{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,11]],"date-time":"2026-06-11T14:17:11Z","timestamp":1781187431483,"version":"3.54.1"},"reference-count":82,"publisher":"American Speech Language Hearing Association","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Am J Speech Lang Pathol"],"published-print":{"date-parts":[[2025,5,6]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>Ultrasound tongue imaging is a promising tool in speech-language pathology; however, little is known about the usability of ultrasound scanners for speech-language pathologists (SLPs), who typically have low familiarity with ultrasound imaging. This study looks at the usability of two ultrasound scanner models for SLPs: a Sonosite all-in-one scanner with a wired probe, and a Clarius wireless probe scanner, used with a tablet app.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Method:<\/jats:title>\n            <jats:p>Twelve SLPs and phonetics experts (all female) participated in two filmed sessions in our lab where they learned to use the two models of scanners with custom-written manuals. Each scanner was used in each session to complete a simple task including recording videos of their or the experimenter's tongue. After each use of a scanner, participants completed a modified and translated version of the System Usability Scale. The time required to complete the task was measured. Two expert judges rated the quality of the video recordings.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Participants took less time to complete the task and improved their choice of settings from the first to the second session, regardless of the scanner being used. In the usability scale, SLPs showed a higher satisfaction with the wireless tablet interface than with the all-in-one ultrasound interface. The tablet interface with the wireless scanner also allowed better choices of settings. However, in the second session, positioning of the probe was better with the all-in-one scanner, which has a smaller and lighter probe.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>For SLPs, the usability of a wireless ultrasound scanner with a mobile application seems better than that of an all-in-one scanner. However, its cumbersome probe seems to hamper probe positioning. Future studies should include a lightweight ultrasound scanner that connects via USB to a laptop or tablet and provide image interpretation training for the SLPs.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1044\/2025_ajslp-24-00293","type":"journal-article","created":{"date-parts":[[2025,4,21]],"date-time":"2025-04-21T18:40:06Z","timestamp":1745260806000},"page":"1407-1424","source":"Crossref","is-referenced-by-count":1,"title":["Usability of Two Ultrasound Tongue Imaging Devices in Speech-Language Pathology"],"prefix":"10.1044","volume":"34","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-7333-7129","authenticated-orcid":false,"given":"Isabelle","family":"Marcoux","sequence":"first","affiliation":[{"name":"Universit\u00e9 du Qu\u00e9bec \u00e0 Montr\u00e9al, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lucie","family":"M\u00e9nard","sequence":"additional","affiliation":[{"name":"Universit\u00e9 du Qu\u00e9bec \u00e0 Montr\u00e9al, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Catherine","family":"Laporte","sequence":"additional","affiliation":[{"name":"\u00c9cole de technologie