{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T23:17:09Z","timestamp":1772234229120,"version":"3.50.1"},"reference-count":39,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2003,2,28]],"date-time":"2003-02-28T00:00:00Z","timestamp":1046390400000},"content-version":"vor","delay-in-days":27,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Interven Cardiology"],"published-print":{"date-parts":[[2003,2]]},"abstract":"<jats:p> <jats:italic>The cutting balloon is a new device for coronary angioplasty, that, by the combination of incision and dilatation of the plaque, is believed to be promising for treatment of in\u2010stent restenosis. The purpose of the study was to evaluate the safety and efficacy of CBA. We reviewed the immediate and 6\u2010month follow\u2010up angiographic and clinical outcome of 147 patients (109 men and 38 women) with a mean age of<\/jats:italic>\n          <jats:styled-content>\n              <jats:italic>67.3 \u00b1 10<\/jats:italic>\n            <\/jats:styled-content>\n          <jats:italic>undergoing this procedure at eight interventional centers in Austria. The target lesions treated with CBA were in\u2010stent restenosis in 61% of patients, stenosis after balloon angioplasty in 8% of patients, and native lesions in 33% of patients. Sixty\u2010five percent of the patients included had multivessel disease. Lesion type was A in 18% of patients, B1 in 31% of patients, B2 in 39% of patients, and C in 12% of patients. The degree of stenosis was<\/jats:italic>\n          <jats:styled-content>\n              <jats:italic>87%\u00b1 9%,<\/jats:italic>\n            <\/jats:styled-content>\n          <jats:italic>the length of the target lesion treated with CBA was<\/jats:italic>\n          <jats:styled-content>\n              <jats:italic>8.8 \u00b1 5.1 mm<\/jats:italic>\n            <\/jats:styled-content>. <jats:italic>Target vessel was left circumflex artery in 22 cases, right coronary artery in 36 cases, and left anterior descending artery in 89 cases. The overall procedural success rate was 90.5%. \u201cStand\u2010alone\u201d CBA was performed in 63% of patients, the procedure was combined with coronary stenting in 16% of patients, and with balloon angioplasty in 21% of patients. Coronary complications occurred in eight cases (5.4%) with coronary dissection in seven (total dissection rate of 4.7%) and urgent bypass surgery in one case (0.7%). No further complications such as death, occlusion, or perforation of coronary arteries, embolization, or thrombosis were observed. Six\u2010month clinical follow\u2010up revealed q\u2010wave myocardial infarction in 2.7% of patients, aortocoronary bypass surgery in 8.5% of patients, and repeated percutaneous coronary intervention in 17% of patients (11.5% with stenting). Six\u2010month angiographic follow\u2010up of patients with recurrent angina showed target lesion restenosis (&gt;50% diameter stenosis) in 14% of patients, late lumen loss with \u226450% diameter stenosis in 6% of patients and progression of \u201cother than target\u201d lesions with &gt;50% diameter stenosis in 14% of patients. This series demonstrates the safety and feasibility of cutting balloon angioplasty in patients with complex coronary artery disease and in\u2010stent restenosis.<\/jats:italic> (J Interven Cardiol 2003;16:15\u201321)<\/jats:p>","DOI":"10.1046\/j.1540-8183.2003.08010.x","type":"journal-article","created":{"date-parts":[[2003,3,12]],"date-time":"2003-03-12T02:39:58Z","timestamp":1047436798000},"page":"15-21","source":"Crossref","is-referenced-by-count":11,"title":["Clinical and Angiographic Outcome after Cutting Balloon Angioplasty"],"prefix":"10.1111","volume":"16","author":[{"given":"JOHANN","family":"AUER","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"EDWIN","family":"MAURER","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"ROBERT","family":"BERENT","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"HERBERT","family":"MAYR","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"CHRISTIAN","family":"PUNZENGRUBER","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"THOMAS","family":"WEBER","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"ELISABETH","family":"LASSNIG","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"BERND","family":"EBER","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"name":"Austrian Cutting Balloon Registry","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2003,2,28]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM198703193161201"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM199408253310802"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJM199408253310801"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(93)90813-R"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(92)90438-S"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.95.8.1998"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(93)90241-R"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.90.6.2716"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1002\/1522-726X(200008)50:4<480::AID-CCD24>3.0.CO;2-2"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.1810320219"},{"key":"e_1_2_6_12_2","first-page":"I 308","article-title":"The efficacy of cutting balloon for in\u2010stent restenosis