{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T19:52:13Z","timestamp":1792785133888,"version":"4.5.0"},"reference-count":38,"publisher":"American Speech Language Hearing Association","funder":[{"name":"Japan Society for the Promotion of Science","award":["KAKENHI Grant 20K03054"],"award-info":[{"award-number":["KAKENHI Grant 20K03054"]}],"id":[{"id":"https:\/\/ror.org\/00hhkn466","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Am J Audiol"],"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>This study aimed to examine how loudspeaker configuration influences the evaluation of personally worn remote microphone (RM) systems under a single signal-to-noise ratio (SNR) condition.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Method:<\/jats:title>\n                    <jats:p>This study included 10 school-aged children with hearing loss who used hearing devices and RM systems. Speech recognition was assessed using a Japanese monosyllabic word test at a nominal SNR of \u22125 dB. Three loudspeaker configurations were tested: unilateral noise at 45\u00b0, unilateral noise at 0\u00b0, and bilateral uncorrelated noise at \u00b145\u00b0. Each condition was evaluated under microphone only (MIC) and RM input modes. Speech recognition accuracy was analyzed using a generalized linear mixed-effects model, with input condition and loudspeaker configuration as fixed effects and participant and word items as random effects.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>The use of RM significantly increased the probability of correct speech recognition across all loudspeaker configurations. RM performance was consistent across configurations, with no significant interaction between input condition and loudspeaker configuration.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>RM systems provided a relatively consistent benefit in speech recognition across different loudspeaker configurations. Meanwhile, speech recognition with MIC input was highly sensitive to noise arrangement. Therefore, the effectiveness of RM systems is best characterized by their ability to stabilize performance under adverse listening conditions rather than by condition-specific enhancement. A unilateral 45\u00b0 noise configuration appears to provide a practical and feasible setup for clinical RM evaluation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Supplemental Material:<\/jats:title>\n                    <jats:p>\n                      <jats:ext-link xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" ext-link-type=\"uri\" xlink:href=\"https:\/\/doi.org\/10.23641\/asha.34113570\">https:\/\/doi.org\/10.23641\/asha.34113570<\/jats:ext-link>\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1044\/2026_aja-26-00046","type":"journal-article","created":{"date-parts":[[2026,10,19]],"date-time":"2026-10-19T17:07:47Z","timestamp":1792429667000},"page":"1-13","source":"Crossref","is-referenced-by-count":0,"title":["Effects of Loudspeaker Configuration on Speech-in-Noise Evaluation of Remote Microphone Systems"],"prefix":"10.1044","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-6132-0349","authenticated-orcid":false,"given":"Shigehiro","family":"Oohara","sequence":"first","affiliation":[{"name":"Department of Speech, Language, and Hearing Sciences, School of Rehabilitation Sciences, Seirei Christopher University, Hamamatsu, Shizuoka, Japan"},{"name":"Nanohana Day Care Center for Children with Impaired Hearing, Toyota Municipal Child Development Center, Aichi, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eiko","family":"Hirota","sequence":"additional","affiliation":[{"name":"University of Tsukuba, Bunkyo-ku, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomomi","family":"Oohara","sequence":"additional","affiliation":[{"name":"Nanohana Day Care Center for Children with Impaired Hearing, Toyota Municipal Child Development Center, Aichi, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"1310","published-online":{"date-parts":[[2026,10,19]]},"reference":[{"key":"e_1_3_2_2_1","unstructured":"American Academy of Audiology. (2011). Clinical practice guidelines: Remote microphone hearing assistance technologies for children and youth from birth to 21 years. https:\/\/www.audiology.org\/practice-guideline\/clinical-practice-guidelines-remote-microphone-hearing-assistance-technologies-for-children-and-youth-from-birth-to-21-years\/"},{"key":"e_1_3_2_3_1","doi-asserted-by":"publisher","DOI":"10.1044\/0161-1461(2004\/017)"},{"key":"e_1_3_2_4_1","first-page":"14","article-title":"Benefit of