{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2022,4,3]],"date-time":"2022-04-03T14:18:47Z","timestamp":1648995527471},"reference-count":27,"publisher":"EDP Sciences","license":[{"start":{"date-parts":[[2021,3,29]],"date-time":"2021-03-29T00:00:00Z","timestamp":1616976000000},"content-version":"vor","delay-in-days":87,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["E3S Web Conf."],"published-print":{"date-parts":[[2021]]},"abstract":"<jats:p>The present work focuses on the production of thermal energy in University building greenhouses in cold climate conditions. The building model uses a system of energy and mass balance integral equations, which are solved by the Runge\u2013Kutta\u2013Felberg method with error control. This numerical study is about the thermal behaviour of a university building with complex topology, in winter and transient conditions. The thermal comfort of the occupants, using the Predicted Mean Vote index, and the indoor air quality, using the carbon dioxide concentration, are evaluated. This building has 319 compartments distributed by four floors and it is equipped with one internal greenhouse in the third floor. This greenhouse is located on the south facing facade and the heated air in this space will be transported to compartments located on the north facing fa\u00e7ade. The spaces subject to the influence of the heated air coming from the greenhouse improve the level of thermal comfort of its occupants. The level of indoor air quality in occupied spaces is acceptable according to international standards.<\/jats:p>","DOI":"10.1051\/e3sconf\/202124603004","type":"journal-article","created":{"date-parts":[[2021,3,30]],"date-time":"2021-03-30T11:53:23Z","timestamp":1617105203000},"page":"03004","source":"Crossref","is-referenced-by-count":0,"title":["Production of thermal energy in University building greenhouses in cold climate conditions"],"prefix":"10.1051","volume":"246","author":[{"given":"Eus\u00e9bio","family":"Concei\u00e7\u00e3o","sequence":"first","affiliation":[]},{"given":"Jo\u00e3o","family":"Gomes","sequence":"additional","affiliation":[]},{"given":"Maria Manuela","family":"L\u00facio","sequence":"additional","affiliation":[]},{"given":"Hazim","family":"Awbi","sequence":"additional","affiliation":[]}],"member":"250","published-online":{"date-parts":[[2021,3,29]]},"reference":[{"key":"R1","doi-asserted-by":"crossref","first-page":"03010","DOI":"10.1051\/e3sconf\/202017203010","volume":"172","author":"Guasco","year":"2020","journal-title":"E3S Web of Conferences"},{"key":"R2","doi-asserted-by":"crossref","first-page":"4816","DOI":"10.3390\/su11184816","volume":"11","author":"Fernandez-Antolin","year":"2019","journal-title":"Sustainability"},{"key":"R3","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1016\/j.enbuild.2016.12.067","volume":"138","author":"Chiesa","year":"2017","journal-title":"Energy Build."},{"key":"R4","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/j.enbuild.2015.02.049","volume":"98","author":"Ignjatovic","year":"2015","journal-title":"Energy Build."},{"key":"R5","doi-asserted-by":"crossref","first-page":"100015","DOI":"10.1016\/j.dibe.2020.100015","volume":"3","author":"Puertolas","year":"2020","journal-title":"Developments in the Built Environment"},{"key":"R6","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1016\/j.enbuild.2017.04.034","volume":"152","author":"Ulpiani","year":"2017","journal-title":"Energy Build."},{"key":"R7","doi-asserted-by":"crossref","first-page":"766","DOI":"10.3390\/atmos10120766","volume":"10","author":"Concei\u00e7\u00e3o","year":"2019","journal-title":"Atmosphere"},{"key":"R8","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1007\/s12273-010-0010-7","volume":"3","author":"Concei\u00e7\u00e3o","year":"2010","journal-title":"Build. Simul."},{"issue":"1","key":"R9","first-page":"53","volume":"11","author":"Concei\u00e7\u00e3o","year":"2012","journal-title":"Int. J. Vent."},{"key":"R10","first-page":"644","volume":"4","author":"Concei\u00e7\u00e3o","year":"2008","journal-title":"WSEAS Trans. Environ. Dev,"},{"key":"R11","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1177\/1420326X08099550","volume":"18","author":"Concei\u00e7\u00e3o","year":"2009","journal-title":"Indoor Built Environ."