Sup\u00e9rieure, Montr\u00e9al, Quebec, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1310","reference":[{"key":"e_1_3_2_2_1","doi-asserted-by":"publisher","DOI":"10.1044\/1058-0360(2007\/017)"},{"key":"e_1_3_2_3_1","doi-asserted-by":"publisher","DOI":"10.1177\/1742271X221122562"},{"issue":"3","key":"e_1_3_2_4_1","first-page":"206","article-title":"Attaining the lingual components of\/r\/with ultrasound for three adolescents with cochlear implants","volume":"34","author":"Bacsfalvi P.","year":"2010","unstructured":"Bacsfalvi, P. (2010). Attaining the lingual components of\/r\/with ultrasound for three adolescents with cochlear implants. Canadian Journal of Speech-Language Pathology and Audiology, 34(3), 206\u2013217. https:\/\/www.cjslpa.ca\/detail.php?ID=1030&lang=en","journal-title":"Canadian Journal of Speech-Language Pathology and Audiology"},{"key":"e_1_3_2_5_1","doi-asserted-by":"publisher","DOI":"10.3109\/02699206.2011.618236"},{"key":"e_1_3_2_6_1","doi-asserted-by":"publisher","DOI":"10.1080\/14417040601101037"},{"key":"e_1_3_2_7_1","doi-asserted-by":"publisher","DOI":"10.1080\/10447310802205776"},{"key":"e_1_3_2_8_1","doi-asserted-by":"publisher","DOI":"10.1044\/2021_AJSLP-20-00216"},{"key":"e_1_3_2_9_1","doi-asserted-by":"publisher","DOI":"10.1080\/02699200701801225"},{"issue":"4","key":"e_1_3_2_10_1","first-page":"169","article-title":"Exploring the use of electropalatography and ultrasound in speech habilitation","volume":"29","author":"Bernhardt B.","year":"2005","unstructured":"Bernhardt, B., Bacsfalvi, P., Gick, B., Radanov, B., & Williams, R. (2005). Exploring the use of electropalatography and ultrasound in speech habilitation. Journal of Speech-Language Pathology and Audiology, 29(4), 169\u2013182. https:\/\/cjslpa.ca\/files\/2005_JSLPA_Vol_29\/No_04_141-188\/Bernhardt_Bacsfalvi_Gick_JSLPA_2005.pdf [PDF]","journal-title":"Journal of Speech-Language Pathology and Audiology"},{"key":"e_1_3_2_11_1","doi-asserted-by":"publisher","DOI":"10.1080\/0269920031000071451"},{"key":"e_1_3_2_12_1","doi-asserted-by":"publisher","DOI":"10.3109\/02699206.2015.1127999"},{"key":"e_1_3_2_13_1","doi-asserted-by":"publisher","DOI":"10.3109\/02699206.2016.1140227"},{"key":"e_1_3_2_14_1","first-page":"189","volume-title":"Usability evaluation in industry","author":"Brooke J.","year":"1996","unstructured":"Brooke, J. (1996). SUS: A \u2018quick and dirty\u2019 usability scale. In P. W. Jordan, B. Thomas, I. L. McClelland, & B. A. Weerdmeester (Eds.), Usability evaluation in industry (pp. 189\u2013194). Taylor & Francis."},{"key":"e_1_3_2_15_1","doi-asserted-by":"publisher","DOI":"10.1075\/jslp.22051.bry"},{"key":"e_1_3_2_16_1","unstructured":"Butterfly Network. (n.d.). iQ+ ultrasound scanner [Apparatus]. https:\/\/www.butterflynetwork.com\/iq-plus"},{"issue":"3","key":"e_1_3_2_17_1","first-page":"213","article-title":"A short history of sonography in obstetrics and gynaecology","volume":"5","author":"Campbell S.","year":"2013","unstructured":"Campbell, S. (2013). A short history of sonography in obstetrics and gynaecology. Facts, Views & Vision in ObGyn, 5(3), 213\u2013229.","journal-title":"Facts, Views & Vision in ObGyn"},{"issue":"1","key":"e_1_3_2_18_1","first-page":"32","article-title":"The use of ultrasound biofeedback for improving English \/r\/","volume":"25","author":"Cavin M.","year":"2015","unstructured":"Cavin, M. (2015). The use of ultrasound biofeedback