{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T22:36:35Z","timestamp":1790202995199,"version":"4.1.0"},"reference-count":33,"publisher":"Wiley","issue":"10","license":[{"start":{"date-parts":[[2002,9,25]],"date-time":"2002-09-25T00:00:00Z","timestamp":1032912000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Artificial Organs"],"published-print":{"date-parts":[[2002,10]]},"abstract":"<jats:p><jats:bold>Abstract:<\/jats:bold> We analyzed midterm results using the Bicarbon valve in a single center. Forty\u2010four patients had aortic valve replacement (AVR), 48 had mitral valve replacement (MVR), and 13 had both aortic and mitral valve replacement (DVR). The mean age of the 105 patients was 61.2 \u00b1 11.3 years. The mean follow\u2010up was 1.8 \u00b1 1.1 years with a cumulative follow\u2010up of 188 patient\u2010years. There were 5 early deaths (4.7%: 4 in the AVR group and 1 in the MVR group) and 5 late deaths (2.7% per patient\u2010year: 3 malignancy, 1 cerebral hemorrhage, 1 myocardial infarction). Survival at 3 years was 91 \u00b1 4% in the AVR group, 92 \u00b1 5% in the MVR group, and 66 \u00b1 23% in the DVR group. The linearized incidence of thromboembolic complications, hemorrhagic complications, and paravalvular leaks in all patients was 1.06 \u00b1 2.34%, 1.60 \u00b1 2.53%, and 0.53 \u00b1 2.22% per patient\u2010year, respectively. No other complications were observed. In conclusion, the Bicarbon prosthetic heart valve has shown excellent clinical results associated with a low incidence of valve\u2010related complications.<\/jats:p>","DOI":"10.1046\/j.1525-1594.2002.06987.x","type":"journal-article","created":{"date-parts":[[2003,3,11]],"date-time":"2003-03-11T03:13:12Z","timestamp":1047352392000},"page":"856-861","source":"Crossref","is-referenced-by-count":5,"title":["Single\u2010Center Experience with the Bicarbon Bileaflet Prosthetic Heart Valve in Japan"],"prefix":"10.1111","volume":"26","author":[{"given":"Yoshio","family":"Misawa","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tsutomu","family":"Saito","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroaki","family":"Konishi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shin\u2010ichi","family":"Oki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuichiro","family":"Kaminishi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yasuhiro","family":"Tezuka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kei","family":"Aizawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hideki","family":"Takahashi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nobuyuki","family":"Hasegawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Osamu","family":"Kamisawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Morito","family":"Kato","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katsuo","family":"Fuse","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2002,9,25]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1016\/S0022-5223(19)33862-0","article-title":"Clinical experience with the Omnicarbon prosthetic heart valve.","volume":"105","author":"Misawa Y","year":"1993","journal-title":"J Thorac Cardiovasc Surg"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(99)00557-3"},{"key":"e_1_2_6_4_2","first-page":"113","article-title":"Midterm clinical results with the CarboMedics Prosthetic heart valve.","volume":"25","author":"Misawa Y","year":"1997","journal-title":"Jpn J Cardiovasc Surg"},{"key":"e_1_2_6_5_2","first-page":"247","article-title":"Clinical evaluation of ATS prosthetic valve by doppler echocardiography: comparison with St. Jude Medical (SJM) valve.","volume":"6","author":"Hasegawa M","year":"2000","journal-title":"Ann Thorac Cardiovasc Surg"},{"key":"e_1_2_6_6_2","first-page":"389","article-title":"Mid\u2010term results with 1,503 CarboMedics mechanical valve implants.","volume":"9","author":"Dalrymple\u2010Hay MJ","year":"2000","journal-title":"J Heart Valve Dis"},{"key":"e_1_2_6_7_2","first-page":"403","article-title":"Comparative clinical outcomes with St. Jude Medical, Medtronic Hall and CarboMedics mechanical heart valves.","volume":"10","author":"Masters RG","year":"2001","journal-title":"J Heart Valve Dis"},{"key":"e_1_2_6_8_2","first-page":"185","article-title":"Long\u2010term results with St. Jude Medical and CarboMedics prosthetic heart valves.","volume":"10","author":"Chang BC","year":"2001","journal-title":"J Heart Valve