{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,23]],"date-time":"2026-04-23T15:38:40Z","timestamp":1776958720978,"version":"3.51.4"},"reference-count":38,"publisher":"American Speech Language Hearing Association","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Am J Audiol"],"published-print":{"date-parts":[[2024,12,2]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>This study aimed to verify the diagnostic value of tympanometry with 226- and 1000-Hz probe tones in infants by comparing tympanometry results with the gold standard of the middle ear state assessed by myringotomy. Furthermore, clinically useful predictors for false peaked tympanograms despite the presence of middle ear fluid should be identified.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Method:<\/jats:title>\n            <jats:p>Pre-operative 226- and 1000-Hz tympanograms were retrospectively compared with intraoperative findings of the tympanic cavity after myringotomy in 111 infants (217 ears) aged \u2264 12 months. In addition to the shape of tympanograms, demographic and clinical characteristics, the results of other audiometric measurements, and the viscosity of middle ear fluid, if present, were evaluated in several subgroups.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The sensitivity and specificity of 1000-Hz tympanometry for middle ear effusion (MEE) detection were 97%\u201398% and 71%\u201384%, respectively, whereas standard tympanometry with a 226-Hz probe tone achieved a poor sensitivity of 43%\u201361% and a specificity of 81%\u201397%. Younger age, low viscosity of the middle ear fluid, and female sex were associated with an increased risk of false peaked 226-Hz tympanograms despite MEE. Furthermore, larger equivalent outer ear canal volumes were linked to false peaked 226-Hz tympanograms.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The comparison of myringotomy findings and 226- and 1000-Hz tympanometry confirms the superiority of high-frequency tympanometry in infants younger than 12 months. Although this study identified some vague predictors of potentially false peaked 226-Hz tympanograms, the assessment of the middle ear state by 226-Hz tympanometry remains unreliable in young infants.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1044\/2024_aja-24-00062","type":"journal-article","created":{"date-parts":[[2024,10,16]],"date-time":"2024-10-16T17:12:40Z","timestamp":1729098760000},"page":"1246-1256","source":"Crossref","is-referenced-by-count":2,"title":["A Comparison of 226- and 1000-Hz Probe Tone Tympanometry With Myringotomy Findings in Infants"],"prefix":"10.1044","volume":"33","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2709-0953","authenticated-orcid":false,"given":"Donata","family":"Gellrich","sequence":"first","affiliation":[{"name":"Department of Otorhinolaryngology\u2014Head and Neck Surgery, Division of Phoniatrics and Pediatric Audiology, University Hospital, Ludwig Maximilian University of Munich, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Katharina","family":"Eder","sequence":"additional","affiliation":[{"name":"Department of Otorhinolaryngology\u2014Head and Neck Surgery, Division of Phoniatrics and Pediatric Audiology, University Hospital, Ludwig Maximilian University of Munich, Germany"},{"name":"Department of Pediatric Audiology, kbo-Kinderzentrum M\u00fcnchen gemeinn\u00fctzige GmbH, Munich, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0095-5360","authenticated-orcid":false,"given":"Matthias","family":"Echternach","sequence":"additional","affiliation":[{"name":"Department of Otorhinolaryngology\u2014Head and Neck Surgery, Division of Phoniatrics and Pediatric Audiology, University Hospital, Ludwig Maximilian University of Munich, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2243-7188","authenticated-orcid":false,"given":"Moritz","family":"Gr\u00f6ger","sequence":"additional","affiliation":[{"name":"Department of Otorhinolaryngology\u2014Head and Neck Surgery, Division of Phoniatrics and Pediatric Audiology, University Hospital, Ludwig Maximilian University of Munich, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6962-9999","authenticated-orcid":false,"given":"Patrick","family":"Huber","sequence":"additional","affiliation":[{"name":"Department of Otorhinolaryngology\u2014Head and Neck Surgery, Division of Phoniatrics and Pediatric Audiology, University Hospital, Ludwig Maximilian University of Munich, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1310","reference":[{"key":"e_1_3_2_2_1","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0b013e3180dca1e5"},{"key":"e_1_3_2_3_1","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0000000000001038"},{"key":"e_1_3_2_4_1","doi-asserted-by":"publisher","DOI":"10.1201\/9780429258589"},{"key":"e_1_3_2_5_1","unstructured":"American Academy of Audiology. (2020 January 20). Clinical guidance document: Assessment of hearing in infants and young children."