{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T20:24:14Z","timestamp":1792095854531,"version":"4.4.0"},"reference-count":36,"publisher":"Institution of Engineering and Technology (IET)","issue":"18","license":[{"start":{"date-parts":[[2021,2,17]],"date-time":"2021-02-17T00:00:00Z","timestamp":1613520000000},"content-version":"vor","delay-in-days":78,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"DOI":"10.13039\/501100003141","name":"Consejo Nacional de Ciencia y Tecnolog\u00eda","doi-asserted-by":"publisher","award":["S\u20103999"],"award-info":[{"award-number":["S\u20103999"]}],"id":[{"id":"10.13039\/501100003141","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100003141","name":"Consejo Nacional de Ciencia y Tecnolog\u00eda","doi-asserted-by":"publisher","award":["293557"],"award-info":[{"award-number":["293557"]}],"id":[{"id":"10.13039\/501100003141","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["ietresearch.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["IET Power Electronics"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:p>This study presents an active anti\u2010islanding technique for distributed power generator systems. The proposed scheme is based on the Sandia voltage shift (SVS) technique, which is characterised by a small non\u2010detection zone (NDZ) and by an acceptable solution to the trade\u2010off between the output power quality and the effectiveness of islanding detection. The proposed technique has the advantage to improve the NDZ and to reduce the anti\u2010islanding detection times. This is due to the exponential\u2010product modification made in the positive feedback to inject current, thereby making the response faster than SVS. Additionally, a self\u2010adaptive gain is considered to achieve a low total harmonic distortion at different power levels. Moreover, the proposed scheme has been validated with theoretical and numerical analysis and experimental results. Finally, the behaviour and performance of the proposed technique are compared with other recent techniques.<\/jats:p>","DOI":"10.1049\/iet-pel.2020.0735","type":"journal-article","created":{"date-parts":[[2021,2,17]],"date-time":"2021-02-17T21:50:37Z","timestamp":1613598637000},"page":"4226-4234","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["Modified Sandia voltage shift anti\u2010islanding scheme for distributed power generator systems"],"prefix":"10.1049","volume":"13","author":[{"given":"Erick","family":"Vazquez","sequence":"first","affiliation":[{"name":"Applied Mathematics Division Instituto Potosino de Investigaci\u00f3n Cient\u00edfica y Tecnol\u00f3gica Camino a la Presa San Jos\u00e9 Lomas 4a. secc. ZC. 78216 San Luis Potos\u00ed Mexico"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6363-513X","authenticated-orcid":false,"given":"Nimrod","family":"Vazquez","sequence":"additional","affiliation":[{"name":"Electronics Engineering Department Tecnol\u00f3gico Nacional de M\u00e9xico\/Instituto Tecnol\u00f3gico de Celaya Av. Tecnol\u00f3gico y A. Garc\u00eda Cubas S\/N A.P. 57 ZC 38010 Celaya Mexico"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ricardo","family":"Femat","sequence":"additional","affiliation":[{"name":"Applied Mathematics Division Instituto Potosino de Investigaci\u00f3n Cient\u00edfica y Tecnol\u00f3gica Camino a la Presa San Jos\u00e9 Lomas 4a. secc. ZC. 78216 San Luis Potos\u00ed Mexico"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"265","published-online":{"date-parts":[[2021,2,17]]},"reference":[{"key":"e_1_2_10_2_2","doi-asserted-by":"publisher","DOI":"10.1109\/TIA.2017.2680409"},{"key":"e_1_2_10_3_2","unstructured":"IEEE Std 929: \u2018IEEE recommended practice for utility interface of photovoltaic (PV) systems\u2019 (Institute of Electrical and