{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,31]],"date-time":"2025-08-31T23:17:44Z","timestamp":1756682264078},"reference-count":17,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2001,12,20]],"date-time":"2001-12-20T00:00:00Z","timestamp":1008806400000},"content-version":"vor","delay-in-days":119,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Advanced Nursing"],"published-print":{"date-parts":[[2001,8,23]]},"abstract":"<jats:p> <jats:bold>Are auditory warnings in the intensive care unit properly adjusted?<\/jats:bold> <\/jats:p><jats:p>The purpose of this study was to determine whether auditory warnings in the intensive care unit (ICU) were properly adjusted. An intervention study (before\u2010 and\u2010after assessment) was conducted in a 12\u2010bed medical\u2010surgical ICU of an acute\u2010care teaching hospital in Barcelona, Spain. A total of 100 patients with stable haemodynamic and respiratory parameters were included. In the first 3\u2010month phase of the study, minimum and maximum alarm parameters of breathing rate, expired volume\/min, airway pressure, SaO<jats:sub>2<\/jats:sub>, arterial blood pressure and heart rate were recorded. In the second 12\u2010month phase of the study, the same alarm parameters were recorded every 4\u2003hours in the patient\u2019s medical record. In the third 3\u2010month phase of the study, alarm readings were recorded again as in the first phase. The change throughout coefficient of variation (CV) and the 95% confidence interval (CI) for each alarm were calculated. Following the intervention, there was a statistically significant improvement in alarm readings for expired volume, heart rate and systolic blood pressure, so that alarms had been more properly adjusted to the patient\u2019s real value. Nursing staff should be aware that auditory warnings in ICU stable patients are frequently set very far from suitable values. Recording of alarm parameters in the patient\u2019s medical record as a routine daily activity was an effective intervention for improving adjustment of auditory warnings.<\/jats:p>","DOI":"10.1046\/j.1365-2648.2001.01854.x","type":"journal-article","created":{"date-parts":[[2003,3,12]],"date-time":"2003-03-12T03:53:53Z","timestamp":1047441233000},"page":"402-406","source":"Crossref","is-referenced-by-count":7,"title":["Are auditory warnings in the intensive care unit properly adjusted?"],"prefix":"10.1111","volume":"35","author":[{"given":"Jos\u00e9 F.","family":"Solsona","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carmen","family":"Altaba","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elena","family":"Ma\u00fall","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Luisa","family":"Rodr\u00edguez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carmen","family":"Bosqu\u00e9","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ana","family":"Mulero","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2001,12,20]]},"reference":[{"key":"e_1_2_6_2_2","first-page":"10","article-title":"Patient\u2019s sleep in intensive care units and sleep\u2010modifying factors","volume":"11","author":"Calvete Vazquez R.","year":"2000","journal-title":"Enfermeria Intensiva"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1007\/s001340051082"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1378\/chest.105.4.1217"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1007\/s001340051078"},{"key":"e_1_2_6_6_2","unstructured":"KacmareckR.M.&HessD.(1994)Basic principles of ventilatory machinery. InPrinciples and Practice of Mechanical Ventilation(Tobin M.J. ed.) McGraw\u2010Hill Inc New York pp. 65\u2013111."},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-199406000-00017"},{"key":"e_1_2_6_8_2","unstructured":"Mart\u00edn AndresA.&Luna del CastilloJ.D.(1990)Bioestad\u00edstica para las ciencias de la salud 3rd edn. Ediciones Norma S.A. Madrid pp. 163\u2013164."},{"key":"e_1_2_6_9_2","first-page":"1108","article-title":"Essentials for ventilator\u2010alarms systems","volume":"37","author":"McIntyre N.R.","year":"1992","journal-title":"Respiratory Care"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2648.1995.21010015.x"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1080\/00140139308967986"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/0169-2607(96)01758-0"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1177\/0310057X8601400213"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.1986.tb12844.x"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/79.4.460"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1036-7314(95)70220-X"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-199704000-00010"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-200007000-00010"}],"container-title":["Journal of Advanced Nursing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1046%2Fj.1365-2648.2001.01854.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1046\/j.1365-2648.2001.01854.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,18]],"date-time":"2023-10-18T18:06:45Z","timestamp":1697652405000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1046\/j.1365-2648.2001.01854.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2001,8,23]]},"references-count":17,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2001,8,23]]}},"alternative-id":["10.1046\/j.1365-2648.2001.01854.x"],"URL":"https:\/\/doi.org\/10.1046\/j.1365-2648.2001.01854.x","archive":["Portico"],"relation":{},"ISSN":["0309-2402","1365-2648"],"issn-type":[{"value":"0309-2402","type":"print"},{"value":"1365-2648","type":"electronic"}],"subject":[],"published":{"date-parts":[[2001,8,23]]}}}