{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,15]],"date-time":"2026-03-15T01:08:01Z","timestamp":1773536881355,"version":"3.50.1"},"reference-count":58,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2001,10,1]],"date-time":"2001-10-01T00:00:00Z","timestamp":1001894400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2001,10,1]],"date-time":"2001-10-01T00:00:00Z","timestamp":1001894400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["neuromodulationjournal.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Neuromodulation: Technology at the Neural Interface"],"published-print":{"date-parts":[[2001,10]]},"DOI":"10.1046\/j.1525-1403.2001.00176.x","type":"journal-article","created":{"date-parts":[[2003,3,12]],"date-time":"2003-03-12T10:04:54Z","timestamp":1047463494000},"page":"176-186","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":4,"title":["Current Status and Future Prospects for Upper and Lower Extremity Motor System Neuroprostheses"],"prefix":"10.1016","volume":"4","author":[{"given":"Marko","family":"Munih","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masayoshi","family":"Ichie","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1046\/j.1525-1403.2001.00176.x_bib1","first-page":"101","article-title":"Functional electrotherapy: stimulation of the peroneal nerve synchronized with the swing phase of the gait of hemiplegic patients","volume":"42","author":"Liberson","year":"1961","journal-title":"Arch Phys Med Rehabil"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib2","series-title":"Functional Electrical Stimulation; Applications in Neural Prostheses","first-page":"iii","article-title":"Preface","author":"Hambrecht","year":"1977"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib3","series-title":"Functional Electrical Stimulation; Applications in Neural Prostheses","first-page":"39","article-title":"Functional electrical stimulation in Ljubljana. Project, Problem, Perspectives","author":"Vodovnik","year":"1977"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib4","series-title":"Functional Electrical Stimulation; Applications in Neural Prostheses","first-page":"83","article-title":"Restoration of hand function in the quadriplegic through electrical stimulation","author":"Peckham","year":"1977"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib5","doi-asserted-by":"crossref","first-page":"530","DOI":"10.1109\/TBME.1981.324740","article-title":"Multichannel implantable stimulator for control of paralyzed muscle","volume":"28","author":"Peckham","year":"1981","journal-title":"IEEE Trans Biomed Eng"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib6","doi-asserted-by":"crossref","first-page":"533","DOI":"10.2106\/00004623-199704000-00008","article-title":"An implanted upper-extremity neuroprosthesis","volume":"79A","author":"Kilgore","year":"1997","journal-title":"J Bone Joint Surg"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib7","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1007\/978-94-009-3361-3_6","article-title":"Functional electrical stimulation for the control of the upper extremities","volume":"12","author":"Handa","year":"1987","journal-title":"Med Prog Thr Tech"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib8","first-page":"241","article-title":"Functional electrical stimulation (FES) systems for restoration of motor function of paralyzed muscles; versatile systems and a portable system","volume":"4","author":"Handa","year":"1992","journal-title":"Frontiers Med Biol Eng"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib9","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1007\/BF02441635","article-title":"An FNS-based system for generating upper limb function in the C4 quadriplegic","volume":"27","author":"Nathan","year":"1989","journal-title":"Med Biol Eng Comput"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib10","first-page":"86","article-title":"The NESS Handmaster orthosis: restoration of hand function in C5 and stroke patients by means of electrical stimulation","volume":"9","author":"Ijzerman","year":"1996","journal-title":"J Rehab Sci"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib11","doi-asserted-by":"crossref","first-page":"608","DOI":"10.1016\/S0003-9993(97)90426-3","article-title":"The Bionic Glove. An electrical stimulator garment that provides controlled grasp and hand opening in quadriplegia","volume":"78","author":"Prochazka","year":"1997","journal-title":"Arch Phys Med Rehabil"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib12","unstructured":"Loeb GE, Richmond FJR. FES or TES. How to start an industry? Proceedings of the 5th Annual IFESS Conference 1999: 169\u2013172."