{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,3]],"date-time":"2026-10-03T09:38:39Z","timestamp":1791020319818,"version":"4.1.0"},"reference-count":17,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2001,12,25]],"date-time":"2001-12-25T00:00:00Z","timestamp":1009238400000},"content-version":"vor","delay-in-days":511,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Clinical Exper Ophthalmology"],"published-print":{"date-parts":[[2000,8]]},"abstract":"<jats:title>ABSTRACT<\/jats:title><jats:p> <jats:bold>Background<\/jats:bold>: Diode laser cyclophotocoagulation (cyclodiode) is gaining acceptance as a therapy for refractory or end\u2010stage glaucoma. The aim of the study was to establish whether a reproducible dose\u2013effect relationship exists following a single standardized cyclodiode treatment to lower intraocular pressure (IOP).<\/jats:p><jats:p> <jats:bold>Methods<\/jats:bold>: This paper reports results from a longer\u2010term follow up of a trial involving the study of 30 patients with uncontrolled IOP and advanced glaucoma who were treated with a single episode of either a half or a full standardized dose of laser depending on clinical risk of phthisis and monitored for IOP control, visual acuity, postoperative inflammation and phthisis.<\/jats:p><jats:p> <jats:bold>Results<\/jats:bold>: A lowering of IOP at the final follow up was achieved in 83% of patients, with a mean follow\u2010up time of 21 months. For patients receiving a full standardized laser dose, preoperative IOP was 49.4 \u00b1 11.2 mmHg (mean \u00b1 SD) and postoperative IOP was 28.5 \u00b1 20.0 mmHg (42% reduction); 45% of patients achieved IOP &lt; 22 mmHg and 68% gained an IOP reduction &gt; 30%. For the half treatment cases, the preoperative IOP was 29.4 \u00b1 4.3 mmHg (mean \u00b1 SD) and the postoperative IOP was 18.3 \u00b1 10.0 mmHg (38% reduction); 63% of patients achieved IOP &lt; 22 mmHg and 50% gained an IOP reduction of &gt; 30%. Of 22 sighted eyes, nine (41%) recorded no change in vision; and nine (41%) lost and four (18%) gained vision. Hypotony was seen in 4\/22 (18%) of full standardized laser dose cases.<\/jats:p><jats:p> <jats:bold>Conclusion<\/jats:bold>: Longer follow\u2010up times confirm that diode laser cyclophotocoagulation is a convenient and useful therapy in the control of IOP in end\u2010stage glaucoma. Response of IOP to the laser therapy is highly variable, particularly in the neovascular glaucoma group, and it does not appear to be possible to predict an IOP outcome for an individual eye. Circumferential treatments in neovascular eyes should be avoided. Prospects for long\u2010term vision retention in end\u2010stage eyes are poor, perhaps due to progression of the underlying disease.<\/jats:p>","DOI":"10.1046\/j.1442-9071.2000.00320.x","type":"journal-article","created":{"date-parts":[[2003,3,11]],"date-time":"2003-03-11T10:56:53Z","timestamp":1047380213000},"page":"263-267","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":49,"title":["Diode laser cyclophotocoagulation: longer term follow up of a standardized treatment protocol"],"prefix":"10.1111","volume":"28","author":[{"given":"Mark J","family":"Walland","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2001,12,25]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1442-9071.1998.tb01529.x"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(92)31846-9"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.74.2.103"},{"key":"e_1_2_6_5_2","first-page":"225","article-title":"Initial experience with a new method of laser transscleral cyclophotocoagulation for ciliary ablation in severe glaucoma.","volume":"90","author":"Gaasterland D","year":"1992","journal-title":"Trans. Am. Ophthalmol. Soc."},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1007\/s003470050112"},{"key":"e_1_2_6_7_2","unstructured":"BrubakerRF.Measurement of aqueous flow by fluorophotometry. In: Ritch R Shields MB Krupin T (eds.)The Glaucomas 2nd edn. St Louis: Mosby 1996; 447\u201354."},{"key":"e_1_2_6_8_2","doi-asserted-by":"crossref","first-page":"852","DOI":"10.3928\/1542-8877-19981001-13","article-title":"Diode laser cyclophotocoagulation: Histopathology in 2 cases of clinical failure.","volume":"29","author":"Walland MJ.","year":"1998","journal-title":"Ophthalmic Surg. Lasers"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(97)30109-2"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1159\/000267395"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006982-199709000-00010"},{"key":"e_1_2_6_12_2","doi-asserted-by":"crossref","first-page":"495","DOI":"10.3928\/1542-8877-19970601-09","article-title":"Transscleral diode laser cyclophotocoagulation on autopsy eyes with abnormally thinned sclera.","volume":"28","author":"Palmer DJ","year":"1997","journal-title":"Ophthalmic Surg. Lasers"},{"key":"e_1_2_6_13_2","doi-asserted-by":"crossref","first-page":"722","DOI":"10.3928\/1542-8877-19980901-05","article-title":"Transscleral cyclophotocoagulation with the diode laser for neovascular glaucoma.","volume":"29","author":"Oguri A","year":"1998","journal-title":"Ophthalmic Surg. Lasers"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(96)30508-3"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1097\/00061198-199612000-00006"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.116.4.488"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.83.3.311"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(14)71696-4"}],"container-title":["Clinical &amp; Experimental Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1046%2Fj.1442-9071.2000.00320.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1046\/j.1442-9071.2000.00320.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,27]],"date-time":"2023-09-27T23:30:09Z","timestamp":1695857409000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1046\/j.1442-9071.2000.00320.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2000,8]]},"references-count":17,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2000,8]]}},"alternative-id":["10.1046\/j.1442-9071.2000.00320.x"],"URL":"https:\/\/doi.org\/10.1046\/j.1442-9071.2000.00320.x","archive":["Portico"],"relation":{},"ISSN":["1442-6404","1442-9071"],"issn-type":[{"value":"1442-6404","type":"print"},{"value":"1442-9071","type":"electronic"}],"subject":[],"published":{"date-parts":[[2000,8]]},"assertion":[{"value":"2001-12-25","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}