{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,9]],"date-time":"2026-01-09T20:18:16Z","timestamp":1767989896866,"version":"3.49.0"},"reference-count":36,"publisher":"EDP Sciences","license":[{"start":{"date-parts":[[2021,9,27]],"date-time":"2021-09-27T00:00:00Z","timestamp":1632700800000},"content-version":"vor","delay-in-days":269,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"funda\u00e7\u00e3o para a ci\u00eancia e a tecnologia","award":["PTDC\/ECI EGC\/29083\/2017"],"award-info":[{"award-number":["PTDC\/ECI EGC\/29083\/2017"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Renew. Energy Environ. Sustain."],"accepted":{"date-parts":[[2021,9,7]]},"published-print":{"date-parts":[[2021]]},"abstract":"<jats:p>Building foundation piles can be used as heat exchangers in ground-source heat pump (GSHP) systems to provide highly efficient renewable heating and cooling (H&amp;C). Unbalanced H&amp;C loads lead to heat build-up in the ground, decreasing the system's overall performance. In this study, the introduction of natural ventilation (NV) has been examined to decrease cooling load imbalance in cooling-dominated buildings to improve system efficiency. Building energy simulations estimated the H&amp;C loads for an office building in three Portuguese cities: Lisbon, Porto and Faro, yielding heating loads of 0.2\u20133.6 MWh\/year and cooling loads of 260\u2013450 MWh\/year. Four renewable H&amp;C technology scenarios were used to assess energy performance: (1) an air-source heat pump (ASHP) system; (2) a GSHP system utilizing energy piles; (3) hybrid ASHP-NV and (4) hybrid GSHP-NV. Over 50 years of operation, in Scenario (1) COP values of 2.45\u20132.55 (heating) and 3.62\u20134.15 (cooling) were obtained. In (2), COP values increased to 4.15\u20134.34 (heating) but fell to 3.36\u20133.79 (cooling), which increased annual final energy needs by 7\u20138%. Unbalanced cooling loads increased the ground temperature by 21\u201324\u2009\u00b0C, which is unlikely to be acceptable. Compared to (1), introducing NV reduced cooling loads by 65\u201390% in Scenarios (3) and (4), with the final energy needs decreasing by 59\u201380% and 62\u201388%, respectively. A further benefit of the GSHP-NV hybrid is that the ground temperature increase was limited to 8\u201112\u2009\u00b0C. For cooling, the COP in (3) decreased compared to (1) (3.14\u20133.69), while in (4), COP improved to 3.45\u20136.10. This study concludes that hybrid GSHP-NV systems should be considered in some cooling-dominated scenarios.<\/jats:p>","DOI":"10.1051\/rees\/2021032","type":"journal-article","created":{"date-parts":[[2021,9,27]],"date-time":"2021-09-27T08:40:18Z","timestamp":1632732018000},"page":"33","source":"Crossref","is-referenced-by-count":3,"title":["Hybridization of Heat Pump Systems With Natural Ventilation To Improve Energy Efficiency in Cooling Dominated Buildings"],"prefix":"10.1051","volume":"6","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3087-3123","authenticated-orcid":false,"given":"Nuno R.","family":"Martins","sequence":"first","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1203-4710","authenticated-orcid":false,"given":"Peter J.","family":"Bourne-Webb","sequence":"additional","affiliation":[]}],"member":"250","published-online":{"date-parts":[[2021,9,27]]},"reference":[{"key":"R1","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1016\/j.atmosenv.2010.09.048","volume":"45","author":"Chen","year":"2011","journal-title":"Atmos. Environ."},{"key":"R2","doi-asserted-by":"crossref","first-page":"1194","DOI":"10.1016\/j.renene.2016.09.061","volume":"101","author":"Chwieduk","year":"2017","journal-title":"Renew. Energy"},{"key":"R3","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1016\/j.enbuild.2013.11.068","volume":"70","author":"Sarbu","year":"2014","journal-title":"Energy Build."},{"key":"R4","doi-asserted-by":"crossref","first-page":"2572","DOI":"10.1016\/j.renene.2018.11.025","volume":"147","author":"Bourne-Webb","year":"2020","journal-title":"Renew. Energy"},{"key":"R5","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1016\/j.energy.2017.01.097","volume":"122","author":"Fadejev","year":"2017","journal-title":"Energy"},{"key":"R6","doi-asserted-by":"crossref","first-page":"2826","DOI":"10.1016\/j.apenergy.2009.04.044","volume":"87","author":"Man","year":"2010","journal-title":"Appl. Energy"},{"key":"R7","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1016\/j.egypro.2011.12.917","volume":"14","author":"Zhang","year":"2012","journal-title":"Energy Proc."},{"key":"R8","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1016\/j.energy.2019.02.061","volume":"173","author":"Liu","year":"2019","journal-title":"Energy"},{"key":"R9","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1016\/j.enbuild.2018.08.005","volume":"177","author":"Beckers","year":"2018","journal-title":"Energy Build."},{"key":"R10","doi-asserted-by":"crossref","first-page":"711","DOI":"10.1016\/j.apenergy.2016.12.103","volume":"189","author":"Martins","year":"2017","journal-title":"Appl. Energy"},{"key":"R11","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1016\/j.buildenv.2017.01.030","volume":"115","author":"Martins","year":"2017","journal-title":"Build. Environ."},{"key":"R12","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1016\/j.renene.2017.10.089","volume":"117","author":"Martins","year":"2018","journal-title":"Renew. Energy"},{"key":"R13","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1016\/S0378-7788(00)00114-6","volume":"33","author":"Crawley","year":"2001","journal-title":"Energy Build."