{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T14:19:06Z","timestamp":1788445146259,"version":"build-2803163510"},"reference-count":26,"publisher":"American Speech Language Hearing Association","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Am J Audiol"],"published-print":{"date-parts":[[2026,9,3]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>Accurate hearing loss classification depends on air\u2013bone relationships; however, \u201cfalse\u201d air\u2013bone gaps (ABGs) in sensorineural hearing loss (SNHL) frequently compromise diagnostic clarity. By shifting the focus from ABG magnitude to clinical prevalence, this study uses the prevalence of clinical ABGs (\u2265 15 dB) as a primary metric to quantify diagnostic ambiguity in routine practice and to evaluate the efficacy of bone-conduction (BC) testing at frequencies where frequent false ABGs occur.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Method:<\/jats:title>\n                    <jats:p>We retrospectively analyzed audiometric data from 1,000 ears (500 adults). The analysis focused on the prevalence of clinical ABGs and ABG magnitudes across the tested frequencies, including a secondary analysis of their relationship with hearing loss severity. The clinical utility of the 250-Hz BC threshold was evaluated by examining whether audiologists relied on an isolated 250-Hz ABG when classifying hearing loss as conductive or mixed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>False ABGs in SNHL were most common at 250 Hz (43.5%) and 4000 Hz (13.9%), with an increasing severity of hearing loss. Audiologists did not rely on isolated ABG at 250 Hz to classify hearing loss as conductive, as all confirmed conductive\/mixed cases were detected by ABGs at other frequencies. At 4000 Hz, false ABGs were intensity-dependent artifacts, mainly appearing when the air-conduction thresholds were 50 dB HL.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>False ABGs often occur at 250 and 4000 Hz. Routine 250-Hz BC testing is unnecessary for most adults and lacks diagnostic value. Focusing on the 500- to 4000-Hz range and using the cross-check principle for 4000-Hz high-intensity thresholds will improve accuracy and efficiency.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1044\/2026_aja-26-00029","type":"journal-article","created":{"date-parts":[[2026,6,2]],"date-time":"2026-06-02T22:17:27Z","timestamp":1780438647000},"page":"893-902","source":"Crossref","is-referenced-by-count":0,"title":["Clinical Prevalence and Impact of False Air\u2013Bone Gaps in Clinical Audiometry: A Study of 1,000 Ears"],"prefix":"10.1044","volume":"35","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8319-7034","authenticated-orcid":false,"given":"Shai","family":"Chordekar","sequence":"first","affiliation":[{"name":"Department of Communication Disorders, Acoustics and Noise Research Lab in the Name of Laurent Levy, Ariel University, Israel"},{"name":"Ozen-Kashevet Hearing Clinic, Jerusalem, Israel"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liron","family":"Kariv","sequence":"additional","affiliation":[{"name":"Department of Communication Disorders, Ariel University, Israel"},{"name":"Audiology and Communication Disorders Unit, Assuta Ashdod Hospital, Israel"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4937-2628","authenticated-orcid":false,"given":"Nir","family":"Fink","sequence":"additional","affiliation":[{"name":"Department of Communication Disorders, Acoustics and Noise Research Lab in the Name of Laurent Levy, Ariel University, Israel"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1310","reference":[{"key":"e_1_3_2_2_1","unstructured":"American National Standards Institute. (2004). Methods for manual pure-tone threshold audiometry (ANSI\/ASA S3.21-2004 (R2019)). https:\/\/webstore.ansi.org\/standards\/asa\/ansiasas3212004r2019"},{"key":"e_1_3_2_3_1","unstructured":"American National Standards Institute. (2018). Specification for audiometers (ANSI S3.6-2018 (R2023)). https:\/\/webstore.ansi.org\/standards\/asa\/asaansis32018r2023"},{"key":"e_1_3_2_4_1","doi-asserted-by":"crossref","unstructured":"American Speech-Language-Hearing Association. (2005). Guidelines for manual pure-tone threshold audiometry. https:\/\/doi.org\/10.1044\/policy.GL2005-00014","DOI":"10.1044\/policy.GL2005-00014"},{"key":"e_1_3_2_5_1","doi-asserted-by":"publisher","DOI":"10.3109\/00016487009123382"},{"key":"e_1_3_2_6_1","unstructured":"British