{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,4]],"date-time":"2025-06-04T20:28:39Z","timestamp":1749068919061},"reference-count":43,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2016,5,1]],"date-time":"2016-05-01T00:00:00Z","timestamp":1462060800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","ackdjournal.org","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Advances in Chronic Kidney Disease"],"published-print":{"date-parts":[[2016,5]]},"DOI":"10.1053\/j.ackd.2016.01.015","type":"journal-article","created":{"date-parts":[[2016,4,29]],"date-time":"2016-04-29T16:22:12Z","timestamp":1461946932000},"page":"141-145","update-policy":"http:\/\/dx.doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":12,"title":["Critical Care Ultrasound: A Review for Practicing Nephrologists"],"prefix":"10.1053","volume":"23","author":[{"given":"Jennifer G.","family":"Wilson","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kristine E.W.","family":"Breyer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1053\/j.ackd.2016.01.015_bib1","unstructured":"ACGME Program Requirements for Graduate Medical Education in Anesthesiology Critical Care Medicine. Available at: https:\/\/www.acgme.org\/acgmeweb\/Portals\/0\/PFAssets\/2013-PR-FAQ-PIF\/142_critical_care_int_med_07132013.pdf; https:\/\/www.acgme.org\/acgmeweb\/Portals\/0\/PFAssets\/ProgramRequirements\/045_critical_care_anes_07012014_1-YR.pdf; https:\/\/www.acgme.org\/acgmeweb\/Portals\/0\/PFAssets\/ProgramRequirements\/442_surgical_critical_care_2016_1-YR.pdf; https:\/\/www.acgme.org\/acgmeweb\/portals\/0\/pfassets\/2013-pr-faq-pif\/323_critical_care_peds_07012013.pdf; Accessed October 30,\u00a02015."},{"key":"10.1053\/j.ackd.2016.01.015_bib2","unstructured":"Surviving Sepsis Campaign Executive Committee. Surviving Sepsis Campaign Bundles. Available at: http:\/\/www.survivingsepsis.org\/SiteCollectionDocuments\/SSC_Bundle.pdf; Accessed October 30,\u00a02015."},{"key":"10.1053\/j.ackd.2016.01.015_bib3","series-title":"Recommendations for Achieving and Maintaining Competence and Credentialing in Critical Care Ultrasound with Focused Cardiac Ultrasound and\u00a0Advanced Critical Care Echocardiography","first-page":"1","year":"2014"},{"issue":"1","key":"10.1053\/j.ackd.2016.01.015_bib4","doi-asserted-by":"crossref","first-page":"188","DOI":"10.1186\/1471-2369-14-188","article-title":"Clinical utility of gray scale renal ultrasound in acute kidney injury","volume":"14","author":"Podoll","year":"2013","journal-title":"BMC Nephrol"},{"issue":"21","key":"10.1053\/j.ackd.2016.01.015_bib5","doi-asserted-by":"crossref","first-page":"1900","DOI":"10.1001\/archinternmed.2010.419","article-title":"Renal ultrasonography in the evaluation of acute kidney injury: developing a risk stratification framework","volume":"170","author":"Licurse","year":"2010","journal-title":"Arch Intern Med"},{"issue":"21","key":"10.1053\/j.ackd.2016.01.015_bib6","doi-asserted-by":"crossref","first-page":"1907","DOI":"10.1001\/archinternmed.2010.411","article-title":"Curbing the use of ultrasonography in the diagnosis of acute kidney injury: penny wise or pound foolish?: comment on \u201cRenal ultrasonography in the evaluation of acute kidney injury\u201d","volume":"170","author":"Liu","year":"2010","journal-title":"Arch Intern Med"},{"key":"10.1053\/j.ackd.2016.01.015_bib7","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1097\/ALN.0b013e31823c9569","article-title":"Practice guidelines for central venous access","volume":"116","year":"2012","journal-title":"Anesthesiology"},{"key":"10.1053\/j.ackd.2016.01.015_bib8","doi-asserted-by":"crossref","first-page":"1764","DOI":"10.1097\/01.CCM.0000171533.92856.E5","article-title":"Randomized, controlled clinical trial of point-of-care limited ultrasonography assistance of central venous cannulation: the Third Sonography Outcomes Assessment Program (SOAP-3) Trial","volume":"33","author":"Milling","year":"2005","journal-title":"Crit Care Med"},{"key":"10.1053\/j.ackd.2016.01.015_bib9","series-title":"On making health care safer: a critical analysis of patient safety practices","first-page":"245","article-title":"Ultrasound