{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T01:06:27Z","timestamp":1792717587851,"version":"4.5.0"},"reference-count":19,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2003,3,24]],"date-time":"2003-03-24T00:00:00Z","timestamp":1048464000000},"content-version":"vor","delay-in-days":7437,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Transfusion"],"published-print":{"date-parts":[[1982,11,12]]},"abstract":"<jats:p>Current serologic tests occasionally fail to identify women needing more than one vial of Rh immune globulin. We compared the indirect antiglobulin test after incubation with anti\u2010D and a rosetting technique using enzyme treated Rh2Rh2 erythrocytes as methods for identifying significant fetal maternal hemorrhage (FMH). Artificial mixtures containing 0.05 to 1.2 percent Rh1rh (CcDe) fetal red blood cells mixed with rh (ce) adult red blood cells were tested. The indirect antiglobulin test of the 0.6 percent mixture (approximately 30 ml FMH) was reported to be microscopically positive by 17\/20 technologists; whereas, 20\/20 found the rosetting test to be strongly positive. The volume of FMH in 118 postpartum Rh immune globulin candidates was quantified using Kleihauer's test and formula. The results of the rosetting and Kleihauer tests of blood specimens from these patients were negative 1.4 ml for two, and strongly positive rosetting test and FMH of 6.5 ml for one. The rosetting test utilizes routine blood banking skills and requires 5 minutes more \u201chands on\u201d time than an indirect antiglobulin test. Confirmation and quantification of positive results by an acid\u2010elution test is necessary.<\/jats:p>","DOI":"10.1046\/j.1537-2995.1982.22683068604.x","type":"journal-article","created":{"date-parts":[[2004,12,29]],"date-time":"2004-12-29T20:03:14Z","timestamp":1104350594000},"page":"468-471","source":"Crossref","is-referenced-by-count":39,"title":["Detection of fetal hemorrhage in Rh immune globulin candidates. A rosetting technique using enzyme\u2010treated Rh2Rh2 indicator erythrocytes"],"prefix":"10.1111","volume":"22","author":[{"given":"E.S.","family":"Sebring","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H.F.","family":"Polesky","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2003,3,24]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(68)92885-7"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003081-197106000-00024"},{"key":"e_1_2_1_4_2","unstructured":"World Health Organization.Prevention of Rh sensitization.WHO Technical Report Series No. 468;1971."},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1537-2995.1971.tb04424.x"},{"key":"e_1_2_1_6_2","first-page":"525","article-title":"Evaluation of methods for detection and quantitation of fetal cells and their effect on RhIgG usage","volume":"76","author":"Polesky HF","year":"1981","journal-title":"Am J Clin Pathol"},{"key":"e_1_2_1_7_2","first-page":"146","article-title":"Identification par des s\u00e9rums incomplets d' h\u00e9maties p\u0155esentes \u00e0 L' \u00e9tat de traces dans des m\u00e9langes globulaires","volume":"27","author":"Helderweirt G","year":"1960","journal-title":"Revue Beige de Pathologie et de Medecine Experimentale"},{"key":"e_1_2_1_8_2","first-page":"326","volume-title":"Technical Manual","author":"Miller WV","year":"1977"},{"key":"e_1_2_1_9_2","first-page":"10","article-title":"Fetales h\u00e4moglobin und fetale erythrozyten","volume":"53","author":"Kleihauer E.","year":"1966","journal-title":"Arch Kinderheilk"},{"key":"e_1_2_1_10_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF01481043"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003081-197109000-00013"},{"key":"e_1_2_1_12_2","first-page":"329","volume-title":"Blood transfusion in clinical medicine","author":"Mollison PL.","year":"1979"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.2.5300.303"},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1093\/ajcp\/46.1.36"},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.4.5624.139"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.2.5910.75"},{"key":"e_1_2_1_17_2","first-page":"1245","article-title":"The pathogenesis and prevention of Rh immunization","volume":"97","author":"Zipursky A","year":"1967","journal-title":"Can Med Assoc J"},{"key":"e_1_2_1_18_2","first-page":"34","volume-title":"Standards for Blood Banks and Transfusion Services","author":"Oberman HA","year":"1981"},{"key":"e_1_2_1_19_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1537-2995.1971.tb04396.x"},{"key":"e_1_2_1_20_2","unstructured":"AscariWQ O'ConnorRR PollackW.Massive feto\u2010maternal hemorrhage: detection quantitation and prophylactic measures to insure Rh immune suppression. Printed by Ortho Research Foundation Raritan N.J.Presented at the American Association of Blood Banks Annual Meeting San Francisco California October 2630 1970."}],"container-title":["Transfusion"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1046%2Fj.1537-2995.1982.22683068604.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1046\/j.1537-2995.1982.22683068604.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,2]],"date-time":"2023-11-02T02:09:20Z","timestamp":1698890960000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1046\/j.1537-2995.1982.22683068604.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1982,11,12]]},"references-count":19,"journal-issue":{"issue":"6","published-print":{"date-parts":[[1982,11,12]]}},"alternative-id":["10.1046\/j.1537-2995.1982.22683068604.x"],"URL":"https:\/\/doi.org\/10.1046\/j.1537-2995.1982.22683068604.x","archive":["Portico"],"relation":{},"ISSN":["0041-1132","1537-2995"],"issn-type":[{"value":"0041-1132","type":"print"},{"value":"1537-2995","type":"electronic"}],"subject":[],"published":{"date-parts":[[1982,11,12]]}}}