{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,19]],"date-time":"2026-03-19T22:52:14Z","timestamp":1773960734947,"version":"3.50.1"},"reference-count":59,"publisher":"American Speech Language Hearing Association","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Speech Lang Hear Res"],"published-print":{"date-parts":[[2026,2,12]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>Glottal adjustments and vocal fold oscillations change with the vocal intensity, pitch, and quality. Therefore, capturing and recording vocal sounds during laryngoscopy is desirable. Here, we show how camera-mounted or endoscope-mounted microphones can be comfortably used to maintain a reasonably stable mouth-to-microphone (MTM) distance and obtain reproducible acoustic measures of voice during rigid laryngoscopy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Method:<\/jats:title>\n                    <jats:p>We took advantage of recently obtained data on the depth of insertion of rigid laryngoscopes into the oral cavity in adult male and female subjects. Using this as a reference, we offer an empirical formula for determining the representative MTM distance in adults for 90\u00b0 and 70\u00b0 rigid laryngoscopes to which a microphone is fixed. The uncertainty in sound pressure level (SPL) due to inter-individual variations in laryngoscope insertion was determined using standard equations for sound radiation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>When microphones are mounted on the camera head or on the laryngoscope at positions 15\u201340 cm from the laryngoscope tip, the resulting representative MTM distances range from 5 to 33 cm. Once the representative MTM distances exceed 9 cm, the expected inherent SPL inaccuracy of the setup is less than \u00b12 dB, and the expected average male-to-female SPL differences are below 1 dB with 95% confidence.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>When the vocal sound is captured using a microphone fixed to a rigid laryngoscope at an MTM distance greater than 9 cm, the influence of inter-individual differences in laryngoscope insertion on the acoustic voice signal can be neglected. To minimize the influence of ambient noise and room acoustics, MTM distances greater than 30 cm are not recommended. Calibration ensures SPL accuracy and reproducibility.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1044\/2025_jslhr-25-00580","type":"journal-article","created":{"date-parts":[[2026,1,9]],"date-time":"2026-01-09T17:31:16Z","timestamp":1767979876000},"page":"417-429","source":"Crossref","is-referenced-by-count":0,"title":["Toward Reproducible Acoustic Voice Measurements During Laryngeal Videoendoscopy, With Emphasis on Microphones Mounted on Cameras and Rigid Laryngoscopes"],"prefix":"10.1044","volume":"69","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5095-7415","authenticated-orcid":false,"given":"Jan G.","family":"\u0160vec","sequence":"first","affiliation":[{"name":"Voice Research Lab, Department of Experimental Physics, Faculty of Sciences, Palack\u00fd University Olomouc, Czech Republic"},{"name":"Voice and Hearing Center Prague, Medical Healthcom, Ltd., Czech Republic"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4985-4547","authenticated-orcid":false,"given":"Dominika","family":"Val\u00e1\u0161kov\u00e1","sequence":"additional","affiliation":[{"name":"Voice Research Lab, Department of Experimental Physics, Faculty of Sciences, Palack\u00fd University Olomouc, Czech Republic"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"1310","reference":[{"key":"e_1_3_2_2_1","volume-title":"ANSI\/ASA S1.4-2014\/Part 1: American National Standard Electroacoustics\u2014Sound level meters\u2014Part 1: Specifications","author":"American National Standards Institute","year":"2014","unstructured":"American National Standards Institute. (2014). ANSI\/ASA S1.4-2014\/Part 1: American National Standard Electroacoustics\u2014Sound level meters\u2014Part 1: Specifications. Acoustical Society of America."