{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T22:03:15Z","timestamp":1740175395853,"version":"3.37.3"},"reference-count":25,"publisher":"EDP Sciences","license":[{"start":{"date-parts":[[2022,11,11]],"date-time":"2022-11-11T00:00:00Z","timestamp":1668124800000},"content-version":"vor","delay-in-days":314,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100000266","name":"Engineering and Physical Sciences Research Council","doi-asserted-by":"publisher","award":["539270"],"award-info":[{"award-number":["539270"]}],"id":[{"id":"10.13039\/501100000266","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["SICOT-J"],"accepted":{"date-parts":[[2022,10,14]]},"published-print":{"date-parts":[[2022]]},"abstract":"<jats:p><jats:italic>Background<\/jats:italic>: Early failure of uncemented femoral stems associated with incorrect sizing is a known postoperative complication. Surgeons are often faced with the question of whether an uncemented stem of adequate stability or a larger-sized stem should be implanted, especially when the proximal femoral cancellous bone is adequate. The biomechanical effect of sub-optimal stem sizing in the femur remains unclear. This study investigated the mechanical behaviour of two sequential sized uncemented stems of the same type. <jats:italic>Methods<\/jats:italic>: Six laboratory models of synthetic non-osteoporotic femora were randomly divided into two groups and implanted with either a nominal or oversized uncemented hydroxyapatite-coated nonporous titanium collarless stem. Stiffness, uniaxial strain, and pattern of strain distribution were measured under an anatomical one-legged stance. <jats:italic>Results<\/jats:italic>: Oversized stems demonstrated a higher overall stiffness compared to nominal; however, this was not statistically significant. The nominal stem showed a higher strain in the neck and the proximal medial diaphyseal region. The oversized stem showed higher strains in the distal region around the implant tip. <jats:italic>Conclusion<\/jats:italic>: Opting to use a larger stem may potentially increase primary stability, thus allowing safer early mobility. However, higher stiffness may lead to stress shielding, bone loss, and thigh pain in the long term. In addition, strains in the diaphysis and the tip of the stem may predispose to periprosthetic fractures, especially in osteoporotic bones, making this a relatable aspect for users and biomechanical loading. Given the wide range of complex factors that need to be considered when choosing stem size in uncemented THA surgery, this study\u2019s results should be interpreted cautiously.<\/jats:p>","DOI":"10.1051\/sicotj\/2022043","type":"journal-article","created":{"date-parts":[[2022,11,11]],"date-time":"2022-11-11T09:03:44Z","timestamp":1668157424000},"page":"43","source":"Crossref","is-referenced-by-count":2,"title":["Differences between two sequential uncemented stem sizes in total hip arthroplasty: A comparative biomechanical study and potential clinical implications"],"prefix":"10.1051","volume":"8","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6900-3213","authenticated-orcid":false,"given":"Katherine","family":"Wang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eustathios","family":"Kenanidis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Khurram","family":"Suleman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mark","family":"Miodownik","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mahsa","family":"Avadi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Horne","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jonathan","family":"Thompson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eleftherios","family":"Tsiridis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mehran","family":"Moazen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"250","published-online":{"date-parts":[[2022,11,11]]},"reference":[{"key":"R1","doi-asserted-by":"crossref","first-page":"747","DOI":"10.1302\/0301-620X.95B6.31378","volume":"95\u2013B","author":"Jameson","year":"2013","journal-title":"Bone Joint J"},{"key":"R2","doi-asserted-by":"crossref","first-page":"1074","DOI":"10.1016\/j.arth.2019.10.060","volume":"35","author":"Hoskins","year":"2020","journal-title":"J Arthroplasty"},{"key":"R3","doi-asserted-by":"crossref","unstructured":"Kenanidis E, Stamatopoulos TH, Kynigopoulos G, Gamie Z, Tsiridis E, Desy NM, Sierra RJ, Purcell RL, Engh CA, Ngu AWT, Punjabi V, Haddad FS (2018) Implant fixation, in Adult Hip \u2013 Master Case Ser. Tech.. Tsiridis E, Editor. Springer International Publishing: Cham. p. 65\u201386.","DOI":"10.1007\/978-3-319-64177-5_3"},{"key":"R4","doi-asserted-by":"crossref","unstructured":"Cross MJ, Roger GJ, Spycher J (2014) 7 \u2013 Cementless fixation techniques and challenges in joint replacement, in