{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,26]],"date-time":"2025-11-26T16:07:20Z","timestamp":1764173240893},"reference-count":9,"publisher":"Wiley","issue":"1p2","license":[{"start":{"date-parts":[[2003,3,28]],"date-time":"2003-03-28T00:00:00Z","timestamp":1048809600000},"content-version":"vor","delay-in-days":86,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[2003,1]]},"abstract":"<jats:p> <jats:bold>BORDACHAR, P., <jats:sc>et al.: <\/jats:sc>Impact and Prevention of Far\u2010Field Sensing in Fallback Mode Switches.<\/jats:bold>\n          <jats:italic>Far\u2010field oversensing (FFOS) promoted by high atrial sensitivity and short atrial refractory periods induces false positive mode switches. We evaluated the incidence of ventricular FFOS in a population of DDD paced patients. Methods: One hundred thirty\u2010seven patients (<\/jats:italic>\n          <jats:styled-content>\n              <jats:italic>71 \u00b1 10<\/jats:italic>\n            <\/jats:styled-content>\n          <jats:italic>years, 76 men) implanted with a Talent DR pacemaker were studied. Before discharge, an analysis of internal data stored in the memories of the PM was performed by the specific software incorporated in the programmer in parallel with a 24\u2010hour Holter recording. Data were validated by a panel of experts. One and 4 months follow\u2010up was based only on the data stored in the PM memories. Results: Pacing indications were atrioventricular block<\/jats:italic>\n          <jats:styled-content>\n              <jats:italic>(n = 75)<\/jats:italic>\n            <\/jats:styled-content>\n          <jats:italic>, sinus node dysfunction<\/jats:italic>\n          <jats:styled-content>\n              <jats:italic>(n = 57)<\/jats:italic>\n            <\/jats:styled-content>\n          <jats:italic>, and other<\/jats:italic>\n          <jats:styled-content>\n              <jats:italic>(n = 5)<\/jats:italic>\n            <\/jats:styled-content>\n          <jats:italic>. Sustained far\u2010field oversensing was observed in 12\/137 patients (9%). Out of a total of 3,511 triggered mode switch episodes, FFOS accounted for 20% and 7% of a 311 days cumulative time in mode switch. Inappropriate mode switch episodes induced by far\u2010field were more numerous but shorter than episodes prompted by atrial arrhythmias. Atrial sensitivity was increased in eight patients, successfully in four. Reprogramming of the atrial refractory period<\/jats:italic>\n          <jats:styled-content>\n              <jats:italic>(156 \u00b1 11 ms)<\/jats:italic>\n            <\/jats:styled-content>\n          <jats:italic>was successful in five of six patients. Conclusions: A 9% rate of ventricular FFOS was observed in an unselected population, easily and automatically diagnosed using the internal memory function and the automatic analysis provided by the programmer. Prolongation of the atrial refractory period was more effective than resetting of the atrial sensitivity in eliminating FFOS. (PACE 2003; 26[Pt. II]:206\u2013209)<\/jats:italic> <\/jats:p>","DOI":"10.1046\/j.1460-9592.2003.00017.x","type":"journal-article","created":{"date-parts":[[2004,12,28]],"date-time":"2004-12-28T08:02:53Z","timestamp":1104220973000},"page":"206-209","source":"Crossref","is-referenced-by-count":20,"title":["Impact and Prevention of Far\u2010Field Sensing in Fallback Mode Switches"],"prefix":"10.1111","volume":"26","author":[{"given":"PIERRE","family":"BORDACHER","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"SERGE","family":"CAZEAU","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"LAURENCE","family":"GRAINDORG","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"PHILIPPE","family":"RITTER","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2003,3,28]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1988.tb04992.x"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1988.tb06271.x"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1998.tb01098.x"},{"key":"e_1_2_6_5_2","unstructured":"GarrigueS CazeauS RitterP et al.Incidence des arythmies atriales chez les patients stimul\u00e9s au long cours en mode double\u2010chambre. Archives des maladies du C\u0153ur et des Vaisseaux1996;89:873\u2013881."},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1994.tb03809.x"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1997.tb05457.x"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1996.tb03214.x"},{"key":"e_1_2_6_9_2","first-page":"15","article-title":"Clinical performances of a new mode switch function based on a statistical analysis of the atrial rhythm. Herzschrittmacher\u2010therapie & Elektro\u2010physiologie","volume":"1","author":"G\u00e9roux L","year":"1999","journal-title":"Supplement"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1460-9592.2002.00380.x"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1046%2Fj.1460-9592.2003.00017.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1046\/j.1460-9592.2003.00017.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,13]],"date-time":"2023-10-13T12:01:50Z","timestamp":1697198510000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1046\/j.1460-9592.2003.00017.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2003,1]]},"references-count":9,"journal-issue":{"issue":"1p2","published-print":{"date-parts":[[2003,1]]}},"alternative-id":["10.1046\/j.1460-9592.2003.00017.x"],"URL":"https:\/\/doi.org\/10.1046\/j.1460-9592.2003.00017.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2003,1]]}}}