},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib13","doi-asserted-by":"crossref","first-page":"1116","DOI":"10.1093\/ptj\/63.7.1116","article-title":"The use of a four channel electrical stimulator as an ambulatory aid for paraplegic patients","volume":"63","author":"Bajd","year":"1983","journal-title":"Phys Ther"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib14","series-title":"Functional Electrical Stimulation. Standing and Walking After Spinal Cord Injury","author":"Kralj","year":"1989"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib15","series-title":"Functional Electrical Stimulation for Ambulation by Paraplegics","author":"Graupe","year":"1994"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib16","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1046\/j.1525-1594.1999.06360.x","article-title":"Use of functional electrical stimulation in the lower extremities of incomplete SCI patients","volume":"23","author":"Bajd","year":"1999","journal-title":"Artif Org"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib17","first-page":"515","article-title":"Electrical stimulation in treating spasticity resulting from SCI","volume":"66","author":"Bajd","year":"1985","journal-title":"Arch Phys Med Rehabil"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib18","unstructured":"Mayr W, Freilinger G, Rafolt D, et-al. Functional electrical stimulation (FES) as a countermeasure against muscular atrophy in long-term space flights-first application on board of MIR station. Proceedings of the 5th Annual IFESS Conference 2000: 27\u201330."},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib19","unstructured":"Wood DE, Harper VJ, Barr FMD, Taylor PN, Phillips GF, Ewins DJ. Experience in using knee angles as part of a closed-loop algorithm to control FES-assisted paraplegic standing. Proceedings of the 6th Vienna International Workshop 1998: 137-140."},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib20","first-page":"174","article-title":"Current status of walking orthoses for thoracic paraplegics","volume":"15","author":"D\u2019Ambrosia","year":"1995","journal-title":"Iowa Orthop J"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib21","first-page":"32","article-title":"Augmentation of the Oswestry Parawalker orthosis by means of surface electrical stimulation: gait analysis of three patients","volume":"25","author":"McClelland","year":"1987","journal-title":"Paraplegia"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib22","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1109\/86.313148","article-title":"Synthesis of paraplegic gait with multichannel functional neuromuscular stimulation","volume":"2","author":"Kobetic","year":"1994","journal-title":"IEEE Trans Rehab Eng"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib23","unstructured":"Hoshimiya N, Iguchi Y, Handa Y. Next generation FES system in the 21st century. Proceedings of the 5th Annual IFESS Conference 1999: 15-16."},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib24","unstructured":"Fuji T, Tanaka S, Ichie M, et-al. Development of a new implantable system for functional electrical stimulation in Sendai FES project. Proceedings of the 5th Annual IFESS Conference 1999: 283\u2013286"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib25","doi-asserted-by":"crossref","first-page":"711","DOI":"10.1016\/S0140-6736(97)24036-5","article-title":"Neuroprosthesis for leg function after spinal-cord injury","volume":"360","author":"Donaldson","year":"1997","journal-title":"Lancet"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib26","unstructured":"Davis R, Houdayer T, Andrews B, Barriskill A, Parker S. Paraplegia: Implantable praxis 24-FES system and external sensors for multi-functional restoration. Proceedings of the 5th Annual IFESS Conference 2000: 35\u201338"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib27","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1111\/j.1525-1594.1997.tb04662.x","article-title":"Experience of clinical use of the odstock dropped foot stimulator","volume":"21","author":"Burridge","year":"1997","journal-title":"Artif Org"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib28","unstructured":"Vodovnik L, Dimitrijevic MR, Prevec T, Logar M. Electronic walking aids for patients with peroneal palsy. Proceedings of the European Symposium on Medical Electronics 1965: 58\u201361"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib29","series-title":"Human Locomotor Engineering: A Review of Developments in the Field Including Advances in Prosthetics and the Design of Aids and Controls","first-page":"45","article-title":"Improvement in locomotion in hemiplegic patients with multichannel electrical stimulation","author":"Kralj","year":"1971"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib30","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/S0003-9993(96)90214-2","article-title":"Peroneal stimulator: Evaluation