Joint Replacement Technology. Revell PA, Editor. Woodhead Publishing. p. 186\u2013211. [Note: This chapter is an updated version of Chapter 9 from the first edition of Joint replacement technology edited by P. A. Revell and published by Woodhead Publishing 2008].","DOI":"10.1533\/9780857098474.2.186"},{"key":"R5","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/j.artd.2019.11.009","volume":"6","author":"Magill","year":"2020","journal-title":"Arthroplast Today"},{"key":"R6","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1016\/S0021-9290(01)00040-9","volume":"34","author":"Bergmann","year":"2001","journal-title":"J Biomech"},{"key":"R7","doi-asserted-by":"crossref","first-page":"1849","DOI":"10.1016\/j.arth.2016.02.013","volume":"31","author":"Moazen","year":"2016","journal-title":"J Arthroplasty"},{"key":"R8","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1016\/j.clinbiomech.2018.12.001","volume":"61","author":"Wang","year":"2019","journal-title":"Clin Biomech"},{"key":"R9","doi-asserted-by":"crossref","first-page":"1019","DOI":"10.2106\/00004623-199307000-00008","volume":"75","author":"McKellop","year":"1993","journal-title":"J Bone Joint Surg Am"},{"key":"R10","doi-asserted-by":"crossref","first-page":"1035","DOI":"10.1016\/j.injury.2014.02.038","volume":"45","author":"Hoffmann","year":"2014","journal-title":"Injury"},{"key":"R11","doi-asserted-by":"crossref","first-page":"751","DOI":"10.3390\/ma11050751","volume":"11","author":"Acciaioli","year":"2018","journal-title":"Materials (Basel, Switzerland)"},{"key":"R12","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1051\/sicotj\/2021064","volume":"8","author":"Wang","year":"2022","journal-title":"SICOT-J"},{"key":"R13","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1016\/S0883-5403(06)80103-8","volume":"8","author":"Rod Davey","year":"1993","journal-title":"J Arthroplasty"},{"key":"R14","doi-asserted-by":"crossref","first-page":"713","DOI":"10.1302\/0301-620X.96B6.34040","volume":"96 B","author":"Duncan","year":"2014","journal-title":"Bone Jt J"},{"key":"R15","doi-asserted-by":"crossref","first-page":"1576","DOI":"10.1302\/0301-620X.90B12.20681","volume":"90","author":"Rayan","year":"2008","journal-title":"J Bone Joint Surg Br"},{"key":"R16","doi-asserted-by":"crossref","first-page":"495","DOI":"10.1016\/j.arth.2013.08.010","volume":"29","author":"Moazen","year":"2014","journal-title":"J Arthroplasty"},{"key":"R17","doi-asserted-by":"crossref","first-page":"146","DOI":"10.5371\/hp.2015.27.3.146","volume":"27","author":"Kim","year":"2015","journal-title":"Hip Pelvis"},{"key":"R18","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1177\/2151458512462870","volume":"3","author":"Marsland","year":"2012","journal-title":"Geriatr Orthop Surg Rehabil"},{"key":"R19","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1177\/112070000901900201","volume":"19","author":"Tsiridis","year":"2009","journal-title":"Hip Int"},{"key":"R20","doi-asserted-by":"crossref","first-page":"325","DOI":"10.5301\/hip.2011.8409","volume":"21","author":"Faisal","year":"2011","journal-title":"Hip Int"},{"key":"R21","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1016\/j.arth.2008.02.002","volume":"24","author":"Engh","year":"2009","journal-title":"J Arthroplasty"},{"key":"R22","unstructured":"Buckwalter JA, Einhorn TA, Simon SR, A.A. of O. Surgeons (2000) Orthopaedic basic science: biology and biomechanics of the musculoskeletal system, 2nd edn. American Academy of Orthopaedic Surgeons: Rosemont, IL."},{"key":"R23","doi-asserted-by":"crossref","first-page":"386","DOI":"10.1080\/17453670610046307","volume":"77","author":"Sk\u00f6ldenberg","year":"2006","journal-title":"Acta Orthop"},{"key":"R24","doi-asserted-by":"crossref","unstructured":"Al-Dirini RMA, O\u2019Rourke D, Huff D, Martelli S, Taylor M (2018) Biomechanical robustness of a contemporary cementless stem to surgical variation in stem size and position. J Biomech Eng, 140. doi: 10.1115\/1.4039824.","DOI":"10.1115\/1.4039824"},{"key":"R25","doi-asserted-by":"crossref","first-page":"8","DOI":"10.4081\/or.2013.e8","volume":"5","author":"Abdulkarim","year":"2013","journal-title":"Orthop Rev (Pavia)"}],"container-title":["SICOT-J"],"original-title":[],"link":[{"URL":"https:\/\/www.sicot-j.org\/10.1051\/sicotj\/2022043\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,11,11]],"date-time":"2022-11-11T09:04:02Z","timestamp":1668157442000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.sicot-j.org\/10.1051\/sicotj\/2022043"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022]]},"references-count":25,"alternative-id":["sicotj220051"],"URL":"https:\/\/doi.org\/10.1051\/sicotj\/2022043","relation":{},"ISSN":["2426-8887"],"issn-type":[{"type":"electronic","value":"2426-8887"}],"subject":[],"published":{"date-parts":[[2022]]}}}