{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,7]],"date-time":"2026-02-07T13:50:19Z","timestamp":1770472219390,"version":"3.49.0"},"reference-count":10,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2002,4,27]],"date-time":"2002-04-27T00:00:00Z","timestamp":1019865600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Aliment Pharmacol Ther"],"published-print":{"date-parts":[[2002,5]]},"abstract":"<jats:sec><jats:title>Objectives:<\/jats:title><jats:p>To evaluate the safety and efficacy of two reduced dosing regimens of sodium phosphate tablets (Visicol, InKine Pharmaceutical Co. Inc., Blue Bell, PA, USA) for colon cleansing prior to colonoscopy.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods:<\/jats:title><jats:p>In a randomized, multicentre, endoscopist\u2010blinded clinical study, adults undergoing colonoscopy received either 28 tablets (42\u2003g) or 32 tablets (48\u2003g) of sodium phosphate for colon cleansing. The endoscopist used a validated four\u2010point scale to rate the overall quality of colon cleansing, as well as cleansing in the ascending colon. Adverse events were collected and evaluated.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results:<\/jats:title><jats:p>The quality of overall colon cleansing was `excellent' or `good' in 84% or more of both groups, with no significant difference between the two doses. No patient had a preparation rated as `inadequate' or required a repeat procedure. All patients were able to complete the assigned dose of tablets, and there were no deaths, serious adverse events or dropouts from the study.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions:<\/jats:title><jats:p>A reduced tablet regimen for sodium phosphate tablets, using either 28 or 32 tablets, is well tolerated and effective for colon cleansing prior to colonoscopy.<\/jats:p><\/jats:sec>","DOI":"10.1046\/j.1365-2036.2002.01259.x","type":"journal-article","created":{"date-parts":[[2003,3,11]],"date-time":"2003-03-11T03:47:15Z","timestamp":1047354435000},"page":"937-944","source":"Crossref","is-referenced-by-count":42,"title":["Safety and efficacy of two reduced dosing regimens of sodium phosphate tablets for preparation prior to colonoscopy"],"prefix":"10.1111","volume":"16","author":[{"given":"D. K.","family":"Rex","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R.","family":"Chasen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M. B.","family":"Pochapin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2002,4,27]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1067\/mge.2001.119733"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1067\/mge.2000.108480"},{"key":"e_1_2_6_4_2","first-page":"2667","article-title":"Validation of an instrument to assess colon cleansing (Abstract)","volume":"94","author":"Aronchick C","year":"1999","journal-title":"Am J Gastroenterol"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0016-5107(96)70259-6"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF02054413"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF02213131"},{"key":"e_1_2_6_8_2","first-page":"1218","article-title":"A comparison of the effectiveness and patient tolerance of oral sodium phosphate, castor oil, and standard electrolyte lavage for colonoscopy or sigmoidoscopy preparation","volume":"88","author":"Kolts BE","year":"1993","journal-title":"Am J Gastroenterol"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0016-5107(96)70287-0"},{"key":"e_1_2_6_10_2","first-page":"422","article-title":"A randomized prospective trial comparing oral sodium phosphate with standard polyethylene glycol\u2010base lavage solution (Golytely) in the preparation of patients for colonoscopy","volume":"85","author":"Vanner SJ","year":"1990","journal-title":"Am J Gastroenterol"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0016-5107(99)70192-6"}],"container-title":["Alimentary Pharmacology &amp; Therapeutics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1046%2Fj.1365-2036.2002.01259.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1046%2Fj.1365-2036.2002.01259.x","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1046\/j.1365-2036.2002.01259.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,28]],"date-time":"2023-09-28T09:41:19Z","timestamp":1695894079000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1046\/j.1365-2036.2002.01259.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2002,4,27]]},"references-count":10,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2002,5]]}},"alternative-id":["10.1046\/j.1365-2036.2002.01259.x"],"URL":"https:\/\/doi.org\/10.1046\/j.1365-2036.2002.01259.x","archive":["Portico"],"relation":{},"ISSN":["0269-2813","1365-2036"],"issn-type":[{"value":"0269-2813","type":"print"},{"value":"1365-2036","type":"electronic"}],"subject":[],"published":{"date-parts":[[2002,4,27]]}}}