{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T21:35:02Z","timestamp":1774992902026,"version":"3.50.1"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[1999,11,1]],"date-time":"1999-11-01T00:00:00Z","timestamp":941414400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Ophthalmic Physiologic Optic"],"published-print":{"date-parts":[[1999,11]]},"abstract":"<jats:title>Summary<\/jats:title>\n                  <jats:p>Two mathematical models were developed to describe the topographical corneal swelling response to hydrogel contact lenses and the effect of these changes on refractive error. In one, corneal thickness changes resulted in deformation of the anterior corneal surface. In the other, the posterior surface only was deformed. Refractive error, corneal thickness and corneal shape were monitored in a sample of adapted contact lens wearers with one eye patched for 4 \u2003h while wearing a soft contact lens. The experimental data were most consistent with the model in which the posterior surface only was deformed.<\/jats:p>","DOI":"10.1046\/j.1475-1313.1999.00470.x","type":"journal-article","created":{"date-parts":[[2003,3,12]],"date-time":"2003-03-12T10:53:32Z","timestamp":1047466412000},"page":"475-480","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":25,"title":["The cornea swells in the posterior direction under hydrogel contact lenses"],"prefix":"10.1007","volume":"19","author":[{"given":"Paul","family":"Erickson","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Timothy L.","family":"Comstock","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael J.","family":"Doughty","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anthony P.","family":"Cullen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[1999,11]]},"reference":[{"key":"e_1_2_5_2_1","first-page":"669","article-title":"The interrelationship of corneal thickness and shape changes.","volume":"43","author":"Bailey I. L.","year":"1972","journal-title":"J. Am. Optom. Assoc."},{"key":"e_1_2_5_3_1","first-page":"363","article-title":"Adaptation to hydrogel contact lenses: variations in myopia and corneal curvature measurements.","volume":"48","author":"Barnett W. A.","year":"1977","journal-title":"J. Am. Optom. Assoc."},{"key":"e_1_2_5_4_1","first-page":"37","article-title":"Myopia control study: effect of different contact lens refractive corrections on the progression of myopia.","volume":"28","author":"Bier N.","year":"1988","journal-title":"Optom. Today"},{"key":"e_1_2_5_5_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-198502000-00002"},{"key":"e_1_2_5_6_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-198607000-00004"},{"key":"e_1_2_5_7_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-198410000-00002"},{"key":"e_1_2_5_8_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1475-1313.1989.tb00902.x"},{"issue":"4","key":"e_1_2_5_9_1","first-page":"28","article-title":"Utilizing corneal topography to diagnose soft lens induced corneal hypoxia.","volume":"38","author":"Buffington R.","year":"1995","journal-title":"Contacto"},{"key":"e_1_2_5_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/0892-8967(90)90031-A"},{"key":"e_1_2_5_11_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-197704000-00005"},{"key":"e_1_2_5_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/0892-8967(95)00061-X"},{"key":"e_1_2_5_13_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-199603000-00008"},{"key":"e_1_2_5_14_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-197305000-00003"},{"key":"e_1_2_5_15_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-197506000-00005"},{"key":"e_1_2_5_16_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-197505000-00002"},{"key":"e_1_2_5_17_1","first-page":"1214","article-title":"Changes in corneal curvature and refractive error upon refitting with flatter hydrophilic contact lenses.","volume":"47","author":"Hill J. F.","year":"1976","journal-title":"J. Am. Optom. Assoc."},{"issue":"4","key":"e_1_2_5_18_1","first-page":"23","article-title":"Variations in refractive error and corneal curvature after wearing ultra\u2010thin hydrophilic contact lenses.","volume":"3","author":"Hill J. F.","year":"1976","journal-title":"Int. Contact Lens Clin."},{"key":"e_1_2_5_19_1","first-page":"343","article-title":"Effects of cataract surgery on corneal function.","volume":"22","author":"Holden B. A.","year":"1982","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"e_1_2_5_20_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.1985.tb01581.x"},{"key":"e_1_2_5_21_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.1983.tb01403.x"},{"key":"e_1_2_5_22_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-197608000-00005"},{"issue":"5","key":"e_1_2_5_23_1","first-page":"8F","article-title":"In or out of RGPs or soft lenses: when your patients are ready for a change.","volume":"37","author":"Kendall J. H.","year":"1998","journal-title":"AOA News"},{"key":"e_1_2_5_24_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006324-198212000-00007"},{"key":"e_1_2_5_25_1","doi-asserted-by":"publisher","DOI":"10.1080\/713820960"},{"key":"e_1_2_5_26_1","volume-title":"Wolff\u2019s Anatomy of the Eye and Orbit","author":"Last R. J.","year":"1968"},{"issue":"1","key":"e_1_2_5_27_1","first-page":"88","article-title":"Corneal edema and curvature changes from gel lenses.","volume":"2","author":"Mandell R. B.","year":"1975","journal-title":"Int. Contact Lens Clin."},{"key":"e_1_2_5_28_1","first-page":"191","article-title":"Relationship between corneal edema and topography.","volume":"21","author":"Rom M. E.","year":"1995","journal-title":"CLAO J"}],"container-title":["Ophthalmic and Physiological Optics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1046%2Fj.1475-1313.1999.00470.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1046\/j.1475-1313.1999.00470.x","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1046\/j.1475-1313.1999.00470.x","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1046\/j.1475-1313.1999.00470.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T11:25:19Z","timestamp":1767785119000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1046\/j.1475-1313.1999.00470.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1999,11]]},"references-count":27,"journal-issue":{"issue":"6","published-print":{"date-parts":[[1999,11]]}},"alternative-id":["10.1046\/j.1475-1313.1999.00470.x"],"URL":"https:\/\/doi.org\/10.1046\/j.1475-1313.1999.00470.x","archive":["Portico"],"relation":{},"ISSN":["0275-5408","1475-1313"],"issn-type":[{"value":"0275-5408","type":"print"},{"value":"1475-1313","type":"electronic"}],"subject":[],"published":{"date-parts":[[1999,11]]},"assertion":[{"value":"1999-11-01","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}