{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T06:26:36Z","timestamp":1791267996306,"version":"4.1.0"},"reference-count":42,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2003,5,15]],"date-time":"2003-05-15T00:00:00Z","timestamp":1052956800000},"content-version":"vor","delay-in-days":44,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Ther Apher Dial"],"published-print":{"date-parts":[[2003,4]]},"abstract":"<jats:p><jats:bold>Abstract:\u2002<\/jats:bold> Infection, thrombosis, and stenosis are among the most frequent complications associated with blood\u2010contacting catheters. These problems are usually related to surface properties of the base catheter material. Surface treatment processes, such as ion implantation and ion beam assisted deposition (IBAD) and microdomain structured surfaces, can be used to mitigate such complications. This study evaluated silver coated and implanted large bore catheters used for extracorporeal detoxification. In a 186 patient prospective study, 225 large bore catheters were inserted into the internal jugular or subclavian veins. Eighty\u2010five surface\u2010treated catheters (Spi\u2010Argent, Spire Corporation, Bedford, MA, USA ) and 28 catheters with surface treatment (Spi\u2010Silicone, Spire Corporation) were inserted in 90 patients. One hundred and twelve untreated catheters placed in 96 patients served as controls. After removal, the catheters were cultured for bacterial colonization using standard microbiologic assays. They also were examined using a scanning electron microscope (SEM). Bacterial colonization was observed in 8% of the treated catheter compared with 46.4% of untreated catheters. The SEM investigations showed all treated catheters to possess low thrombogenicity. Catheters with microdomain structured surfaces showed same results in preliminary observation. The surface treatments of the large bore catheters can be used to improve thrombus and infection resistance of blood contacting catheters.<\/jats:p>","DOI":"10.1046\/j.1526-0968.2003.00042.x","type":"journal-article","created":{"date-parts":[[2003,5,15]],"date-time":"2003-05-15T16:34:16Z","timestamp":1053016456000},"page":"225-231","source":"Crossref","is-referenced-by-count":13,"title":["Long\u2010term Catheters for Apheresis and Dialysis with Surface Treatment with Infection Resistance and Low Thrombogenicity"],"prefix":"10.1111","volume":"7","author":[{"given":"Rolf","family":"Bambauer","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pedro","family":"Mestres","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ralf","family":"Schiel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Silke","family":"Bambauer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Piran","family":"Sioshansi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Reinhard","family":"Latza","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2003,5,15]]},"reference":[{"key":"e_1_2_6_2_2","first-page":"867","article-title":"Haemodialysis by percutaneous catheterization of the femoral artery and vein with regional heparinization","author":"Shaldon S","year":"1981","journal-title":"Lancet"},{"key":"e_1_2_6_3_2","first-page":"23","volume-title":"Haemofiltration","author":"Kramer P","year":"1977"},{"key":"e_1_2_6_4_2","first-page":"65","article-title":"M\u00f6glichkeiten des tempor\u00e4ren Gef\u00e4\u00dfzugangs","volume":"12","author":"Schwarzbeck A","year":"1983","journal-title":"Mitt Klin Nephrologie"},{"key":"e_1_2_6_5_2","first-page":"766","article-title":"Transcutaneous insertion of the Shaldon catheter through the internal jugular vein as access for acute hemodialysis","volume":"11","author":"Bambauer R","year":"1982","journal-title":"Dial Transplant"},{"key":"e_1_2_6_6_2","first-page":"849","volume-title":"Hospital infections","author":"Maki DG","year":"1992"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/00005792-198407000-00001"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-119-12-199312150-00003"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1097\/00002480-199238020-00006"},{"key":"e_1_2_6_10_2","first-page":"5","article-title":"Side effects and infections associated with large\u2010bore catheters for extracorporeal detoxification methods","volume":"6","author":"Bambauer R","year":"1994","journal-title":"ECC Int"},{"key":"e_1_2_6_11_2","first-page":"285","article-title":"Microbiological colonization of prosthetic devises. Microtopological characteristics of intravenous catheters as detected by Scanning Electron Microscopy","volume":"173","author":"Locci R","year":"1981","journal-title":"Zentralbl Bakterial Mikrobiol Hyg"},{"key":"e_1_2_6_12_2","volume-title":"Vascular Access for Blood Purification, Methods and Catheter Technology.","author":"Bambauer R","year":"1992"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1002\/jca.2920070315"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1097\/00002480-199711000-00010"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1097\/00002480-199907000-00019"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1177\/039139889201500603"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1177\/039139889001300105"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/0955-3886(91)90112-G"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.1681\/ASN.V74523"},{"key":"e_1_2_6_20_2","first-page":"317","article-title":"Lagekontrolle