for the correction of spastic drop foot in hemiplegia","volume":"77","author":"Granat","year":"1996","journal-title":"Arch Phys Med Rehabil"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib31","doi-asserted-by":"crossref","first-page":"1187","DOI":"10.3928\/0147-7447-19840701-12","article-title":"Multichannel electrical stimulation of gait in motor disabled patients","volume":"7","author":"Malezic","year":"1984","journal-title":"Orthopedics"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib32","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1109\/TBME.1979.326520","article-title":"Programmed six-channel electrical stimulator for complex stimulation of leg muscles during walking","volume":"26","author":"Strojnik","year":"1979","journal-title":"IEEE Trans Biomed Eng"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib33","unstructured":"Takebe K, Kukulka C, Narayan MG, Milner M, Basmajian JV. Peroneal nerve stimulator in rehabilitation of hemiplegic patients. Arch Phys Medical Rehabil 1975: 237\u2013240"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib34","unstructured":"Jeglic A, Vanken E, Benedik M. Implantable muscle\/nerve stimulator as part of an electronic brace. Proceedings of the 3rd International Symposium on ECHE. 1970: 593-603."},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib35","doi-asserted-by":"crossref","first-page":"37","DOI":"10.2340\/1650197787193743","article-title":"Treatment of drop foot using an implantable peroneal underknee stimulator","volume":"19","author":"Strojnik","year":"1987","journal-title":"Scand J Rehab Med"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib36","series-title":"Electrophysiological Kinesiology","first-page":"127","article-title":"Dual channel implantable stimulator","author":"Kelih","year":"1988"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib37","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1682\/JRRD.1992.10.0041","article-title":"Application of a programmable dual-channel adaptive electrical stimulation system for the control and analysis of gait","volume":"29","author":"Malezic","year":"1992","journal-title":"J Rehab Res Dev"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib38","unstructured":"Holsheimer J, Bultstra G, Verloop AJ, Van den Aa HE, Hermenes Hj. Implantable dual channel peroneal nerve stimulator. Proceedings of the Ljubljana FES Conference 1993: 42\u201344"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib39","unstructured":"Haugland MK, Childs CR, Ladouceur M, Haase J, Sinkjaer T. An implantable foot drop stimulator. Proceedings of the 5th Annual IFEES Conference 2000: 59\u201362"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib40","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1093\/ptj\/69.5.319","article-title":"Restoration of gait during two to three weeks of therapy with multichannel electrical stimulation","volume":"69","author":"Bogataj","year":"1989","journal-title":"Phys Ther"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib41","unstructured":"Ewins D. The compustim 10b electrical stimulator. Proceedings of the 5th IPEM Clinical Functional Electrical Stimulation Meeting 1997: 6"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib42","doi-asserted-by":"crossref","first-page":"1047","DOI":"10.2106\/00004623-197557080-00002","article-title":"Experimental correction of footdrop by electrical stimulation of the peroneal nerve","volume":"57A","author":"Waters","year":"1975","journal-title":"J Bone Joint Surg"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib43","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1109\/TBME.1986.325808","article-title":"Sensors for use with functional neuromuscular stimulation","volume":"33","author":"Crago","year":"1986","journal-title":"IEEE Trans Biomed Eng"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib44","unstructured":"Symons J, McNeal D, Waters RL, Perry J. Trigger switches for implantable gait stimulation. Proceedings of the 9th Annual RESNA Conference 1986: 319"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib45","doi-asserted-by":"crossref","first-page":"1201","DOI":"10.1109\/10.64463","article-title":"Automatic stance-swing phase detection from accelerometer data for peroneal nerve stimulation","volume":"37","author":"Willemsen","year":"1990","journal-title":"IEEE Trans Biomed Eng"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib46","doi-asserted-by":"crossref","first-page":"1186","DOI":"10.1109\/10.137284","article-title":"Lower extremity angle measurement with accelerometers \u2013 error and sensitivity analysis","volume":"38","author":"Willemsen","year":"1991","journal-title":"IEEE Trans Biomed Eng"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib47","unstructured":"Luinge HJ, Veltink PH, Baten CTM. Estimating