Society of Audiology. (2018). Recommended procedure: Pure-tone air-conduction and bone conduction threshold audiometry with and without masking. https:\/\/www.thebsa.org.uk\/guidance-and-resources\/current-guidance\/"},{"issue":"7","key":"e_1_3_2_7_1","first-page":"493","article-title":"Uses and abuses of hearing loss classification","volume":"23","author":"Clark J. G.","year":"1981","unstructured":"Clark, J. G. (1981). Uses and abuses of hearing loss classification. ASHA, 23(7), 493\u2013500.","journal-title":"ASHA"},{"key":"e_1_3_2_8_1","doi-asserted-by":"publisher","DOI":"10.1044\/jshr.1802.242"},{"key":"e_1_3_2_9_1","doi-asserted-by":"publisher","DOI":"10.1121\/1.4885771"},{"key":"e_1_3_2_10_1","doi-asserted-by":"publisher","DOI":"10.3758\/BF03193146"},{"key":"e_1_3_2_11_1","doi-asserted-by":"publisher","DOI":"10.1044\/jshd.5303.295"},{"key":"e_1_3_2_12_1","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0000000000000456"},{"key":"e_1_3_2_13_1","volume-title":"Essentials of audiology","author":"Gelfand S. A.","year":"2023","unstructured":"Gelfand, S. A., & Calandruccio, L. (Eds.). (2023). Essentials of audiology (5th ed.). Thieme. https:\/\/doi.org\/10.1055\/b000000430","edition":"5"},{"key":"e_1_3_2_14_1","volume-title":"Acoustics\u2014Reference zero for the calibration of audiometric equipment\u2014Part 3: Reference equivalent threshold vibratory force levels for pure tones and bone vibrators\u2014Amendment 1","author":"International Organization for Standardization","year":"2016","unstructured":"International Organization for Standardization. (2016). Acoustics\u2014Reference zero for the calibration of audiometric equipment\u2014Part 3: Reference equivalent threshold vibratory force levels for pure tones and bone vibrators\u2014Amendment 1. https:\/\/www.iso.org\/standard\/59759.html"},{"key":"e_1_3_2_15_1","volume-title":"Handbook of clinical audiology","author":"Katz J.","year":"2015","unstructured":"Katz, J., Chasin, M., English, K. M., Hood, L. J., & Tillery, K. L. (Eds.). (2015). Handbook of clinical audiology (7th ed.). Wolters Kluwer Health.","edition":"7"},{"key":"e_1_3_2_16_1","doi-asserted-by":"publisher","DOI":"10.3109\/03005364000000143"},{"key":"e_1_3_2_17_1","doi-asserted-by":"publisher","DOI":"10.1017\/S0022215100122881"},{"key":"e_1_3_2_18_1","doi-asserted-by":"publisher","DOI":"10.3109\/14992027.2013.792437"},{"key":"e_1_3_2_19_1","doi-asserted-by":"publisher","DOI":"10.1121\/10.0034456"},{"key":"e_1_3_2_20_1","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0000000000000246"},{"key":"e_1_3_2_21_1","doi-asserted-by":"publisher","DOI":"10.1044\/1059-0889.0302.20"},{"key":"e_1_3_2_22_1","first-page":"137","volume-title":"Advances in oto-rhino-laryngology","author":"Merchant S. N.","year":"2007","unstructured":"Merchant, S. N., Rosowski, J. J., & McKenna, M. J. (2007). Superior semicircular canal dehiscence mimicking otosclerotic hearing loss. In W. Arnold & R. H\u00e4usler (Eds.), Advances in oto-rhino-laryngology (pp. 137\u2013145). Karger. https:\/\/doi.org\/10.1159\/000098790"},{"key":"e_1_3_2_23_1","doi-asserted-by":"publisher","DOI":"10.1097\/AUD.0000000000000873"},{"key":"e_1_3_2_24_1","doi-asserted-by":"publisher","DOI":"10.3109\/03005368009078908"},{"key":"e_1_3_2_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.heares.2025.109488"},{"key":"e_1_3_2_26_1","doi-asserted-by":"publisher","DOI":"10.4103\/indianjotol.indianjotol_14_23"},{"key":"e_1_3_2_27_1","doi-asserted-by":"publisher","DOI":"10.4103\/indianjotol.INDIANJOTOL_99_19"}],"container-title":["American Journal of Audiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.asha.org\/doi\/pdf\/10.1044\/2026_AJA-26-00029","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T14:00:43Z","timestamp":1788444043000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.asha.org\/doi\/10.1044\/2026_AJA-26-00029"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,3]]},"references-count":26,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,9,3]]}},"alternative-id":["10.1044\/2026_AJA-26-00029"],"URL":"https:\/\/doi.org\/10.1044\/2026_aja-26-00029","relation":{},"ISSN":["1059-0889","1558-9137"],"issn-type":[{"value":"1059-0889","type":"print"},{"value":"1558-9137","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,3]]}}}