margaret E.","family":"Richter","sequence":"first","affiliation":[{"name":"Department of Otolaryngology\/Head &amp; Neck Surgery, School of Medicine, The University of North Carolina at Chapel Hill"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9103-0736","authenticated-orcid":false,"given":"Meredith A.","family":"Rooth","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology\/Head &amp; Neck Surgery, School of Medicine, The University of North Carolina at Chapel Hill"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4344-283X","authenticated-orcid":false,"given":"Margaret T.","family":"Dillon","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology\/Head &amp; Neck Surgery, School of Medicine, The University of North Carolina at Chapel Hill"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1310","reference":[{"key":"e_1_3_2_2_1","doi-asserted-by":"publisher","DOI":"10.1177\/23312165211016165"},{"key":"e_1_3_2_3_1","doi-asserted-by":"publisher","DOI":"10.1177\/23312165221094202"},{"key":"e_1_3_2_4_1","doi-asserted-by":"publisher","DOI":"10.1177\/23312165231171987"},{"key":"e_1_3_2_5_1","doi-asserted-by":"publisher","DOI":"10.1177\/2331216518771173"},{"key":"e_1_3_2_6_1","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0000000000000864"},{"key":"e_1_3_2_7_1","doi-asserted-by":"publisher","DOI":"10.1159\/000531262"},{"key":"e_1_3_2_8_1","doi-asserted-by":"publisher","DOI":"10.1177\/2331216520945524"},{"key":"e_1_3_2_9_1","doi-asserted-by":"publisher","DOI":"10.1044\/2022_AJA-21-00123"},{"key":"e_1_3_2_10_1","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0000000000000548"},{"key":"e_1_3_2_11_1","doi-asserted-by":"publisher","DOI":"10.1044\/1092-4388(2007\/058)"},{"key":"e_1_3_2_12_1","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0000000000000163"},{"key":"e_1_3_2_13_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00405-021-06899-y"},{"key":"e_1_3_2_14_1","unstructured":"Minimum Speech Test Battery (MSTB) for Adult Cochlear Implant Users 2011. (2011). https:\/\/www.auditorypotential.com\/MSTBfiles\/MSTBManual2011-06-20%20.pdf [PDF]"},{"key":"e_1_3_2_15_1","doi-asserted-by":"publisher","DOI":"10.1177\/23312165221108259"},{"key":"e_1_3_2_16_1","article-title":"Effect of a processing delay between direct and delayed sound in simulated open fit hearing aids on speech intelligibility in noise","volume":"17","author":"Roth S.","year":"2023","unstructured":"Roth, S., M\u00fcller, F.-U., Angermeier, J., Hemmert, W., & Zirn, S. (2023). Effect of a processing delay between direct and delayed sound in simulated open fit hearing aids on speech intelligibility in noise. Frontiers in Neuroscience, 17, Article 1257720. https:\/\/doi.org\/10.3389\/fnins.2023.1257720","journal-title":"Frontiers in Neuroscience"},{"key":"e_1_3_2_17_1","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0000000000001763"},{"key":"e_1_3_2_18_1","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0b013e31822c2549"},{"key":"e_1_3_2_19_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10162-020-00772-1"},{"key":"e_1_3_2_20_1","doi-asserted-by":"publisher","DOI":"10.1044\/jshr.2803.455"},{"key":"e_1_3_2_21_1","doi-asserted-by":"publisher","DOI":"10.1002\/lary.30368"},{"key":"e_1_3_2_22_1","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0000000000000374"},{"key":"e_1_3_2_23_1","doi-asserted-by":"publisher","DOI":"10.1177\/2331216519843876"},{"key":"e_1_3_2_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.heares.2015.08.010"}],"container-title":["American Journal of Audiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.asha.org\/doi\/pdf\/10.1044\/2024_AJA-24-00026","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,2]],"date-time":"2024-12-02T17:31:35Z","timestamp":1733160695000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.asha.org\/doi\/10.1044\/2024_AJA-24-00026"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,2]]},"references-count":23,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2024,12,2]]}},"alternative-id":["10.1044\/2024_AJA-24-00026"],"URL":"https:\/\/doi.org\/10.1044\/2024_aja-24-00026","relation":{},"ISSN":["1059-0889","1558-9137"],"issn-type":[{"value":"1059-0889","type":"print"},{"value":"1558-9137","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,2]]}}}