{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,8]],"date-time":"2026-05-08T17:45:34Z","timestamp":1778262334727,"version":"3.51.4"},"reference-count":11,"publisher":"Wiley","issue":"1p2","license":[{"start":{"date-parts":[[2003,3,28]],"date-time":"2003-03-28T00:00:00Z","timestamp":1048809600000},"content-version":"vor","delay-in-days":86,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pacing Clinical Electrophis"],"published-print":{"date-parts":[[2003,1]]},"abstract":"<jats:p> <jats:bold>MACLE, L., <jats:sc>et al.<\/jats:sc>: Radiation Exposure During Radiofrequency Catheter Ablation for Atrial Fibrillation.<\/jats:bold>\n          <jats:italic>RF catheter ablation of paroxysmal atrial fibrillation (PAF) is associated with prolonged fluoroscopy. The procedural duration and fluoroscopic exposure to patients and medical staff were recorded and compared among 43 ablation procedures for PAF, 20 for common atrial flutter, and 16 for accessory pathways. Patient radiation exposure was measured by dosimeters placed over the xyphoid, while that of physicians and nurses was measured by dosimeters placed outside and inside the lead apron. The mean fluoroscopy time was<\/jats:italic>\n          <jats:styled-content>\n              <jats:italic>57 \u00b1 30<\/jats:italic>\n            <\/jats:styled-content>\n          <jats:italic>minutes for PAF,<\/jats:italic>\n          <jats:styled-content>\n              <jats:italic>20 \u00b1 10<\/jats:italic>\n            <\/jats:styled-content>\n          <jats:italic>minutes for common flutter, and<\/jats:italic>\n          <jats:styled-content>\n              <jats:italic>22 \u00b1 21<\/jats:italic>\n            <\/jats:styled-content>\n          <jats:italic>minutes for accessory pathway ablation. The patient median radiation exposure was 1110\u03bcSv for PAF, compared with 500 \u03bcSv for common flutter and 560 \u03bcSv for accessory pathway ablation (P &lt; 0.01). The median radiation exposure to physician and nurse inside the lead apron were, respectively, 2 \u03bcSv and 3 \u03bcSv for PAF, 1 \u03bcSv and 2 \u03bcSv for common flutter, and &lt;0.5 \u03bcSv and 3 \u03bcSv for accessory pathway ablations. RF catheter ablation for PAF was associated with prolonged fluoroscopy times and a twofold higher radiation exposure to the patient and physician compared with other ablation procedures. Assuming 300 procedures\/year, radiation exposure to the medical staff was below the upper recommended annual dose limit. (PACE 2003; 26[Pt. II]:288\u2013291)<\/jats:italic> <\/jats:p>","DOI":"10.1046\/j.1460-9592.2003.00034.x","type":"journal-article","created":{"date-parts":[[2004,12,28]],"date-time":"2004-12-28T08:02:53Z","timestamp":1104220973000},"page":"288-291","source":"Crossref","is-referenced-by-count":69,"title":["Radiation Exposure During Radiofrequency Catheter Ablation for Atrial Fibrillation"],"prefix":"10.1111","volume":"26","author":[{"given":"LAURENT","family":"MACLE","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"RUKSHEN","family":"WEERASOORIYA","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"PIERRE","family":"JAIS","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"CHRISTOPHE","family":"SCAVEE","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"FLORENCE","family":"RAYBAUD","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"KEE\u2010JOON","family":"CHOI","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"MELEZE","family":"HOCINI","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"JACQUES","family":"CLEMENTY","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"MICHEL","family":"HAISSAGUERRE","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2003,3,28]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.101.12.1409"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8167.1997.tb00855.x"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(00)00908-5"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.84.6.2376"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(92)91278-C"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.101.7.772"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.102.21.2565"},{"key":"e_1_2_6_9_2","first-page":"1","volume-title":"Ann ICRP","author":"IRCP 60","year":"1990"},{"key":"e_1_2_6_10_2","unstructured":"National Council on Radiation Protection and Measurements:Recommendations on Limits for Exposure to Ionizing Radiation. Bethesda MD National Council on Radiation Protection and Measurements 1987."},{"key":"e_1_2_6_11_2","doi-asserted-by":"crossref","unstructured":"WittkampfFH WeverEF VosK et al.Reduction of radiation exposure in the cardiac electrophysiology laboratory. PACE2000;23:1638\u20131644.","DOI":"10.1046\/j.1460-9592.2000.01638.x"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(98)00356-7"}],"container-title":["Pacing and Clinical Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1046%2Fj.1460-9592.2003.00034.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1046\/j.1460-9592.2003.00034.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,13]],"date-time":"2023-10-13T12:02:57Z","timestamp":1697198577000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1046\/j.1460-9592.2003.00034.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2003,1]]},"references-count":11,"journal-issue":{"issue":"1p2","published-print":{"date-parts":[[2003,1]]}},"alternative-id":["10.1046\/j.1460-9592.2003.00034.x"],"URL":"https:\/\/doi.org\/10.1046\/j.1460-9592.2003.00034.x","archive":["Portico"],"relation":{},"ISSN":["0147-8389","1540-8159"],"issn-type":[{"value":"0147-8389","type":"print"},{"value":"1540-8159","type":"electronic"}],"subject":[],"published":{"date-parts":[[2003,1]]}}}