},{"key":"e_1_3_2_3_1","doi-asserted-by":"publisher","DOI":"10.1121\/1.5027816"},{"key":"e_1_3_2_4_1","doi-asserted-by":"publisher","DOI":"10.1121\/1.4908236"},{"key":"e_1_3_2_5_1","volume-title":"Audio Engineering Society Convention 144","author":"Brandner M.","year":"2018","unstructured":"Brandner, M., Frank, M., & Rudrich, D. (2018). Dirpat\u2014Database and viewer of 2D\/3D directivity patterns of sound sources and receivers. In Audio Engineering Society Convention 144. Audio Engineering Society. http:\/\/www.aes.org\/e-lib\/browse.cfm?elib=19538"},{"issue":"3","key":"e_1_3_2_6_1","first-page":"103","article-title":"Recording the operatic voice for acoustic analysis","volume":"30","author":"Cabrera D.","year":"2002","unstructured":"Cabrera, D., Davis, P., Barnes, J., Jacobs, M., & Bell, D. (2002). Recording the operatic voice for acoustic analysis. Acoustics Australia, 30(3), 103\u2013108.","journal-title":"Acoustics Australia"},{"key":"e_1_3_2_7_1","volume-title":"Detailed directivity of sound fields around human talkers [Technical report]","author":"Chu W. T.","year":"2002","unstructured":"Chu, W. T., & Warnock, A. C. C. (2002). Detailed directivity of sound fields around human talkers [Technical report]. Institute for Research in Construction, National Research Council of Canada."},{"key":"e_1_3_2_8_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0264981"},{"key":"e_1_3_2_9_1","doi-asserted-by":"publisher","DOI":"10.3390\/acoustics7010013"},{"key":"e_1_3_2_10_1","doi-asserted-by":"publisher","DOI":"10.1044\/2015_JSLHR-S-14-0253"},{"key":"e_1_3_2_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvoice.2004.07.003"},{"key":"e_1_3_2_12_1","doi-asserted-by":"publisher","DOI":"10.1159\/000093184"},{"key":"e_1_3_2_13_1","doi-asserted-by":"publisher","DOI":"10.1121\/1.1915975"},{"key":"e_1_3_2_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvoice.2020.12.044"},{"key":"e_1_3_2_15_1","first-page":"35","volume-title":"Master handbook of Acoustics","author":"Everest F. A.","year":"2021","unstructured":"Everest, F. A., & Pohlmann, K. C. (2021a). Sound in the free field. In Master handbook of Acoustics (7th ed., pp. 35\u201341). McGraw Hill.","edition":"7"},{"key":"e_1_3_2_16_1","volume-title":"Master handbook of acoustics","author":"Everest F. A.","year":"2021","unstructured":"Everest, F. A., & Pohlmann, K. C. (2021b). Master handbook of acoustics (4th ed.). McGraw Hill.","edition":"4"},{"key":"e_1_3_2_17_1","doi-asserted-by":"publisher","DOI":"10.1121\/1.427148"},{"key":"e_1_3_2_18_1","doi-asserted-by":"publisher","DOI":"10.1121\/1.1907972"},{"key":"e_1_3_2_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.bspc.2021.102426"},{"key":"e_1_3_2_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjoto.2020.102878"},{"key":"e_1_3_2_21_1","doi-asserted-by":"publisher","DOI":"10.1121\/1.396366"},{"key":"e_1_3_2_22_1","volume-title":"Acoustics and psychoacoustics","author":"Howard D. M.","year":"2009","unstructured":"Howard, D. M., & Angus, J. A. S. (2009). Acoustics and psychoacoustics (4th ed.). Focal Press, Elsevier.","edition":"4"},{"key":"e_1_3_2_23_1","unstructured":"International Electrotechnical Commission. (2013). IEC 61672-1:2013 Electroacoustics\u2014Sound level meters\u2014Part 1: Specification."},{"key":"e_1_3_2_24_1","unstructured":"International Organization for Standardization. (2003). ISO 9921:2003(E) Ergonomics\u2014 Assessment of speech communication."},{"key":"e_1_3_2_25_1","unstructured":"International Organization for Standardization. (2008). ISO\/IEC Guide 98-3:2008. Uncertainty of measurement -- Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)."},{"key":"e_1_3_2_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvoice.2010.04.004"},{"key":"e_1_3_2_27_1","first-page":"2197","volume-title":"In Proceedings of the Annual Conference of the International Speech Communication Association,","volume":"3","author":"Kawahara H.","year":"2021","unstructured":"Kawahara, H., Yatabe, K., Sakakibara, K. I., Mizumachi, M., Morise, M., Banno, H., & Irino, T. (2021). Interactive and real-time acoustic measurement tools for speech data acquisition and presentation: Application of an extended member of time stretched pulses. In Proceedings of the Annual Conference of the International Speech Communication Association, 3, 2197\u20132198. https:\/\/www.isca-archive.org\/interspeech_2021\/kawahara21b_interspeech.html#"},{"key":"e_1_3_2_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvoice.2021.01.005"},{"key":"e_1_3_2_29_1","volume-title":"Fundamentals of acoustics","author":"Kinsler L. E.","year":"2000","unstructured":"Kinsler, L. E., Frey, A. R., Coppens, A. B., & Sanders, J. V. (2000). Fundamentals of acoustics (4th ed.). Wiley.","edition":"4"},{"key":"e_1_3_2_30_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-93149-0"},{"key":"e_1_3_2_31_1","doi-asserted-by":"publisher","DOI":"10.1044\/2018_JSLHR-S-17-0472"},{"key":"e_1_3_2_32_1","volume-title":"Room acoustics","author":"Kuttruff H.","year":"2000","unstructured":"Kuttruff, H. (2000). Room acoustics. Elsevier Science Publishers\/Spon Press."