Guidance of Central Vein Catheterization","author":"Rothschild","year":"2001"},{"key":"10.1053\/j.ackd.2016.01.015_bib10","first-page":"CD006962","article-title":"Ultrasound guidance versus anatomical landmarks for internal jugular vein catheterization","volume":"1","author":"Brass","year":"2015","journal-title":"Cochrane Database Syst Rev"},{"key":"10.1053\/j.ackd.2016.01.015_bib11","first-page":"CD011447","article-title":"Ultrasound guidance versus anatomical landmarks for subclavian or femoral vein catheterization","volume":"1","author":"Brass","year":"2015","journal-title":"Cochrane Database Syst Rev"},{"key":"10.1053\/j.ackd.2016.01.015_bib12","doi-asserted-by":"crossref","first-page":"1055","DOI":"10.1111\/j.1553-2712.2010.00886.x","article-title":"Risk factors for acute adverse events during ultrasound-guided central venous cannulation in the emergency department","volume":"17","author":"Theodoro","year":"2010","journal-title":"Acad Emerg Med"},{"key":"10.1053\/j.ackd.2016.01.015_bib13","doi-asserted-by":"crossref","first-page":"1239","DOI":"10.7863\/jum.2009.28.9.1239","article-title":"Video analysis of accidental arterial cannulation with dynamic ultrasound guidance for central venous access","volume":"28","author":"Blaivas","year":"2009","journal-title":"J Ultrasound Med"},{"issue":"11","key":"10.1053\/j.ackd.2016.01.015_bib14","doi-asserted-by":"crossref","first-page":"2479","DOI":"10.1097\/CCM.0000000000001216","article-title":"Guidelines for the appropriate use of bedside general and cardiac ultrasonography in the evaluation of critically ill patients\u2014part I","volume":"43","author":"Frankel","year":"2015","journal-title":"Crit Care Med"},{"issue":"8","key":"10.1053\/j.ackd.2016.01.015_bib15","doi-asserted-by":"crossref","first-page":"2345","DOI":"10.1097\/CCM.0b013e3181a067d4","article-title":"An unseen danger: frequency of posterior vessel wall penetration by needles during attempts to place internal jugular vein central catheters using ultrasound guidance","volume":"37","author":"Blaivas","year":"2009","journal-title":"Crit Care Med"},{"key":"10.1053\/j.ackd.2016.01.015_bib16","first-page":"21","article-title":"Long versus short-axis ultrasound-guided approach to ICU cannulation: a prospective, randomized controlled trial","volume":"13","author":"Chitoodan","year":"2001","journal-title":"Med Ultrason"},{"key":"10.1053\/j.ackd.2016.01.015_bib17","doi-asserted-by":"crossref","first-page":"1194","DOI":"10.1016\/j.ajem.2010.07.015","article-title":"Short- vs long-axis approach to ultrasound-guided peripheral intravenous access: a prospective randomized study","volume":"29","author":"Mahler","year":"2011","journal-title":"Am J Emerg Med"},{"key":"10.1053\/j.ackd.2016.01.015_bib18","doi-asserted-by":"crossref","first-page":"1307","DOI":"10.1111\/j.1553-2712.2003.tb00002.x","article-title":"Short-axis versus long-axis approaches for teaching ultrasound-guided vascular access on a new inanimate model","volume":"10","author":"Blaivas","year":"2003","journal-title":"Acad Emerg Med"},{"key":"10.1053\/j.ackd.2016.01.015_bib19","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1016\/j.ajem.2008.11.022","article-title":"Needle tip visualization during ultrasound-guided vascular access: short-axis vs long-axis approach","volume":"28","author":"Stone","year":"2010","journal-title":"Am J Emerg Med"},{"issue":"1","key":"10.1053\/j.ackd.2016.01.015_bib20","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1016\/j.ajem.2008.09.019","article-title":"Ultrasound detection of guidewire position during central venous catheterization","volume":"28","author":"Stone","year":"2010","journal-title":"Am J Emerg Med"},{"key":"10.1053\/j.ackd.2016.01.015_bib21","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1186\/1757-7241-18-39","article-title":"Ultrasound confirmation of guidewire position may eliminate accidental arterial dilatation during central venous cannulation","volume":"18","author":"Gillman","year":"2010","journal-title":"Scand J Trauma Resusc Emerg Med"},{"key":"10.1053\/j.ackd.2016.01.015_bib22","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jss.2010.04.020","article-title":"Bedside