{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T14:19:06Z","timestamp":1788445146523,"version":"build-2803163510"},"reference-count":30,"publisher":"American Speech Language Hearing Association","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Am J Audiol"],"published-print":{"date-parts":[[2026,9,3]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>This study investigated whether long-term contact lens wear influences vestibulo-ocular reflex (VOR) gain and suppression across a range of stimulus frequencies. Despite frequent use of contact lenses in clinical populations, it remains unclear how optical correction affects VOR assessment outcomes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Method:<\/jats:title>\n                    <jats:p>Twelve myopic adults (four men, eight women; 21\u201325 years) who wore contact lenses at least 12 hr per day, 5 days per week, participated. VOR gain and suppression were measured using sinusoidal harmonic acceleration (SHA) rotary chair testing at 0.04\u20130.64 Hz, and VOR gain at high frequencies using the video head impulse test (vHIT). Each participant was tested twice: with and without contact lenses. Investigators also noted pupil tracking accuracy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>VOR gain increased with frequency, consistent with physiological norms. No significant differences were observed between contact lens and no\u2013contact lens conditions for VOR gain or suppression (SHA and vHIT, right and left canals). Pupil tracking was occasionally more challenging, and variability in VOR gain was higher with contact lenses.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Long-term contact lens wear does not significantly affect VOR gain or suppression. Clinicians may test patients with or without contact lenses; however, caution is advised when lenses are worn due to occasional pupil tracking difficulties and increased response variability.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1044\/2026_aja-25-00275","type":"journal-article","created":{"date-parts":[[2026,7,15]],"date-time":"2026-07-15T13:27:38Z","timestamp":1784122058000},"page":"1022-1030","source":"Crossref","is-referenced-by-count":0,"title":["Effects of Long-Term Contact Lens Use on Vestibulo-Ocular Reflex Using Rotary Chair and Video Head Impulse Testing"],"prefix":"10.1044","volume":"35","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-9845-3580","authenticated-orcid":false,"given":"Hanna","family":"Kolwyck","sequence":"first","affiliation":[{"name":"School of Communication Sciences and Disorders, University of Memphis, TN"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6580-6863","authenticated-orcid":false,"given":"Raghav H.","family":"Jha","sequence":"additional","affiliation":[{"name":"School of Communication Sciences and Disorders, University of Memphis, TN"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1310","reference":[{"key":"e_1_3_2_2_1","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-319-97858-1"},{"key":"e_1_3_2_3_1","doi-asserted-by":"publisher","DOI":"10.3109\/00016488509108591"},{"key":"e_1_3_2_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.neulet.2004.05.022"},{"key":"e_1_3_2_5_1","doi-asserted-by":"publisher","DOI":"10.1177\/2055668318773991"},{"key":"e_1_3_2_6_1","doi-asserted-by":"publisher","DOI":"10.1152\/jn.2000.83.1.38"},{"key":"e_1_3_2_7_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF00231150"},{"key":"e_1_3_2_8_1","doi-asserted-by":"publisher","DOI":"10.1523\/JNEUROSCI.22-11-j0002.2002"},{"issue":"1","key":"e_1_3_2_9_1","first-page":"159","article-title":"Adaptation to telescopic spectacles: Vestibulo-ocular reflex plasticity","volume":"30","author":"Demer J. L.","year":"1989","unstructured":"Demer, J. L., Porter F. I., Goldberg, J., Jenkins, H. A., & Schmidt, K. (1989). Adaptation to telescopic spectacles: Vestibulo-ocular reflex plasticity. Investigative