{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,3]],"date-time":"2026-04-03T22:05:17Z","timestamp":1775253917168,"version":"3.50.1"},"reference-count":14,"publisher":"EDP Sciences","license":[{"start":{"date-parts":[[2021,12,3]],"date-time":"2021-12-03T00:00:00Z","timestamp":1638489600000},"content-version":"vor","delay-in-days":336,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["MATEC Web Conf."],"published-print":{"date-parts":[[2021]]},"abstract":"<jats:p>Laminated glass panels with point fixing restraints are widely used in buildings. Although significant progress has been reached within its production and installation, a lack of standardization, and particularly, their actual load-bearing capacity and performance under seismic events is not well addressed, and is largely affected by the connection detailing and typology. The present research study explores the seismic performance of single laminated glass panels with various point fixing solutions. The characterization involves experimental set ups and numerical models.<\/jats:p>","DOI":"10.1051\/matecconf\/202135200013","type":"journal-article","created":{"date-parts":[[2021,12,3]],"date-time":"2021-12-03T09:48:00Z","timestamp":1638524880000},"page":"00013","source":"Crossref","is-referenced-by-count":2,"title":["Seismic Behaviour of Bolted and Bonded Point Fixed Laminated Glass Panels"],"prefix":"10.1051","volume":"352","author":[{"given":"Eliana","family":"Inca","sequence":"first","affiliation":[]},{"given":"Chiara","family":"Bedon","sequence":"additional","affiliation":[]},{"given":"Sandra","family":"Jord\u00e3o","sequence":"additional","affiliation":[]},{"given":"Carlos","family":"Rebelo","sequence":"additional","affiliation":[]}],"member":"250","published-online":{"date-parts":[[2021,12,3]]},"reference":[{"key":"R1","unstructured":"Vitkala J., https:\/\/www.gii.fl\/@Bin\/199723\/trendsgpd2017textenglvr4.pdf, Glass Performance Days (2017)"},{"key":"R2","doi-asserted-by":"crossref","unstructured":"Bedon C., Santarsiero M., Advanced Engineering Materials, 20, 5: 1700815 (2018), doi: 10.1002\/adem.201700815","DOI":"10.1002\/adem.201700815"},{"key":"R3","doi-asserted-by":"crossref","unstructured":"Bedon C., Zhang X., Santos F., Honfi D., Kozlowski M., Arrigoni M., Figuli L., Lange D., Construction and Building Materials, 63, 28: 921\u2013937 (2018), doi: 10.1016\/j.conbuildmat.2017.12.153","DOI":"10.1016\/j.conbuildmat.2017.12.153"},{"key":"R4","doi-asserted-by":"crossref","unstructured":"Bedon C., Amadio C., Noe S., Safety, 5, 4: 80 (2019), doi: 10.3390\/safety5040080","DOI":"10.3390\/safety5040080"},{"key":"R5","doi-asserted-by":"crossref","unstructured":"Jennings P.C., Earthquake Spectra, 3, 1 (1997), doi: 10.1193\/1.1585930","DOI":"10.1193\/1.1585930"},{"key":"R6","unstructured":"Evans D., Ramirez F.J.L., Reducing Earthquake Hazards: Lessons Learned from the 1985 Mexico Earthquake, pp. 234\u2013236, Publ by Earthquake Engineering Research Inst, (1989)"},{"key":"R7","doi-asserted-by":"crossref","unstructured":"Roeslin S.M.Q., Ma Q.T.M., Garc\u00eda H.J., Frontiers in Built Environment, 4: 1\u201318 (2018), doi: 10.3389\/fbuil.2018.00072","DOI":"10.3389\/fbuil.2018.00072"},{"key":"R8","doi-asserted-by":"crossref","unstructured":"Baird A., Palermo A., Pampanin S., Bulletin of the New Zealand Society for earthquake engineering, 44, 4: 368\u2013376 (2011), doi: 10.5459\/bnzsee.44.4.368-376","DOI":"10.5459\/bnzsee.44.4.368-376"},{"key":"R9","doi-asserted-by":"crossref","unstructured":"Baird A., Ferner H., Bulletin of the New Zealand Society for Earthquake Engineering, 50, 2: 187\u2013193 (2017), doi: 10.5459\/bnzsee.50.2.187-193","DOI":"10.5459\/bnzsee.50.2.187-193"},{"key":"R10","doi-asserted-by":"crossref","unstructured":"Hosseini M., Earthquake Spectra, 21, 1: 439\u2013453 (2005), doi: 10.1193\/1.2098829","DOI":"10.1193\/1.2098829"},{"key":"R11","doi-asserted-by":"crossref","unstructured":"Behr R.A., Architectural glass to resist seismic and extreme climatic events, Elsevier, 272 pages, (2009)","DOI":"10.1533\/9781845696856"},{"key":"R12","doi-asserted-by":"crossref","unstructured":"Perrone D., Calvi P.M., Nascimbene R., Fischer E.C., Magliulo G., Bulletin of Earthquake Engineering, 17, 10: 5655\u20135677 (2019), doi: 10.1007\/s10518-018-0361-5","DOI":"10.1007\/s10518-018-0361-5"},{"key":"R13","doi-asserted-by":"crossref","unstructured":"Sucuoglu H., Vallabhan C.G., Engineering structures, 19, 8: 685\u2013694 (1997)","DOI":"10.1016\/S0141-0296(96)00130-7"},{"key":"R14","unstructured":"AAMA 501.6:2018, Recommended Dynamic Test Method for Determining the Seismic Drift Causing Glass Fallout from Window Wall, Curtain Wall and Storefront Systems"}],"container-title":["MATEC Web of Conferences"],"original-title":[],"link":[{"URL":"https:\/\/www.matec-conferences.org\/10.1051\/matecconf\/202135200013\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,12,3]],"date-time":"2021-12-03T09:49:36Z","timestamp":1638524976000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.matec-conferences.org\/10.1051\/matecconf\/202135200013"}},"subtitle":[],"editor":[{"given":"D.","family":"Pap\u00e1n","sequence":"first","affiliation":[]},{"given":"Z.","family":"Zvakov\u00e1","sequence":"additional","affiliation":[]},{"given":"M.","family":"\u0160\u010dotka","sequence":"additional","affiliation":[]}],"short-title":[],"issued":{"date-parts":[[2021]]},"references-count":14,"alternative-id":["matecconf_edes2021_00013"],"URL":"https:\/\/doi.org\/10.1051\/matecconf\/202135200013","relation":{},"ISSN":["2261-236X"],"issn-type":[{"value":"2261-236X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021]]}}}