{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T06:04:22Z","timestamp":1760249062059},"reference-count":31,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2003,3,6]],"date-time":"2003-03-06T00:00:00Z","timestamp":1046908800000},"content-version":"vor","delay-in-days":64,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Echocardiography"],"published-print":{"date-parts":[[2003,1]]},"abstract":"<jats:p> <jats:italic>The aim of the study was to evaluate the accuracy of intermittent, harmonic power Doppler (HPD) during intravenous Levovist infusion in identifying myocardial perfusion abnormalities in patients with recent infarction. Fifty\u2010five patients with first acute myocardial infarction, successfully treated by primary PTCA, were studied after 1 month by myocardial contrast echocardiography (MCE), <jats:sup>99m<\/jats:sup>Tc tetrofosmin single photon emission computed tomography (SPECT), and low dose dobutamine echocardiography (DE). Scoring myocardial perfusion as normal, moderately, or severely reduced; MCE and SPECT were in agreement in 71% of segments<\/jats:italic>\n          <jats:styled-content>\n              <jats:italic>(k = 0.414)<\/jats:italic>\n            <\/jats:styled-content>\n          <jats:italic>. Discordance was mainly due to ventricular walls with normal enhancement by MCE and moderate perfusion abnormalities by SPECT. Scoring perfusion as present or absent, the agreement significantly improved up to<\/jats:italic>\n          <jats:styled-content>\n              <jats:italic>86% (k = 0.59)<\/jats:italic>\n            <\/jats:styled-content>\n          <jats:italic>. Sensitivity and specificity of HPD for identifying SPECT perfusion defects were 63% and 93%, respectively. The agreement between MCE and SPECT was higher<\/jats:italic>\n          <jats:styled-content>\n              <jats:italic>(85%, k = 0.627)<\/jats:italic>\n            <\/jats:styled-content>\n          <jats:italic>in patients with anterior infarction. An improvement in regional contractile function was noted after dobutamine in 79 dysfunctional segments. A normal perfusion or a moderate perfusion defect by MCE were detected in 71 of 79 of these segments, while a severe perfusion defect was observed in 59 of 85 ventricular segments without dobutamine\u2010induced wall\u2010motion improvement. Sensitivity and specificity by HPD in detecting segments with contractile reserve were 90% and 69%, respectively. Thus, intermittent HPD during Levovist infusion allows myocardial perfusion abnormalities to be detected in patients with recent infarction. This method has a limited sensitivity but a high specificity in detecting SPECT perfusion defects, and a good sensitivity but a limited specificity in detecting contractile reserve. (ECHOCARDIOGRAPHY, Volume 20, January 2003)<\/jats:italic> <\/jats:p>","DOI":"10.1046\/j.1540-8175.2003.00005.x","type":"journal-article","created":{"date-parts":[[2003,3,11]],"date-time":"2003-03-11T15:40:36Z","timestamp":1047397236000},"page":"37-45","source":"Crossref","is-referenced-by-count":3,"title":["Assessment of Myocardial Perfusion with Intravenous Contrast Echocardiography:"],"prefix":"10.1111","volume":"20","author":[{"given":"Caterina","family":"Palagi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giovanna","family":"Mengozzi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniele","family":"Rovai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Duccio","family":"Volterrani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rita","family":"Dell'Anna","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Davide","family":"Giorgi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anna Sonia","family":"Petronio","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vitantonio Di","family":"Bello","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mario","family":"Mariani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2003,3,6]]},"reference":[{"key":"e_1_2_7_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(96)00575-X"},{"key":"e_1_2_7_3_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.96.3.785"},{"key":"e_1_2_7_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(98)00373-8"},{"key":"e_1_2_7_5_2","doi-asserted-by":"publisher","DOI":"10.1136\/heart.83.5.518"},{"key":"e_1_2_7_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8175.1997.tb00692.x"},{"key":"e_1_2_7_7_2","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1016\/S0002-8703(00)90233-3","article-title":"Power Doppler harmonic imaging: A feasibility study of a new technique for the assessment of myocardial perfusion","volume":"139","author":"Senior R","year":"2000","journal-title":"Am Heart J"},{"key":"e_1_2_7_8_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.102.1.55"},{"key":"e_1_2_7_9_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8175.2000.tb01165.x"},{"key":"e_1_2_7_10_2","first-page":"2","volume-title":"Handbook of Contrast Echocardiography. Left Ventricular Function and Myocardial Perfusion","author":"Becher H","year":"2000"},{"key":"e_1_2_7_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0894-7317(89)80014-8"},{"key":"e_1_2_7_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0894-7317(96)90470-8"},{"key":"e_1_2_7_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(90)90236-I"},{"key":"e_1_2_7_14_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.91.3.663"},{"key":"e_1_2_7_15_2","first-page":"1","article-title":"Contrast echocardiography for myocardial perfusion imaging using intravenous agents: Progress and promises","volume":"1","author":"Amyot R","year":"2001","journal-title":"Eur J Echocardiography"},{"key":"e_1_2_7_16_2","first-page":"1096","article-title":"Microvascular integrity indicates myocellular viability in patients with recent myocardial infarction. New insight using myocardial contrast echocardiography","volume":"23","author":"Ragosta M","year":"1994","journal-title":"Circulation"},{"key":"e_1_2_7_17_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF03164852"},{"key":"e_1_2_7_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(00)01179-7"},{"key":"e_1_2_7_19_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.97.5.473"},{"key":"e_1_2_7_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(00)01046-9"},{"key":"e_1_2_7_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(00)01358-8"},{"key":"e_1_2_7_22_2","doi-asserted-by":"publisher","DOI":"10.1053\/euhj.2001.2604"},{"key":"e_1_2_7_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(95)80022-K"},{"key":"e_1_2_7_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(97)89334-4"},{"key":"e_1_2_7_25_2","doi-asserted-by":"publisher","DOI":"10.1093\/oxfordjournals.eurheartj.a015342"},{"key":"e_1_2_7_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(97)00001-6"},{"key":"e_1_2_7_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(98)00483-5"},{"key":"e_1_2_7_28_2","first-page":"363","article-title":"Detecting myocardial salvage after primary PTCA: Early myocardial contrast echocardiography versus delayed sestamibi perfusion imaging","volume":"40","author":"Sciagr\u00e0 R","year":"1999","journal-title":"J Nucl Med"},{"key":"e_1_2_7_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(98)00436-7"},{"key":"e_1_2_7_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(01)01803-3"},{"key":"e_1_2_7_31_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.104.3.352"},{"key":"e_1_2_7_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(01)01317-1"}],"container-title":["Echocardiography"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1046%2Fj.1540-8175.2003.00005.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1046\/j.1540-8175.2003.00005.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,13]],"date-time":"2023-10-13T06:30:11Z","timestamp":1697178611000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1046\/j.1540-8175.2003.00005.x"}},"subtitle":["Comparison with <sup>99<\/sup>Tc\u2010Tetrofosmin Single Photon Emission Computed Tomography and Dobutamine Echocardiography"],"short-title":[],"issued":{"date-parts":[[2003,1]]},"references-count":31,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2003,1]]}},"alternative-id":["10.1046\/j.1540-8175.2003.00005.x"],"URL":"https:\/\/doi.org\/10.1046\/j.1540-8175.2003.00005.x","archive":["Portico"],"relation":{},"ISSN":["0742-2822","1540-8175"],"issn-type":[{"value":"0742-2822","type":"print"},{"value":"1540-8175","type":"electronic"}],"subject":[],"published":{"date-parts":[[2003,1]]}}}