{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,27]],"date-time":"2025-10-27T10:28:58Z","timestamp":1761560938921},"reference-count":17,"publisher":"Wiley","issue":"1p2","license":[{"start":{"date-parts":[[2003,3,28]],"date-time":"2003-03-28T00:00:00Z","timestamp":1048809600000},"content-version":"vor","delay-in-days":86,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[2003,1]]},"abstract":"<jats:p> <jats:bold>SZILI\u2010TOROK, T., <jats:sc>et al<\/jats:sc>.: Effects of Septal Pacing on P Wave Characteristics: The Value of Three\u2010Dimensional Echocardiography.<\/jats:bold>\n          <jats:italic>Interatrial septum (IAS) pacing has been proposed for the prevention of paroxysmal atrial fibrillation. IAS pacing is usually guided by fluoroscopy and P wave analysis. The authors have developed a new approach for IAS pacing using intracardiac echocardiography (ICE), and examined its effects on P wave characteristics. Cross\u2010sectional images are acquired during pullback of the ICE transducer from the superior vena cava into the inferior vena cava by an electrocardiogram\u2010 and respiration\u2010gated technique. The right atrium and IAS are then three\u2010dimensionally reconstructed, and the desired pacing site is selected. After lead placement and electrical testing, another three\u2010dimensional reconstruction is performed to verify the final lead position. The study included 14 patients. IAS pacing was achieved at seven suprafossal (SF) and seven infrafossal (IF) lead locations, all confirmed by three\u2010dimensional imaging. IAS pacing resulted in a significant reduction of P wave duration as compared to sinus rhythm (<\/jats:italic>\n          <jats:styled-content>\n              <jats:italic>99.7 \u00b1 18.7<\/jats:italic>\n            <\/jats:styled-content>\n          <jats:italic>vs<\/jats:italic>\n          <jats:styled-content>\n              <jats:italic>140.4 \u00b1 8.8\u2003 ms; P &lt; 0.01<\/jats:italic>\n            <\/jats:styled-content>\n          <jats:italic>). SF pacing was associated with a greater reduction of P wave duration than IF pacing (<\/jats:italic>\n          <jats:styled-content>\n              <jats:italic>56.1 \u00b1 9.9<\/jats:italic>\n            <\/jats:styled-content>\n          <jats:italic>vs<\/jats:italic>\n          <jats:styled-content>\n              <jats:italic>30.2 \u00b1 13.6\u2003 ms; P &lt; 0.01<\/jats:italic>\n            <\/jats:styled-content>\n          <jats:italic>). P wave dispersion remained unchanged during septal pacing as compared to sinus rhythm (<\/jats:italic>\n          <jats:styled-content>\n              <jats:italic>21.4 \u00b1 16.1<\/jats:italic>\n            <\/jats:styled-content>\n          <jats:italic>vs<\/jats:italic>\n          <jats:styled-content>\n              <jats:italic>13.5 \u00b1 13.9\u2003 ms; NS<\/jats:italic>\n            <\/jats:styled-content>\n          <jats:italic>). Three\u2010dimensional intracardiac echocardiography can be used to guide IAS pacing. SF pacing was associated with a greater decrease in P wave duration, suggesting that it is a preferable location to decrease interatrial conduction delay. (PACE 2003; 26[Pt. II]:253\u2013256)<\/jats:italic> <\/jats:p>","DOI":"10.1046\/j.1460-9592.2003.00027.x","type":"journal-article","created":{"date-parts":[[2004,12,28]],"date-time":"2004-12-28T08:02:53Z","timestamp":1104220973000},"page":"253-256","source":"Crossref","is-referenced-by-count":5,"title":["Effects of Septal Pacing on P Wave Characteristics: The Value of Three\u2010Dimensional Echocardiography"],"prefix":"10.1111","volume":"26","author":[{"given":"TAMAS","family":"SZILI\u2010TOROK","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"NICO","family":"BRUINING","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"MARCOEN","family":"SCHOLTEN","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"GEERT\u2010JAN","family":"KIMMAN","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"JOS","family":"ROELANDT","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"LUC","family":"JORDAENS","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2003,3,28]]},"reference":[{"key":"e_1_2_5_2_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1997.tb05431.x"},{"key":"e_1_2_5_3_2","first-page":"S155","article-title":"Multisite electrode pacing for prevention of atrial fibrillation","volume":"9","author":"Saksena S","year":"1998","journal-title":"J Cardiovasc Electrophysiol"},{"key":"e_1_2_5_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(00)00631-8"},{"key":"e_1_2_5_5_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1540-8167.2001.00912.x"},{"key":"e_1_2_5_6_2","doi-asserted-by":"publisher","DOI":"10.1023\/A:1009867305678"},{"key":"e_1_2_5_7_2","doi-asserted-by":"publisher","DOI":"10.1067\/mhj.2001.119373"},{"key":"e_1_2_5_8_2","volume-title":"Computers in Cardiology","author":"Bruining N","year":"1995"},{"key":"e_1_2_5_9_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.96.9.2944"},{"key":"e_1_2_5_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1998.tb00011.x"},{"key":"e_1_2_5_11_2","first-page":"227","article-title":"Electrophysiology of atrial fibrillation and its prevention by coronary sinus pacing","volume":"2","author":"Papageorgiou P","year":"1997","journal-title":"Semin Interv Cardiol"},{"key":"e_1_2_5_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(01)01856-2"},{"key":"e_1_2_5_13_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.102.7.736"},{"key":"e_1_2_5_14_2","first-page":"1535","article-title":"Permanent atrial resynchronization by synchronous bi\u2010atrial pacing in the preventive treatment of atrial flutter associated with high degree interatrial block","volume":"87","author":"Daubert C","year":"1994","journal-title":"Arch Mal Coeur Vaiss"},{"key":"e_1_2_5_15_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.96.9.2992"},{"key":"e_1_2_5_16_2","first-page":"S40","article-title":"Use of intracardiac echocardiography during electrophysiologic evaluation and therapy of atrial arrhythmias","volume":"9","author":"Lesh MD","year":"1998","journal-title":"J Cardiovasc Electrophysiol"},{"key":"e_1_2_5_17_2","doi-asserted-by":"publisher","DOI":"10.1136\/heart.86.5.e11"},{"key":"e_1_2_5_18_2","doi-asserted-by":"publisher","DOI":"10.1053\/eupc.2000.0147"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1046%2Fj.1460-9592.2003.00027.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1046\/j.1460-9592.2003.00027.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,13]],"date-time":"2023-10-13T11:59:44Z","timestamp":1697198384000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1046\/j.1460-9592.2003.00027.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2003,1]]},"references-count":17,"journal-issue":{"issue":"1p2","published-print":{"date-parts":[[2003,1]]}},"alternative-id":["10.1046\/j.1460-9592.2003.00027.x"],"URL":"https:\/\/doi.org\/10.1046\/j.1460-9592.2003.00027.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2003,1]]}}}