S\/N enhancing devices to speech perception of children listening in a typical classroom with hearing aids or a cochlear implant","volume":"12","author":"Anderson K. L.","year":"2005","unstructured":"Anderson, K. L., Goldstein, H., Colodzin, L., & Iglehart, F. (2005). Benefit of S\/N enhancing devices to speech perception of children listening in a typical classroom with hearing aids or a cochlear implant. Journal of Educational Audiology, 12, 14\u201328. https:\/\/www.edaud.org\/assets\/docs\/2-article-05.pdf [PDF]","journal-title":"Journal of Educational Audiology"},{"key":"e_1_3_2_5_1","doi-asserted-by":"publisher","DOI":"10.1179\/1557069X12Y.0000000003"},{"key":"e_1_3_2_6_1","doi-asserted-by":"publisher","DOI":"10.1055\/s-0043-1770155"},{"key":"e_1_3_2_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.tree.2008.10.008"},{"key":"e_1_3_2_8_1","first-page":"11","article-title":"Behavioral verification of programmable FM advantage settings","volume":"17","author":"Bondurant L.","year":"2011","unstructured":"Bondurant, L., & Thibodeau, L. (2011). Behavioral verification of programmable FM advantage settings. Journal of Educational Audiology, 17, 11\u201322.","journal-title":"Journal of Educational Audiology"},{"key":"e_1_3_2_9_1","doi-asserted-by":"publisher","DOI":"10.1121\/1.3523295"},{"key":"e_1_3_2_10_1","first-page":"105","volume-title":"Children with hearing loss: Developing listening and talking from birth to six","author":"Cole E. B.","year":"2019","unstructured":"Cole, E. B., & Flexer, C. (2019). Hearing aids, cochlear implants, and remote microphone (RM) systems. In E. B. Cole & C. Flexer (Eds.), Children with hearing loss: Developing listening and talking from birth to six (4th ed., pp. 105\u2013158). Plural.","edition":"4"},{"issue":"4","key":"e_1_3_2_11_1","first-page":"291","article-title":"An update of classroom acoustics for children with hearing impairment","volume":"96","author":"Crandell C. C.","year":"1994","unstructured":"Crandell, C. C., & Smaldino, J. J. (1994). An update of classroom acoustics for children with hearing impairment. Volta Review, 96(4), 291\u2013306.","journal-title":"Volta Review"},{"key":"e_1_3_2_12_1","doi-asserted-by":"publisher","DOI":"10.1375\/audi.23.1.52.31096"},{"issue":"5","key":"e_1_3_2_13_1","first-page":"16","article-title":"Classroom acoustic accessibility: A brain-based perspective","volume":"16","author":"Flexer C.","year":"2009","unstructured":"Flexer, C., & Rollow, J. (2009). Classroom acoustic accessibility: A brain-based perspective. Volta Voices, 16(5), 16\u201318.","journal-title":"Volta Voices"},{"key":"e_1_3_2_14_1","doi-asserted-by":"publisher","DOI":"10.1177\/10538151211025210"},{"key":"e_1_3_2_15_1","unstructured":"Individuals with Disabilities Education Act. (2004). U.S.C. \u00a7 1400."},{"key":"e_1_3_2_16_1","volume-title":"Practical methods for hearing assessment","author":"Japan Audiology Society","year":"2024","unstructured":"Japan Audiology Society (Ed.). (2024). Practical methods for hearing assessment (5th ed.). Nanzando.","edition":"5"},{"key":"e_1_3_2_17_1","unstructured":"Japanese Ministry of Education Culture Sports Science and Technology. (2017). Course of study for elementary schools. https:\/\/www.mext.go.jp\/content\/20230120-mxt_kyoiku02-100002604_01.pdf [PDF]"},{"key":"e_1_3_2_18_1","unstructured":"Japanese Ministry of Education Culture Sports Science and Technology. (2024). Special needs education data (FY2023): Part I: Statistical data. https:\/\/www.mext.go.jp\/content\/20250128-mxt_tokubetu02-000039998-2.pdf [PDF]"},{"issue":"2","key":"e_1_3_2_19_1","first-page":"1","article-title":"Year 2019 position statement: Principles and guidelines for early hearing detection and intervention programs","volume":"4","author":"Joint Committee on Infant Hearing","year":"2019","unstructured":"Joint Committee on Infant Hearing. (2019). Year 2019 position statement: Principles and guidelines for early hearing detection and intervention programs. Journal of Early Hearing Detection and Intervention, 4(2), 1\u201344. https:\/\/doi.org\/10.15142\/fptk-b748","journal-title":"Journal of Early Hearing Detection and Intervention"},{"issue":"1","key":"e_1_3_2_20_1","first-page":"1","article-title":"A study on installing active learning style in the elementary school: In comparison with the current class structure","volume":"7","author":"Kawamura S.","year":"2016","unstructured":"Kawamura, S., & Musashi, Y. (2016). A study on installing active learning style in the elementary school: In comparison with the current class structure. Educational