compared with conventional balloon angioplasty","volume":"100","author":"Mizobe M","year":"1999","journal-title":"Circulation"},{"key":"e_1_2_6_13_2","first-page":"70","article-title":"Comparison of angiographic and clinical outcome after cutting balloon and conventional balloon angioplasty in vessels smaller than 3 mm in diameter: A randomized trial","volume":"10","author":"Ergene O","year":"1998","journal-title":"J Invasive Cardiol"},{"key":"e_1_2_6_14_2","first-page":"193","article-title":"Evaluation of mechanism of cutting balloon for in\u2010stent restenosis by intravasculr ultrasound","volume":"82","author":"Muramatsu T","year":"1998","journal-title":"Am J Cardiol"},{"key":"e_1_2_6_15_2","first-page":"62A","article-title":"Treatment of in\u2010stent restenosis: short and midterm results of a pilot randomized study between balloon and Cutting Balloon","volume":"33","author":"Chevalier B","year":"1999","journal-title":"J Am Coll Cardiol"},{"key":"e_1_2_6_16_2","unstructured":"KinoshitaS SuzukiT HosokawaH et al.A comparison of initial and long\u2010term results of cutting balloon and POBA in the treatment of in\u2010stent restenosis.Jpn Intervent Meeting abstract I\u2010M029."},{"key":"e_1_2_6_17_2","first-page":"992","article-title":"The efficacy of cutting balloon angioplasty for in\u2010stent restenosis: Comparison with plain old balloon angioplasty","volume":"5","author":"Tahara H","year":"1999","journal-title":"Jpn Circ"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1067\/mhj.2001.119129"},{"key":"e_1_2_6_19_2","first-page":"25A","article-title":"Cutting balloon catheter: Clinical considerations and challenges","volume":"8","author":"Katenkamp M","year":"1996","journal-title":"J Invasive Cardiol"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-0304(199808)44:4<420::AID-CCD13>3.0.CO;2-M"},{"key":"e_1_2_6_21_2","first-page":"9A","article-title":"Multicentric non\u2010randomized experience with cutting balloon","volume":"8","author":"Bonan R","year":"1996","journal-title":"J Invasive Cardiol"},{"key":"e_1_2_6_22_2","first-page":"12A","article-title":"Angiographic and clinical outcome after cutting balloon angioplasty","volume":"8","author":"Popma JJ","year":"1996","journal-title":"J Invasive Cardiol"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1136\/hrt.77.4.350"},{"key":"e_1_2_6_24_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-0304(199706)41:2<179::AID-CCD16>3.0.CO;2-L"},{"key":"e_1_2_6_25_2","doi-asserted-by":"publisher","DOI":"10.1002\/clc.4960200511"},{"key":"e_1_2_6_26_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-0304(199706)41:2<179::AID-CCD16>3.0.CO;2-L"},{"key":"e_1_2_6_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(01)01458-9"},{"key":"e_1_2_6_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(01)01457-7"},{"key":"e_1_2_6_29_2","first-page":"231","article-title":"Cutting balloon angioplasty of ostial coronary lesions: Do we need the stent support?","volume":"114","author":"Colombo A","year":"1999","journal-title":"J Invasive Cardiol"},{"key":"e_1_2_6_30_2","first-page":"201","article-title":"Efficacy of cutting balloon angioplasty for lesions at the ostium of the coronary arteries","volume":"11","author":"Muramatsu T","year":"1999","journal-title":"J Invasive Cardiol"},{"key":"e_1_2_6_31_2","first-page":"290","volume-title":"The Interventional Cardiac Catheterization","author":"Kern MJ","year":"1966"},{"key":"e_1_2_6_32_2","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.1810320402"},{"key":"e_1_2_6_33_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.85.3.916"},{"key":"e_1_2_6_34_2","doi-asserted-by":"publisher","DOI":"10.1016\/0735-1097(92)90272-O"},{"key":"e_1_2_6_35_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9149(98)00165-9"},{"key":"e_1_2_6_36_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-0304(199808)44:4<449::AID-CCD20>3.0.CO;2-C"},{"key":"e_1_2_6_37_2","doi-asserted-by":"publisher","DOI":"10.1067\/mhj.2001.117321"},{"key":"e_1_2_6_38_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1522-726X(200004)49:4<410::AID-CCD13>3.0.CO;2-X"},{"key":"e_1_2_6_39_2","doi-asserted-by":"publisher","DOI":"10.1002\/1522-726X(200008)50:4<452::AID-CCD19>3.0.CO;2-W"},{"key":"e_1_2_6_40_2","first-page":"257","article-title":"Coronary stenting in clinical practice: Patient profile, immediate outcome, clinical and angiographic follow up in 243 consecutive patients","volume":"9","author":"Hennessy T","year":"1997","journal-title":"J Invas Cardiol"}],"container-title":["Journal of Interventional Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1046\/j.1540-8183.2003.08010.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,13]],"date-time":"2023-10-13T22:17:17Z","timestamp":1697235437000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1046\/j.1540-8183.2003.08010.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2003,2]]},"references-count":39,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2003,2]]}},"alternative-id":["10.1046\/j.1540-8183.2003.08010.x"],"URL":"https:\/\/doi.org\/10.1046\/j.1540-8183.2003.08010.x","archive":["Portico"],"relation":{},"ISSN":["0896-4327","1540-8183"],"issn-type":[{"value":"0896-4327","type":"print"},{"value":"1540-8183","type":"electronic"}],"subject":[],"published":{"date-parts":[[2003,2]]}}}