Electronics Engineers 2000)"},{"key":"e_1_2_10_4_2","unstructured":"IEEE Standards Coordinating C. 21: \u2018IEEE guide for design operation and integration of distributed resource island systems with electric power systems\u2019 (Institute of Electrical and Electronics Engineers 2011)"},{"key":"e_1_2_10_5_2","doi-asserted-by":"crossref","unstructured":"Guha B. Haddad R.J. Kalaani Y.: \u2018Anti\u2010islanding techniques for inverter\u2010based distributed generation systems \u2013 a survey\u2019.Conf. Proc. IEEE SOUTHEASTCON\u2019 Fort Lauderdale FL USA 2015 pp.1\u20139","DOI":"10.1109\/SECON.2015.7133045"},{"key":"e_1_2_10_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.apenergy.2010.05.014"},{"key":"e_1_2_10_7_2","doi-asserted-by":"crossref","unstructured":"Ropp M.E. Aaker K. Haigh J. et al.: \u2018Using power line carrier communications to prevent islanding\u2019.Conf. Record of the IEEE Photovoltaic Specialists Conf. Anchorage AK USA 2000 pp.1675\u20131678","DOI":"10.1109\/PVSC.2000.916224"},{"key":"e_1_2_10_8_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2013.2284670"},{"key":"e_1_2_10_9_2","doi-asserted-by":"crossref","unstructured":"Pena P. Etxegarai A. Valverde L. et al.: \u2018Synchrophasor\u2010based anti\u2010islanding detection\u2019.2013 IEEE Grenoble Conf. PowerTech (POWERTECH 2013) 2013 pp.1\u20136","DOI":"10.1109\/PTC.2013.6652280"},{"key":"e_1_2_10_10_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2013.2271317"},{"key":"e_1_2_10_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.epsr.2014.01.016"},{"key":"e_1_2_10_12_2","doi-asserted-by":"crossref","unstructured":"Das P. Ghore S. Biswal M.: \u2018Comparative assessment of various islanding detection methods for AC and DC microgrid\u2019.2020 1st Int. Conf. on Power Control and Computing Technologies (ICPC2T 2020) Raipur India 2020 pp.396\u2013400","DOI":"10.1109\/ICPC2T48082.2020.9071520"},{"key":"e_1_2_10_13_2","doi-asserted-by":"crossref","unstructured":"Guha B. Haddad R.J. Kalaani Y.: \u2018A novel passive islanding detection technique for converter\u2010based distributed generation systems\u2019.2015 IEEE Power & Energy Society Innovative Smart Grid Technologies Conf. (ISGT) Washington DC USA 2015 pp.1\u20135","DOI":"10.1109\/ISGT.2015.7131907"},{"key":"e_1_2_10_14_2","doi-asserted-by":"publisher","DOI":"10.1109\/TIA.2017.2788433"},{"key":"e_1_2_10_15_2","doi-asserted-by":"publisher","DOI":"10.1109\/TSG.2014.2338736"},{"key":"e_1_2_10_16_2","doi-asserted-by":"crossref","unstructured":"Shi L. Wu F.: \u2018An islanding detection algorithm based on fuzzy adaptive phase drift control\u2019.2013 IEEE Int. Conf. on Information and Automation (ICIA) Yinchuan People's Republic of China 2013 pp.225\u2013229","DOI":"10.1109\/ICInfA.2013.6720300"},{"key":"e_1_2_10_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijepes.2012.04.003"},{"key":"e_1_2_10_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijepes.2012.08.020"},{"key":"e_1_2_10_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.rser.2013.06.047"},{"key":"e_1_2_10_20_2","doi-asserted-by":"crossref","unstructured":"ElNozahy M.S. El\u2010Saadany E.F. Salama M.M.A.: \u2018A robust wavelet\u2010ANN based technique for islanding detection\u2019.IEEE Power and Energy Society General Meeting\u2019 Detroit MI USA 2011 pp.1\u20138","DOI":"10.1109\/PES.2011.6039158"},{"key":"e_1_2_10_21_2","doi-asserted-by":"crossref","unstructured":"Park S. Kwon M. Choi S.: \u2018A new anti\u2010islanding method for indirect current control of grid connected inverter\u2019.2017 IEEE 3rd Int. Future Energy Electronics Conf. and ECCE Asia IFEEC\u2013 ECCE Asia 2017 Kaohsiung Taiwan 2017 pp.1230\u20131234","DOI":"10.1109\/IFEEC.2017.7992218"},{"key":"e_1_2_10_22_2","doi-asserted-by":"crossref","unstructured":"Varier