gro\u00dflumiger zentraler Venenkatheter mittels intrakardialer","volume":"17","author":"Bambauer R","year":"1980","journal-title":"Elektrokardiographie Intensivmed"},{"key":"e_1_2_6_21_2","first-page":"117","article-title":"Experimentelle Untersuchungen zur Cavakatheterisierung mit integrierten EKG\u2010Lage\u2010Kontrollsystemen","volume":"16","author":"Rust M","year":"1991","journal-title":"Intensiv- U Notfallbehandl"},{"key":"e_1_2_6_22_2","first-page":"26","article-title":"A new silastic subclavian cannula for hemodialysis or plasma exchange","volume":"12","author":"Taylor RD","year":"1983","journal-title":"Dial Transplant"},{"key":"e_1_2_6_23_2","first-page":"626","article-title":"Alternative permanent access for home hemodialysis Dial","volume":"13","author":"Venatraman G","year":"1984","journal-title":"Transplant"},{"key":"e_1_2_6_24_2","first-page":"50","article-title":"Surface treatment of biomaterials by Ion\u2010Beam Processes","volume":"2","author":"Sioshansi P","year":"1995","journal-title":"Med Plastics Biomaterials"},{"key":"e_1_2_6_25_2","first-page":"5185","article-title":"Differenzierung verschiedener Kathetermaterialien nach Form","volume":"27","author":"Dathe G","year":"1977","journal-title":"Oberfl\u00e4che Funktion Therapiew"},{"key":"e_1_2_6_26_2","first-page":"228","article-title":"New surface\u2010treatment technologies for catheters used for extracorporeal detoxification methods","volume":"24","author":"Bambauer R","year":"1995","journal-title":"Dial Transplant"},{"key":"e_1_2_6_27_2","first-page":"326","article-title":"Scanning electron microscopic investigation of catheters for blood access","volume":"16","author":"Bambauer R","year":"1995","journal-title":"Int J Artif Organs"},{"key":"e_1_2_6_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/0168-583X(88)90193-0"},{"key":"e_1_2_6_29_2","first-page":"1092","article-title":"In vivo evaluation of antithrombogenicity for ion implanted silicone rubber using indium\u2010tropolone\u2010platelets","volume":"19","author":"Suzuki Y","year":"1990","journal-title":"Jpn J Artif Organs"},{"key":"e_1_2_6_30_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1525-1594.1994.tb02193.x"},{"key":"e_1_2_6_31_2","first-page":"24","article-title":"Ion implantation of cobalt\u2010chronicum prosthetic components to reduce polyethylene wear","volume":"11","author":"Sioshansi P","year":"1991","journal-title":"Orthopedics Today"},{"key":"e_1_2_6_32_2","doi-asserted-by":"publisher","DOI":"10.1055\/s-2007-995058"},{"key":"e_1_2_6_33_2","first-page":"396","article-title":"Use of subclavian and internal jugular vein catheterization in hemodialysis and plasmapheresis","volume":"1094","author":"Bratel J","year":"1987","journal-title":"Licej Vjesn"},{"key":"e_1_2_6_34_2","doi-asserted-by":"publisher","DOI":"10.1159\/000184523"},{"key":"e_1_2_6_35_2","first-page":"161","volume-title":"Infections Associated with Indwelling Medical Devices.","author":"Maki DG","year":"1989"},{"key":"e_1_2_6_36_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0039-6109(16)44432-4"},{"key":"e_1_2_6_37_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9343(88)90579-7"},{"key":"e_1_2_6_38_2","first-page":"784","article-title":"Antiseptic\u2010impregnated non\u2010tunneled central venous catheters: reducing infection risks and associated costs","volume":"25","author":"Civetta J","year":"1996","journal-title":"Dial Transplant"},{"key":"e_1_2_6_39_2","doi-asserted-by":"publisher","DOI":"10.1097\/00002480-199709000-00026"},{"key":"e_1_2_6_40_2","first-page":"626","article-title":"Biofilm formation on peritoneal catheter does not require the presence of infections","volume":"37","author":"Schwarz R","year":"1991","journal-title":"ASAIO Trans"},{"key":"e_1_2_6_41_2","doi-asserted-by":"publisher","DOI":"10.1016\/0142-9612(94)90028-0"},{"key":"e_1_2_6_42_2","doi-asserted-by":"publisher","DOI":"10.1097\/00002480-199807000-00013"},{"key":"e_1_2_6_43_2","doi-asserted-by":"publisher","DOI":"10.1177\/112972980100200303"}],"container-title":["Therapeutic Apheresis and Dialysis"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1046%2Fj.1526-0968.2003.00042.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1046\/j.1526-0968.2003.00042.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,13]],"date-time":"2023-10-13T18:38:30Z","timestamp":1697222310000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1046\/j.1526-0968.2003.00042.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2003,4]]},"references-count":42,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2003,4]]}},"alternative-id":["10.1046\/j.1526-0968.2003.00042.x"],"URL":"https:\/\/doi.org\/10.1046\/j.1526-0968.2003.00042.x","archive":["Portico"],"relation":{},"ISSN":["1744-9979","1744-9987"],"issn-type":[{"value":"1744-9979","type":"print"},{"value":"1744-9987","type":"electronic"}],"subject":[],"published":{"date-parts":[[2003,4]]}}}