for improving English \/r\/. Working Papers of the Linguistics Circle, 25(1), 32\u201341.","journal-title":"Working Papers of the Linguistics Circle"},{"key":"e_1_3_2_19_1","unstructured":"Clarius. (n.d.). Clarius ultrasound app [Computer software]. https:\/\/play.google.com\/store\/apps\/details?id=me.clarius.clarius&hl=fr_CA"},{"key":"e_1_3_2_20_1","unstructured":"Clarius. (2017). C7 Microconvex ultrasound scanner [Apparatus]. https:\/\/clarius.com\/scanners\/c7\/"},{"key":"e_1_3_2_21_1","first-page":"27","article-title":"Ultrasound in clinical practice: What, how, why, when and where","author":"Cleland J.","year":"2023","unstructured":"Cleland, J., & Allen, J. (2023). Ultrasound in clinical practice: What, how, why, when and where? Bulletin of the Royal College of Speech and Language Therapists, Spring, 27\u201331. https:\/\/strathprints.strath.ac.uk\/84022\/","journal-title":"Bulletin of the Royal College of Speech and Language Therapists"},{"key":"e_1_3_2_22_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40814-022-01051-x"},{"key":"e_1_3_2_23_1","doi-asserted-by":"publisher","DOI":"10.1159\/000499753"},{"key":"e_1_3_2_24_1","doi-asserted-by":"publisher","DOI":"10.1044\/2018_JSLHR-S-17-0360"},{"key":"e_1_3_2_25_1","doi-asserted-by":"publisher","DOI":"10.3109\/02699206.2015.1016188"},{"key":"e_1_3_2_26_1","volume-title":"ULTRAX2020: Ultrasound technology for optimising the treatment of speech disorders: Clinicians' resource manual","author":"Cleland J.","year":"2018","unstructured":"Cleland, J., Wrench, A., Lloyd, S., & Sugden, E. (2018). ULTRAX2020: Ultrasound technology for optimising the treatment of speech disorders: Clinicians' resource manual. University of Strathclyde. https:\/\/doi.org\/10.15129\/63372"},{"key":"e_1_3_2_27_1","doi-asserted-by":"publisher","DOI":"10.1080\/02699200500114077"},{"key":"e_1_3_2_28_1","doi-asserted-by":"publisher","DOI":"10.3109\/02699206.2015.1099164"},{"key":"e_1_3_2_29_1","first-page":"81","volume-title":"9i\u00e8mes Journ\u00e9es de Phon\u00e9tique Clinique \u201cPrendre la mesure de la parole\u201d","author":"D\u00e9mosth\u00e8nes I.","year":"2023","unstructured":"D\u00e9mosth\u00e8nes, I., & M\u00e9nard, L. (2023). Utilisation de l'\u00e9chographie comme outil d'\u00e9valuation des troubles de sons de la parole (TSP) dans un contexte clinique qu\u00e9b\u00e9cois: \u00c9tude pilote sur la connaissances de l'outil et la variabilit\u00e9 des analyses [Ultrasound use as a tool for evaluating speech sound disorders (SSD) in a clinical setting in Quebec: Pilot study on tool knowledge and analysis variability]. In M. Balaguer, L. Gravellier, & J. Pinquier (Eds.), 9i\u00e8mes Journ\u00e9es de Phon\u00e9tique Clinique \u201cPrendre la mesure de la parole\u201d (pp. 81\u201383). L'institut de Recherche en Informatique de Toulouse. https:\/\/www.irit.fr\/jpc2023\/"},{"key":"e_1_3_2_30_1","doi-asserted-by":"publisher","DOI":"10.1044\/2023_JSLHR-22-00472"},{"key":"e_1_3_2_31_1","doi-asserted-by":"publisher","DOI":"10.1044\/2023_AJSLP-22-00194"},{"key":"e_1_3_2_32_1","doi-asserted-by":"publisher","DOI":"10.1177\/875647939000600203"},{"key":"e_1_3_2_33_1","doi-asserted-by":"publisher","DOI":"10.3109\/02699206.2015.1137632"},{"key":"e_1_3_2_34_1","unstructured":"Fujifilm Sonosite Inc. (n.d.). rP19x phased array transducer [Apparatus]. https:\/\/www.sonosite.com\/products\/rp19x"},{"key":"e_1_3_2_35_1","unstructured":"Fujifilm