},{"key":"R12","unstructured":"Fanger P., Thermal comfort: analysis and applications in environmental engineering. Danish Technical Press, Copenhagen, Denmark, 1970."},{"key":"R13","unstructured":"ANSI\/ASHRAE Standard 55, Thermal Environmental Conditions for Human Occupancy. American Society of Heating, Refrigerating and Air-Conditioning Engineers: Atlanta, GA, USA, 2017."},{"key":"R14","unstructured":"ISO 7730, Ergonomics of the thermal environments \u2013 Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD Indices and Local Thermal Comfort Criteria. International Standard Organization: Geneva, Switzerland, 2005."},{"issue":"3","key":"R15","doi-asserted-by":"crossref","first-page":"38","DOI":"10.3390\/buildings6030038","volume":"6","author":"Concei\u00e7\u00e3o","year":"2016","journal-title":"Buildings"},{"key":"R16","doi-asserted-by":"crossref","first-page":"871","DOI":"10.1016\/j.buildenv.2008.06.015","volume":"44","author":"Concei\u00e7\u00e3o","year":"2009","journal-title":"Build. Environ."},{"issue":"3","key":"R17","first-page":"287","volume":"9","author":"Concei\u00e7\u00e3o","year":"2010","journal-title":"Int. J. Vent."},{"key":"R18","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1016\/j.ifacol.2018.06.230","volume":"51\u201310","author":"Concei\u00e7\u00e3o","year":"2018","journal-title":"IFAC PapersOnLine"},{"key":"R19","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1016\/j.buildenv.2018.01.042","volume":"133","author":"Asif","year":"2018","journal-title":"Build. Environ."},{"key":"R20","doi-asserted-by":"crossref","first-page":"868","DOI":"10.1111\/ina.12383","volume":"27","author":"Persily","year":"2017","journal-title":"Indoor Air,"},{"key":"R21","unstructured":"ANSI\/ASHRAE Standard 62\u20131, Ventilation for Acceptable Indoor Air Quality. American Society of Heating, Refrigerating and Air-Conditioning Engineers: Atlanta, GA, USA, 2016."},{"issue":"3","key":"R22","first-page":"267","volume":"7","author":"Concei\u00e7\u00e3o","year":"2008","journal-title":"Int. J. Vent."},{"issue":"4","key":"R23","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1080\/10789669.2010.10390912","volume":"16","author":"Concei\u00e7\u00e3o","year":"2010","journal-title":"HVAC&R Res."},{"key":"R24","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1007\/s12273-012-0093-4","volume":"6","author":"Concei\u00e7\u00e3o","year":"2013","journal-title":"Build. Simul."},{"key":"R25","unstructured":"Concei\u00e7\u00e3o E., Silva A., and L\u00facio M., \u201cNumerical study of thermal response of school buildings in winter conditions,\u201d In Proceedings of the 9th Conference on Air Distribution in Rooms (Roomvent 2004), Coimbra, Portugal, September 5\u20138, 2004."},{"key":"R26","unstructured":"Concei\u00e7\u00e3o E. and L\u00facio M., \u201cNumerical study of thermal response of school buildings in summer conditions,\u201d In Proceedings of the 8th International Conference and Exhibition on Healthy Buildings (HB 2006), Lisbon, Portugal, June 4\u20138, 2006."},{"key":"R27","unstructured":"Portaria 353-A, Requisitos de ventila\u00e7\u00e3o e qualidade do ar interior. Di\u00e1rio da Rep\u00fablica n.\u00ba 235\/2013, 1\u00ba Suplemento, S\u00e9rie I de 2013\u201312\u201304, 2013. (in Portuguese)"}],"container-title":["E3S Web of Conferences"],"original-title":[],"link":[{"URL":"https:\/\/www.e3s-conferences.org\/10.1051\/e3sconf\/202124603004\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,3,30]],"date-time":"2021-03-30T19:02:02Z","timestamp":1617130922000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.e3s-conferences.org\/10.1051\/e3sconf\/202124603004"}},"subtitle":[],"editor":[{"given":"J.","family":"Kurnitski","sequence":"first","affiliation":[]},{"given":"M.","family":"Thalfeldt","sequence":"additional","affiliation":[]}],"short-title":[],"issued":{"date-parts":[[2021]]},"references-count":27,"alternative-id":["e3sconf_hvac2021_03004"],"URL":"https:\/\/doi.org\/10.1051\/e3sconf\/202124603004","relation":{},"ISSN":["2267-1242"],"issn-type":[{"value":"2267-1242","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021]]}}}