Dis"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(00)02652-7"},{"key":"e_1_2_6_10_2","first-page":"177","article-title":"Twelve years' clinical experience with the CarboMedics prosthetic heart valve.","volume":"10","author":"Aagaard J","year":"2001","journal-title":"J Heart Valve Dis"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1097\/00002480-200111000-00021"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/00002480-199207000-00107"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF01235528"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(96)00531-0"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(99)01292-8"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.99.20.2669"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-5223(98)70212-0"},{"key":"e_1_2_6_18_2","first-page":"507","article-title":"Long\u2010term clinical performance of Sorin tilting\u2010disc mechanical prostheses in the mitral and aortic position.","volume":"38","author":"Hurle A","year":"1997","journal-title":"J Cardiovasc Surg"},{"key":"e_1_2_6_19_2","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1016\/S0022-5223(94)70084-2","article-title":"Early and late\u2010phase events after valve replacement with the St. Jude Medical prosthesis in 1200 patients.","volume":"107","author":"Fernandez J","year":"1994","journal-title":"J Thorac Cardiovasc Surg"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/0003-4975(90)90676-W"},{"key":"e_1_2_6_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(98)00443-3"},{"key":"e_1_2_6_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/0003-4975(94)90719-6"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(98)00467-6"},{"key":"e_1_2_6_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0003-4975(00)01191-7"},{"key":"e_1_2_6_25_2","first-page":"455","article-title":"Mitral valve replacement with St. Jude Medical prosthesis and low\u2010dose anticoagulation in patients aged over 50 years.","volume":"7","author":"Katircioglu SF","year":"1998","journal-title":"J Heart Valve Dis"},{"key":"e_1_2_6_26_2","doi-asserted-by":"crossref","first-page":"1008","DOI":"10.1016\/S0022-5223(19)34286-2","article-title":"Ten\u2010year follow\u2010up study of patients who had double valve replacement with the St. Jude Medical prosthesis.","volume":"98","author":"Arom KV","year":"1989","journal-title":"J Thorac Cardiovasc Surg"},{"key":"e_1_2_6_27_2","first-page":"303","article-title":"CarboMedics and Monostrut valves: clinical and hemodynamic outcomes in a randomized study.","volume":"9","author":"De La Fuente A","year":"2000","journal-title":"J Heart Valve Dis"},{"key":"e_1_2_6_28_2","first-page":"13","article-title":"Early single center experience with 192 Sorin Bicarbon valves.","volume":"37","author":"Di Salvo C","year":"1996","journal-title":"J Cardiovasc Surg"},{"key":"e_1_2_6_29_2","first-page":"596","article-title":"Early clinical results of Bicarbon valve prosthesis.","volume":"25","author":"Kuwaki K","year":"1996","journal-title":"Jpn J Artif Organs"},{"key":"e_1_2_6_30_2","first-page":"410","article-title":"The Bicarbon heart valve prosthesis: short\u2010term results.","volume":"6","author":"Casselman F","year":"1997","journal-title":"J Heart Valve Dis"},{"key":"e_1_2_6_31_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0894-7317(97)70026-9"},{"key":"e_1_2_6_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(99)00017-X"},{"key":"e_1_2_6_33_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1010-7940(98)00074-8"},{"key":"e_1_2_6_34_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0967-2109(00)00136-8"}],"container-title":["Artificial Organs"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1046%2Fj.1525-1594.2002.06987.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1046\/j.1525-1594.2002.06987.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,17]],"date-time":"2023-10-17T18:21:14Z","timestamp":1697566874000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1046\/j.1525-1594.2002.06987.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2002,9,25]]},"references-count":33,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2002,10]]}},"alternative-id":["10.1046\/j.1525-1594.2002.06987.x"],"URL":"https:\/\/doi.org\/10.1046\/j.1525-1594.2002.06987.x","archive":["Portico"],"relation":{},"ISSN":["0160-564X","1525-1594"],"issn-type":[{"value":"0160-564X","type":"print"},{"value":"1525-1594","type":"electronic"}],"subject":[],"published":{"date-parts":[[2002,9,25]]}}}