},{"key":"e_1_3_2_6_1","doi-asserted-by":"publisher","DOI":"10.1542\/peds.113.5.1412"},{"key":"e_1_3_2_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.anorl.2015.10.001"},{"key":"e_1_3_2_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijporl.2004.11.006"},{"key":"e_1_3_2_9_1","unstructured":"British Society of Audiology. (2013). Recommended procedure for tympanometry. https:\/\/www.thebsa.org.uk\/public-consultation-recommended-procedure-tympanometry-and-acoustic-reflex-thresholds-2\/"},{"key":"e_1_3_2_10_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0033-1351678"},{"key":"e_1_3_2_11_1","doi-asserted-by":"publisher","DOI":"10.1097\/00005537-200201000-00027"},{"key":"e_1_3_2_12_1","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0000000000000915"},{"key":"e_1_3_2_13_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00405-023-08250-z"},{"key":"e_1_3_2_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijporl.2013.05.001"},{"key":"e_1_3_2_15_1","doi-asserted-by":"publisher","DOI":"10.3109\/00206099109072866"},{"key":"e_1_3_2_16_1","doi-asserted-by":"publisher","DOI":"10.1044\/1059-0889.0103.33"},{"key":"e_1_3_2_17_1","doi-asserted-by":"publisher","DOI":"10.1001\/archotol.1970.04310040005002"},{"issue":"2","key":"e_1_3_2_18_1","first-page":"1","article-title":"Year 2019 position statement: Principles and guidelines for early hearing detection and intervention programs","volume":"4","author":"Joint Committee on Infant Hearing","year":"2019","unstructured":"Joint Committee on Infant Hearing. (2019). Year 2019 position statement: Principles and guidelines for early hearing detection and intervention programs. Journal of Early Hearing Detection and Intervention, 4(2), 1\u201344. https:\/\/doi.org\/10.15142\/fptk-b748","journal-title":"Journal of Early Hearing Detection and Intervention"},{"key":"e_1_3_2_19_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00405-022-07524-2"},{"key":"e_1_3_2_20_1","doi-asserted-by":"publisher","DOI":"10.1121\/1.407347"},{"key":"e_1_3_2_21_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003446-199610000-00002"},{"key":"e_1_3_2_22_1","doi-asserted-by":"publisher","DOI":"10.3766\/jaaa.14.1.4"},{"key":"e_1_3_2_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijporl.2011.06.008"},{"key":"e_1_3_2_24_1","doi-asserted-by":"publisher","DOI":"10.3109\/00206097409071671"},{"key":"e_1_3_2_25_1","article-title":"Hochfrequenztympanometrie in neuem licht [New role of high-frequency tympanometry]","author":"Limberger A.","year":"2006","unstructured":"Limberger, A., Bohnert, A., Lippert, K.-L., & Keilmann, A. (2006). Hochfrequenztympanometrie in neuem licht [New role of high-frequency tympanometry]. German Medical Science, Article Doc06dgppV35. http:\/\/www.egms.de\/de\/meetings\/dgpp2006\/06dgpp53.shtml","journal-title":"German Medical Science"},{"key":"e_1_3_2_26_1","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0000000000001037"},{"key":"e_1_3_2_27_1","doi-asserted-by":"publisher","DOI":"10.3109\/03005364000000021"},{"key":"e_1_3_2_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijporl.2012.01.035"},{"key":"e_1_3_2_29_1","doi-asserted-by":"publisher","DOI":"10.1542\/peds.58.2.198"},{"key":"e_1_3_2_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijporl.2014.10.041"},{"key":"e_1_3_2_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.heares.2004.05.010"},{"key":"e_1_3_2_32_1","doi-asserted-by":"publisher","DOI":"10.1044\/jshr.3504.936"},{"key":"e_1_3_2_33_1","doi-asserted-by":"publisher","DOI":"10.1177\/00034894760850S240"},{"key":"e_1_3_2_34_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.earlhumdev.2014.11.005"},{"key":"e_1_3_2_35_1","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0000000000000219"},{"key":"e_1_3_2_36_1","doi-asserted-by":"publisher","DOI":"10.1177\/01455613221086023"},{"key":"e_1_3_2_37_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijporl.2010.02.019"},{"key":"e_1_3_2_38_1","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0000000000000796"},{"key":"e_1_3_2_39_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjoto.2008.11.008"}],"container-title":["American Journal of Audiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.asha.org\/doi\/pdf\/10.1044\/2024_AJA-24-00062","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,4]],"date-time":"2024-12-04T01:31:25Z","timestamp":1733275885000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.asha.org\/doi\/10.1044\/2024_AJA-24-00062"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,2]]},"references-count":38,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2024,12,2]]}},"alternative-id":["10.1044\/2024_AJA-24-00062"],"URL":"https:\/\/doi.org\/10.1044\/2024_aja-24-00062","relation":{},"ISSN":["1059-0889","1558-9137"],"issn-type":[{"value":"1059-0889","type":"print"},{"value":"1558-9137","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,2]]}}}