{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,10,29]],"date-time":"2023-10-29T05:40:36Z","timestamp":1698558036003},"reference-count":12,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2001,12,25]],"date-time":"2001-12-25T00:00:00Z","timestamp":1009238400000},"content-version":"vor","delay-in-days":846,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Internal Medicine"],"published-print":{"date-parts":[[1999,9]]},"abstract":"<jats:p><jats:bold>Abstract.<\/jats:bold> Andr\u00e9asson B, Wahlstr\u00f6m E, Jacobsson S, Bj\u00f6rkholm M, Samuelsson J, Birgeg\u00e5rd G, Wadenvik H, Kutti J (Medical Clinic, K\u00e4rnsjukhuset, Sk\u00f6vde; Sahlgrenska University Hospital, G\u00f6teborg; Karolinska Hospital, Stockholm; Huddinge University Hospital, Huddinge; and Akademiska Hospital, Uppsala, Sweden). The measurement of venous haematocrit in patients with polycythaemia vera. <jats:italic>J\u2003Intern\u2003Med<\/jats:italic> 1999; <jats:bold>246:<\/jats:bold> 293\u2013297.<\/jats:p><jats:p><jats:bold>Objective.<\/jats:bold> In clinical practice, patients with polycythaemia vera (PV) are monitored by measurement of venous packed cell volume (PCV). However, whereas treatment recommendations are still based upon studies in which the results were obtained with the centrifuged microhaematocrit, currently in most instances automated blood cell counters are used to calculate PCV. In a group of patients with polycythaemia we therefore compared the results obtained by the microhaematocrit method with PCV calculated by haematology analysers.<\/jats:p><jats:p><jats:bold>Design.<\/jats:bold> The study was carried out on a prospective basis. Duplicate venous blood samples were collected. The centrifuged microhaemotocrit was obtained by using an IEC Micro\u2010MB Centrifuge. Depending on different routine methods used in the participating hospitals, the blood cell counter PCV was calculated using Coulter STKS, Bayer Technicon H2 or H3.<\/jats:p><jats:p><jats:bold>Setting.<\/jats:bold> Patients were included from four Swedish university hospitals: Akademiska (Uppsala), Huddinge and Karolinska (Stockholm) and Sahlgrenska (G\u00f6teborg).<\/jats:p><jats:p><jats:bold>Subjects.<\/jats:bold> Seventy\u2010four patients with PV and 10 patients with secondary polycythaemia were included and a total of 150 duplicate blood samples were analysed from these subjects.<\/jats:p><jats:p><jats:bold>Results.<\/jats:bold> In the 150 measurements the mean blood cell counter calculated PCV was 0.448\u2003\u00b1\u20030.037; the mean for centrifuged microhaematocrit was 0.467\u2003\u00b1\u20030.037 and the difference between means was highly significant (<jats:italic>P<\/jats:italic>\u2003=\u20036.8\u2003\u00d7\u200310<jats:sup>\u201325<\/jats:sup>). The means for centrifuged haematocrit and calculated PCV differed significantly in the groups of PV patients treated with phlebotomy only, hydroxyurea or radiophosphorous (<jats:italic>P<\/jats:italic>\u2003&lt;\u20030.0001, respectively). In PV patients treated with \u03b1\u2010interferon and in patients with secondary polycythaemia the difference in means did not reach statistical significance (<jats:italic>P<\/jats:italic>\u2003=\u20030.07 and <jats:italic>P<\/jats:italic>\u2003=\u20030.13, respectively). The groups of patients with MCV\u2003&lt;80\u2003fL and \u226580\u2003fL both presented significant differences between means for calculated PCV and centrifuged haematocrit.<\/jats:p><jats:p><jats:bold>Conclusions.<\/jats:bold> If PV patients are monitored with blood cell counter calculated PCV it appears that the therapeutic goal should be to maintain the calculated PCV below 0.43, provided the local differences in calculated PCV and centrifuged haematocrit are of the same magnitude as in this study.<\/jats:p>","DOI":"10.1046\/j.1365-2796.1999.00524.x","type":"journal-article","created":{"date-parts":[[2003,3,12]],"date-time":"2003-03-12T06:10:25Z","timestamp":1047449425000},"page":"293-297","source":"Crossref","is-referenced-by-count":3,"title":["The measurement of venous haematocrit in patients with polycythaemia vera"],"prefix":"10.1111","volume":"246","author":[{"given":"B.","family":"Andr\u00e9asson","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"E.","family":"Wahlstr\u00f6m","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.","family":"Jacobsson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Bj\u00f6rkholm","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.","family":"Samuelsson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G.","family":"Birgeg\u00e5rd","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H.","family":"Wadenvik","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.","family":"Kutti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2001,12,25]]},"reference":[{"key":"e_1_2_7_2_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.0954-6820.1950.tb10111.x"},{"key":"e_1_2_7_3_2","doi-asserted-by":"publisher","DOI":"10.1002\/bjs.1800600305"},{"key":"e_1_2_7_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(78)92098-6"},{"key":"e_1_2_7_5_2","first-page":"123","article-title":"Therapeutic recommendations in polycythemia vera based on Polycythemia Vera Study Group protocol.","volume":"23","author":"Berk PD","year":"1986","journal-title":"Semin Hematol"},{"key":"e_1_2_7_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2257.1994.tb00416.x"},{"key":"e_1_2_7_7_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2257.1991.tb00284.x"},{"key":"e_1_2_7_8_2","doi-asserted-by":"publisher","DOI":"10.1093\/ajcp\/100.4.371"},{"key":"e_1_2_7_9_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2141.1972.tb03477.x"},{"key":"e_1_2_7_10_2","doi-asserted-by":"publisher","DOI":"10.1093\/ajcp\/78.5.770"},{"key":"e_1_2_7_11_2","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1093\/ajcp\/72.1.71","article-title":"Comparison of hematocrit determinations by microhematocrit and electronic particle counter.","volume":"72","author":"Penn D","year":"1979","journal-title":"Am J Clin Pathol"},{"key":"e_1_2_7_12_2","doi-asserted-by":"publisher","DOI":"10.1002\/ajh.2830050107"},{"key":"e_1_2_7_13_2","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1111\/j.1365-2257.1988.tb01172.x","article-title":"The assignment of values to fresh blood used for calibrating automated blood cell counters.","volume":"10","author":"International Council for Standardization in Haematology: expert panel on cytometry.","year":"1988","journal-title":"Clin Lab Haematol"}],"container-title":["Journal of Internal Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1046%2Fj.1365-2796.1999.00524.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1046\/j.1365-2796.1999.00524.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,28]],"date-time":"2023-10-28T17:33:47Z","timestamp":1698514427000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1046\/j.1365-2796.1999.00524.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1999,9]]},"references-count":12,"journal-issue":{"issue":"3","published-print":{"date-parts":[[1999,9]]}},"alternative-id":["10.1046\/j.1365-2796.1999.00524.x"],"URL":"https:\/\/doi.org\/10.1046\/j.1365-2796.1999.00524.x","archive":["Portico"],"relation":{},"ISSN":["0954-6820","1365-2796"],"issn-type":[{"value":"0954-6820","type":"print"},{"value":"1365-2796","type":"electronic"}],"subject":[],"published":{"date-parts":[[1999,9]]}}}