R. Pindoriya N.M.: \u2018A novel active anti\u2010islanding protection scheme for grid\u2010interactive roof\u2010top solar PV system\u2019.2014 18th National Power Systems Conf. (NPSC 2014) Guwahati India 2015 pp.1\u20136","DOI":"10.1109\/NPSC.2014.7103797"},{"key":"e_1_2_10_23_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2013.2278792"},{"key":"e_1_2_10_24_2","doi-asserted-by":"publisher","DOI":"10.1109\/TSG.2014.2337751"},{"key":"e_1_2_10_25_2","doi-asserted-by":"publisher","DOI":"10.1109\/TIA.2015.2480847"},{"key":"e_1_2_10_26_2","doi-asserted-by":"publisher","DOI":"10.1109\/TIA.2014.2330063"},{"key":"e_1_2_10_27_2","doi-asserted-by":"publisher","DOI":"10.1049\/iet-gtd.2018.5636"},{"key":"e_1_2_10_28_2","doi-asserted-by":"publisher","DOI":"10.1109\/TEC.2018.2881737"},{"key":"e_1_2_10_29_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2018.2836663"},{"key":"e_1_2_10_30_2","doi-asserted-by":"crossref","unstructured":"Stevens J. Bonn R. Ginn J. et al.: \u2018Development and testing of an approach to anti\u2010islanding in utility\u2010interconnected photovoltaic systems\u2019 Other Inf.PBD 1 August 2000 2000 p.58","DOI":"10.2172\/759506"},{"key":"e_1_2_10_31_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2006.876980"},{"key":"e_1_2_10_32_2","doi-asserted-by":"publisher","DOI":"10.1109\/TEC.2012.2188529"},{"key":"e_1_2_10_33_2","doi-asserted-by":"crossref","unstructured":"Li Y. Hou M. Feng H. et al.: \u2018Composite islanding detection method based on the active frequency drift and voltage amplitude variation\u2019.Asia\u2010Pacific Power and Energy Engineering Conf. (APPEEC) Hong Kong People's Republic of China 2014","DOI":"10.1109\/APPEEC.2014.7066106"},{"key":"e_1_2_10_34_2","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2012.2219628"},{"key":"e_1_2_10_35_2","doi-asserted-by":"crossref","unstructured":"Singh J.K. Behera R.K.: \u2018Hysteresis current controllers for grid connected inverter: review and experimental implementation\u2019.Proc. 2018 IEEE Int. Conf. on Power Electronics Drives and Energy Systems (PEDES 2018) Chennai India 2018","DOI":"10.1109\/PEDES.2018.8707755"},{"key":"e_1_2_10_36_2","doi-asserted-by":"crossref","unstructured":"Jo J. Cha H.: \u2018Performance of anti\u2010islanding of an improved reactive power variation method based on positive feedback\u2019.2017 IEEE Energy Conversion Congress and Exposition (ECCE 2017) Cincinnati OH USA 2017 pp.4761\u20134765","DOI":"10.1109\/ECCE.2017.8096810"},{"key":"e_1_2_10_37_2","doi-asserted-by":"publisher","DOI":"10.1049\/joe.2018.8005"}],"container-title":["IET Power Electronics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1049\/iet-pel.2020.0735","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1049\/iet-pel.2020.0735","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/ietresearch.onlinelibrary.wiley.com\/doi\/pdf\/10.1049\/iet-pel.2020.0735","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T20:26:17Z","timestamp":1761683177000},"score":1,"resource":{"primary":{"URL":"https:\/\/ietresearch.onlinelibrary.wiley.com\/doi\/10.1049\/iet-pel.2020.0735"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,12]]},"references-count":36,"journal-issue":{"issue":"18","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["10.1049\/iet-pel.2020.0735"],"URL":"https:\/\/doi.org\/10.1049\/iet-pel.2020.0735","archive":["Portico"],"relation":{},"ISSN":["1755-4535","1755-4543"],"issn-type":[{"value":"1755-4535","type":"print"},{"value":"1755-4543","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,12]]},"assertion":[{"value":"2020-06-20","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-11-20","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-02-17","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}