Ophthalmology & Visual Science, 30(1), 159\u2013169.","journal-title":"Investigative Ophthalmology & Visual Science"},{"key":"e_1_3_2_10_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-2003-40751"},{"key":"e_1_3_2_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/0006-8993(75)90279-6"},{"key":"e_1_3_2_12_1","doi-asserted-by":"publisher","DOI":"10.3389\/fneur.2024.1365369"},{"key":"e_1_3_2_13_1","doi-asserted-by":"publisher","DOI":"10.1093\/acprof:oso\/9780195167085.001.0001"},{"key":"e_1_3_2_14_1","doi-asserted-by":"publisher","DOI":"10.1109\/TPAMI.2009.30"},{"key":"e_1_3_2_15_1","volume-title":"Eye tracking: A comprehensive guide to methods, paradigms, and measures","author":"Holmqvist K.","year":"2017","unstructured":"Holmqvist, K., & Andersson, R. (2017). Eye tracking: A comprehensive guide to methods, paradigms, and measures. Lund Eye-Tracking Research Institute."},{"key":"e_1_3_2_16_1","volume-title":"Balance function assessment and management","author":"Jacobson G. P.","year":"2021","unstructured":"Jacobson, G. P., Sheperd, N. T., Barin, K., Burkard, R. F., Janky, K., & McCaslin, D. L. (Eds.). (2021). Balance function assessment and management. Plural."},{"issue":"961","key":"e_1_3_2_17_1","first-page":"319","article-title":"Plasticity in the adult vestibulo-ocular reflex arc","volume":"278","author":"Jones G. M.","year":"1977","unstructured":"Jones, G. M., Barlow, H. B., & Gaze, R. M. (1977). Plasticity in the adult vestibulo-ocular reflex arc. Philosophical Transactions of the Royal Society of London, 278(961), 319\u2013334. https:\/\/doi.org\/10.1098\/rstb.1977.0045","journal-title":"Philosophical Transactions of the Royal Society of London"},{"key":"e_1_3_2_18_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-020-59251-5"},{"key":"e_1_3_2_19_1","doi-asserted-by":"publisher","DOI":"10.3389\/fphys.2025.1571534"},{"key":"e_1_3_2_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjoto.2014.06.003"},{"key":"e_1_3_2_21_1","doi-asserted-by":"publisher","DOI":"10.1080\/0036554021000028115"},{"key":"e_1_3_2_22_1","doi-asserted-by":"publisher","DOI":"10.1152\/jn.00729.2018"},{"key":"e_1_3_2_23_1","unstructured":"Sehizadeh M. (2005). Monocular adaptation of Vestibulo-Ocular Reflex (VOR) [Unpublished master's thesis] University of Waterloo."},{"key":"e_1_3_2_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/B978-0-444-63437-5.00009-1"},{"key":"e_1_3_2_25_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12883-015-0447-5"},{"key":"e_1_3_2_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1367-0484(97)80012-4"},{"key":"e_1_3_2_27_1","doi-asserted-by":"publisher","DOI":"10.3389\/fneur.2018.00125"},{"key":"e_1_3_2_28_1","doi-asserted-by":"publisher","DOI":"10.3758\/BF03208002"},{"key":"e_1_3_2_29_1","volume-title":"Rotational vestibular assessment","author":"Zalewski C. K.","year":"2017","unstructured":"Zalewski, C. K. (2017). Rotational vestibular assessment. Plural. https:\/\/www.pluralpublishing.com\/publications\/rotational-vestibular-assessment-1"},{"key":"e_1_3_2_30_1","doi-asserted-by":"publisher","DOI":"10.3233\/VES-200708"},{"key":"e_1_3_2_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.otc.2021.05.011"}],"container-title":["American Journal of Audiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.asha.org\/doi\/pdf\/10.1044\/2026_AJA-25-00275","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T14:00:38Z","timestamp":1788444038000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.asha.org\/doi\/10.1044\/2026_AJA-25-00275"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,3]]},"references-count":30,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,9,3]]}},"alternative-id":["10.1044\/2026_AJA-25-00275"],"URL":"https:\/\/doi.org\/10.1044\/2026_aja-25-00275","relation":{},"ISSN":["1059-0889","1558-9137"],"issn-type":[{"value":"1059-0889","type":"print"},{"value":"1558-9137","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,3]]}}}