Sonosite Inc. (2017). Sonosite Edge II [Apparatus and computer software]. https:\/\/www.sonosite.com\/in\/products\/sonosite-edge-ii"},{"key":"e_1_3_2_36_1","first-page":"76","article-title":"Seeing the big picture: The use of ultrasound in treating functional speech disorders in school-aged children in a community health setting","volume":"20","author":"Furniss R.","year":"2018","unstructured":"Furniss, R., & Wenger, T. (2018). Seeing the big picture: The use of ultrasound in treating functional speech disorders in school-aged children in a community health setting. Journal of Clinical Practice in Speech-Language Pathology, 20, 76\u201382.","journal-title":"Journal of Clinical Practice in Speech-Language Pathology"},{"key":"e_1_3_2_37_1","doi-asserted-by":"publisher","DOI":"10.1080\/02699206.2020.1792996"},{"key":"e_1_3_2_38_1","doi-asserted-by":"publisher","DOI":"10.1075\/sibil.36.15gic"},{"key":"e_1_3_2_39_1","doi-asserted-by":"publisher","DOI":"10.1080\/10447318.2021.1898828"},{"key":"e_1_3_2_40_1","doi-asserted-by":"publisher","DOI":"10.1145\/1518701.1518803"},{"key":"e_1_3_2_41_1","doi-asserted-by":"publisher","DOI":"10.1080\/02699206.2024.2306468"},{"key":"e_1_3_2_42_1","doi-asserted-by":"publisher","DOI":"10.3109\/02699206.2015.1120345"},{"key":"e_1_3_2_43_1","doi-asserted-by":"publisher","DOI":"10.3109\/02699206.2015.1100684"},{"key":"e_1_3_2_44_1","doi-asserted-by":"publisher","DOI":"10.3109\/02699206.2014.956232"},{"key":"e_1_3_2_45_1","unstructured":"International Organization for Standardization. (2018). Ergonomics of human\u2013system interaction\u2014Part 11: Usability: Definitions and concepts (ISO Standard No. 9241-11:2018(en)). https:\/\/www.iso.org\/obp\/ui\/#iso:std:iso:9241:-11"},{"key":"e_1_3_2_46_1","doi-asserted-by":"publisher","DOI":"10.1044\/2021_JSLHR-20-00537"},{"key":"e_1_3_2_47_1","doi-asserted-by":"publisher","DOI":"10.1044\/1058-0360(2013\/12-0137)"},{"key":"e_1_3_2_48_1","doi-asserted-by":"publisher","DOI":"10.1044\/ssod25.2.66"},{"key":"e_1_3_2_49_1","doi-asserted-by":"publisher","DOI":"10.1080\/10447318.2018.1455307"},{"key":"e_1_3_2_50_1","doi-asserted-by":"publisher","DOI":"10.3109\/02699206.2012.734366"},{"key":"e_1_3_2_51_1","doi-asserted-by":"publisher","DOI":"10.1044\/2023_JSLHR-23-00078"},{"key":"e_1_3_2_52_1","doi-asserted-by":"publisher","DOI":"10.1044\/2022_JSLHR-22-00161"},{"key":"e_1_3_2_53_1","doi-asserted-by":"publisher","DOI":"10.3109\/02699206.2015.1056884"},{"key":"e_1_3_2_54_1","doi-asserted-by":"publisher","DOI":"10.1044\/2014_JSLHR-S-14-0034"},{"key":"e_1_3_2_55_1","doi-asserted-by":"publisher","DOI":"10.1044\/2022_AJSLP-22-00144"},{"key":"e_1_3_2_56_1","doi-asserted-by":"publisher","DOI":"10.1080\/02699206.2021.1933186"},{"key":"e_1_3_2_57_1","doi-asserted-by":"publisher","DOI":"10.3109\/02699206.2015.1079247"},{"key":"e_1_3_2_58_1","doi-asserted-by":"publisher","DOI":"10.1080\/13682820701449943"},{"key":"e_1_3_2_59_1","unstructured":"Ordre des orthophonistes et audiologistes du Qu\u00e9bec. (2023). Rapport annuel 2022\u20132023. https:\/\/www.ooaq.qc.ca\/media\/sbyplsud\/ooaq_ra_2022-2023.pdf [PDF]"},{"key":"e_1_3_2_60_1","unstructured":"Philips. (n.d.). Lumify ultrasound scanner [Apparatus]. https:\/\/www.philips.ca\/healthcare\/sites\/lumify"},{"key":"e_1_3_2_61_1","doi-asserted-by":"publisher","DOI":"10.1044\/1058-0360(2013\/12-0139)"},{"key":"e_1_3_2_62_1","doi-asserted-by":"publisher","DOI":"10.1044\/2019_JSLHR-19-00060"},{"key":"e_1_3_2_63_1","doi-asserted-by":"publisher","DOI":"10.1044\/2017_AJSLP-16-0232"},{"key":"e_1_3_2_64_1","doi-asserted-by":"publisher","DOI":"10.3389\/fnhum.2016.00440"},{"key":"e_1_3_2_65_1","doi-asserted-by":"publisher","DOI":"10.1111\/1460-6984.12259"},{"key":"e_1_3_2_66_1","doi-asserted-by":"publisher","DOI":"10.1044\/2017_AJSLP-16-0155"},{"key":"e_1_3_2_67_1","doi-asserted-by":"publisher","DOI":"10.3109\/02699206.2015.1052563"},{"key":"e_1_3_2_68_1","doi-asserted-by":"publisher","DOI":"10.3791\/55123"},{"key":"e_1_3_2_69_1","doi-asserted-by":"publisher","DOI":"10.1044\/2018_JSLHR-S-17-0441"},{"key":"e_1_3_2_70_1","doi-asserted-by":"publisher","DOI":"10.1044\/2019_AJSLP-18-0261"},{"key":"e_1_3_2_71_1","doi-asserted-by":"publisher","DOI":"10.1044\/2014_JSLHR-S-14-0031"},{"key":"e_1_3_2_72_1","doi-asserted-by":"publisher","DOI":"10.3109\/02699206.2015.1135477"},{"key":"e_1_3_2_73_1","volume-title":"Articulation therapy for children with cleft palate using visual articulatory models and ultrasound biofeedback [Paper presentation]","author":"Roxburgh Z.","year":"2015","unstructured":"Roxburgh, Z., Scobbie, J. M., & Cleland, J. (2015, August 10\u201314). Articulation therapy for children with cleft palate using visual articulatory models and ultrasound biofeedback [Paper presentation]. 18th International Congress of Phonetic Sciences (ICPhS), Glasgow, Scotland."},{"key":"e_1_3_2_74_1","doi-asserted-by":"publisher","DOI":"10.1016\/B978-0-12-384968-7.00008-4"},{"key":"e_1_3_2_75_1","unstructured":"Seemore. (n.d.). PI 7.5 MHz speech language pathology 99-5544 (CAN) [Apparatus]. https:\/\/seemore.ca\/portable-ultrasound-products\/pi-7-5-mhz-speech-language-pathology-99-5544-can\/"},{"key":"e_1_3_2_76_1","doi-asserted-by":"publisher","DOI":"10.1097\/00004424-198501000-00022"},{"key":"e_1_3_2_77_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcomdis.2016.10.003"},{"key":"e_1_3_2_78_1","doi-asserted-by":"publisher","DOI":"10.1080\/10489223.2021.1910266"},{"key":"e_1_3_2_79_1","doi-asserted-by":"publisher","DOI":"10.1080\/02699206.2021.1966101"},{"key":"e_1_3_2_80_1","doi-asserted-by":"publisher","DOI":"10.1111\/1460-6984.12478"},{"key":"e_1_3_2_81_1","unstructured":"Telemed. (n.d.-a). MicrUS pro ultrasound scanner [Apparatus]. https:\/\/www.telemedultrasound.com\/en\/micrus-pro-scanner\/"},{"key":"e_1_3_2_82_1","unstructured":"Telemed. (n.d.-b). MicrUS ultrasound scanner [Apparatus]. https:\/\/www.telemedultrasound.com\/en\/micrus-scanner\/"},{"key":"e_1_3_2_83_1","doi-asserted-by":"publisher","DOI":"10.2307\/30036540"}],"container-title":["American Journal of Speech-Language Pathology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.asha.org\/doi\/pdf\/10.1044\/2025_AJSLP-24-00293","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,6]],"date-time":"2025-05-06T22:21:41Z","timestamp":1746570101000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.asha.org\/doi\/10.1044\/2025_AJSLP-24-00293"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,6]]},"references-count":82,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025,5,6]]}},"alternative-id":["10.1044\/2025_AJSLP-24-00293"],"URL":"https:\/\/doi.org\/10.1044\/2025_ajslp-24-00293","relation":{},"ISSN":["1058-0360","1558-9110"],"issn-type":[{"value":"1058-0360","type":"print"},{"value":"1558-9110","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,6]]}}}