{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:53:28Z","timestamp":1790816008744,"version":"4.1.0"},"reference-count":42,"publisher":"Wiley","issue":"s10","license":[{"start":{"date-parts":[[2004,10,12]],"date-time":"2004-10-12T00:00:00Z","timestamp":1097539200000},"content-version":"vor","delay-in-days":11,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Cardiovasc electrophysiol"],"published-print":{"date-parts":[[2004,10]]},"abstract":"<jats:p>The use of cryoablation in the electrophysiology lab provides some distinct advantages not seen with conventional radiofrequency ablation. Ice mapping allows a functional assessment of a putative ablation site prior to the formation of a permanent lesion. This provides a distinct advantage adjacent to the AV node for para\u2010hisian pathways and difficult cases of AVNRT. Cryoablation also produces minimal endothelial disruption and thrombus formation and causes no collagen shrinkage. This is likely advantageous when ablation is required within venous structures. There is also mounting experimental evidence that cryoablation is safe adjacent to the arterial system, especially within the middle cardiac vein or distal coronary sinus. As the technology evolves and further iterations of the catheter proceed, the role for this new but well\u2010established technology is likely to grow.<\/jats:p>","DOI":"10.1046\/j.1540-8167.2004.15106.x","type":"journal-article","created":{"date-parts":[[2004,12,23]],"date-time":"2004-12-23T22:11:05Z","timestamp":1103839865000},"source":"Crossref","is-referenced-by-count":59,"title":["Cryoablation:"],"prefix":"10.1111","volume":"15","author":[{"given":"ALLAN C.","family":"SKANES","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"GEORGE","family":"KLEIN","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"ANDREW","family":"KRAHN","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"RAYMOND","family":"YEE","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2004,10,12]]},"reference":[{"key":"e_1_2_7_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(84)80027-3"},{"key":"e_1_2_7_3_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1985.tb05874.x"},{"key":"e_1_2_7_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(87)80023-2"},{"key":"e_1_2_7_5_2","doi-asserted-by":"publisher","DOI":"10.1006\/cryo.1998.2115"},{"key":"e_1_2_7_6_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.0000058706.82623.A1"},{"key":"e_1_2_7_7_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.59.2.364"},{"key":"e_1_2_7_8_2","first-page":"2931","article-title":"Safety and efficacy of cryoablation in the canine coronary sinus","volume":"104","author":"Yagi T","year":"2001","journal-title":"Circulation"},{"key":"e_1_2_7_9_2","first-page":"549","article-title":"Cryoablation of accessory pathways via the distal coronary sinus: Safety and feasibility in a swine model","volume":"25","author":"Skanes AC","year":"2002","journal-title":"Pacing Clin Electrophysiol"},{"key":"e_1_2_7_10_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1540-8167.2002.01082.x"},{"key":"e_1_2_7_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2004.02.022"},{"key":"e_1_2_7_12_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1999.tb00353.x"},{"key":"e_1_2_7_13_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1540-8167.2003.03076.x"},{"key":"e_1_2_7_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2004.02.020"},{"key":"e_1_2_7_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(03)00975-5"},{"key":"e_1_2_7_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(94)90726-9"},{"key":"e_1_2_7_17_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8159.1998.tb00131.x"},{"key":"e_1_2_7_18_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.90.3.1124"},{"key":"e_1_2_7_19_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.86.6.1743"},{"key":"e_1_2_7_20_2","first-page":"574","article-title":"Use of cryoenergy for ablation of arrhythmias in children and adolescents: A single centre experience","volume":"19","author":"Sturmer ML","year":"2003","journal-title":"Can J Cardiol"},{"key":"e_1_2_7_21_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.90.3.1279"},{"key":"e_1_2_7_22_2","doi-asserted-by":"crossref","first-page":"1644","DOI":"10.1093\/eurheartj\/14.12.1644","article-title":"The Multicentre European Radiofrequency Survey (MERFS): Complications of radiofrequency catheter ablation of arrhythmias. The Multicentre European Radiofrequency Survey (MERFS) investigators of the Working Group on Arrhythmias of the European Society of Cardiology","volume":"14","author":"Hindricks G","year":"1993","journal-title":"Eur Heart J"},{"key":"e_1_2_7_23_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1540-8167.2002.01160.x"},{"key":"e_1_2_7_24_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.102.21.2565"},{"key":"e_1_2_7_25_2","first-page":"117","article-title":"Percutaneous cryoablation pulmonary vein isolation to treat atrial fibrillation","volume":"25","author":"Wong T","year":"2002","journal-title":"Pacing Clin Electrophysiol"},{"key":"e_1_2_7_26_2","first-page":"360","article-title":"Catheter isolation of the pulmonary veins by cryothermal ablation: Preliminary results","volume":"25","author":"Tondo C","year":"2002","journal-title":"Pacing Clin Electrophysiol"},{"key":"e_1_2_7_27_2","doi-asserted-by":"publisher","DOI":"10.1023\/A:1026525901853"},{"key":"e_1_2_7_28_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1540-8167.2001.00887.x"},{"key":"e_1_2_7_29_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.101.14.1736"},{"key":"e_1_2_7_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(02)01893-4"},{"key":"e_1_2_7_31_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1540-8167.2001.00563.x"},{"key":"e_1_2_7_32_2","doi-asserted-by":"publisher","DOI":"10.1115\/1.2798281"},{"key":"e_1_2_7_33_2","doi-asserted-by":"publisher","DOI":"10.5435\/00124635-200009000-00004"},{"key":"e_1_2_7_34_2","first-page":"195","article-title":"The thermal shrinkage process of collagen fibres as revealed by polarization optical analysis of topooptical staining reactions","volume":"15","author":"Deak G","year":"1967","journal-title":"Acta Morphol Acad Sci Hung"},{"key":"e_1_2_7_35_2","doi-asserted-by":"publisher","DOI":"10.1002\/lsm.1900020101"},{"key":"e_1_2_7_36_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.0000091081.19465.F1"},{"key":"e_1_2_7_37_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(03)00788-5"},{"key":"e_1_2_7_38_2","first-page":"3122","article-title":"Initial experience with a novel circular cryoablation catheter for pulmonary vein isolation","volume":"106","author":"Skanes AC","year":"2002","journal-title":"Circulation"},{"key":"e_1_2_7_39_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1540-8167.2003.02334.x"},{"key":"e_1_2_7_40_2","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-138-8-200304150-00010"},{"key":"e_1_2_7_41_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.102.16.1879"},{"key":"e_1_2_7_42_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1540-8167.2002.00957.x"},{"key":"e_1_2_7_43_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1540-8167.2003.90404.x"}],"container-title":["Journal of Cardiovascular Electrophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1046%2Fj.1540-8167.2004.15106.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1046\/j.1540-8167.2004.15106.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,27]],"date-time":"2023-09-27T02:00:35Z","timestamp":1695780035000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1046\/j.1540-8167.2004.15106.x"}},"subtitle":["Potentials and Pitfalls"],"short-title":[],"issued":{"date-parts":[[2004,10]]},"references-count":42,"journal-issue":{"issue":"s10","published-print":{"date-parts":[[2004,10]]}},"alternative-id":["10.1046\/j.1540-8167.2004.15106.x"],"URL":"https:\/\/doi.org\/10.1046\/j.1540-8167.2004.15106.x","archive":["Portico"],"relation":{},"ISSN":["1045-3873","1540-8167"],"issn-type":[{"value":"1045-3873","type":"print"},{"value":"1540-8167","type":"electronic"}],"subject":[],"published":{"date-parts":[[2004,10]]}}}