{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,31]],"date-time":"2025-10-31T13:50:56Z","timestamp":1761918656785},"reference-count":21,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2003,3,12]],"date-time":"2003-03-12T00:00:00Z","timestamp":1047427200000},"content-version":"vor","delay-in-days":11,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Transfusion"],"published-print":{"date-parts":[[2003,3]]},"abstract":"<jats:p> <jats:bold>BACKGROUND<\/jats:bold> : The objective was to apply statistical analysis to the false passes and fails that occur with the primary and secondary Hb\u2010screening methods used at blood\u2010donor sessions.<\/jats:p><jats:p> <jats:bold>STUDY DESIGN AND METHODS<\/jats:bold>\n          : Venous samples from 1513 potential donors who had undergone primary CuSO\n          <jats:sub>4<\/jats:sub> screening using capillary blood (Hb cut\u2010offs: women, 125 g\/L; men, 135 g\/L) were tested at the session by a secondary method (HemoCue; cut\u2010offs: women, 120 g\/L; men, 130 g\/L) and again at the base laboratory using another system (Beckman Coulter General S system), which generated the \u201ctrue\u201d Hb value.<\/jats:p><jats:p> <jats:bold>RESULTS<\/jats:bold>\n          : False\u2010pass and \u2010fail rates for women and men, respectively, were 11.2 and 6.3 percent (women) and 5.2 and 1.8 percent (men) for CuSO\n          <jats:sub>4<\/jats:sub>\n          ; 1.9 and 3.7 percent (women) and 1.5 and 0.4 percent (men) for HemoCue; and 2.7 and 2.4 percent (women) and 1.8 and 0.2 percent (men) for a combined procedure that mimicked current practice of only testing CuSO\n          <jats:sub>4<\/jats:sub> fails by HemoCue.<\/jats:p><jats:p> <jats:bold>CONCLUSION<\/jats:bold>\n          : CuSO\n          <jats:sub>4<\/jats:sub> Hb screening gives large numbers of false passes, particularly in women. Using venous samples, the majority correctly pass at the lower HemoCue cut\u2010offs. The current dual\u2010testing policy appears convenient for donor sessions, but because small percentages of false passes and fails represent large numbers of donors, every effort should be made to improve the accuracy of Hb screening.<\/jats:p>","DOI":"10.1046\/j.1537-2995.2003.00316.x","type":"journal-article","created":{"date-parts":[[2004,12,29]],"date-time":"2004-12-29T20:57:42Z","timestamp":1104353862000},"page":"400-404","source":"Crossref","is-referenced-by-count":40,"title":["Statistical analysis of inappropriate results from current Hb screening methods for blood donors"],"prefix":"10.1111","volume":"43","author":[{"given":"Virge","family":"James","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Keith F.","family":"Jones","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elizabeth M.","family":"Turner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert J.","family":"Sokol","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2003,3,12]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1016\/S0021-9258(18)56470-X","article-title":"Calculation of hemoglobin from blood specific gravities.","volume":"183","author":"Van Slyke DD","year":"1950","journal-title":"J Biol Chem"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0887-7963(05)80052-5"},{"key":"e_1_2_6_4_2","unstructured":"Mollison PL Engelfriet CP Contreras M. Blood Transfusion in clinical medicine 10th ed. Oxford: Blackwell Science 1997:1\u20108."},{"key":"e_1_2_6_5_2","doi-asserted-by":"crossref","first-page":"526","DOI":"10.1093\/clinchem\/32.3.526","article-title":"Evaluation of \u2018HemoCue\u2019, a new device for determining hemoglobin.","volume":"32","author":"Von Schenck H","year":"1986","journal-title":"Clin Chem"},{"key":"e_1_2_6_6_2","doi-asserted-by":"crossref","first-page":"2307","DOI":"10.1093\/clinchem\/33.12.2307","article-title":"Determination of total hemoglobin in whole blood: further tests of the \u2018HemoCue\u2019 method.","volume":"33","author":"Zwart A","year":"1987","journal-title":"Clin Chem"},{"key":"e_1_2_6_7_2","unstructured":"Cochran WG. Sampling techniques 3rd ed. Chichester: John Wiley and Sons 1977:107\u20109."},{"key":"e_1_2_6_8_2","unstructured":"Kish L. Survey sampling. Chichester: John Wiley and Sons 1995:80\u20102."},{"key":"e_1_2_6_9_2","unstructured":"Guidelines for the Blood Transfusion Services in the United Kingdom 5th ed. London: The Stationary Office 2001:26."},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2141.2000.01878.x"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.3109\/00365518809085796"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1537-2995.1997.37697335167.x"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-3148.1994.tb00275.x"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-3148.1997.d01-34.x"},{"issue":"1","key":"e_1_2_6_15_2","first-page":"41","article-title":"HemoCue haemoglobin estimation on venous blood samples of donors who fail the copper sulphate screening tests leads to the gain of many units which would otherwise have been lost (Abstract).","volume":"8","author":"Rushambuza FG","year":"1998","journal-title":"Transfus Med"},{"issue":"1","key":"e_1_2_6_16_2","first-page":"41","article-title":"Accuracy of Hemo\u2010 Cue venous blood haemoglobin estimations at blood donor sessions (Abstract).","volume":"8","author":"Rushambuza FG","year":"1998","journal-title":"Transfus Med"},{"issue":"1","key":"e_1_2_6_17_2","first-page":"54","article-title":"A local quality assessment scheme for haemoglobin screening at donor sessions (Abstract).","volume":"2","author":"Stivala JFA","year":"1992","journal-title":"Transfus Med"},{"key":"e_1_2_6_18_2","first-page":"995","article-title":"Utility of HemoCue in estimation of hemoglobin against standard blood cell counter method.","volume":"47","author":"Prakash S","year":"1999","journal-title":"J Assoc Physicians India"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.1590\/S1516-31801999000300003"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.294.6582.1263"},{"issue":"1","key":"e_1_2_6_21_2","first-page":"45","article-title":"Hb determination by HemoCue at donor sessions\u2014reliability of performance (Abstract).","volume":"11","author":"Boulton F","year":"2001","journal-title":"Transfus Med"},{"key":"e_1_2_6_22_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1423-0410.1986.tb04850.x"}],"container-title":["Transfusion"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1046%2Fj.1537-2995.2003.00316.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1046%2Fj.1537-2995.2003.00316.x","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1046\/j.1537-2995.2003.00316.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,14]],"date-time":"2023-10-14T17:05:31Z","timestamp":1697303131000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1046\/j.1537-2995.2003.00316.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2003,3]]},"references-count":21,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2003,3]]}},"alternative-id":["10.1046\/j.1537-2995.2003.00316.x"],"URL":"https:\/\/doi.org\/10.1046\/j.1537-2995.2003.00316.x","archive":["Portico"],"relation":{},"ISSN":["0041-1132","1537-2995"],"issn-type":[{"value":"0041-1132","type":"print"},{"value":"1537-2995","type":"electronic"}],"subject":[],"published":{"date-parts":[[2003,3]]}}}