{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T12:46:56Z","timestamp":1790167616452,"version":"4.1.0"},"reference-count":20,"publisher":"Wiley","issue":"8","license":[{"start":{"date-parts":[[2003,7,14]],"date-time":"2003-07-14T00:00:00Z","timestamp":1058140800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Anaesthesia"],"published-print":{"date-parts":[[2003,8]]},"abstract":"<jats:title>Summary<\/jats:title>\n                  <jats:p>Potentially hazardous noise levels are generated in the course of major orthopaedic surgery. The risk to staff is probably real but very small. We used a sound level meter to record maximum and mean levels and found peak values which exceeded 100\u2003dB(A). If sustained, there is a possibility of significant inner ear damage and perhaps permanent troublesome tinnitus, especially among elderly and already hearing\u2010impaired patients. This could be eliminated by the use of ear defenders or disposable earplugs.<\/jats:p>","DOI":"10.1046\/j.1365-2044.2003.03257.x","type":"journal-article","created":{"date-parts":[[2003,7,14]],"date-time":"2003-07-14T07:19:16Z","timestamp":1058167156000},"page":"784-787","source":"Crossref","is-referenced-by-count":42,"title":["Orthopaedic theatre noise: a potential hazard to patients"],"prefix":"10.1111","volume":"58","author":[{"given":"M. R.","family":"Nott","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P. D. B.","family":"West","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2003,7,14]]},"reference":[{"key":"e_1_2_5_2_2","first-page":"223","article-title":"Enquiry into the effects of loud sounds upon the hearing of boilermakers and others who work amid noisy surroundings","volume":"17","author":"Barr T","year":"1886","journal-title":"Transactions of the Philosophical Society of Glasgow"},{"key":"e_1_2_5_3_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1994.tb04319.x"},{"key":"e_1_2_5_4_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.bdj.4805687"},{"key":"e_1_2_5_5_2","unstructured":"ISO.Acoustics \u2013 expression of physical and subjective magnitudes of sound or noise in air ISO 131. Geneva:International Organization for Standardization 1979."},{"key":"e_1_2_5_6_2","first-page":"326","article-title":"Stapedius reflex in industrial impact noise: fatigability and role for temporary threshold shift (TTS)","volume":"12","author":"Zakrisson J\u2010E","year":"1980","journal-title":"Scandinavian Audiology"},{"key":"e_1_2_5_7_2","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1016\/S0030-6665(20)32438-5","article-title":"General auditory effects of noise","volume":"12","author":"Ward WD","year":"1979","journal-title":"Otolaryngologic Clinics of North America"},{"key":"e_1_2_5_8_2","doi-asserted-by":"publisher","DOI":"10.1017\/S0022215100093403"},{"key":"e_1_2_5_9_2","first-page":"113","article-title":"Noise\u2010induced hearing loss in orthopaedic staff","volume":"73","author":"Willett KM","year":"1991","journal-title":"Journal of Bone and Joint Surgery [British]"},{"key":"e_1_2_5_10_2","volume-title":"The Noise at Work Regulations. Health and Safety Executive","author":"HMSO.","year":"1989"},{"key":"e_1_2_5_11_2","first-page":"8","article-title":"Noise in the orthopaedic operating theatre","volume":"77","author":"Dodenhoff RM","year":"1995","journal-title":"Annals of the Royal College of Surgeons of England"},{"key":"e_1_2_5_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/0140-6736(90)90486-O"},{"key":"e_1_2_5_13_2","doi-asserted-by":"publisher","DOI":"10.3109\/00016487509124678"},{"key":"e_1_2_5_14_2","first-page":"171","volume-title":"Proceedings of the 4th International Congress on Noise as a Public Health Problem","author":"Sulkowski WJ","year":"1983"},{"key":"e_1_2_5_15_2","first-page":"185","volume-title":"Proceedings of the 4th International Congress on Noise as a Public Health Problem","author":"Rossi G","year":"1983"},{"key":"e_1_2_5_16_2","unstructured":"AlbertiPW.Noise and the ear. In:KerrAG ed.Scott\u2010Brown's Otolaryngology 6th edn. Vol.2: Adult Audiology (StephensD ed.) Oxford:Butterworths 1997."},{"key":"e_1_2_5_17_2","unstructured":"DavisA.Hearing in Adults. The Prevalence and Distribution of Hearing Impairment and Reported Hearing Disability in the MRC Institute of Hearing Research's National Study of Hearing. London:Whurr 1995."},{"key":"e_1_2_5_18_2","first-page":"20","article-title":"Case study: a word of caution","volume":"32","author":"Coles R","year":"2001","journal-title":"British Society of Audiology"},{"key":"e_1_2_5_19_2","volume-title":"Magnetic Resonance: Bioeffects, Safety, and Patient Management.","author":"Shellock FG","year":"1994"},{"key":"e_1_2_5_20_2","doi-asserted-by":"publisher","DOI":"10.1097\/00002517-199212000-00015"},{"key":"e_1_2_5_21_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.169.2.3175004"}],"container-title":["Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1046%2Fj.1365-2044.2003.03257.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1046%2Fj.1365-2044.2003.03257.x","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/associationofanaesthetists-publications.onlinelibrary.wiley.com\/doi\/pdf\/10.1046\/j.1365-2044.2003.03257.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T19:41:38Z","timestamp":1761680498000},"score":1,"resource":{"primary":{"URL":"https:\/\/associationofanaesthetists-publications.onlinelibrary.wiley.com\/doi\/10.1046\/j.1365-2044.2003.03257.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2003,7,14]]},"references-count":20,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2003,8]]}},"alternative-id":["10.1046\/j.1365-2044.2003.03257.x"],"URL":"https:\/\/doi.org\/10.1046\/j.1365-2044.2003.03257.x","archive":["Portico"],"relation":{},"ISSN":["0003-2409","1365-2044"],"issn-type":[{"value":"0003-2409","type":"print"},{"value":"1365-2044","type":"electronic"}],"subject":[],"published":{"date-parts":[[2003,7,14]]}}}