{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T17:44:47Z","timestamp":1790099087005,"version":"4.0.1"},"reference-count":12,"publisher":"Wiley","issue":"8","license":[{"start":{"date-parts":[[2001,12,20]],"date-time":"2001-12-20T00:00:00Z","timestamp":1008806400000},"content-version":"vor","delay-in-days":138,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["ANZ Journal of Surgery"],"published-print":{"date-parts":[[2001,8,4]]},"abstract":"<jats:p> <jats:bold>Background<\/jats:bold>: Identification of the internal opening is an essential step in the management of fistula\u2010in\u2010ano. The predictive accuracy of Goodsall\u2019s rule is compared with instillation of hydrogen peroxide for fistulas\u2010in\u2010ano.<\/jats:p><jats:p> <jats:bold>Methods<\/jats:bold>: Thirty\u2010five patients (32 male, three female; median age 42 years; range: 6 months\u201370 years) were studied. Hydrogen peroxide solution was injected into the external opening of the fistula track and effervescence was observed at the internal opening within the anal canal. A fistula track was either excised or incised. Setons were placed within high fistulas.<\/jats:p><jats:p> <jats:bold>Results<\/jats:bold>: There were 24 simple fistulas, compared to 11 complex fistulas (horseshoe, <jats:italic>n<\/jats:italic> = 4; abscess, <jats:italic>n<\/jats:italic> = 4). Eighteen external openings were anterior and 17 were posterior. Thirty\u2010four of 35 (97%) internal openings were identified. Only 20 internal openings were in accordance with Goodsall\u2019s rule (positive predictive value: 59%). Predictive accuracy was greater for anterior external openings (13 of 18 (72%)) versus posterior external openings (six of 17 (41%); <jats:italic>P<\/jats:italic> = 0.016). For recurrent fistulas, seven of 17 fistula tracks had an internal opening in accordance with Goodsall\u2019s rule, resulting in a positive predictive value of 41%. (Positive predictive value: anterior 67%<jats:italic>vs<\/jats:italic> posterior 12.5%; <jats:italic>P<\/jats:italic> = 0.0009.)<\/jats:p><jats:p> <jats:bold>Conclusion<\/jats:bold>: The overall predictive accuracy of Goodsall\u2019s rule was poor chiefly because of poor predictive accuracy in posterior and recurrent fistulas. The use of Goodsall\u2019s rule alone in decision\u2010making before surgical intervention is not recommended.<\/jats:p>","DOI":"10.1046\/j.1440-1622.2001.02169.x","type":"journal-article","created":{"date-parts":[[2003,3,11]],"date-time":"2003-03-11T02:47:01Z","timestamp":1047350821000},"page":"472-474","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":37,"title":["Comparison of hydrogen peroxide instillation with Goodsall\u2019s fule for fistula\u2010in\u2010ano"],"prefix":"10.1111","volume":"71","author":[{"given":"P. A. H. A.","family":"Gunawardhana","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K. I.","family":"Deen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2001,12,20]]},"reference":[{"key":"e_1_2_5_2_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF02052593"},{"key":"e_1_2_5_3_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF02054434"},{"key":"e_1_2_5_4_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1445-2197.1997.tb01911.x"},{"key":"e_1_2_5_5_2","unstructured":"GoligherJ.Fistula in ano. In: Goligher J (ed.)Surgery of the Anus Rectum and Colon 5th edn. London: Bailliere Tindall 1984; 179\u2013220."},{"key":"e_1_2_5_6_2","unstructured":"ThompsonJPS&HawleyPR.Anorectal surgery. In: Kirk RL Williamson RCN (eds)General Surgical Operations 2nd edn. Edinburgh: Churchill Livingstone 1987; 151\u201370."},{"key":"e_1_2_5_7_2","doi-asserted-by":"crossref","unstructured":"StuartTR.Fistula in ano. In: Biagio R (ed.) Techniques of Colorectal Surgery.Surg. Clin. North Am.1998;68: 1417\u201326.","DOI":"10.1016\/S0039-6109(16)44697-9"},{"key":"e_1_2_5_8_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF02239437"},{"key":"e_1_2_5_9_2","doi-asserted-by":"crossref","unstructured":"RosenL.Anorectal abscess\u2010fistula. In: Levien D (ed.) Anorectal Surgery.Surg. Clin. North Am.1998;68: 1293\u2013308.","DOI":"10.1016\/S0039-6109(16)46481-9"},{"key":"e_1_2_5_10_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF02050532"},{"key":"e_1_2_5_11_2","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1177\/0310057X9902700417","article-title":"Gas embolism produced by hydrogen peroxide abscess irrigation in an infant.","volume":"4","author":"Schwab C","year":"1999","journal-title":"Anaesth. Intensive Care"},{"key":"e_1_2_5_12_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF03010684"},{"key":"e_1_2_5_13_2","first-page":"124","article-title":"Gas embolism secondary to intraoperative use of hydrogen peroxide.","volume":"44","author":"Garcia\u2010Velaso P","year":"1997","journal-title":"Rev. Esp. Anestesiol. Reanim."}],"container-title":["ANZ Journal of Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1046%2Fj.1440-1622.2001.02169.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1046%2Fj.1440-1622.2001.02169.x","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1046\/j.1440-1622.2001.02169.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,31]],"date-time":"2023-10-31T07:33:10Z","timestamp":1698737590000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1046\/j.1440-1622.2001.02169.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2001,8,4]]},"references-count":12,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2001,8,4]]}},"alternative-id":["10.1046\/j.1440-1622.2001.02169.x"],"URL":"https:\/\/doi.org\/10.1046\/j.1440-1622.2001.02169.x","archive":["Portico"],"relation":{},"ISSN":["1445-1433","1445-2197"],"issn-type":[{"value":"1445-1433","type":"print"},{"value":"1445-2197","type":"electronic"}],"subject":[],"published":{"date-parts":[[2001,8,4]]},"assertion":[{"value":"2001-12-20","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}