},{"key":"e_1_3_2_33_1","doi-asserted-by":"publisher","DOI":"10.1097\/00005537-200012000-00028"},{"key":"e_1_3_2_34_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvoice.2022.02.014"},{"key":"e_1_3_2_35_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00432-023-05543-y"},{"key":"e_1_3_2_36_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvoice.2016.07.023"},{"key":"e_1_3_2_37_1","doi-asserted-by":"publisher","DOI":"10.1121\/1.3662061"},{"key":"e_1_3_2_38_1","doi-asserted-by":"publisher","DOI":"10.1177\/000348941212100510"},{"key":"e_1_3_2_39_1","doi-asserted-by":"publisher","DOI":"10.1121\/1.4725963"},{"key":"e_1_3_2_40_1","doi-asserted-by":"publisher","DOI":"10.1044\/2018_AJSLP-17-0009"},{"key":"e_1_3_2_41_1","unstructured":"Pedersen M. F. (1997). Biological development and the normal voice in puberty (Vol. D 401) [Doctoral dissertation University of Oulu]."},{"key":"e_1_3_2_42_1","doi-asserted-by":"publisher","DOI":"10.1121\/10.0005401"},{"key":"e_1_3_2_43_1","doi-asserted-by":"publisher","DOI":"10.1121\/10.0024878"},{"key":"e_1_3_2_44_1","doi-asserted-by":"publisher","DOI":"10.1159\/000265703"},{"key":"e_1_3_2_45_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2273.1996.tb01079.x"},{"key":"e_1_3_2_46_1","doi-asserted-by":"publisher","DOI":"10.1121\/1.4904538"},{"key":"e_1_3_2_47_1","doi-asserted-by":"publisher","DOI":"10.1044\/1058-0360(2010\/09-0091)"},{"key":"e_1_3_2_48_1","doi-asserted-by":"publisher","DOI":"10.1044\/2017_JSLHR-S-17-0095"},{"key":"e_1_3_2_49_1","doi-asserted-by":"publisher","DOI":"10.1177\/000348940711600303"},{"key":"e_1_3_2_50_1","volume-title":"Principles of voice production (second printing)","author":"Titze I. R.","year":"2000","unstructured":"Titze, I. R. (2000). Principles of voice production (second printing). National Center for Voice and Speech."},{"key":"e_1_3_2_51_1","unstructured":"Val\u00e1\u0161kov\u00e1 D. (2018). Variabilita vzd\u00e1lenosti mikrofonu od \u00fast p\u0159ipevn\u011bn\u00e9ho k laryngoskopu p\u0159i laryngoskopick\u00e9m vy\u0161et\u0159en\u00ed [Variability of a distance of a laryngoscope-attached microphone from the mouth in laryngoscopic examinations; Bachelor's thesis Palack\u00fd University Olomouc Faculty of Science Department of Biophysics]."},{"key":"e_1_3_2_52_1","unstructured":"Val\u00e1\u0161kov\u00e1 D. (2020). Hloubka vlo\u017een\u00ed laryngoskopu do \u00fast p\u0159i laryngoskopick\u00e9m vy\u0161et\u0159en\u00ed: Implikace pro sn\u00edm\u00e1n\u00ed hladiny akustick\u00e9ho tlaku mikrofonem p\u0159ipevn\u011bn\u00fdm k laryngoskopu [Depth of laryngoscope insertion in the mouth during laryngoscopic examinations: Implications for measurements of sound pressure level by a microphone attached to the laryngoscope; Master's thesis Palack\u00fd University Olomouc Faculty of Science Department of Biophysics]."},{"key":"e_1_3_2_53_1","doi-asserted-by":"publisher","DOI":"10.3390\/jcm12247560"},{"key":"e_1_3_2_54_1","doi-asserted-by":"publisher","DOI":"10.1080\/23268263.2025.2538004"},{"key":"e_1_3_2_55_1","doi-asserted-by":"publisher","DOI":"10.1121\/1.1835958"},{"key":"e_1_3_2_56_1","doi-asserted-by":"publisher","DOI":"10.1121\/1.3075589"},{"key":"e_1_3_2_57_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0892-1997(05)80129-8"},{"key":"e_1_3_2_58_1","doi-asserted-by":"publisher","DOI":"10.1097\/00005537-199603001-00001"},{"key":"e_1_3_2_59_1","doi-asserted-by":"publisher","DOI":"10.3390\/app11146284"},{"key":"e_1_3_2_60_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvoice.2015.01.009"}],"container-title":["Journal of Speech, Language, and Hearing Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.asha.org\/doi\/pdf\/10.1044\/2025_JSLHR-25-00580","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,19]],"date-time":"2026-03-19T19:59:15Z","timestamp":1773950355000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.asha.org\/doi\/10.1044\/2025_JSLHR-25-00580"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,12]]},"references-count":59,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026,2,12]]}},"alternative-id":["10.1044\/2025_JSLHR-25-00580"],"URL":"https:\/\/doi.org\/10.1044\/2025_jslhr-25-00580","relation":{},"ISSN":["1092-4388","1558-9102"],"issn-type":[{"value":"1092-4388","type":"print"},{"value":"1558-9102","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,12]]}}}