ultrasound can safely eliminate the need for chest radiographs after central venous catheter placement: CVC sono in the surgical ICU (SICU)","volume":"163","author":"Matsushima","year":"2010","journal-title":"J Surg Res"},{"key":"10.1053\/j.ackd.2016.01.015_bib23","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1097\/CCM.0b013e3181c0328f","article-title":"Ultrasound localization of central vein catheter and detection of postprocedural pneumothorax: an alternative to chest radiography","volume":"38","author":"Vezzani","year":"2010","journal-title":"Crit Care Med"},{"key":"10.1053\/j.ackd.2016.01.015_bib24","doi-asserted-by":"crossref","first-page":"410","DOI":"10.1097\/01.shk.0000142186.95718.82","article-title":"Severity of emergency department hypotension predicts adverse hospital outcome","volume":"22","author":"Jones","year":"2004","journal-title":"Shock"},{"key":"10.1053\/j.ackd.2016.01.015_bib25","doi-asserted-by":"crossref","first-page":"2562","DOI":"10.1097\/CCM.0000000000001285","article-title":"Bedside ultrasound reduces diagnostic uncertainty and guides resuscitation in patients with undifferentiated hypotension","volume":"43","author":"Shokoohi","year":"2015","journal-title":"Crit Care Med"},{"key":"10.1053\/j.ackd.2016.01.015_bib26","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1016\/j.annemergmed.2012.01.006","article-title":"Effect of bedside ultrasonography on the certainty of physician clinical decision making for septic patients in the emergency department","volume":"60","author":"Haydar","year":"2012","journal-title":"Ann Emerg Med"},{"issue":"4","key":"10.1053\/j.ackd.2016.01.015_bib27","doi-asserted-by":"crossref","first-page":"801","DOI":"10.1097\/ALN.0b013e318264c621","article-title":"Deep impact of ultrasound in the intensive care unit: the \u201cICU-sound\u201d protocol","volume":"117","author":"Manno","year":"2012","journal-title":"Anesthesiology"},{"key":"10.1053\/j.ackd.2016.01.015_bib28","doi-asserted-by":"crossref","first-page":"1290","DOI":"10.1007\/s00134-013-2919-7","article-title":"Point-of-care multiorgan ultrasonography for the evaluation of undifferentiated hypotension in the emergency department","volume":"39","author":"Volpicelli","year":"2013","journal-title":"Intensive Care Med"},{"key":"10.1053\/j.ackd.2016.01.015_bib29","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1016\/j.jcrc.2014.04.008","article-title":"Limited echocardiography-guided therapy in subacute shock is associated with change in management and improved outcomes","volume":"29","author":"Kanji","year":"2014","journal-title":"J Crit Care"},{"key":"10.1053\/j.ackd.2016.01.015_bib30","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1016\/j.echo.2010.05.010","volume":"23","author":"Rudski","year":"2010","journal-title":"J Am Soc Echocardiogr"},{"issue":"1","key":"10.1053\/j.ackd.2016.01.015_bib31","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1097\/01.CCM.0000249851.94101.4F","article-title":"Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge","volume":"35","author":"Osman","year":"2007","journal-title":"Crit Care Med"},{"issue":"7","key":"10.1053\/j.ackd.2016.01.015_bib32","doi-asserted-by":"crossref","first-page":"1774","DOI":"10.1097\/CCM.0b013e31828a25fd","article-title":"Does the central venous pressure predict fluid responsiveness? An updated meta-analysis and a plea for some common sense","volume":"41","author":"Marik","year":"2013","journal-title":"Crit Care Med"},{"issue":"9","key":"10.1053\/j.ackd.2016.01.015_bib33","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s00134-004-2259-8","article-title":"Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients","volume":"30","author":"Barbier","year":"2004","journal-title":"Intensive Care Med"},{"issue":"9","key":"10.1053\/j.ackd.2016.01.015_bib34","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s00134-004-2233-5","article-title":"The respiratory variation in inferior vena cava diameter as a guide to fluid therapy","volume":"30","author":"Feissel","year":"2004","journal-title":"Intensive Care