},{"key":"R14","doi-asserted-by":"crossref","first-page":"109556","DOI":"10.1016\/j.enbuild.2019.109556","volume":"206","author":"Bravo Dias","year":"2020","journal-title":"Energy Build."},{"key":"R15","unstructured":"Aguiar R., INETI Synthetic Weather Data for Portugal. Instituto Nacional de Engenharia, Tecnologia e Inova\u00e7\u00e3o (INETI), 2005"},{"key":"R16","unstructured":"ASHRAE, International Weather for Energy Calculations (IWEC Weather Files) Users Manual and CD-ROM, in American Society of Heating, Refrigerating, and Air Conditioning Engineers, Inc., Atlanta, GA, United States, 2001"},{"key":"R17","unstructured":"Weather Data | EnergyPlus, https:\/\/energyplus.net\/weather [last accessed August 2021]"},{"key":"R18","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1127\/0941-2948\/2006\/0130","volume":"15","author":"Kottek","year":"2006","journal-title":"Meteorologische Zeitschrift"},{"key":"R19","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1127\/metz\/2016\/0816","volume":"26","author":"Rubel","year":"2017","journal-title":"Meteorologische Zeitschrift"},{"key":"R20","doi-asserted-by":"crossref","unstructured":"Deru M., Field K., Studer D., Benne K., Griffith B., Torcellini P., Liu B., Halverson M., Winiarski D., Rosenberg M., Yazdanian M., Huang J., Crawley D., U. S. Department of Energy Commercial Reference Building Models of the National Building Stock, National Renewable Energy Laboratory, NREL\/TP-5500-46861 (2011)","DOI":"10.2172\/1009264"},{"key":"R21","unstructured":"Portaria n. \u00b0 349\u2011D\/2013 (2013)"},{"key":"R22","unstructured":"California Building Standards Commission, Title 24-Building Standards Code, Part 4-California Mechanical Code, California Code of Regulations (2013)"},{"key":"R23","unstructured":"International Organization for Standardization, ISO 7730:2005 Ergonomics of the thermal environment \u2212 Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria (2005)"},{"key":"R24","doi-asserted-by":"crossref","unstructured":"Johnston J., Counsell J., Strachan P.A., Trends in Office Internal Gains and the Impact on Space Heating and Cooling. CIBSE Technical Symposium, DeMontfort University, Leicester, UK (2011)","DOI":"10.3943\/2011.0021"},{"key":"R25","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1016\/j.enbuild.2014.07.033","volume":"82","author":"Zhao","year":"2014","journal-title":"Energy Build."},{"key":"R26","unstructured":"ASHRAE, ASHRAE Handbook \u2212 Fundamentals. American Society of Heating, Refrigerating, and Air Conditioning Engineers, Inc., Atlanta, GA, United States (2013)"},{"key":"R27","unstructured":"Malato Lerer M., Carrilho da Gra\u00e7a G., Linden P.F., Building energy demand response simulation for an office tower in New York, in Proceedings of BS2013: 13th Conference of International Building Performance Simulation Association, Chamb\u00e9ry, France (2013), p. 2511\u20132518"},{"key":"R28","first-page":"177","volume":"50","author":"Carrilho da Gra\u00e7a","year":"2012","journal-title":"Thermal and airflow simulation of a naturally ventilated shopping mall, Energy Build."},{"key":"R29","doi-asserted-by":"crossref","first-page":"1937","DOI":"10.1016\/j.enbuild.2011.03.039","volume":"43","author":"Ertesv\u00e5g","year":"2011","journal-title":"Energy Build."},{"key":"R30","unstructured":"Pahud D., PILESIM2\u2013simulation tool for heating\/cooling systems with energy piles or multiple borehole heat exchangers \u2212 user manual, in ISAAC-DAC-SUPSI, Lugano, Switzerland (2007)"},{"key":"R31","unstructured":"Hellstr\u00f6m G., Duct Ground Heat Storage Model, Manual for Computer Code, Department of Mathematical Physics, University of Lund, Sweden (1989)"},{"key":"R32","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1016\/j.energy.2012.12.043","volume":"51","author":"Fossa","year":"2013","journal-title":"Energy"},{"key":"R33","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1016\/j.enbuild.2010.08.017","volume":"43","author":"Corberan","year":"2011","journal-title":"Energy Build."},{"key":"R34","doi-asserted-by":"crossref","first-page":"588","DOI":"10.1016\/j.buildenv.2006.06.031","volume":"43","author":"Herkel","year":"2008","journal-title":"Build. Environ."},{"key":"R35","first-page":"3","volume":"7","author":"Warren","year":"1986","journal-title":"Air Infiltration Rev."},{"key":"R36","doi-asserted-by":"crossref","first-page":"914","DOI":"10.1016\/j.enpol.2013.04.040","volume":"59","author":"H\u00e4hnlein","year":"2013","journal-title":"Energy Policy"}],"container-title":["Renewable Energy and Environmental Sustainability"],"original-title":[],"link":[{"URL":"https:\/\/www.rees-journal.org\/10.1051\/rees\/2021032\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,9,27]],"date-time":"2021-09-27T08:41:14Z","timestamp":1632732074000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.rees-journal.org\/10.1051\/rees\/2021032"}},"subtitle":[],"editor":[{"given":"Hussein","family":"Kazem","sequence":"first","affiliation":[]},{"given":"Marta","family":"Szabo","sequence":"additional","affiliation":[]},{"given":"Abdul Salam K.","family":"Darwish","sequence":"additional","affiliation":[]}],"short-title":[],"issued":{"date-parts":[[2021]]},"references-count":36,"alternative-id":["rees210023"],"URL":"https:\/\/doi.org\/10.1051\/rees\/2021032","relation":{},"ISSN":["2493-9439"],"issn-type":[{"value":"2493-9439","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021]]}}}