orientation with gyroscopes and accelerometers. Proceedings of the of the International Biomecharonics Workshop 1999: 214\u2013218"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib48","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1109\/86.506403","article-title":"Application of tilt sensors in functional electrical stimulation","volume":"4","author":"Dai","year":"1996","journal-title":"IEEE Trans Rehab Eng"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib49","doi-asserted-by":"crossref","unstructured":"Hoffer JA, Haugland MK, Li T. Obtaining skin contact force information from implanted nerve cuff recording electrodes. Proceedings of the IEEE EMBS. 1989: 928-929.","DOI":"10.1109\/IEMBS.1989.96052"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib50","unstructured":"Mourselas N, Granat MH. Correction of drop foot using a fuzzy logic controlled miniature stimulator. Proceedings of the 5th Annual IFESS Conference 2000: 456\u2013457"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib51","unstructured":"Lim SK, Jeong HC, Lee SS, Jin DB, Lee MY, Park BR. Closed-loop FES for restoration of gait function in patients with foot drop. Proceedings of the 5th Annual IFESS Conference 1999: 239\u2013241"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib52","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1109\/TBME.1981.324719","article-title":"A technique for collision block of peripheral nerve: frequency dependence","volume":"28","author":"Van den Honert","year":"1981","journal-title":"IEEE Trans Biomed Eng"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib53","unstructured":"Marshall R, Rischbieth H, Clark JM, Jelbart JM, Donohoe S, Strayer J, Sharpe M. Critical issues in the transition of FES technology from research laboratory to clinical practice: a study of subject presentation and recruitment. Proceedings of the 5th Annual IFESS Conference 2000: 17\u201320."},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib54","unstructured":"Mushahwar VK, Prochazka A. Spinal cord microstimulation: Long-term stability of implanted wires and evoked responses. Proceedings of the 5th Annual IFESS Conference 2000: 127\u2013128."},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib55","unstructured":"Lyons GM, Sweeney PC, Bradley ME, Hourigan TF, O\u2019Keefe DT. The university of limerick drop foot stimulator. Proceedings of the 5th IPEM Clinical FES Meeting 1997: 68\u201369"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib56","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1097\/00003086-200104000-00035","article-title":"Surgical technique for installing an eight-channel neuroprosthesis for standing","volume":"385","author":"Davis","year":"2001","journal-title":"Clin Ortho Rel Res"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib57","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1080\/10790268.2000.11753516","article-title":"The Case Western Reserve University hybrid gait orthosis","volume":"23","author":"Marsolais","year":"1999","journal-title":"J Spinal Cord Med"},{"key":"10.1046\/j.1525-1403.2001.00176.x_bib58","doi-asserted-by":"crossref","unstructured":"Kobetic R, Triolo RJ, Uhlir JP et al. Implanted functional electrical stimulation system for mobility in paraplegia: A follow-up case report. IEEE Trans Rehab Eng 1999; 7:","DOI":"10.1109\/86.808942"}],"container-title":["Neuromodulation: Technology at the Neural Interface"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1046%2Fj.1525-1403.2001.00176.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1094715921004803?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1094715921004803?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/onlinelibrary.wiley.com\/wol1\/doi\/10.1046\/j.1525-1403.2001.00176.x\/fullpdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T21:45:59Z","timestamp":1761083159000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1094715921004803"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2001,10]]},"references-count":58,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2001,10]]}},"alternative-id":["S1094715921004803"],"URL":"https:\/\/doi.org\/10.1046\/j.1525-1403.2001.00176.x","relation":{},"ISSN":["1094-7159"],"issn-type":[{"value":"1094-7159","type":"print"}],"subject":[],"published":{"date-parts":[[2001,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Current Status and Future Prospects for Upper and Lower Extremity Motor System Neuroprostheses","name":"articletitle","label":"Article Title"},{"value":"Neuromodulation: Technology at the Neural Interface","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1046\/j.1525-1403.2001.00176.x","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2001 International Neuromodulation Society. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}