{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,22]],"date-time":"2025-10-22T17:31:48Z","timestamp":1761154308670},"reference-count":34,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2001,12,24]],"date-time":"2001-12-24T00:00:00Z","timestamp":1009152000000},"content-version":"vor","delay-in-days":663,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Euro J of Neurology"],"published-print":{"date-parts":[[2000,3]]},"abstract":"<jats:p>The aim of our study was to establish colour Doppler\u2010assisted duplex imaging (CDDI)\u2010criteria to predict an angiographic internal carotid artery (ICA) stenosis of at least 70%, according to the North American Symptomatic Carotid Endarterectomy Trial (NASCET) and European Carotid Surgery Trialists (ECST) methods of measurement. In the following, we describe the findings in 79 patients who were screened for carotid endarterectomy by CDDI and further evaluated by digital subtraction angiography (DSA). In 158 carotid arteries, 107 stenoses of &gt;\u200330% and nine occlusions were found. Receiver operator characteristic graphs were constructed in order to calculate sensitivities and specificities of the assessment by CDDI in the prediction of high\u2010grade stenoses determined by angiography. Optimal cut\u2010off points were defined by highest accuracy which reflects the combination of high sensitivity and specificity. The critical index of a high\u2010grade ICA stenosis according to the ECST method could be predicted with an accuracy greater than 90% by a systolic peak velocitiy of 1.25\u2003m\/s or an area reduction by CDDI of 70%. Corresponding values, 1.6 m\/s and 80% area reduction, predicted the stenosis indexes according to the NASCET method less reliably, with accuracies of between 80% and 90%. Flow velocity criterion was slightly less accurate than the area reduction criterion by CDDI. Finally, double\u2010blind evaluation performed by two readers per examination modality showed that the measurement of area reduction in CDDI is at least as reliable as stenosis indexes according to ECST and NASCET methods.<\/jats:p>","DOI":"10.1046\/j.1468-1331.2000.00031.x","type":"journal-article","created":{"date-parts":[[2003,3,11]],"date-time":"2003-03-11T19:36:29Z","timestamp":1047411389000},"page":"183-190","update-policy":"http:\/\/dx.doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Prediction of angiographic carotid artery stenosis indexes by colour Doppler\u2010assisted duplex imaging. A critical appraisal of the parameters used"],"prefix":"10.1111","volume":"7","author":[{"given":"L.","family":"B\u00f6nig","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B.","family":"Weder","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D.","family":"Sch\u00f6tt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Keel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"T.","family":"Nguyen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"W.","family":"Zaunbauer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2001,12,24]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.24.9.1292"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.28.6.1208"},{"key":"e_1_2_6_4_1","first-page":"1048","article-title":"Symptomatic Carotid Artery Stenosis: a solvable problem.","volume":"23","author":"Barnett HJM","year":"1992","journal-title":"North Am Symptomatic Carotid Endarterectomy Trial Stroke"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9610(96)00137-7"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.27.4.695"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.14.6.885"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1078-5884(98)80111-1"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1136\/jnnp.56.9.967"},{"key":"e_1_2_6_10_1","first-page":"1299","article-title":"Stenosis of the internal carotid artery: assessment using color Doppler imaging compared with angiography.","volume":"152","author":"Erickson SJ","year":"1989","journal-title":"Am J Radiology"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/0140-6736(91)92916-P"},{"key":"e_1_2_6_12_1","doi-asserted-by":"crossref","first-page":"1421","DOI":"10.1001\/jama.1995.03520420037035","article-title":"Endarterectomy for asymptomatic carotid stenosis.","volume":"273","author":"Executive Committee for the Asymptomatic carotid Atherosclerosis Study","year":"1995","journal-title":"JAMA"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0741-5214(94)70006-0"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.186.2.8421726"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1111\/jon19977140"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1097\/00019052-199902000-00010"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0741-5214(96)70269-0"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.1007\/s100169900146"},{"key":"e_1_2_6_19_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.30.2.282"},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/0741-5214(93)90019-I"},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0741-5214(96)70140-4"},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM199108153250701"},{"key":"e_1_2_6_23_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM199811123392002"},{"key":"e_1_2_6_24_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.30.2.402"},{"key":"e_1_2_6_25_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF00873545"},{"key":"e_1_2_6_26_1","first-page":"1058","article-title":"The effect of carotid siphon stenosis on stroke rate, death, and relief of symptoms following elective carotid endarterectomy.","volume":"92","author":"Schuler JJ","year":"1982","journal-title":"Surgery"},{"key":"e_1_2_6_27_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.28.6.1211"},{"key":"e_1_2_6_28_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.24.10.1513"},{"issue":"1","key":"e_1_2_6_29_1","first-page":"24","article-title":"Non\u2010invasive evaluation of internal carotid stenosis with colour Doppler\u2010assisted duplex imaging.","volume":"51","author":"Sitzer M","year":"1996","journal-title":"Clin Radiol"},{"key":"e_1_2_6_30_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.STR.10.3.326"},{"key":"e_1_2_6_31_1","doi-asserted-by":"publisher","DOI":"10.1111\/jon199444222"},{"key":"e_1_2_6_32_1","first-page":"643","article-title":"Magnetic resonance angiography and duplex imaging: Noninvasive tests for selecting symptomatic carotid endarterectomy candidates.","volume":"114","author":"Turnipseed WD","year":"1993","journal-title":"Surgery"},{"key":"e_1_2_6_33_1","first-page":"1635","article-title":"Carotid stenosis by digital subtraction angiography: reproducibility of the European Carotid Surgery Trial and the North American Symptomatic Carotid Endarterectomey Trial measurements methods and visual interpretation.","volume":"15","author":"Vanninen R","year":"1994","journal-title":"Am J Neuroradiol"},{"key":"e_1_2_6_34_1","doi-asserted-by":"publisher","DOI":"10.1136\/jnnp.60.2.152"},{"key":"e_1_2_6_35_1","doi-asserted-by":"publisher","DOI":"10.1111\/jon199883132"}],"container-title":["European Journal of Neurology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1046%2Fj.1468-1331.2000.00031.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full\/10.1046\/j.1468-1331.2000.00031.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,29]],"date-time":"2023-10-29T07:51:52Z","timestamp":1698565912000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1046\/j.1468-1331.2000.00031.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2000,3]]},"references-count":34,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2000,3]]}},"alternative-id":["10.1046\/j.1468-1331.2000.00031.x"],"URL":"https:\/\/doi.org\/10.1046\/j.1468-1331.2000.00031.x","archive":["Portico"],"relation":{},"ISSN":["1351-5101","1468-1331"],"issn-type":[{"value":"1351-5101","type":"print"},{"value":"1468-1331","type":"electronic"}],"subject":[],"published":{"date-parts":[[2000,3]]},"assertion":[{"value":"2001-12-24","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}