Counseling Research, 7(1), 1\u20139. https:\/\/doi.org\/10.24665\/jjec.7.1_1","journal-title":"Educational Counseling Research"},{"key":"e_1_3_2_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.tins.2018.01.008"},{"key":"e_1_3_2_22_1","doi-asserted-by":"publisher","DOI":"10.3766\/jaaa.15.6.4"},{"key":"e_1_3_2_23_1","doi-asserted-by":"publisher","DOI":"10.1121\/1.4729575"},{"key":"e_1_3_2_24_1","doi-asserted-by":"publisher","DOI":"10.1121\/1.4922777"},{"key":"e_1_3_2_25_1","first-page":"16","article-title":"Background noise levels and reverberation times in old and new elementary school classrooms","volume":"14","author":"Nelson E. L.","year":"2008","unstructured":"Nelson, E. L., Smaldino, J., Erler, S., & Garstecki, D. (2008). Background noise levels and reverberation times in old and new elementary school classrooms. Journal of Educational Audiology, 14, 16\u201322.","journal-title":"Journal of Educational Audiology"},{"key":"e_1_3_2_26_1","doi-asserted-by":"publisher","DOI":"10.1542\/peds.2007-1422"},{"key":"e_1_3_2_27_1","doi-asserted-by":"publisher","DOI":"10.1121\/1.408469"},{"key":"e_1_3_2_28_1","volume-title":"Development of the Hearing in Noise Test for Children (HINT-C)","author":"Nilsson M. J.","year":"1996","unstructured":"Nilsson, M. J., Soli, S. D., & Gelnett, D. J. (1996). Development of the Hearing in Noise Test for Children (HINT-C). House Ear Institute."},{"key":"e_1_3_2_29_1","doi-asserted-by":"publisher","DOI":"10.4295\/audiology.63.198"},{"key":"e_1_3_2_30_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003446-199908000-00001"},{"key":"e_1_3_2_31_1","first-page":"4","article-title":"Improvements in speech recognition using cochlear implants and three types of FM systems: A meta-analytic approach","volume":"15","author":"Schafer E. C.","year":"2009","unstructured":"Schafer, E. C., & Kleineck, M. P. (2009). Improvements in speech recognition using cochlear implants and three types of FM systems: A meta-analytic approach. Journal of Educational Audiology, 15, 4\u201314.","journal-title":"Journal of Educational Audiology"},{"key":"e_1_3_2_32_1","first-page":"12","article-title":"Effects of voice priority in FM systems for children with hearing aids","volume":"19","author":"Schafer E. C.","year":"2013","unstructured":"Schafer, E. C., Sanders, K., Bryant, D., Keeney, K., & Baldus, N. (2013). Effects of voice priority in FM systems for children with hearing aids. Journal of Educational Audiology, 19, 12\u201324.","journal-title":"Journal of Educational Audiology"},{"issue":"10","key":"e_1_3_2_33_1","first-page":"678","article-title":"Speech recognition abilities of adults using cochlear implants with FM systems","volume":"15","author":"Schafer E. C.","year":"2003","unstructured":"Schafer, E. C., & Thibodeau, L. M. (2003). Speech recognition abilities of adults using cochlear implants with FM systems. Journal of Educational Audiology, 15(10), 678\u2013691. https:\/\/doi.org\/10.3766\/jaaa.15.10.3","journal-title":"Journal of Educational Audiology"},{"key":"e_1_3_2_34_1","doi-asserted-by":"publisher","DOI":"10.1044\/1059-0889(2006\/015)"},{"key":"e_1_3_2_35_1","first-page":"770","volume-title":"Pediatric audiology: Diagnosis, technology, and management","author":"Schafer E. C.","year":"2019","unstructured":"Schafer, E. C., & Wolfe, J. (2019). Remote microphone technologies. In J. R. Madell, C. Flexer, & J. Wolfe (Eds.), Pediatric audiology: Diagnosis, technology, and management (pp. 770\u2013796). Thieme."},{"key":"e_1_3_2_36_1","doi-asserted-by":"publisher","DOI":"10.4295\/audiology.53.199"},{"key":"e_1_3_2_37_1","doi-asserted-by":"publisher","DOI":"10.1093\/deafed\/enab008"},{"key":"e_1_3_2_38_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.heares.2008.06.005"},{"key":"e_1_3_2_39_1","doi-asserted-by":"publisher","DOI":"10.3766\/jaaa.24.8.8"}],"container-title":["American Journal of Audiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.asha.org\/doi\/pdf\/10.1044\/2026_AJA-26-00046","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,19]],"date-time":"2026-10-19T17:07:56Z","timestamp":1792429676000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.asha.org\/doi\/10.1044\/2026_AJA-26-00046"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,19]]},"references-count":38,"alternative-id":["10.1044\/2026_AJA-26-00046"],"URL":"https:\/\/doi.org\/10.1044\/2026_aja-26-00046","relation":{},"ISSN":["1059-0889","1558-9137"],"issn-type":[{"value":"1059-0889","type":"print"},{"value":"1558-9137","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,19]]}}}