Med"},{"issue":"5","key":"10.1053\/j.ackd.2016.01.015_bib35","doi-asserted-by":"crossref","first-page":"R188","DOI":"10.1186\/cc11672","article-title":"Respiratory variations of inferior vena cava diameter to predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure: need for a cautious use","volume":"16","author":"Muller","year":"2012","journal-title":"Crit Care"},{"issue":"1","key":"10.1053\/j.ackd.2016.01.015_bib36","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1186\/s13054-015-1100-9","article-title":"Does inferior vena cava respiratory variability predict fluid responsiveness in spontaneously breathing patients?","volume":"19","author":"Airapetian","year":"2015","journal-title":"Crit Care"},{"issue":"1","key":"10.1053\/j.ackd.2016.01.015_bib37","doi-asserted-by":"crossref","first-page":"3","DOI":"10.7863\/ultra.33.1.3","article-title":"Volume responsiveness in critically ill patients: use of sonography to guide management","volume":"33","author":"Evans","year":"2014","journal-title":"J\u00a0Ultrasound Med"},{"issue":"2","key":"10.1053\/j.ackd.2016.01.015_bib38","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1097\/ALN.0000000000000300","article-title":"Lung ultrasound predicts well extravascular lung water but is of limited usefulness in the prediction of wedge pressure","volume":"121","author":"Volpicelli","year":"2014","journal-title":"Anesthesiology"},{"key":"10.1053\/j.ackd.2016.01.015_bib39","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1186\/s13054-015-0756-5","article-title":"Simplified lung ultrasound protocol shows excellent prediction of extravascular lung water in ventilated intensive care patients","volume":"19","author":"Enghard","year":"2015","journal-title":"Crit Care"},{"issue":"6","key":"10.1053\/j.ackd.2016.01.015_bib40","doi-asserted-by":"crossref","first-page":"1433","DOI":"10.1378\/chest.08-1811","article-title":"Ultrasound assessment for extravascular lung water in patients undergoing hemodialysis","volume":"135","author":"Noble","year":"2009","journal-title":"Chest"},{"key":"10.1053\/j.ackd.2016.01.015_bib41","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1681\/ASN.2012100990","article-title":"Pulmonary congestion predicts\u00a0cardiac events and mortality in ESRD","volume":"24","author":"Zoccali","year":"2013","journal-title":"J Am Soc Nephrol"},{"issue":"1","key":"10.1053\/j.ackd.2016.01.015_bib42","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1007\/s11255-013-0500-5","article-title":"Lung ultrasound during hemodialysis: the role in the assessment of volume status","volume":"46","author":"Vitturi","year":"2013","journal-title":"Int Urol Nephrol"},{"issue":"5","key":"10.1053\/j.ackd.2016.01.015_bib43","doi-asserted-by":"crossref","first-page":"533.e11","DOI":"10.1016\/j.jcrc.2012.03.004","article-title":"Integrating lung ultrasound in the hemodynamic evaluation of acute circulatory failure (the fluid administration limited by lung sonography protocol)","volume":"27","author":"Lichtenstein","year":"2012","journal-title":"J Crit Care"}],"container-title":["Advances in Chronic Kidney Disease"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1548559516000161?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1548559516000161?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,9,12]],"date-time":"2018-09-12T23:24:20Z","timestamp":1536794660000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1548559516000161"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,5]]},"references-count":43,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2016,5]]}},"alternative-id":["S1548559516000161"],"URL":"https:\/\/doi.org\/10.1053\/j.ackd.2016.01.015","relation":{},"ISSN":["1548-5595"],"issn-type":[{"value":"1548-5595","type":"print"}],"subject":[],"published":{"date-parts":[[2016,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Critical Care Ultrasound: A Review for Practicing Nephrologists","name":"articletitle","label":"Article Title"},{"value":"Advances in Chronic Kidney Disease","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1053\/j.ackd.2016.01.015","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2016 The National Kidney Foundation, Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}